1.
Med Tekh ; (6): 3-10, 2001.
Artículo en Ruso | MEDLINE | ID: mdl-11837192

RESUMEN

Treatment of extensive tissue defects should be complex, whose basis is an early free skin plastic repair with obligatory addition of agents that enhance the reparative capacities of tissues. For this, the authors propose a number of original appliances (forceps, variants of dermoperforators, bandage, etc.) and drugs, such as ximedon (tablets, 5-10% aqueous solution, lanolin-vaseline-based ointment, talc-based powder), whose clinical trials in 300 patients have shown their high therapeutical effect. The time of preparation of the wound surface for dermatoplastic interventions became shorter and the frequency of poor outcomes of operations reduced.


Asunto(s)
Adyuvantes Inmunológicos/uso terapéutico , Pirimidinas/uso terapéutico , Trasplante de Piel/instrumentación , Trasplante de Piel/métodos , Adyuvantes Inmunológicos/administración & dosificación , Humanos , Pomadas , Pirimidinas/administración & dosificación , Regeneración , Fenómenos Fisiológicos de la Piel , Traumatismos de los Tejidos Blandos/cirugía , Colgajos Quirúrgicos , Instrumentos Quirúrgicos
3.
Khirurgiia (Mosk) ; (6): 75-8, 1989 Jun.
Artículo en Ruso | MEDLINE | ID: mdl-2779131

RESUMEN

Experiments on 200 animals and clinical use of 300 scalpels differing in the width of the cutting edge showed that operative lineal skin incisions made with a sharp instrument (a ruby knife, razor, scalpel with a 0.8 microns cutting edge) heal better and quicker than those inflicted with a blunt scalpel of serial production with a cutting edge 12.5 microns wide. Such blunting of scapels occurs after two operations and traditional methods of sterilization of the instruments. Mechanical damage of the instruments during cleansing and washing is most important in the clinic.


Asunto(s)
Aleaciones , Procedimientos Quirúrgicos Dermatologicos , Acero , Instrumentos Quirúrgicos/normas , Cicatrización de Heridas , Heridas Penetrantes/fisiopatología , Animales , Humanos , Conejos , Ratas , Piel/fisiopatología , Heridas Penetrantes/etiología
4.
Med Tekh ; (2): 10-3, 1988.
Artículo en Ruso | MEDLINE | ID: mdl-3405054

RESUMEN

Tiny rotation-plate pneumomotors be made with a rotor lengthened to 3-5 diametres of a rotor with simultaneous gaz supply through 2-3 channels. It is recommended to use the kinetic energy of air current and a piston system of pneumomotor start.


Asunto(s)
Diseño de Equipo , Equipo Ortopédico/normas , Osteotomía/instrumentación , Aire , Humanos , Presión , Rotación , Suiza , U.R.S.S.
5.
Med Tekh ; (2): 3-10, 1988.
Artículo en Ruso | MEDLINE | ID: mdl-3405061

RESUMEN

New original constructions of pneumatic motors and nozzles (with guaranteed start up of a pneumomotor with a nozzle) are described. They ensure non-traumatic treatment of osseous tissues and exclude the breakage of a cutting instrument in work.


Asunto(s)
Enfermedades Óseas/cirugía , Fracturas Óseas/cirugía , Equipo Ortopédico , Osteotomía/instrumentación , Aire , Diseño de Equipo , Europa (Continente) , Humanos , Presión , U.R.S.S. , Estados Unidos
6.
Med Tekh ; (1): 36-40, 1988.
Artículo en Ruso | MEDLINE | ID: mdl-3362053

RESUMEN

Introduction of newer dental instruments is foreseen owing to the perfection of manufacturing methods, equipment and rigging.


Asunto(s)
Equipo Dental , Instrumentos Dentales , Humanos , U.R.S.S.
7.
Med Tekh ; (1): 7-11, 1988.
Artículo en Ruso | MEDLINE | ID: mdl-3362058

RESUMEN

Piston compressor without lubrication with air blow to packing rings by plunger, disposed in subpiston space, is recommended as the basic scheme of construction of a power supply unit for medical pneumatic tooling. The construction reduces a leak of the compressive medium, increasing the efficiency of a compressor and seal reliability.


Asunto(s)
Suministros de Energía Eléctrica , Ciencia del Laboratorio Clínico/instrumentación , Lubrificación
8.
Med Tekh ; (1): 43-8, 1987.
Artículo en Ruso | MEDLINE | ID: mdl-3550360

RESUMEN

The main tendency in designing mechanized medical instruments is developing systems with automatic fine adjustment and self-regulation. The automated gear adjustment, self-regulating mouthpieces and cutting tools create a flexible automated system with optimal cutting regime. The instruments do not overheat bone tissues which helps to avoid unnecessary traumatization.


Asunto(s)
Huesos/cirugía , Equipo Quirúrgico , Instrumentos Quirúrgicos , Suministros de Energía Eléctrica , Diseño de Equipo , Humanos , Movimiento (Física) , Transductores
10.
Med Tekh ; (2): 50-1, 1984.
Artículo en Ruso | MEDLINE | ID: mdl-6374362

RESUMEN

A set for experimental studies of heat release in the process of bone cutting by drills , circular saws, cutters and so on is produced and tested. With the set, a rotational speed of instruments may be varied over a range of I to 200 s-1 and up to 8330 s-1 when using dental tips.


Asunto(s)
Equipo Dental de Alta Velocidad , Osteotomía/instrumentación , Trepanación/instrumentación , Humanos , Rotación
11.
Med Tekh ; (1): 41-5, 1984.
Artículo en Ruso | MEDLINE | ID: mdl-6708765

RESUMEN

An experimental set is developed to study and test pneumatic micromotors. With the set, the following parameters may be measured: a rotatory speed, a torque, air discharge and pressure, temperature of the micromotor housing. The set may be also used as a load in tests for reability.


Asunto(s)
Electrónica Médica/instrumentación , Equipos y Suministros , Diseño de Equipo , Estudios de Evaluación como Asunto
12.
Med Tekh ; (1): 26-31, 1984.
Artículo en Ruso | MEDLINE | ID: mdl-6369063

RESUMEN

The method to compute friction loss in medical microturbines and tips at the stage of their development is proposed. It is verified when designing friction loss of the following devices: a turbine tip HTC-300-02, a pneumatic micromotor MMP-20, and micromotor tips (NVP-30M) and (NP-30M). The method may be useful in estimated designs of friction loss.


Asunto(s)
Equipo Dental de Alta Velocidad , Diseño de Equipo , Falla de Equipo , Matemática , Estrés Mecánico
13.
Med Tekh ; (6): 16-9, 1983.
Artículo en Ruso | MEDLINE | ID: mdl-6664262

RESUMEN

Rotary-plate motors with the increased power are recommended for using in medical pneumatically-driven instruments. Provided in the design bumper pockets make it possible to raise the power of the pneumatic motor while its dimensions and weight remain unchanged.


Asunto(s)
Equipos y Suministros , Diseño de Equipo , Ciencia del Laboratorio Clínico
14.
Med Tekh ; (3): 5-9, 1983.
Artículo en Ruso | MEDLINE | ID: mdl-6888225

RESUMEN

The methodology of designing performance for medical microturbines is described. The method has been verified when designing the net moment and power of a turbine tip HTC-300-02 and a micromotor MMp-20. The comparison of theoretical and experimental data has shown the discordance to be less than 5%.


Asunto(s)
Equipos y Suministros , Diseño de Equipo , Matemática , Rotación
15.
Med Tekh ; (2): 14-9, 1983.
Artículo en Ruso | MEDLINE | ID: mdl-6343753

RESUMEN

In order to extend an operating range of angular tips, six types of these tips for micromotors and a coupling are designed. In the course of experimental studies using a suitable set the temperature of heads as well as friction loss in the tips and the coupling have been measured. The specified relationships made it possible to define more exactly the operating range for the tips according to their rotational speed.


Asunto(s)
Equipo Dental de Alta Velocidad , Tecnología Odontológica
16.
Med Tekh ; (3): 21-4, 1982.
Artículo en Ruso | MEDLINE | ID: mdl-7050601

RESUMEN

Experimental studies of handpieces for micromotors have been performed to make more precise their operating parameters. The special stand has been used for the measurements of the following data: head temperature, power losses in handpieces at no-load, and operating power required for machining by means of spherical burrs. The experimental results made it possible to specify more exactly the range of handpiece rotational speeds and to select optimum loads under reliability testing.


Asunto(s)
Equipo Dental de Alta Velocidad , Estudios de Evaluación como Asunto
SELECCIÓN DE REFERENCIAS