Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Anaesthesiologie ; 73(8): 502-510, 2024 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-39060458

RESUMEN

Small, portable hand-held ultrasound devices nowadays enable a widespread use of prehospital point-of-care ultrasound (pPOCUS), which has so far only been used hesitantly, especially in ground-based emergency services. Many critical or even life-threatening conditions or internal injuries can often be better diagnosed or ruled out using pPOCUS, which can enable faster and more suitable goal-directed treatment and hospital transport. This article critically discusses relevant data, clinical benefits, limitations and challenges to be overcome when using pPOCUS for the most important life-threatening situations and aims to call for intensifying training and the extensive use of pPOCUS.


Asunto(s)
Servicios Médicos de Urgencia , Medicina de Emergencia , Sistemas de Atención de Punto , Ultrasonografía , Humanos , Servicios Médicos de Urgencia/métodos , Ultrasonografía/métodos , Ultrasonografía/instrumentación , Medicina de Emergencia/educación , Medicina de Emergencia/métodos
2.
Int J Comput Assist Radiol Surg ; 17(9): 1707-1716, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35357633

RESUMEN

PURPOSE: For the visualization of pulmonary ventilation with Electrical Impedance Tomography (EIT) most devices use standard reconstruction models, featuring common thorax dimensions and predetermined electrode locations. Any discrepancies between the available model and the patient in terms of body shape and electrode position lead to incorrectly displayed impedance distributions. This work addresses that problem by presenting and evaluating a method for 3D model generation of the thorax and any affixed electrodes based on handheld video-footage. METHODS: Therefore, a process was developed, providing users with the ability to capture a patient's chest and the attached electrodes via smartphone. Once data is collected, extracted images are used to generate a 3D model with a structure from motion approach and locate electrodes with ArUco markers. For the evaluation of the developed method, multiple tests were performed in laboratory environments, which were compared with manually created reference models and differences quantified based on mean distance, standard deviation, and maximum distance. RESULTS: The implemented workflow allows for automated model reconstruction based on videos or selected images captured with a handheld device. It generates sparse point clouds from which a surface mesh is reconstructed and returns relative coordinates of any identified ArUco marker. The average value for the mean distance error of two model generations was 5.4 mm while the mean standard deviation was 6.0 mm. The average runtime of twelve reconstructions was 5:17 min, with a minimal runtime of 3:22 min and a maximal runtime of 7:29 min. CONCLUSION: The presented methods and results show that model reconstruction of a patient's thorax and applied electrodes at an emergency site is feasible with already available devices. This is a first step toward the automated generation of patient-specific reconstruction models for Electrical Impedance Tomography based on images recorded with handheld devices.


Asunto(s)
Tórax , Tomografía , Impedancia Eléctrica , Electrodos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía/métodos , Tomografía Computarizada por Rayos X
3.
Anesthesiology ; 134(6): 887-900, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33843980

RESUMEN

BACKGROUND: General anesthesia may cause atelectasis and deterioration in oxygenation in obese patients. The authors hypothesized that individualized positive end-expiratory pressure (PEEP) improves intraoperative oxygenation and ventilation distribution compared to fixed PEEP. METHODS: This secondary analysis included all obese patients recruited at University Hospital of Leipzig from the multicenter Protective Intraoperative Ventilation with Higher versus Lower Levels of Positive End-Expiratory Pressure in Obese Patients (PROBESE) trial (n = 42) and likewise all obese patients from a local single-center trial (n = 54). Inclusion criteria for both trials were elective laparoscopic abdominal surgery, body mass index greater than or equal to 35 kg/m2, and Assess Respiratory Risk in Surgical Patients in Catalonia (ARISCAT) score greater than or equal to 26. Patients were randomized to PEEP of 4 cm H2O (n = 19) or a recruitment maneuver followed by PEEP of 12 cm H2O (n = 21) in the PROBESE study. In the single-center study, they were randomized to PEEP of 5 cm H2O (n = 25) or a recruitment maneuver followed by individualized PEEP (n = 25) determined by electrical impedance tomography. Primary endpoint was Pao2/inspiratory oxygen fraction before extubation and secondary endpoints included intraoperative tidal volume distribution to dependent lung and driving pressure. RESULTS: Ninety patients were evaluated in three groups after combining the two lower PEEP groups. Median individualized PEEP was 18 (interquartile range, 16 to 22; range, 10 to 26) cm H2O. Pao2/inspiratory oxygen fraction before extubation was 515 (individual PEEP), 370 (fixed PEEP of 12 cm H2O), and 305 (fixed PEEP of 4 to 5 cm H2O) mmHg (difference to individualized PEEP, 145; 95% CI, 91 to 200; P < 0.001 for fixed PEEP of 12 cm H2O and 210; 95% CI, 164 to 257; P < 0.001 for fixed PEEP of 4 to 5 cm H2O). Intraoperative tidal volume in the dependent lung areas was 43.9% (individualized PEEP), 25.9% (fixed PEEP of 12 cm H2O) and 26.8% (fixed PEEP of 4 to 5 cm H2O) (difference to individualized PEEP: 18.0%; 95% CI, 8.0 to 20.7; P < 0.001 for fixed PEEP of 12 cm H2O and 17.1%; 95% CI, 10.0 to 20.6; P < 0.001 for fixed PEEP of 4 to 5 cm H2O). Mean intraoperative driving pressure was 9.8 cm H2O (individualized PEEP), 14.4 cm H2O (fixed PEEP of 12 cm H2O), and 18.8 cm H2O (fixed PEEP of 4 to 5 cm H2O), P < 0.001. CONCLUSIONS: This secondary analysis of obese patients undergoing laparoscopic surgery found better oxygenation, lower driving pressures, and redistribution of ventilation toward dependent lung areas measured by electrical impedance tomography using individualized PEEP. The impact on patient outcome remains unclear.


Asunto(s)
Atelectasia Pulmonar , Respiración Artificial , Humanos , Obesidad , Respiración con Presión Positiva , Volumen de Ventilación Pulmonar
4.
Eur J Anaesthesiol ; 37(12): 1105-1114, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33105246

RESUMEN

BACKGROUND: Ultrasound-guided interscalene brachial plexus block (ISB) is used to control pain after shoulder surgery. Though effective, drawbacks include phrenic nerve block and motor block of the hand. The ultrasound-guided anterior approach to perform suprascapular nerve block (SSNB) may provide a good alternative. OBJECTIVE: To compare lung ventilation and diaphragmatic activity on the operated side in ISB and SSNB. DESIGN: Randomised, controlled patient-blinded and assessor-blinded trial. SETTING: Outpatient surgical clinic with recruitment from June 2017 to January 2018. PATIENTS: Fifty-five outpatients scheduled for arthroscopic shoulder surgery were allocated randomly to receive SSNB or ISB. Technical problems with monitoring devices unrelated to the intervention led to exclusion of seven patients. The remaining 48 (n=24 in each group) were followed up for 24 h without drop-outs. INTERVENTIONS: Patients received 10 ml of ropivacaine 1.0% wt/vol for both procedures. OUTCOME MEASURES: Percentage lung ventilation on the operated side was the primary endpoint as assessed with electrical impedance tomography (EIT). Secondary endpoints were hemidiaphragmatic motion on the operated side, pain, opioid use, hand strength and numbness, and patient satisfaction. RESULTS: Before regional anaesthesia, the lung on the operated side contributed a median [IQR] of 50 [42 to 56]% of the total lung ventilation. Postoperatively, it was 40 [3 to 50]% (SSNB) vs. 3 [1 to 13]% (ISB) for an adjusted difference of 23 (95% CI, 13 to 34)%, (P < 0.001). Hemidiaphragmatic motion was 1.90 (95% CI, 1.37 to 2.44 cm), (P < 0.001) lower in the ISB group compared with the SSNB group. Hand strength was 11.2 (95% CI 3.6 to 18.9), (P = 0.0024) kg greater for SSNB and numbness was observed in 0% (SSNB) vs. 46% (ISB) of patients, P < 0.001. Pain was low in the first 6 h after surgery in both groups with slightly, but not significantly, lower values for ISB. No meaningful or significant differences were found for opioid use or patient satisfaction. CONCLUSION: An ultrasound-guided anterior approach to SSNB preserves ipsilateral lung ventilation and phrenic function better than a standard ISB. TRIAL REGISTRATION: drks.de identifier: DRKS00011787.


Asunto(s)
Bloqueo del Plexo Braquial , Anestésicos Locales , Artroscopía , Impedancia Eléctrica , Humanos , Pulmón , Dolor Postoperatorio , Hombro , Tomografía , Ultrasonografía Intervencional
5.
Br J Anaesth ; 125(3): 373-382, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32665059

RESUMEN

BACKGROUND: Robot-assisted laparoscopic radical prostatectomy requires general anaesthesia, extreme Trendelenburg positioning and capnoperitoneum. Together these promote impaired pulmonary gas exchange caused by atelectasis and may contribute to postoperative pulmonary complications. In morbidly obese patients, a recruitment manoeuvre (RM) followed by individualised PEEP improves intraoperative oxygenation and end-expiratory lung volume (EELV). We hypothesised that individualised PEEP with initial RM similarly improves intraoperative oxygenation and EELV in non-obese individuals undergoing robot-assisted prostatectomy. METHODS: Forty males (age, 49-76 yr; BMI <30 kg m-2) undergoing prostatectomy received volume-controlled ventilation (tidal volume 8 ml kg-1 predicted body weight). Participants were randomised to either (1) RM followed by individualised PEEP (RM/PEEPIND) optimised using electrical impedance tomography or (2) no RM with 5 cm H2O PEEP. The primary outcome was the ratio of arterial oxygen partial pressure to fractional inspired oxygen (Pao2/Fio2) before the last RM before extubation. Secondary outcomes included regional ventilation distribution and EELV which were measured before, during, and after anaesthesia. The cardiovascular effects of RM/PEEPIND were also assessed. RESULTS: In 20 males randomised to RM/PEEPIND, the median PEEPIND was 14 cm H2O [inter-quartile range, 8-20]. The Pao2/Fio2 was 10.0 kPa higher with RM/PEEPIND before extubation (95% confidence interval [CI], 2.6-17.3 kPa; P=0.001). RM/PEEPIND increased end-expiratory lung volume by 1.49 L (95% CI, 1.09-1.89 L; P<0.001). RM/PEEPIND also improved the regional ventilation of dependent lung regions. Vasopressor and fluid therapy was similar between groups, although 13 patients randomised to RM/PEEPIND required pharmacological therapy for bradycardia. CONCLUSION: In non-obese males, an individualised ventilation strategy improved intraoperative oxygenation, which was associated with higher end-expiratory lung volumes during robot-assisted laparoscopic prostatectomy. CLINICAL TRIAL REGISTRATION: DRKS00004199 (German clinical trials registry).


Asunto(s)
Impedancia Eléctrica , Respiración con Presión Positiva/métodos , Prostatectomía/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Anciano , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
6.
PLoS One ; 15(1): e0227518, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31923268

RESUMEN

INTRODUCTION: Posttraumatic pneumothorax (PTX) is often overseen in anteroposterior chest X-ray. Chest sonography and Electrical Impedance Tomography (EIT) can both be used at the bedside and may provide complementary information. We evaluated the performance of EIT for diagnosing posttraumatic PTX in a pig model. METHODS: This study used images from an existing database of images acquired from 17 mechanically ventilated pigs, which had sustained standardized blunt chest trauma and had undergone repeated thoracic CT and EIT. 100 corresponding EIT/CT datasets were randomly chosen from the database and anonymized. Two independent and blinded observers analyzed the EIT data for presence and location of PTX. Analysis of the corresponding CTs by a radiologist served as reference. RESULTS: 87/100 cases had at least one PTX detected by CT. Fourty-two cases showed a PTX > 20% of the sternovertebral diameter (PTXtrans20), whereas 52/100 PTX showed a PTX>3 cm in the craniocaudal diameter (PTXcc3), with 20 cases showing both a PTXtranscc and a PTXcc3. We found a very low agreement between both EIT observers considering the classification overall PTX/noPTX (κ = 0.09, p = 0.183). For PTXtrans20, sensitivity was 59% for observer 1 and 17% for observer 2, with a specificity of 48% and 50%, respectively. For PTXcc3, observer 1 showed a sensitivity of 60% with a specificity of 51% while the sensitivity of observer 2 was 17%, with a specificity of 89%. By programming a semi-automatized detection algorithm, we significantly improved the detection rate of PTXcc3, with a sensitivity of 73% and a specificity of 70%. However, detection of PTXtranscc was not improved. CONCLUSION: In our analysis, visual interpretation of EIT without specific image processing or comparison with baseline data did not allow clinically useful diagnosis of posttraumatic PTX. Multimodal imaging approaches, technical improvements and image postprocessing algorithms might improve the performance of EIT for diagnosing PTX in the future.


Asunto(s)
Impedancia Eléctrica , Neumotórax/diagnóstico , Traumatismos Torácicos/patología , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Animales , Neumotórax/etiología , Neumotórax/veterinaria , Respiración Artificial , Porcinos , Traumatismos Torácicos/complicaciones , Traumatismos Torácicos/veterinaria , Ultrasonografía , Heridas no Penetrantes/complicaciones , Heridas no Penetrantes/patología , Heridas no Penetrantes/veterinaria
7.
J Clin Med ; 8(8)2019 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-31426607

RESUMEN

Reducing ventilator-associated lung injury by individualized mechanical ventilation (MV) in patients with Acute Respiratory Distress Syndrome (ARDS) remains a matter of research. We randomly assigned 27 pigs with acid aspiration-induced ARDS to three different MV protocols for 24 h, targeting different magnitudes of collapse and tidal recruitment (collapse&TR): the ARDS-network (ARDSnet) group with low positive end-expiratory pressure (PEEP) protocol (permissive collapse&TR); the Open Lung Concept (OLC) group, PaO2/FiO2 >400 mmHg, indicating collapse&TR <10%; and the minimized collapse&TR monitored by Electrical Impedance Tomography (EIT) group, standard deviation of regional ventilation delay, SDRVD. We analyzed cardiorespiratory parameters, computed tomography (CT), EIT, and post-mortem histology. Mean PEEP over post-randomization measurements was significantly lower in the ARDSnet group at 6.8 ± 1.0 cmH2O compared to the EIT (21.1 ± 2.6 cmH2O) and OLC (18.7 ± 3.2 cmH2O) groups (general linear model (GLM) p < 0.001). Collapse&TR and SDRVD, averaged over all post-randomization measurements, were significantly lower in the EIT and OLC groups than in the ARDSnet group (collapse p < 0.001, TR p = 0.006, SDRVD p < 0.004). Global histological diffuse alveolar damage (DAD) scores in the ARDSnet group (10.1 ± 4.3) exceeded those in the EIT (8.4 ± 3.7) and OLC groups (6.3 ± 3.3) (p = 0.16). Sub-scores for edema and inflammation differed significantly (ANOVA p < 0.05). In a clinically realistic model of early ARDS with recruitable and nonrecruitable collapse, mechanical ventilation involving recruitment and high-PEEP reduced collapse&TR and resulted in improved hemodynamic and physiological conditions with a tendency to reduced histologic lung damage.

8.
Reg Anesth Pain Med ; 43(1): 98-99, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29261597
9.
Reg Anesth Pain Med ; 43(1): 100, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29261599
10.
Reg Anesth Pain Med ; 42(3): 310-318, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28257388

RESUMEN

BACKGROUND AND OBJECTIVES: The interscalene brachial plexus block (ISB), a potent option to control pain after shoulder surgery, has notable adverse effects. The anterior suprascapular nerve block (SSNB) might provide comparable analgesia and cause less grip-strength impairment. These characteristics were studied in this randomized controlled patient- and assessor-blinded trial. METHODS: Outpatients were randomized to single-shot ultrasound-guided SSNB (10 mL ropivacaine 1%) or ISB (20 mL ropivacaine 0.75%) before general anesthesia for arthroscopic shoulder surgery. Pain (Numerical Rating Scale, 0-10), grip strength, degree of satisfaction, and strength of recommendation were assessed. RESULTS: We randomized 168 patients to each group and analyzed 164 in the SSNB group and 165 in the ISB group. Nerve blocks were successful in 98% of the patients from each group. Both procedures provided good postoperative analgesia, and the mean pain level for SSNB was slightly but significantly lower by 0.32 units (95% confidence interval, 0.18-0.46; P < 0.001) and noninferior given a margin of 1.1 units; P < 0.001. Within the first 24 hours, 162 (99%) of SSNB patients had unimpaired grip strength compared to 81 (49%) of ISB patients (P < 0.001). The multiple primary outcome, superior unimpaired grip strength, and noninferior pain control was significant; P < 0.001. Compared to ISB patients (n = 130 [79%]), significantly more SSNB patients (n = 150 [91%]) were satisfied/highly satisfied. Patients in the SSNB group were more likely to recommend the procedure highly. CONCLUSIONS: For outpatients undergoing arthroscopic shoulder surgery under general anesthesia, the SSNB seems preferable to ISB. It provides excellent postoperative analgesia without exposing patients to impaired mobility and to risks of the more potent but also more invasive ISB.


Asunto(s)
Procedimientos Quirúrgicos Ambulatorios/métodos , Artroscopía/métodos , Bloqueo Nervioso Autónomo/métodos , Bloqueo del Plexo Braquial/métodos , Hombro/cirugía , Adulto , Anciano , Procedimientos Quirúrgicos Ambulatorios/normas , Bloqueo Nervioso Autónomo/normas , Bloqueo del Plexo Braquial/normas , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dolor Postoperatorio/diagnóstico por imagen , Dolor Postoperatorio/prevención & control , Escápula/diagnóstico por imagen , Escápula/cirugía , Hombro/diagnóstico por imagen
11.
Crit Care Med ; 45(4): 679-686, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28079607

RESUMEN

OBJECTIVES: Lung-protective mechanical ventilation aims to prevent alveolar collapse and overdistension, but reliable bedside methods to quantify them are lacking. We propose a quantitative descriptor of the shape of local pressure-volume curves derived from electrical impedance tomography, for computing maps that highlight the presence and location of regions of presumed tidal recruitment (i.e., elastance decrease during inflation, pressure-volume curve with upward curvature) or overdistension (i.e., elastance increase during inflation, downward curvature). DESIGN: Secondary analysis of experimental cohort study. SETTING: University research facility. SUBJECTS: Twelve mechanically ventilated pigs. INTERVENTIONS: After induction of acute respiratory distress syndrome by hydrochloric acid instillation, animals underwent a decremental positive end-expiratory pressure titration (steps of 2 cm H2O starting from ≥ 26 cm H2O). MEASUREMENTS AND MAIN RESULTS: Electrical impedance tomography-derived maps were computed at each positive end-expiratory pressure-titration step, and whole-lung CT taken every second steps. Airway flow and pressure were recorded to compute driving pressure and elastance. Significant correlations between electrical impedance tomography-derived maps and positive end-expiratory pressure indicate that, expectedly, tidal recruitment increases in dependent regions with decreasing positive end-expiratory pressure (p < 0.001) and suggest that overdistension increases both at high and low positive end-expiratory pressures in nondependent regions (p < 0.027), supporting the idea of two different scenarios of overdistension occurrence. Significant correlations with CT measurements were observed: electrical impedance tomography-derived tidal recruitment with poorly aerated regions (r = 0.43; p < 0.001); electrical impedance tomography-derived overdistension with nonaerated regions at lower positive end-expiratory pressures and with hyperaerated regions at higher positive end-expiratory pressures (r ≥ 0.72; p < 0.003). Even for positive end-expiratory pressure levels minimizing global elastance and driving pressure, electrical impedance tomography-derived maps showed nonnegligible regions of presumed overdistension and tidal recruitment. CONCLUSIONS: Electrical impedance tomography-derived maps of pressure-volume curve shapes allow to detect regions in which elastance changes during inflation. This could promote individualized mechanical ventilation by minimizing the probability of local tidal recruitment and/or overdistension. Electrical impedance tomography-derived maps might become clinically feasible and relevant, being simpler than currently available alternative approaches.


Asunto(s)
Impedancia Eléctrica , Pulmón/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Tomografía , Animales , Modelos Animales de Enfermedad , Elasticidad , Pulmón/fisiopatología , Respiración con Presión Positiva , Presión , Síndrome de Dificultad Respiratoria/fisiopatología , Síndrome de Dificultad Respiratoria/terapia , Porcinos
13.
BMC Anesthesiol ; 16: 3, 2016 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-26757894

RESUMEN

BACKGROUND: Uncertainty persists regarding the optimal ventilatory strategy in trauma patients developing acute respiratory distress syndrome (ARDS). This work aims to assess the effects of two mechanical ventilation strategies with high positive end-expiratory pressure (PEEP) in experimental ARDS following blunt chest trauma. METHODS: Twenty-six juvenile pigs were anesthetized, tracheotomized and mechanically ventilated. A contusion was applied to the right chest using a bolt-shot device. Ninety minutes after contusion, animals were randomized to two different ventilation modes, applied for 24 h: Twelve pigs received conventional pressure-controlled ventilation with moderately low tidal volumes (VT, 8 ml/kg) and empirically chosen high external PEEP (16 cmH2O) and are referred to as the HP-CMV-group. The other group (n = 14) underwent high-frequency inverse-ratio pressure-controlled ventilation (HFPPV) involving respiratory rate of 65 breaths · min(-1), inspiratory-to-expiratory-ratio 2:1, development of intrinsic PEEP and recruitment maneuvers, compatible with the rationale of the Open Lung Concept. Hemodynamics, gas exchange and respiratory mechanics were monitored during 24 h. Computed tomography and histology were analyzed in subgroups. RESULTS: Comparing changes which occurred from randomization (90 min after chest trauma) over the 24-h treatment period, groups differed statistically significantly (all P values for group effect <0.001, General Linear Model analysis) for the following parameters (values are mean ± SD for randomization vs. 24-h): PaO2 (100% O2) (HFPPV 186 ± 82 vs. 450 ± 59 mmHg; HP-CMV 249 ± 73 vs. 243 ± 81 mmHg), venous admixture (HFPPV 34 ± 9.8 vs. 11.2 ± 3.7%; HP-CMV 33.9 ± 10.5 vs. 21.8 ± 7.2%), PaCO2 (HFPPV 46.9 ± 6.8 vs. 33.1 ± 2.4 mmHg; HP-CMV 46.3 ± 11.9 vs. 59.7 ± 18.3 mmHg) and normally aerated lung mass (HFPPV 42.8 ± 11.8 vs. 74.6 ± 10.0 %; HP-CMV 40.7 ± 8.6 vs. 53.4 ± 11.6%). Improvements occurring after recruitment in the HFPPV-group persisted throughout the study. Peak airway pressure and VT did not differ significantly. HFPPV animals had lower atelectasis and inflammation scores in gravity-dependent lung areas. CONCLUSIONS: In this model of ARDS following unilateral blunt chest trauma, HFPPV ventilation improved respiratory function and fulfilled relevant ventilation endpoints for trauma patients, i.e. restoration of oxygenation and lung aeration while avoiding hypercapnia and respiratory acidosis.


Asunto(s)
Respiración Artificial/métodos , Síndrome de Dificultad Respiratoria/terapia , Mecánica Respiratoria/fisiología , Traumatismos Torácicos/terapia , Heridas no Penetrantes/terapia , Animales , Respiración con Presión Positiva/métodos , Distribución Aleatoria , Síndrome de Dificultad Respiratoria/etiología , Síndrome de Dificultad Respiratoria/fisiopatología , Porcinos , Traumatismos Torácicos/complicaciones , Traumatismos Torácicos/fisiopatología , Heridas no Penetrantes/complicaciones , Heridas no Penetrantes/fisiopatología
14.
A A Case Rep ; 6(7): 193-5, 2016 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-26752177

RESUMEN

An 82-year-old man required aortic valve replacement because of aortic stenosis. A transapical approach was chosen to reduce surgical mortality. Initially, echocardiography and fluoroscopy confirmed correct valve positioning. Shortly thereafter, progressive paravalvular leakage, embolization of the valve prosthesis into the ventricle, and subsequent inversion of the prosthesis with complete left ventricular outflow occlusion were observed by echocardiography. Left ventricular outflow occlusion resulted in immediate circulatory arrest. We immediately converted to on-pump surgical aortic valve replacement. Cardiac output was restored once the valve was replaced. The patient fully recovered. This case report highlights the importance of periprocedural transesophageal echocardiography, which instantly detected the malpositioned valve and guided emergency management of this severe complication.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/métodos , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/cirugía , Anciano de 80 o más Años , Ecocardiografía Transesofágica/métodos , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/etiología
15.
Artículo en Inglés | MEDLINE | ID: mdl-26504733

RESUMEN

Peripheral nerve catheters are effective and well-established tools to provide postoperative analgesia to patients undergoing orthopedic surgery. The performance of these techniques is usually considered safe. However, placement of nerve catheters may be associated with a considerable number of side effects and major complications have repeatedly been published. In this work, we report on a patient who underwent total knee replacement with spinal anesthesia and preoperative insertion of femoral and sciatic nerve catheters for postoperative analgesia. During insertion of the femoral catheter, significant resistance was encountered upon retracting the catheter. This occurred due to knotting of the catheter. The catheter had to be removed by operative intervention which has to be considered a major complication. The postoperative course was uneventful. The principles for removal of entrapped peripheral catheters are not well established, may differ from those for neuroaxial catheters, and range from cautious manipulation up to surgical intervention.

16.
PLoS One ; 10(8): e0135272, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26258686

RESUMEN

BACKGROUND: Atelectasis can provoke pulmonary and non-pulmonary complications after general anaesthesia. Unfortunately, there is no instrument to estimate atelectasis and prompt changes of mechanical ventilation during general anaesthesia. Although arterial partial pressure of oxygen (PaO2) and intrapulmonary shunt have both been suggested to correlate with atelectasis, studies yielded inconsistent results. Therefore, we investigated these correlations. METHODS: Shunt, PaO2 and atelectasis were measured in 11 sheep and 23 pigs with otherwise normal lungs. In pigs, contrasting measurements were available 12 hours after induction of acute respiratory distress syndrome (ARDS). Atelectasis was calculated by computed tomography relative to total lung mass (Mtotal). We logarithmically transformed PaO2 (lnPaO2) to linearize its relationships with shunt and atelectasis. Data are given as median (interquartile range). RESULTS: Mtotal was 768 (715-884) g in sheep and 543 (503-583) g in pigs. Atelectasis was 26 (16-47) % in sheep and 18 (13-23) % in pigs. PaO2 (FiO2 = 1.0) was 242 (106-414) mmHg in sheep and 480 (437-514) mmHg in pigs. Shunt was 39 (29-51) % in sheep and 15 (11-20) % in pigs. Atelectasis correlated closely with lnPaO2 (R2 = 0.78) and shunt (R2 = 0.79) in sheep (P-values<0.0001). The correlation of atelectasis with lnPaO2 (R2 = 0.63) and shunt (R2 = 0.34) was weaker in pigs, but R2 increased to 0.71 for lnPaO2 and 0.72 for shunt 12 hours after induction of ARDS. In both, sheep and pigs, changes in atelectasis correlated strongly with corresponding changes in lnPaO2 and shunt. DISCUSSION AND CONCLUSION: In lung-healthy sheep, atelectasis correlates closely with lnPaO2 and shunt, when blood gases are measured during ventilation with pure oxygen. In lung-healthy pigs, these correlations were significantly weaker, likely because pigs have stronger hypoxic pulmonary vasoconstriction (HPV) than sheep and humans. Nevertheless, correlations improved also in pigs after blunting of HPV during ARDS. In humans, the observed relationships may aid in assessing anaesthesia-related atelectasis.


Asunto(s)
Pulmón/fisiopatología , Atelectasia Pulmonar/fisiopatología , Intercambio Gaseoso Pulmonar , Síndrome de Dificultad Respiratoria/fisiopatología , Anestesia General , Animales , Humanos , Pulmón/diagnóstico por imagen , Pulmón/patología , Presión Parcial , Atelectasia Pulmonar/diagnóstico por imagen , Atelectasia Pulmonar/patología , Respiración Artificial , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/patología , Ovinos , Especificidad de la Especie , Porcinos , Tomografía Computarizada por Rayos X , Vasoconstricción
18.
Burns ; 40(1): 120-6, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23790395

RESUMEN

INTRODUCTION: The development of secondary abdominal compartment syndrome (ACS) is associated with multiple organ dysfunction. There is little information about the effects of decompressive laparotomy (DL) on respiratory function (RF) in burn patients developing ACS. PATIENTS AND METHODS: We retrospectively obtained data characterising RF from the database of an adult burn intensive care unit (BICU). Peak inspiratory pressure (Pip), PaO2/FiO2-ratio (P/F), static compliance (Cstat) and airway resistance (Raw) were analysed over the course of 60 h at 8 time points relative to DL. RESULTS: Thirty-five patients with ACS underwent DL with a mean percentage of total burned body surface area (TBSA) 39 ± 23% and mean intra-abdominal pressure 33 ± 7 mmHg. All patients presented with significantly deteriorating RF within 12h of DL (Pip 33 ± 4 to 39 ± 7 cm/H2O, p=0.003; P/F 232 ± 59 to 160 ± 55 mmHg, p<0.001, Cstat 34 ± 5 to 26 ± 6 mL/cmH2O, p<0.001; Raw 18 ± 3 to 24 ± 9 cm H2O/L/s, p=0.02). All these parameters improved significantly (p<0.001) after DL, regardless of the presence of inhalation injury or torso burns. Mortality was 71.4%. CONCLUSIONS: Variables characterising RF demonstrated a rapid deterioration before and a significant and sustained improvement after DL in burn patients developing ACS. Despite these respiratory improvements, DL was associated with low survival rates. Secondary ACS remains a challenge in burn patients and thus warrants particular attention during intensive care treatment.


Asunto(s)
Quemaduras/complicaciones , Descompresión Quirúrgica , Hipertensión Intraabdominal/cirugía , Pulmón/fisiopatología , Insuficiencia Respiratoria/fisiopatología , Adulto , Anciano , Resistencia de las Vías Respiratorias/fisiología , Superficie Corporal , Quemaduras por Inhalación/complicaciones , Estudios de Cohortes , Femenino , Humanos , Inhalación/fisiología , Hipertensión Intraabdominal/etiología , Hipertensión Intraabdominal/fisiopatología , Laparotomía , Masculino , Persona de Mediana Edad , Insuficiencia Multiorgánica/etiología , Insuficiencia Multiorgánica/fisiopatología , Pruebas de Función Respiratoria , Insuficiencia Respiratoria/etiología , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
20.
Crit Care Med ; 41(3): 732-43, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23318487

RESUMEN

OBJECTIVES: Studies correlating the arterial partial pressure of oxygen to the fraction of nonaerated lung assessed by CT shunt yielded inconsistent results. We systematically analyzed this relationship and scrutinized key methodological factors that may compromise it. We hypothesized that both physiological shunt and the ratio between PaO2 and the fraction of inspired oxygen enable estimation of CT shunt at the bedside. DESIGN: : Prospective observational clinical and laboratory animal investigations. SETTING: ICUs (University Hospital Leipzig, Germany) and Experimental Pulmonology Laboratory (University of São Paulo, Brazil). PATIENTS, SUBJECTS AND INTERVENTIONS: Whole-lung CT and arterial blood gases were acquired simultaneously in 77 patients mechanically ventilated with pure oxygen. A subgroup of 28 patients was submitted to different Fio2. We also studied 19 patients who underwent repeat CT. Furthermore we studied ten pigs with acute lung injury at multiple airway pressures, as well as a theoretical model relating PaO2 and physiological shunt. We logarithmically transformed the PaO2/Fio2 to change this nonlinear relationship into a linear regression problem. MEASUREMENTS AND MAIN RESULTS: We observed strong linear correlations between Riley's approximation of physiological shunt and CT shunt (R = 0.84) and between logarithmically transformed PaO2/Fio2 and CT shunt (R = 0.86), allowing us to construct a look-up table with prediction intervals. Strong linear correlations were also demonstrated within-patients (R = 0.95). Correlations were significantly improved by the following methodological issues: measurement of PaO2/Fio2 during pure oxygen ventilation, use of logarithmically transformed PaO2/Fio2 instead of the "raw" PaO2/Fio2, quantification of nonaerated lung as percentage of total lung mass and definition of nonaerated lung by the [-200 to +100] Hounsfield Units interval, which includes shunting units within less opacified lung regions. CONCLUSION: During pure oxygen ventilation, logarithmically transformed PaO2/Fio2 allows estimation of CT shunt and its changes in patients during systemic inflammation. Relevant intrapulmonary shunting seems to occur in lung regions with CT numbers between [-200 and +100] Hounsfield Units.


Asunto(s)
Análisis de los Gases de la Sangre/métodos , Pulmón/fisiopatología , Sistemas de Atención de Punto , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Animales , Brasil , Femenino , Alemania , Humanos , Unidades de Cuidados Intensivos , Pulmón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Modelos Animales , Estudios Prospectivos , Porcinos , Tomografía Computarizada por Rayos X , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA