Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 11(1): 6351, 2021 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-33737566

RESUMEN

Perillyl alcohol (POH) has been extensively studied for the treatment of peripheral and primary brain tumors. The intranasal route of administration has been preferred for dosing POH in early-stage clinical trials associated with promising outcomes in primary brain cancer. However, it is unclear how intranasal POH targets brain tumors in these patients. Multiple studies indicate that intranasally applied large molecules may enter the brain and cerebrospinal fluid (CSF) through direct olfactory and trigeminal nerve-associated pathways originating in the nasal mucosa that bypass the blood-brain barrier. It is unknown whether POH, a small molecule subject to extensive nasal metabolism and systemic absorption, may also undergo direct transport to brain or CSF from the nasal mucosa. Here, we compared CSF and plasma concentrations of POH and its metabolite, perillic acid (PA), following intranasal or intravascular POH application. Samples were collected over 70 min and assayed by high-performance liquid chromatography. Intranasal administration resulted in tenfold higher CSF-to-plasma ratios for POH and tenfold higher CSF levels for PA compared to equal dose intravascular administration. Our preclinical results demonstrate POH undergoes direct transport from the nasal mucosa to the CSF, a finding with potential significance for its efficacy as an intranasal chemotherapeutic for brain cancer.


Asunto(s)
Neoplasias Encefálicas/tratamiento farmacológico , Encéfalo/efectos de los fármacos , Monoterpenos/farmacología , Mucosa Nasal/efectos de los fármacos , Administración Intranasal , Animales , Barrera Hematoencefálica/efectos de los fármacos , Encéfalo/patología , Neoplasias Encefálicas/líquido cefalorraquídeo , Neoplasias Encefálicas/patología , Cromatografía Líquida de Alta Presión , Modelos Animales de Enfermedad , Humanos , Ratas , Nervio Trigémino/efectos de los fármacos
2.
Biomed Chromatogr ; 20(11): 1242-51, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16838265

RESUMEN

A rapid, sensitive and specific LC-MS-MS method has been developed for the determination of clarithromycin (CLA) in human plasma using roxithromycin (ROX) as the internal standard. Samples were prepared via liquid-liquid extraction with methyl tert-butyl ether (MTBE) and chromatographed on a Supelco RP(18) (4.6 x 50 mm, 3 microm particle size) column with a mobile phase consisting of acetonitrile:methanol:60 mM (pH 3.5) ammonium acetate buffer (32.5:32.5:35) at a constant flow rate of 0.8 mL/min. The run time was 3 min with retention times of approximately 1.65 and 1.70 min for CLA and ROX, respectively. Detection was performed on a PE Sciex API 365 mass spectrometer equipped with a turboionspray ionization source in multiple reaction monitoring (MRM) mode. The MRM pairs were m/z 748.5 --> m/z 158.2 for CLA and m/z 837.7 --> m/z 679.3 for ROX, respectively, with dwell times of 200 ms for each transition. The validated calibration curve range was 5.00-5000 ng/mL, based on 0.100 mL plasma sample volume with signal-to-noise ratio (S/N) greater than 60 for CLA at the lower limit of quantification level (5.00 ng/mL). The correlation coefficients (r(2)) of the calibration curves were better than or equal to 0.996. The inter-day (n = 18) precision and accuracy of the quality control (QC) samples were less than 3.58% RSD (relative standard deviation) and -10.8% bias, respectively. The intra-day (n = 6) precision and accuracy of the quality control samples were less than 5.0 and 12.6%, respectively. There was no significant deviation from the nominal values after a 10-fold dilution of high concentration QC samples using blank matrix. The QC samples were stable when left on the bench for 24 h or after three freeze-thaw cycles. The processed samples were also stable in HPLC autosampler at 10C for over 72 h. No matrix ionization suppression was observed when extracted blank matrix or reconstitution solvent was injected onto the system with post-column infusion of clarithromycin and roxithromycin. No carryover was observed when an extracted blank plasma sample was injected immediately after a 5000 ng/mL ULOQ (the upper limit of quantification) standard. The mean recovery was 81.5 and 78.3%, respectively, for clarithromycin and internal standard.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Claritromicina/sangre , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masas en Tándem/métodos , Estabilidad de Medicamentos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA