Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Mod Pathol ; 28(3): 391-402, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25216224

RESUMEN

Glucagon-like-peptide-1 (GLP1) analogs may induce thyroid or pancreatic diseases in animals, raising questions about their use in diabetic patients. There is, however, controversy regarding expression of GLP1 receptors (GLP1R) in human normal and diseased thyroid and pancreas. Here, 221 human thyroid and pancreas samples were analyzed for GLP1R immunohistochemistry and compared with quantitative in vitro GLP1R autoradiography. Neither normal nor hyperplastic human thyroids containing parafollicular C cells express GLP1R with either method. Papillary thyroid cancer do not, and medullary thyroid carcinomas rarely express GLP1R. Insulin- and somatostatin-producing cells in the normal pancreas express a high density of GLP1R, whereas acinar cells express them in low amounts. Ductal epithelial cells do not express GLP1R. All benign insulinomas express high densities of GLP1R, whereas malignant insulinomas rarely express them. All ductal pancreatic carcinomas are GLP1R negative, whereas 6/20 PanIN 1/2 and 0/12 PanIN 3 express GLP1R. Therefore, normal thyroid, including normal and hyperplastic C cells, or papillary thyroid cancer are not targets for GLP1 analogs in humans. Conversely, all pancreatic insulin- and somatostatin-producing cells are physiological GLP1 targets, as well as most acini. As normal ductal epithelial cells or PanIN 3 or ductal pancreatic carcinomas do not express GLP1R, it seems unlikely that GLP1R is related to neoplastic transformation in pancreas. GLP1R-positive medullary thyroid carcinomas and all benign insulinomas are candidates for in vivo GLP1R targeting.


Asunto(s)
Páncreas/metabolismo , Receptores de Glucagón/biosíntesis , Glándula Tiroides/metabolismo , Autorradiografía , Western Blotting , Receptor del Péptido 1 Similar al Glucagón , Humanos , Inmunohistoquímica , Neoplasias Pancreáticas/metabolismo , Enfermedades de la Tiroides/metabolismo , Neoplasias de la Tiroides/metabolismo
2.
Nucl Med Biol ; 41(6): 464-70, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24780298

RESUMEN

INTRODUCTION: The gastrin-releasing peptide receptor (GRPR) was shown to be expressed with high density on several types of cancers. Radiolabeled peptides for imaging and targeted radionuclide therapy have been developed. In this study, we evaluated the potential of statine-based bombesin antagonists, conjugated to 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) through oligoethyleneglycol spacers, labeled with (177)Lu and we determined the effect of polyethyleneglycol (PEG) spacer length on in vitro and in vivo properties. METHODS: The bombesin antagonists were synthesized on solid phase using Fmoc chemistry; the spacers Fmoc-dPEGx-OH (x=2, 4, 6 and 12) and the DOTA(tBu)3 were coupled using a standard procedure. The peptides were labeled with (177)Lu and evaluated in vitro (lipophilicity, serum stability, internalization and binding affinity assays). Biodistribution studies were performed in PC-3 tumor-bearing nude mice. RESULTS: The solid-phase synthesis was straightforward with an overall yield ranging from 30% to 35% based on the first Fmoc cleavage. The hydrophilicity increased with spacer length (logD: -1.95 vs -2.22 of PEG2 and PEG12 analogs, respectively). There is a tendency of increased serum stability by increasing the spacer length (T1/2=246±4 and 584±20 for PEG2 and PEG6 analogs, respectively) which seems to reverse with the PEG12 analog. The IC50 values are similar with the only significant difference of the PEG12 analog. The (177)Lu-labeled PEG4 and PEG6 conjugates showed similar pharmacokinetic with high tumor uptake and excellent tumor-to-kidney ratios (7.8 and 9.7 at 4h for the PEG4 and PEG6 derivatives, respectively). The pancreas uptake was relatively high at 1h but it shows fast washout (0.46%±0.02% IA/g and 0.29%±0.08% IA/g already at 4h). CONCLUSION: Among all the studied analogs the PEG4 and PEG6 showed significantly better properties. The very high tumor-to-non-target organ ratios, in particular tumor-to-kidney ratios, already at early time point will be important in regard to safety concerning kidney toxicity.


Asunto(s)
Aminoácidos/química , Aminoácidos/farmacología , Bombesina/antagonistas & inhibidores , Polietilenglicoles/química , Aminoácidos/metabolismo , Aminoácidos/farmacocinética , Animales , Transporte Biológico , Línea Celular Tumoral , Quelantes/química , Estabilidad de Medicamentos , Femenino , Fluorenos/química , Compuestos Heterocíclicos con 1 Anillo/química , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Ratones , Receptores de Bombesina/metabolismo , Relación Estructura-Actividad , Distribución Tisular
3.
Nat Rev Urol ; 10(4): 235-44, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23507930

RESUMEN

Gastrin releasing peptide (GRP) is a regulatory peptide that acts through its receptor (GRPR) to regulate physiological functions in various organs. GRPR is overexpressed in neoplastic cells of most prostate cancers and some renal cell cancers and in the tumoral vessels of urinary tract cancers. Thus, targeting these tumours with specifically designed GRP analogues has potential clinical application. Potent and specific radioactive, cytotoxic or nonradioactive GRP analogues have been designed and tested in various animal tumour models with the aim of receptor targeting for tumour diagnosis or therapy. All three categories of compound were found suitable for tumour targeting in animal models. The cytotoxic and nonradioactive GRP analogues have not yet shown convincing tumour-reducing effects in human trials; however, the first clinical studies of radioactive GRP analogues--both agonists and antagonists--suggest promising opportunities for both diagnostic tumour imaging and radiotherapy of prostate and other GRPR-expressing cancers.


Asunto(s)
Investigación Biomédica/métodos , Sistemas de Liberación de Medicamentos/métodos , Receptores de Bombesina/antagonistas & inhibidores , Receptores de Bombesina/biosíntesis , Neoplasias Urológicas/tratamiento farmacológico , Neoplasias Urológicas/metabolismo , Animales , Regulación Neoplásica de la Expresión Génica , Humanos
4.
Mol Imaging ; 11(2): 91-8, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22469237

RESUMEN

We prospectively investigated the potential of positron emission tomography (PET) using the somatostatin receptor (SSTR) analogue 68Ga-DOTATATE and 2-deoxy-2[¹8F]fluoro-D-glucose (¹8F-FDG) in diffuse parenchymal lung disease (DPLD). Twenty-six patients (mean age 68.9 ± 11.0 years) with DPLD were recruited for 68Ga-DOTATATE and ¹8F-FDG combined PET/high-resolution computed tomography (HRCT) studies. Ten patients had idiopathic pulmonary fibrosis (IPF), 12 patients had nonspecific interstitial pneumonia (NSIP), and 4 patients had other forms of DPLD. Using PET, the pulmonary tracer uptake (maximum standardized uptake value [SUV(max)]) was calculated. The distribution of PET tracer was compared to the distribution of lung parenchymal changes on HRCT. All patients demonstrated increased pulmonary PET signal with 68Ga-DOTATATE and ¹8F-FDG. The distribution of parenchymal uptake was similar, with both tracers corresponding to the distribution of HRCT changes. The mean SUV(max) was 2.2 ± 0.7 for 68Ga-DOTATATE and 2.8 ± 1.0 (t-test, p  =  .018) for ¹8F-FDG. The mean 68Ga-DOTATATE SUV(max) in IPF patients was 2.5 ± 0.9, whereas it was 2.0 ± 0.7 (p  =  .235) in NSIP patients. The correlation between 68Ga-DOTATATE SUV(max) and gas transfer (transfer factor of the lung for carbon monoxide [TLCO]) was r  =  -.34 (p  =  .127) and r  =  -.49 (p  =  .028) between ¹8F-FDG SUV(max) and TLCO. We provide noninvasive in vivo evidence in humans showing that SSTRs may be detected in the lungs of patients with DPLD in a similar distribution to sites of increased uptake of ¹8F-FDG on PET.


Asunto(s)
Fluorodesoxiglucosa F18 , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Imagen Multimodal/métodos , Tomografía de Emisión de Positrones , Receptores de Somatostatina/metabolismo , Coloración y Etiquetado , Tomografía Computarizada por Rayos X , Anciano , Femenino , Humanos , Neumonías Intersticiales Idiopáticas/diagnóstico por imagen , Fibrosis Pulmonar Idiopática/diagnóstico por imagen , Masculino
5.
ACS Med Chem Lett ; 2(7): 509-14, 2011 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-24900340

RESUMEN

A focused multiply N-methylated library of a cyclic hexapeptidic somatostatin analogue: MK678 cyclo(-MeAYwKVF-) was generated, which resulted in the unexpected observation of an efficacious tetra-N-methylated analogue, cyclo(-MeAYMewMeKVMeF-) with a potent inhibitory action on sensory neuropeptide release in vitro and on acute neurogenic inflammatory response in vivo. The analogue shows selectivity toward somatostatin receptor subtype 2 (sst2). Extensive 2D NMR spectroscopy and molecular dynamics simulation revealed the solution conformation of the analogue, which can be adopted as a lead for the further structure-activity relationship studies targeting neurogenic inflammation.

6.
Bioconjug Chem ; 19(9): 1796-802, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18712900

RESUMEN

Despite the improvements in cancer therapy during the past years, high-grade gliomas and many other types of cancer are still extremely resistant to current forms of therapy. Boron neutron capture therapy (BNCT) provides a promising way to destroy cancer cells without damaging healthy tissue. However, BNCT in practice is still limited due to the lack of boron-containing compounds that selectively deliver boron to cancer cells. Since many neuroendocrine tumors show an overexpression of the somatostatin receptor, it was our aim to synthesize compounds that contain a large number of boron atoms and still show high affinity toward this transmembrane receptor. The synthetic peptide Tyr (3)-octreotate (TATE) was chosen as a high-affinity and internalizing tumor targeting vector (TTV). Novel boron cluster compounds, containing 10 or 20 boron atoms, were coupled to the N-terminus of TATE. The obtained affinity data demonstrate that the use of a spacer between TATE and the closo-borane moiety is the option to avoid a loss of biological affinity of closo-borane conjugated TATE. For the first time, it was shown that closo-borane conjugated regulatory peptides retain high biological affinity and selectivity toward their transmembrane tumor receptors. The results obtained and the improvement of spacer and boron building block chemistry may stimulate new directions for BNCT.


Asunto(s)
Boranos/síntesis química , Terapia por Captura de Neutrón de Boro/métodos , Neoplasias/radioterapia , Péptidos Cíclicos/síntesis química , Animales , Sitios de Unión , Boranos/metabolismo , Boranos/uso terapéutico , Células CHO , Línea Celular , Membrana Celular/química , Membrana Celular/metabolismo , Cricetinae , Cricetulus , Humanos , Neoplasias/tratamiento farmacológico , Péptidos Cíclicos/metabolismo , Péptidos Cíclicos/uso terapéutico
7.
Mod Pathol ; 21(4): 387-95, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18223557

RESUMEN

Gastrointestinal peptide hormone receptors, like somatostatin receptors, are often overexpressed in human cancer, allowing receptor-targeted tumor imaging and therapy. A novel candidate for these applications is the secretin receptor recently identified in pancreatic and cholangiocellular carcinomas. In the present study, secretin receptors were assessed in a non-gastrointestinal tissue, the human lung. Non-small-cell lung cancers (n=26), small-cell lung cancers (n=10), bronchopulmonary carcinoid tumors (n=29), and non-neoplastic lung (n=46) were investigated for secretin receptor protein expression with in vitro receptor autoradiography, using (125)I-[Tyr(10)] rat secretin and for secretin receptor transcripts with RT-PCR. Secretin receptor protein expression was found in 62% of bronchopulmonary carcinoids in moderate to high density, in 12% of non-small cell lung cancers in low density, but not in small cell lung cancers. In tumors found to be secretin receptor positive by autoradiography, RT-PCR revealed transcripts for the wild-type secretin receptor and for novel secretin receptor splice variants. In the non-neoplastic lung, secretin receptor protein expression was observed in low density along the alveolar septa in direct tumor vicinity in cases of acute inflammation, but not in histologically normal lung. In the autoradiographically positive peritumoral lung, RT-PCR showed transcripts for the wild-type secretin receptor and for a secretin receptor spliceoform different from those occurring in lung and gut tumors. In conclusion, secretin receptors are new markers for bronchopulmonary carcinoid tumors, and represent the molecular basis for an in vivo targeting of carcinoid tumors for diagnosis and therapy. Furthermore, secretin receptors may play a role in peritumoral lung pathophysiology. Secretin receptor mis-splicing specifically occurs in tumor and non-tumor lung pathology.


Asunto(s)
Biomarcadores de Tumor/análisis , Tumor Carcinoide/metabolismo , Neoplasias Pulmonares/metabolismo , Receptores Acoplados a Proteínas G/metabolismo , Receptores de la Hormona Gastrointestinal/metabolismo , Autorradiografía , Carcinoma de Pulmón de Células no Pequeñas/metabolismo , Carcinoma de Células Pequeñas/metabolismo , Expresión Génica , Humanos , Pulmón/metabolismo , Isoformas de Proteínas/metabolismo , Receptores Acoplados a Proteínas G/genética , Receptores de la Hormona Gastrointestinal/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Regulación hacia Arriba
8.
J Nucl Med ; 44(10): 1649-54, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14530481

RESUMEN

UNLABELLED: The study aim was to assess the safety, biodistribution, tissue kinetics, and tumor uptake of the (99m)Tc-labeled neurotensin (NT) analog NT-XI. METHODS: Four patients presenting ductal pancreatic adenocarcinoma were studied with (99m)Tc-NT-XI. Patients were followed by scintigraphy up to 4 h and by continued blood and urinary sampling until surgery 18-22 h after injection. Surgical tissue samples were analyzed for radioactivity uptake and NT receptor expression. RESULTS: No side effects were observed on injection of (99m)Tc-NT-XI. Blood biologic half-lives alpha and beta were 35 min (range, 17-62 min) and 230 min (range, 107-383 min), respectively. Repeated whole-body scintigraphy performed in 2 patients showed a single exponential decrease of whole-body activity with half-lives of 101 and 232 min. Tracer elimination was mainly renal, with 92% and 98% of activity counted in urine in the first 20 h. Kidney, liver, spleen, and bone marrow activity uptake was observed in all patients. Tumor was not visualized in the first 3 patients but could be localized by tomoscintigraphy in the pancreas head region of patient 4. In vitro tissue analysis showed high expression of NT receptor in the tumor of patient 4, correlated with the highest tumor radioactivity uptake and the highest tumor-to-fat radioactivity ratio. In vitro receptor expression was also positive in a second patient having a tumor characterized by very low cellularity; however, the remaining 2 tumors lacked NT receptor expression. CONCLUSION: Injection of (99m)Tc-NT-XI was well tolerated. The in vivo tumor uptake appeared specific as it was observed in the 1 patient with a pancreatic tumor that expressed high amounts of NT receptor. The results are compatible with preclinical animal results and in favor of further development of radiolabeled NT analogs for diagnosis or therapy of cancer.


Asunto(s)
Carcinoma Ductal Pancreático/diagnóstico por imagen , Carcinoma Ductal Pancreático/metabolismo , Neurotensina/farmacocinética , Compuestos de Organotecnecio/farmacocinética , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/metabolismo , Recuento Corporal Total , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/metabolismo , Adulto , Anciano , Femenino , Semivida , Humanos , Masculino , Tasa de Depuración Metabólica , Persona de Mediana Edad , Neurotensina/análogos & derivados , Valor Predictivo de las Pruebas , Dosis de Radiación , Radiometría , Cintigrafía , Radiofármacos/farmacocinética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA