1.
Cancer Radiother ; 24(2): 128-134, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32224107

RESUMEN

PURPOSE: Shielding disks play an important role in intraoperative electron radiation therapy, and different designs are currently used in clinical practice. This paper investigates the dosimetric impact of the shielding disk used during intraoperative electron radiation therapy (IOERT). MATERIALS AND METHODS: This paper focuses on the study of four shielding disks types that have been used in our clinic: Aluminum (Al)/Lead (Pb), PMMA/Copper(Cu)/PMMA, Aluminum (Al)/Copper (Cu) and Aluminum (Al)/Steel with their specific thicknesses. The theoretical study was conducted with the EGSnrc Monte Carlo (MC) code. On the other hand, the measurements were carried out with gafchromic films for the four shielding disks for the same setup inside the water phantom. Finally, a comparison of the simulated and measured PDD curves was performed for the four material combinations. RESULTS: MC simulation and gafchromic measurements illustrated that dose values under the four shielding disks types were close to 0, whereas the backscattering enhancement of the disks were 103% with Al/Pb shielding disk, 102% with Al/Steel shielding disk, 102% with Al/Cu shielding disk, 95% with PMMA/Cu/PMMA shielding disk. The PDDs values of the gafchromic films in front of the disks were: 107%, 105%, 104%, and 94% for the Al/Pb, Al/Steel, Al/Cu, and PMMA/Cu/PMMA disks respectively. CONCLUSIONS: The dose values above and under the shielding disks were acceptable for the four studied shielding types. Demonstrated it is possible to use any of them clinically, while the best shielding disk was the Al/Pb since it has minimum thickness and a small backscatter enhancement.


Asunto(s)
Electrones/uso terapéutico , Cuidados Intraoperatorios/instrumentación , Método de Montecarlo , Órganos en Riesgo , Protección Radiológica/instrumentación , Aleaciones , Aluminio , Neoplasias de la Mama/radioterapia , Cobre , Diseño de Equipo , Femenino , Corazón , Humanos , Cuidados Intraoperatorios/métodos , Pulmón , Aceleradores de Partículas , Fantasmas de Imagen , Dosificación Radioterapéutica , Costillas , Dispersión de Radiación , Acero
2.
Cancer Radiother ; 24(4): 288-297, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32179006

RESUMEN

PURPOSE: In context of head-and-neck radiotherapy, this study aims to compare MR image quality according to diagnostic (DIAG) and radiotherapy (RT) setups; and to optimise an MRI-protocol (including 3D T1 and T2-weighted sequences) for dose-planning (based on pseudo-CT generation). MATERIALS AND METHODS: To compare DIAG and RT setups, signal-to-noise-ratio (SNR) and percentage-image-uniformity (PIU) were computed on T1 images of phantoms and volunteers. Influence of the sample conductivity on SNR was quantified using homemade phantoms. To obtain reliable T1 and T2 images for RT-planning, an experimental design was performed on volunteers by using SNR, contrast-to-noise-ratio (CNR) and mean-opinion-score (MOS). Further, pseudo-CTs were generated from 8 patients T2 images with a state-of-art deep-learning method. These pseudo-CTs were evaluated by mean-absolute-error (MAE) and mean-error (ME). RESULTS: SNR was higher for DIAG-setup compared to RT-setup (SNR-ratio=1.3). A clear influence of the conductivity on SNR was observed. PIU was higher for DIAG-setup (38.8%) compared to RT-setup (33.5%). Regarding the protocol optimisation, SNR, CNR, and MOS were 20.6, 6.16, and 3.91 for the optimal T1 sequence. For the optimal T2 sequence, SNR, CNR and MOS were 25.6, 44.46 and 4.0. In the whole head-and-neck area, the mean MAE and ME of the pseudo-CTs were 82.8 and -3.9 HU. CONCLUSION: We quantified the image quality decrease induces by using an RT-setup for head-and-neck radiotherapy. To compensate this decrease, an MRI protocol was optimised by using an experimental design. This protocol of 15minutes provides accurate images which could be used for MRI-dose-planning in clinical practice.


Asunto(s)
Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Imagen por Resonancia Magnética/métodos , Posicionamiento del Paciente/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Relación Señal-Ruido , Diseño de Equipo , Voluntarios Sanos , Humanos , Posicionamiento del Paciente/normas , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/instrumentación , Factores de Tiempo
3.
Phys Med ; 70: 123-132, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32007601

RESUMEN

PURPOSE: This work describes the integration of the M6 Cyberknife in the Moderato Monte Carlo platform, and introduces a machine learning method to accelerate the modelling of a linac. METHODS: The MLC-equipped M6 Cyberknife was modelled and integrated in Moderato, our in-house platform offering independent verification of radiotherapy dose distributions. The model was validated by comparing TPS dose distributions with Moderato and by film measurements. Using this model, a machine learning algorithm was trained to find electron beam parameters for other M6 devices, by simulating dose curves with varying spot size and energy. The algorithm was optimized using cross-validation and tested with measurements from other institutions equipped with a M6 Cyberknife. RESULTS: Optimal agreement in the Monte Carlo model was reached for a monoenergetic electron beam of 6.75 MeV with Gaussian spatial distribution of 2.4 mm FWHM. Clinical plan dose distributions from Moderato agreed within 2% with the TPS, and film measurements confirmed the accuracy of the model. Cross-validation of the prediction algorithm produced mean absolute errors of 0.1 MeV and 0.3 mm for beam energy and spot size respectively. Prediction-based simulated dose curves for other centres agreed within 3% with measurements, except for one device where differences up to 6% were detected. CONCLUSIONS: The M6 Cyberknife was integrated in Moderato and validated through dose re-calculations and film measurements. The prediction algorithm was successfully applied to obtain electron beam parameters for other M6 devices. This method would prove useful to speed up modelling of new machines in Monte Carlo systems.


Asunto(s)
Aprendizaje Automático , Aceleradores de Partículas/instrumentación , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada por Rayos X/métodos , Simulación por Computador , Diseño de Equipo/instrumentación , Humanos , Modelos Biológicos , Método de Montecarlo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/instrumentación , Rayos X
4.
Cancer Radiother ; 23(6-7): 753-760, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31427076

RESUMEN

Imaging provides the basis for radiotherapy. Multi-modality images are used for target delineation (primary tumor and nodes, boost volume) and organs at risk, treatment guidance, outcome prediction, and treatment assessment. Next to anatomical information, more and more functional imaging is being used. The current paper provides a brief overview of the different applications of imaging techniques used in the radiotherapy process, focusing on uncertainties and QA. The paper mainly focuses on PET and MRI, but also provides a short discussion on DCE-CT. A close collaboration between radiology, nuclear medicine and radiotherapy departments provides the key to improve the quality of radiotherapy. Jointly developed imaging protocols (RT position setup, immobilization tools, lasers, flat table…), and QA programs are mandatory. For PET, suitable windowing in consultation with a Nuclear Medicine Physician is crucial (differentiation benign/malignant lesions, artifacts…). A basic knowledge of MRI sequences is required, in such a way that geometrical distortions are easily recognized by all members the RT and RT physics team. If this is not the case, then the radiologist should be introduced systematically in the delineation process and multidisciplinary meetings need to be organized regularly. For each image modality and each image registration process, the associated uncertainties need to be determined and integrated in the PTV margin. When using functional information for dose painting, response assessment or outcome prediction, collaboration between the different departments is even more important. Limitations of imaging based biomarkers (specificity, sensitivity) should be known.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Neoplasias/diagnóstico por imagen , Neoplasias/radioterapia , Garantía de la Calidad de Atención de Salud , Planificación de la Radioterapia Asistida por Computador/métodos , Incertidumbre , Artefactos , Humanos , Imagen por Resonancia Magnética/normas , Imagen Multimodal/normas , Estadificación de Neoplasias , Neoplasias/patología , Fantasmas de Imagen , Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/normas , Tomografía Computarizada por Rayos X/métodos
5.
Cancer Radiother ; 23(4): 281-289, 2019 Jul.
Artículo en Francés | MEDLINE | ID: mdl-31151816

RESUMEN

PURPOSE: Magnetic resonance imaging (MRI) plays an increasing role in radiotherapy dose planning. Indeed, MRI offers superior soft tissue contrast compared to computerized tomography (CT) and therefore could provide a better delineation of target volumes and organs at risk than CT for radiotherapy. Furthermore, an MRI-only radiotherapy workflow would suppress registration errors inherent to the registration of MRI with CT. However, the estimation of the electronic density of tissues using MRI images is still a challenging issue. The purpose of this work was to design and evaluate a pseudo-CT generation method for prostate cancer treatments. MATERIALS AND METHODS: A pseudo-CT was generated for ten prostate cancer patients using an elastic deformation based method. For each patient, dose delivered to the patient was calculated using both the planning CT and the pseudo-CT. Dose differences between CT and pseudo-CT were investigated. RESULTS: Mean dose relative difference in the planning target volume is 0.9% on average and ranges from 0.1% to 1.7%. In organs at risks, this value is 1.8%, 0.8%, 0.8% and 1% on average in the rectum, the right and left femoral heads, and the bladder respectively. CONCLUSION: The dose calculated using the pseudo-CT is very close to the dose calculated using the CT for both organs at risk and PTV. These results confirm that pseudo-CT images generated using the proposed method could be used to calculate radiotherapy treatment doses on MRI images.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador , Anciano , Anciano de 80 o más Años , Humanos , Masculino , Persona de Mediana Edad , Órganos en Riesgo , Dosificación Radioterapéutica , Tomografía Computarizada por Rayos X
6.
Int J Endocrinol ; 2018: 6421243, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29849621

RESUMEN

OBJECTIVES: Information on the efficacy of GH treatment in short SGA children starting their treatment in adolescence is limited. Therefore, adult height (AH), total height gain, and pubertal height gain were evaluated in short SGA children who started GH treatment at pubertal onset. PATIENT AND METHODS: Growth data of 47 short SGA adolescents (22 boys) who started GH treatment at pubertal onset (PUB group) were compared with results from 27 short SGA patients (11 boys) who started GH therapy at least 1 year before pubertal onset (PrePUB group). RESULTS: The PUB group achieved a mean (±SD) total height gain of 0.8 ± 0.7 SDS and an AH of -2.5 ± 0.7 SDS after 4.1 ± 1.1 years of GH treatment with a dosage of 41.8 ± 8.4 µg/kg/day. These results were comparable with those in the PrePUB group, which was treated for a longer duration (5.8 ± 2.1 years), resulting in a total height gain of 1.1 ± 0.7 SDS and an AH of -2.1 ± 1.0 SDS. Multiple regression analysis showed a significantly lower height gain in pubertal patients, females, and patients weighing less at start of GH treatment. An AH above -2 SDS and above the parent-specific lower limit of height was, respectively, reached in 28% and 70% of PUB and 44% and 67% of PrePUB patients (NS). AH SDS was positively correlated with the height SDS at start of GH. CONCLUSIONS: Short SGA adolescents starting GH therapy at an early pubertal stage have a modest and variable height gain. A normal AH can be expected in one third of the patients, especially in those with a smaller height deficit at onset of GH treatment.

7.
Phys Med ; 42: 319-326, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28662849

RESUMEN

PURPOSE: The aim of the present work is to evaluate a semi-automatic prescription and validation system of treatment plans for complex delivery techniques, integrated in a Monte Carlo platform, and to investigate the clinical impact of dose differences due to the calculation algorithms, by assessing the changes in DVH constraints. METHODS: A new prescription module was implemented into the Moderato system, an in-house Monte Carlo platform, with corresponding dose constraints generated depending on the anatomical region and fractionation scheme considered. The platform was tested on 83 cases treated with Cyberknife and Tomotherapy machines, to assess whether dose variations between the re-calculated dose and the Treatment Planning System might impact the dose constraints on the sensitive structures. RESULTS: Dose differences were small (within 3%) between calculation algorithms in most of the thoracic, pelvic and abdominal cases, both for the Cyberknife and Tomotherapy machines. On the other hand, spinal and head and neck treatments presented a few significant dose deviations for constraints on small volumes, such as the optic pathways and the spinal cord. These differences range from -11% to +6%, inducing constraint violations of up to 8% over the dose limit. CONCLUSIONS: The Moderato platform offers an interesting tool for plan quality validation, with a prescription module highlighting crucial features in the structures list, and a Monte Carlo dose re-calculation for complex modern techniques. Due to the high number of warnings appearing in some situations, display optimization is required in practice.


Asunto(s)
Algoritmos , Método de Montecarlo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Radiocirugia , Radioterapia de Intensidad Modulada
8.
Phys Med ; 42: 332-338, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28526235

RESUMEN

Using magnetic resonance imaging (MRI) as the sole imaging modality for patient modeling in radiation therapy (RT) is a challenging task due to the need to derive electron density information from MRI and construct a so-called pseudo-computed tomography (pCT) image. We have previously published a new method to derive pCT images from head T1-weighted (T1-w) MR images using a single-atlas propagation scheme followed by a post hoc correction of the mapped CT numbers using local intensity information. The purpose of this study was to investigate the performance of our method with head zero echo time (ZTE) MR images. To evaluate results, the mean absolute error in bins of 20 HU was calculated with respect to the true planning CT scan of the patient. We demonstrated that applying our method using ZTE MR images instead of T1-w improved the correctness of the pCT in case of bone resection surgery prior to RT (that is, an example of large anatomical difference between the atlas and the patient).


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Imagen por Resonancia Magnética/métodos , Radioterapia Guiada por Imagen/métodos , Algoritmos , Atlas como Asunto , Encéfalo/diagnóstico por imagen , Encéfalo/efectos de la radiación , Encéfalo/cirugía , Neoplasias Encefálicas/cirugía , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Programas Informáticos , Tomografía Computarizada por Rayos X
9.
Phys Med ; 44: 177-187, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28366555

RESUMEN

PURPOSE: The goal of this study is to show that the PTV concept is inconsistent for prescribing lung treatments when using type B algorithms, which take into account lateral electron transport. It is well known that type A dose calculation algorithms are not capable of calculating dose in lung correctly. Dose calculations should be based on type B algorithms. However, the combination of a type B algorithm with the PTV concept leads to prescription inconsistencies. METHODS: A spherical isocentric setup has been simulated, using multiple realistic values for lung density, tumor density and collimator size. Different prescription methods are investigated using Dose-Volume-Histograms (DVH), Dose-Mass-Histograms (DMH), generalized Equivalent Uniform Dose (gEUD) and surrounding isodose percentage. RESULTS: Isodose percentages on the PTV drop down to 50% for small tumors and low lung density. When applying the same PTV prescription to different patients with different lung characteristics, the effective mean dose to the GTV is very different, with factors up to 1.4. The most consistent prescription method seems to be the D50%DMH (PTV) DMH point, but is also limited to tumors with size over 1cm. CONCLUSIONS: Even when using the different prescription methods, the prescription to the PTV is not consistent for type B-algorithm based dose calculations if clinical studies should produce coherent data. This combination leads to patients' GTV with low lung density possibly receiving very high dose compared to patients with higher lung density. The only solution seems to remove the classical PTV concept for type B dose calculations in lung.


Asunto(s)
Neoplasias Pulmonares/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Algoritmos , Humanos , Neoplasias Pulmonares/patología , Dosificación Radioterapéutica , Carga Tumoral
10.
Mol Cell Endocrinol ; 443: 23-31, 2017 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-27940297

RESUMEN

INTRODUCTION: Steroid hormones are involved in lung development, pulmonary inflammation, and lung cancer. Estrogen signaling and exposure may play a role in pulmonary disorders, including COPD. In both genders, estrogens can be generated locally in the lungs and this contributes importantly to the tissue exposure to these steroids. OBJECTIVE: To characterize and assess differences in localization of estrogen receptors and enzymes involved in the local generation of estrogens in COPD. METHODS: Estrogen Receptor alpha (ERα/ESR1), Estrogen Receptor beta (ERß/ESR2) and G-protein-coupled estrogen receptor 1 (GPER) were explored by real-time (RT)-PCR analysis (mRNA expression), immunohistochemistry and western blotting in controls and COPD patients. mRNA expression of the enzymes involved in the local estrogen generation - i.e. aromatase (CYP19A1), 17beta-hydroxysteroid dehydrogenases (17ß-HSDs) 1, 2, 4, 5, 7 and 12, steroid sulfatase (STS) and sulfotransferase (SULT1E1) - were analyzed by RT-PCR. RESULTS: ERα, ERß and GPER were expressed in lung tissue, but no differences were observed between patients and controls. The main enzymes involved in local estrogen generation were also present in both normal and COPD lung tissue. In lungs of COPD patients compared with controls, we observed increased expression of the enzymes 17ß-HSD type 1 and aromatase (positive association), both involved in the local synthesis of active estrogens. CONCLUSION: All ER subtypes are present in the lung. The shift in local mRNA level of estrogen metabolic enzymes suggests that exposure to estrogens is involved in the pathogenesis of COPD.


Asunto(s)
Estradiol/biosíntesis , Enfermedad Pulmonar Obstructiva Crónica/enzimología , Receptor alfa de Estrógeno/genética , Receptor alfa de Estrógeno/metabolismo , Receptor beta de Estrógeno/genética , Receptor beta de Estrógeno/metabolismo , Femenino , Regulación de la Expresión Génica , Humanos , Pulmón/metabolismo , Pulmón/patología , Masculino , Persona de Mediana Edad , Enfermedad Pulmonar Obstructiva Crónica/genética , Enfermedad Pulmonar Obstructiva Crónica/patología , ARN Mensajero/genética , ARN Mensajero/metabolismo , Receptores de Estrógenos/metabolismo , Receptores Acoplados a Proteínas G/metabolismo
11.
Phys Med ; 32(10): 1225-1237, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27659008

RESUMEN

PURPOSE: The main focus of the current paper is the clinical implementation of a Monte Carlo based platform for treatment plan validation for Tomotherapy and Cyberknife, without adding additional tasks to the dosimetry department. METHODS: The Monte Carlo platform consists of C++ classes for the actual functionality and a web based GUI that allows accessing the system using a web browser. Calculations are based on BEAMnrc/DOSXYZnrc and/or GATE and are performed automatically after exporting the dicom data from the treatment planning system. For Cyberknife treatments of moving targets, the log files saved during the treatment (position of robot, internal fiducials and external markers) can be used in combination with the 4D planning CT to reconstruct the actually delivered dose. The Monte Carlo platform is also used for calculation on MRI images, using pseudo-CT conversion. RESULTS: For Tomotherapy treatments we obtain an excellent agreement (within 2%) for almost all cases. However, we have been able to detect a problem regarding the CT Hounsfield units definition of the Toshiba Large Bore CT when using a large reconstruction diameter. For Cyberknife treatments we obtain an excellent agreement with the Monte Carlo algorithm of the treatment planning system. For some extreme cases, when treating small lung lesions in low density lung tissue, small differences are obtained due to the different cut-off energy of the secondary electrons. CONCLUSIONS: A Monte Carlo based treatment plan validation tool has successfully been implemented in clinical routine and is used to systematically validate all Cyberknife and Tomotherapy plans.


Asunto(s)
Radiocirugia/estadística & datos numéricos , Radiocirugia/normas , Planificación de la Radioterapia Asistida por Computador/estadística & datos numéricos , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia de Intensidad Modulada/estadística & datos numéricos , Radioterapia de Intensidad Modulada/normas , Algoritmos , Fenómenos Biofísicos , Simulación por Computador , Femenino , Tomografía Computarizada Cuatridimensional , Humanos , Imagen por Resonancia Magnética , Masculino , Método de Montecarlo , Control de Calidad , Dosificación Radioterapéutica , Programas Informáticos
12.
Biochim Biophys Acta ; 1852(5): 992-1000, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25703138

RESUMEN

The receptor for advanced glycation end products (RAGE) is a multi-ligand receptor. Alternative splicing and enzymatic shedding produce soluble forms that protect against damage by ligands including Advanced Glycation End products (AGEs). A link between RAGE and oxygen levels is evident from studies showing RAGE-mediated injury following hyperoxia. The effect of hypoxia on pulmonary RAGE expression and circulating sRAGE levels is however unknown. Therefore mice were exposed to chronic hypoxia for 21 d and expression of RAGE, sheddases in lungs and circulating sRAGE were determined. In addition, accumulation of AGEs in lungs and expression of the AGE detoxifying enzyme GLO1 and receptors were evaluated. In lung tissue gene expression of total RAGE, variants 1 and 3 were elevated in mice exposed to hypoxia, whereas mRAGE and sRAGE protein levels were decreased. In the hypoxic group plasma sRAGE levels were enhanced. Although the levels of pro-ADAM10 were elevated in lungs of hypoxia exposed mice, the relative amount of the active form was decreased and gelatinase activity unaffected. In the lungs, the RAGE ligand HMGB1 was decreased and of the AGEs, only LW-1 was increased by chronic hypoxia. Gene expression of AGE receptors 2 and 3 was significantly upregulated. Chronic hypoxia is associated with downregulation of pulmonary RAGE protein levels, but a relative increase in sRAGE. These alterations might be part of the adaptive and protective response mechanism to chronic hypoxia and are not associated with AGE formation except for the fluorophore LW-1 which emerges as a novel marker of tissue hypoxia.


Asunto(s)
Expresión Génica , Hipoxia/genética , Pulmón/metabolismo , Receptores Inmunológicos/genética , Proteínas ADAM/genética , Proteínas ADAM/metabolismo , Proteína ADAM10 , Secretasas de la Proteína Precursora del Amiloide/genética , Secretasas de la Proteína Precursora del Amiloide/metabolismo , Animales , Western Blotting , Línea Celular Tumoral , Enfermedad Crónica , Productos Finales de Glicación Avanzada/metabolismo , Proteína HMGB1/metabolismo , Humanos , Hipoxia/sangre , Hipoxia/metabolismo , Subunidad alfa del Factor 1 Inducible por Hipoxia/genética , Subunidad alfa del Factor 1 Inducible por Hipoxia/metabolismo , Lactoilglutatión Liasa/genética , Lactoilglutatión Liasa/metabolismo , Masculino , Proteínas de la Membrana/genética , Proteínas de la Membrana/metabolismo , Ratones Endogámicos C57BL , Isoformas de Proteínas/genética , Isoformas de Proteínas/metabolismo , Receptor para Productos Finales de Glicación Avanzada , Receptores Inmunológicos/sangre , Receptores Inmunológicos/metabolismo , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Solubilidad , Factor A de Crecimiento Endotelial Vascular/genética , Factor A de Crecimiento Endotelial Vascular/metabolismo
13.
Cancer Radiother ; 18(4): 258-63, 2014.
Artículo en Francés | MEDLINE | ID: mdl-25023588

RESUMEN

The principles governing stereotactic body radiation therapy are tight margins and large dose gradients around targets. Every step of treatment preparation and delivery must be evaluated before applying this technique in the clinic. Uncertainties remain in each of these steps: delineation, prescription with the biological equivalent dose, treatment planning, patient set-up taking into account movements, the machine accuracy. The calculation of margins to take into account uncertainties differs from conventional radiotherapy because of the delivery of few fractions and large dose gradients around the target. The quest of high accuracy is complicated by the difficulty to reach it and the lack of consensus regarding the prescription. Many schemes dose/number of fractions are described in clinical studies and there are differences in the way describing the delivered doses. While waiting for the ICRU report dedicated to this technique, it seems desirable to use the quantities proposed in ICRU Report 83 (IMRT) to report the dose distribution.


Asunto(s)
Neoplasias/cirugía , Radiocirugia/métodos , Algoritmos , Humanos , Imagen Multimodal , Neoplasias/patología , Posicionamiento del Paciente , Guías de Práctica Clínica como Asunto , Dosificación Radioterapéutica , Radioterapia Guiada por Imagen
14.
Phys Med Biol ; 58(8): 2445-59, 2013 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-23514761

RESUMEN

Liquid ionization chambers (LICs) offer an interesting tool in the field of small beam dosimetry, allowing better spatial resolution and reduced perturbation effects. However, some aspects remain to be addressed, such as the higher recombination and the effects from the materials of the detector. Our aim was to investigate these issues and their impact. The first step was the evaluation of the recombination effects. Measurements were performed at different SSDs to vary the dose per pulse, and the collection efficiency was obtained. The BEAMnrc code was then used to model the Cyberknife head. Finally, the liquid ionization chamber itself was modelled using the EGSnrc-based code Cavity allowing the evaluation of the influence of the volume and the chamber materials. The liquid ionization charge collection efficiency is approximately 0.98 at 1.5 mGy pulse(-1), the highest dose per pulse that we have measured. Its impact on the accuracy of output factors is less than half a per cent. The detector modelling showed a significant contribution from the graphite electrode, up to 6% for the 5 mm collimator. The dependence of the average electronic mass collision stopping power of iso-octane with beam collimation is negligible and thus has no influence on output factor measurements. Finally, the volume effect reaches 5% for the small 5 mm collimator and becomes much smaller (<0.5%) for diameters above 10 mm. LICs can effectively be used for small beam relative dosimetry as long as adequate correction factors are applied, especially for the electrode and volume effects.


Asunto(s)
Radiometría/instrumentación , Radiocirugia/métodos , Modelos Teóricos
15.
Cancer Radiother ; 16(8): 681-7, 2012 Dec.
Artículo en Francés | MEDLINE | ID: mdl-23182503

RESUMEN

PURPOSE: To observe on ten patients, the changes of different pelvic structures during a Stade IB2-IIB cervix cancer tomotherapy course delivering 60Gy over 5.5 weeks and evaluate the rationale of adaptive treatments. MATERIALS AND METHODS: Each of the six weekly mega voltage CT-scan (MVCT) exams performed the same day of the week were analyzed. The centro-pelvic CTV volume was contoured as well as the organs at risk (OAR). The dose delivered was recalculated while those to 2%, 50% and 98% of the centro-pelvic CTV as well as to 2 cm(3), 10 cm(3) and 50 cm(3) of the OAR were analyzed. RESULTS: The mean decrease in volume of the centro-pelvic CTV was 13% and non-significant (P>0.2). However four tumors decreased from 21% to 42%. This decrease was centripetal. Likewise, the fraction doses to 2%, 50% and 98% were respectively 2.14±0.08Gy, 2.02±0.14 Gy, 1.8±0.34Gy at week 1 and 2.13±0.1 Gy, 2.06±0.12Gy, 1.88±0.24Gy at week 6 (P>0.2). The doses delivered to 2 cm(3), 10 cm(3) and 50 cm(3) of the different OAR did not change at a significant level (P>0.05) too, except the dose to 50 cm(3) of non-sigmoid bowel moving from 1.69±0.16Gy at week 1 to 1.78±0.14Gy at week 6 (P=0.05). CONCLUSION: As a whole, adaptive therapy does not seem mandatory in this population of stages IB2-IIB cancers. A complementary study on more advanced stages is however necessary.


Asunto(s)
Carcinoma de Células Escamosas/radioterapia , Órganos en Riesgo , Radioterapia de Intensidad Modulada/métodos , Neoplasias del Cuello Uterino/radioterapia , Carcinoma de Células Escamosas/patología , Femenino , Humanos , Intestinos/efectos de la radiación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Neoplasias del Cuello Uterino/patología
17.
Phys Med Biol ; 54(9): 2951-69, 2009 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-19384005

RESUMEN

The purpose of this study was the investigation of perturbation factors for microionization chambers in small field dosimetry and the influence of penumbra for different spot sizes. To this purpose, correlated sampling was implemented in the EGSnrc Monte Carlo (MC) user code cavity: CScavity. CScavity was first benchmarked against results in the literature for an NE2571 chamber. An efficiency increase of 17 was attained for the calculation of a realistic chamber perturbation factor in a water phantom. Calculations have been performed for microionization chambers of type PinPoint 31006 and PinPoint 31016 in full BEAMnrc linac simulations. Investigating the physical backgrounds of the differences for these small field settings, perturbation factors have been split up into (1) central electrode perturbation, (2) wall perturbation, (3) air-to-water perturbation (chamber volume air-to-water) and (4) water volume perturbation (water chamber volume to 1 mm(3) voxel). The influence of different spot sizes, position in penumbra, measuring depth and detector geometry on these perturbation factors has been investigated, in a 0.8 x 0.8 cm(2) field setting. p(cel) for the PP31006 steel electrode shows a variation of up to 1% in the lateral position, but only 0.4% for the PP31016 with an Al electrode. The air-to-water perturbation in the optimal scanning direction for both profiles and depth is most influenced by the radiation field, and only to a small extent the chamber geometry. The PP31016 geometry (shorter, larger radius) requires less total perturbation within the central axis of the field, but results in slightly larger variations off axis in the optimal scanning direction. Smaller spot sizes (0.6 mm FWHM) and sharper penumbras, compared to larger spot sizes (2 mm FWHM), result in larger perturbation starting in the penumbra. The longer geometries of the PP31006/14/15 exhibit in the non-optimal scanning direction large variations in total perturbation (p(tot) 1.201(4) (0.6 mm spot, 3 mm off axis, type A MC uncertainty) to 0.803(4) (5 mm off axis)) mainly due to volume perturbation. Therefore in IMRT settings, when the detector is not always in the optimal scanning direction, the PP31016 geometry requires less extreme perturbation (max p(tot) 1.130(3)) and shows less variation. However, these results suggest that small variations in positioning, spot size or MLC result in large differences in perturbation factors. Therefore even these 0.016 cm(3) ionization chambers are limited in their use for a field setting of 0.8 x 0.8 cm(2), as used in this investigation.


Asunto(s)
Radiometría/instrumentación , Aire , Benchmarking , Electrodos , Electrones , Método de Montecarlo , Fotones , Incertidumbre , Agua
18.
Med Phys ; 34(5): 1665-77, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17555248

RESUMEN

The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2 x 2 cm(2)). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the effects of attenuation and scattering close to the bone ribs were not fully taken into account by AAA, and small inhomogeneities may lead to planning errors. Second, AAA and MC were compared for IMRT plans in clinical conditions, i.e., dose calculations in a computed tomography scan of a patient. One ethmoid tumor, one orophaxynx and two lung tumors are presented in this paper. Small differences were found between the dose volume histograms. For instance, a 1.7% difference for the mean planning target volume dose was obtained for the ethmoid case. Since better agreement was achieved for the same plans but in homogeneous conditions, these differences must be attributed to the handling of inhomogeneities by AAA. Therefore, inherent assumptions of the algorithm, principally the assumption of independent depth and lateral directions in the scaling of the kernels, were slightly influencing AAA's validity in inhomogeneities. However, AAA showed a good accuracy overall and a great ability to handle small fields in inhomogeneous media compared to other pencil beam convolution algorithms.


Asunto(s)
Algoritmos , Método de Montecarlo , Aceleradores de Partículas , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Pulmón/diagnóstico por imagen , Neoplasias/diagnóstico por imagen , Neoplasias/radioterapia , Radiografía , Dosificación Radioterapéutica , Costillas/diagnóstico por imagen
19.
Phys Med Biol ; 52(11): 3275-90, 2007 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-17505102

RESUMEN

The purpose of this investigation was the verification of both the measured data and quality of the implementation of the add-on ModuLeaf miniature multileaf collimator (ML mMLC) into the clinical treatment planning system for conformal stereotactic radiosurgery treatment. To this end the treatment head with ML mMLC was modeled in the BEAMnrc Monte Carlo (MC) code. The 6 MV photon beams used in the setup were first benchmarked with a set of measurements. A total ML mMLC transmission of 1.13% of the 10 x 10 cm2 open field dose was measured and reproduced with the BEAMnrc/DOSXYZnrc code. Correspondence between calculated and measured output factors (OFs) was within 2%. Correspondence between MC and measured profiles was within 2% dose and 2 mm distance, only for the smallest 0.5 x 0.5 cm2 field the results were within 3% dose. In the next step, the MC model was compared with Gafchromic film measurements and Pinnacle(3) 7.4 f (convolution superposition algorithm) calculated dose distributions, using a gamma evaluation comparison, for a multi-beam patient setup delivered to a Lucytrade mark phantom. The gamma evaluation of the MC versus Gafchromic film resulted in 3.4% of points not fulfilling gamma

Asunto(s)
Planificación de la Radioterapia Asistida por Computador/métodos , Algoritmos , Simulación por Computador , Relación Dosis-Respuesta en la Radiación , Humanos , Método de Montecarlo , Aceleradores de Partículas , Fantasmas de Imagen , Fotones , Control de Calidad , Dosis de Radiación , Radiometría , Radiocirugia/instrumentación , Dosificación Radioterapéutica , Película para Rayos X
20.
Med Phys ; 33(6): 1678-87, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16872075

RESUMEN

In order to evaluate the performance of denoising algorithms applied to Monte Carlo calculated dose distributions, conventional evaluation methods (rms difference, 1% and 2% difference) can be used. However, it is illustrated that these evaluation methods sometimes underestimate the introduction of bias, since possible bias effects are averaged out over the complete dose distribution. In the present work, a new evaluation method is introduced based on a sliding window superimposed on a difference dose distribution (reference dose-noisy/denoised dose). To illustrate its importance, a new denoising technique (ANRT) is presented based upon a combination of the principles of bilateral filtering and Savitzky-Golay filters. This technique is very conservative in order to limit the introduction of bias in high dose gradient regions. ANRT is compared with IRON for three challenging cases, namely an electron and photon beam impinging on heterogeneous phantoms and two IMRT treatment plans of head-and-neck cancer patients to determine the clinical relevance of the obtained results. For the electron beam case, IRON outperforms ANRT concerning the smoothing capabilities, while no differences in systematic bias are observed. However, for the photon beam case, although ANRT and IRON perform equally well on the conventional evaluation tests (rms difference, 1% and 2% difference), IRON clearly introduces much more bias in the penumbral regions while ANRT seems to introduce no bias at all. When applied to the IMRT patient cases, both denoising methods perform equally well regarding smoothing and bias introduction. This is probably caused by the summation of a large set of different beam segments, decreasing dose gradients compared to a single beam. A reduction in calculation time without introducing large systematic bias can shorten a Monte Carlo treatment planning process considerably and is therefore very useful for the initial trial and error phase of the treatment planning process.


Asunto(s)
Algoritmos , Sesgo , Neoplasias de Cabeza y Cuello/radioterapia , Método de Montecarlo , Planificación de la Radioterapia Asistida por Computador/métodos , Filtración/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/patología , Humanos , Fantasmas de Imagen , Radiografía