Surg Endosc ; 36(1): 300-306, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-33481111

RESUMEN

BACKGROUND: Most complications and adverse events during laparoscopic surgery occur during initial entry into the peritoneal cavity. Among them, preperitoneal insufflation occurs when the insufflation needle is incorrectly placed, and the abdominal wall is insufflated. The objective of this study was to find a range for static pressure which is low enough to allow placement of a Veress needle into the peritoneal space without causing preperitoneal insufflation, yet high enough to separate abdominal viscera from the parietal peritoneum. METHODS: A pressure test was performed on twelve fresh porcine carcasses to determine the minimum preperitoneal insufflation pressure and the minimum initial peritoneal cavity insufflation pressure. Each porcine model had five needle placement categories. One category tested the initial peritoneal cavity insufflation pressure beneath the umbilicus. The four remaining categories tested the preperitoneal insufflation pressure at four different anatomical locations on the abdomen that can be used for initial entry. The minimum initial insufflation pressures from each carcass were then compared to the preperitoneal insufflation pressures to obtain an optimal range for initial insufflation. RESULTS: Increasing the insufflation pressure increased the probability of preperitoneal insufflation. Also, there was a statistically significant difference (p < 0.05) between the initial peritoneal cavity insufflation pressures (8.83 ± 4.19 mmHg) and the lowest preperitoneal pressures (32.54 ± 7.84 mmHg) (mean ± SD). CONCLUSION: Pressures greater than 10 mmHg resulted in initial cavity insufflation and pressures greater than 20 mmHg resulted in preperitoneal insufflation in porcine models. By knowing the minimum pressure required to separate the layers of the abdominal wall, the risk of preperitoneal insufflation can be mitigated while obtaining safe and efficient entry into the peritoneal cavity. The findings in this research are not a guideline for trocar or Veress needle placement, but instead reveal preliminary data which may lead to more studies, technology, etc.


Asunto(s)
Pared Abdominal , Insuflación , Laparoscopía , Pared Abdominal/cirugía , Animales , Insuflación/efectos adversos , Laparoscopía/efectos adversos , Laparoscopía/métodos , Agujas , Cavidad Peritoneal , Neumoperitoneo Artificial/efectos adversos , Neumoperitoneo Artificial/métodos , Porcinos
2.
J Anesth ; 35(4): 543-554, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34061251

RESUMEN

PURPOSE: The COVID-19 pandemic threatens our current ICU capabilities nationwide. As the number of COVID-19 positive patients across the nation continues to increase, the need for options to address ventilator shortages is inevitable. Multi-patient ventilation (MPV), in which more than one patient can use a single ventilator base unit, has been proposed as a potential solution to this problem. To our knowledge, this option has been discussed but remains untested in live patients with differing severity of lung pathology. METHODS: The objective of this study was to address ventilator shortages and patient stacking limitations by developing and validating a modified breathing circuit for two patients with differing lung compliances using simple, off-the-shelf components. A multi-patient ventilator circuit (MPVC) was simulated with a mathematical model and validated with four animal studies. Each animal study had two human-sized pigs: one healthy and one with lipopolysaccharide (LPS) induced ARDS. LPS was chosen because it lowers lung compliance similar to COVID-19. In a previous study, a control group of four pigs was given ARDS and placed on a single patient ventilation circuit (SPVC). The oxygenation of the MPVC ARDS animals was then compared to the oxygenation of the SPVC animals. RESULTS: Based on the comparisons, similar oxygenation and morbidity rates were observed between the MPVC ARDS animals and the SPVC animals. CONCLUSION: As healthcare systems worldwide deal with inundated ICUs and hospitals from pandemics, they could potentially benefit from this approach by providing more patients with respiratory care.


Asunto(s)
COVID-19 , Síndrome de Dificultad Respiratoria , Animales , Humanos , Pandemias , Respiración Artificial , Síndrome de Dificultad Respiratoria/terapia , SARS-CoV-2 , Porcinos , Ventiladores Mecánicos
3.
PLoS One ; 13(11): e0206162, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30462651

RESUMEN

Advancements in wearable technology have facilitated performance monitoring in a number of sports. Figure skating may also benefit from this technology, but the inherent movements present some unique challenges. The purpose of this study was to evaluate the feasibility of using an inertial measurement unit (IMU) to monitor three aspects of figure skating jumping performance: jump count, jump height, and rotation speed. Seven competitive figure skaters, outfitted with a waist-mounted IMU, performed a total of 59 isolated multi-revolution jumps and their competition routines, which consisted of 41 multi-revolution jumps along with spins, footwork, and other skills. The isolated jumps were used to develop a jump identification algorithm, which was tested on the competition routines. Four algorithms to estimate jump height from flight time were then evaluated using calibrated video as a gold standard. The identification algorithm counted 39 of the 41 program jumps correctly, with one false positive. Flight time and jump height errors under 7% and 15% respectively were found using a peak-to-peak scaling algorithm. Rotation speeds up to 1,500°/s were noted, with peak speeds occurring just over halfway between takeoff and landing. Overall, jump monitoring via IMUs may be an efficient aid for figure skaters training multi-revolution jumps.


Asunto(s)
Locomoción/fisiología , Patinación/fisiología , Dispositivos Electrónicos Vestibles , Adolescente , Adulto , Algoritmos , Niño , Femenino , Humanos , Masculino , Rotación , Procesamiento de Señales Asistido por Computador , Factores de Tiempo , Grabación en Video , Adulto Joven