Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 145
Filtrar
1.
Open Forum Infect Dis ; 11(9): ofae515, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39329108

RESUMEN

Background: Staphylococcus aureus bacteremia (SAB) is a high-risk condition associated with high morbidity and mortality. In the presence of cardiac implantable electronic devices (CIEDs), SAB may cause or clinically indicate device infection. We aimed to estimate the 10-year absolute risk of SAB in adult Danish first-time CIED carriers. Secondary aims included identification of risk factors associated with SAB. Methods: A registry-based study utilizing Danish nationwide registers and including consecutive Danish patients undergoing first CIED implantation between 2000 and 2020 was conducted. The primary outcome was first-time SAB after CIED implantation. Results: A total of 87 257 patients with first CIED implantation in the study period were identified (median age, 75 years; 62.6% were male; median follow-up, 3.8 years). Patients with pacemakers (PMs) were older and with more noncardiovascular comorbidities compared to patients with implantable cardioverter defibrillators (ICDs) and cardiac resynchronization therapy devices with or without defibrillator capacity (CRTs). In total, 1366 patients (1.6%) developed SAB. The 10-year absolute risk (95% confidence interval) of SAB was 2.0% (1.9%-2.1%) for PM, 2.6% (2.2%-3.1%) for ICD, and 3.7% (3.0%-4.5%) for CRT. A multivariable Cox analysis identified hemodialysis (hazard ratio [HR], 8.51), SAB before CIED (HR, 2.76), liver disease (HR, 2.35), and carrying a CRT device (HR, 1.68) among the covariates associated with increased risk of SAB. Conclusions: The absolute risk of SAB in Danish CIED carriers increased with more advanced CIED systems. The risk was highest within the first 3 months after CIED implantation and increased with the presence of certain covariates including renal dialysis, SAB before CIED, male sex, and advancing age.

2.
Micromachines (Basel) ; 15(9)2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39337793

RESUMEN

This paper studies the development of piezoelectric energy harvesting for self-powered leadless intracardiac pacemakers. The energy harvester fit inside the battery compartment, assuming that the energy harvester would replace the battery with a smaller rechargeable battery capacity. The power output analysis was derived from the three-dimensional finite element analysis and in vivo heart measurements. A Doppler laser at the anterior basal in the right ventricle directly measured the heart's kinetic motion. Piezoceramics in the cantilevered configuration were studied. The heart motion was periodic but not harmonic and shock-based. This study found that energy can be harvested by applying periodic bio-movements (cardiac motion). The results also showed that the energy harvester can generate 1.1 V voltage. The effect of various geometrical parameters on power generation was studied. This approach offers potential for self-powered implantable medical devices, with the harvested energy used to power devices such as pacemakers.

4.
Europace ; 26(9)2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39345160

RESUMEN

AIMS: The decisions about placing an ICD in a child are more difficult than in an adult due to longer expected lifespan and the complication risk. Young patients gain the most years from ICDs, despite higher risk of device-related complications. The secondary prevention ICD indication is clear, and device is implanted regardless of potential complications. For primary prevention, risk of sudden cardiac death and complications need to be evaluated. We aimed to compare outcomes for primary and secondary prevention ICDs. METHODS AND RESULTS: Retrospective nationwide cohort study including paediatric patients identified from the Danish ICD registry with ICD implanted at an age ≤ 15 from 1982-21. Demographics, complications (composite of device-related infections or lead-failure requiring re-operation, mortality because of arrhythmia, or unknown cause), and mortality were retrieved from medical charts. Endpoint was appropriate therapy (shock or anti-tachycardia pacing for ventricular tachycardia or fibrillation). Of 72 receiving an ICD, the majority had channelopathies (n = 34) or structural heart diseases (n = 28). ICDs were implanted in 23 patients for primary prevention and 49 for secondary prevention, at median ages of 13.8 and 11.6 years (P-value 0.01), respectively. Median follow-up was 9.0 (interquartile ranges: 4.7-13.5) years. The 10-year cumulative incidence of first appropriate therapy was 70%, with complication and inappropriate therapy rates at 41% and 15%, respectively. No difference was observed between prevention groups for all outcomes. Six patients died during follow-up. CONCLUSION: In children, two-thirds are secondary prevention ICDs. Children have higher appropriate therapy and complication rates than adults, while the inappropriate therapy rate was low.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Prevención Primaria , Sistema de Registros , Prevención Secundaria , Humanos , Masculino , Niño , Estudios Retrospectivos , Prevención Secundaria/métodos , Adolescente , Femenino , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Dinamarca/epidemiología , Resultado del Tratamiento , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Factores de Riesgo , Preescolar , Taquicardia Ventricular/terapia , Taquicardia Ventricular/prevención & control , Taquicardia Ventricular/mortalidad , Factores de Tiempo , Factores de Edad , Arritmias Cardíacas/terapia , Arritmias Cardíacas/mortalidad , Fibrilación Ventricular/prevención & control , Fibrilación Ventricular/terapia , Fibrilación Ventricular/mortalidad , Medición de Riesgo
5.
CJC Open ; 6(7): 884-892, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39026619

RESUMEN

Background: Atrial fibrillation (AF) increases the risk of conditions such as ischemic stroke, dementia, and heart failure, and early detection is crucial. In Greenland, ischemic strokes are common, and the prevalences of AF risk factors are increasing. Studies based on 30-second electrocardiograms (ECGs) and diagnosis codes so far have indicated either a low prevalence of AF or a prevalence comparable to that in other Western countries, such as Denmark. However, using short, single-point ECGs may underestimate the true prevalence, as especially paroxysmal AF can be missed. With this study, we aim to estimate the prevalence of AF using 3-5-day continuous Holter recordings among people in Nuuk, the capital of Greenland. Methods: In this cross-sectional study, we estimated the prevalence of AF among the population aged ≥ 50 years in Greenland's capital, Nuuk. We used an ePatch to record continuous ECGs for 3-5 days, and questionnaires to assess demographic data, comorbidities, medication, symptoms, and risk factors for AF. Results: Of 226 participants (62% women), 21 (33% women) had either self-reported AF, AF on the recording, or both, equivalent to a prevalence of 9.3% (confidence interval [CI] 5.8-13.9). The age-stratified prevalence was 7.2% (CI 2.7-15.1) among those aged 50-59 years; 8.8% (CI 4.1-16.1) among those aged 60-69 years; and 18.2% (CI 7.0-35.5) among those aged ≥ 70 years. Conclusions: This study provides a novel insight into AF prevalence in Nuuk, emphasizing the potential underestimation in previous studies. Continuous ECG monitoring revealed a higher prevalence, especially among the younger age groups, urging a reevaluation of diagnostic practices in this unique population.


Contexte: La fibrillation auriculaire augmente le risque d'accidents vasculaires cérébraux (AVC) ischémiques, de démence et d'insuffisance cardiaque. Il est donc essentiel de la dépister rapidement. Au Groenland, les AVC ischémiques sont fréquents, et la prévalence des facteurs de risque de fibrillation auriculaire est à la hausse. Les études reposant sur des électrocardiogrammes (ECG) de 30 secondes et des codes de diagnostic ont jusqu'à présent révélé une faible prévalence de la fibrillation auriculaire ou une prévalence comparable à celle d'autres pays occidentaux, comme le Danemark. Cependant, l'utilisation d'ECG courts à un moment fixe dans le temps peut sous-estimer la prévalence réelle, car la fibrillation auriculaire paroxystique, en particulier, peut passer inaperçue. Cette étude a pour but d'estimer la prévalence de la fibrillation auriculaire en utilisant des enregistrements Holter continus de trois à cinq jours chez des habitants de Nuuk, la capitale du Groenland. Méthodologie: Dans cette étude transversale, nous avons estimé la prévalence de la fibrillation auriculaire dans la population de ≥ 50 ans de Nuuk, la capitale du Groenland. Nous avons utilisé un timbre électronique pour enregistrer des ECG en continu pendant trois à cinq jours, ainsi que des questionnaires pour recueillir les données démographiques et consigner les maladies concomitantes, les médicaments, les symptômes et les facteurs de risque de fibrillation auriculaire. Résultats: Sur 226 participants (dont 62 % étaient des femmes), 21 (33 % de femmes) présentaient, soit une fibrillation auriculaire autodéclarée, soit une fibrillation auriculaire selon l'enregistrement, soit les deux, ce qui correspond à une prévalence de 9,3 % (intervalle de confiance [IC] : 5,8 à 13,9). La prévalence stratifiée en fonction de l'âge était de 7,2 % (IC : 2,7 à 15,1) chez les 50 à 59 ans, de 8,8 % (IC : 4,1 à 16,1) chez les 60 à 69 ans et de 18,2 % (IC : 7,0 à 35,5) chez les 70 ans et plus. Conclusions: Cette étude fournit de nouveaux renseignements sur la prévalence de la fibrillation auriculaire à Nuuk et souligne la prévalence potentiellement sous-estimée dans les études précédentes. La surveillance continue de l'ECG a révélé une prévalence plus élevée, en particulier dans les tranches d'âge plus jeunes, ce qui incite à réévaluer les pratiques de diagnostic utilisées dans cette population particulière.

6.
J Nutr ; 154(9): 2827-2833, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39019166

RESUMEN

BACKGROUND: Omega-3 fatty acids derived from seafood acids may influence cardiac arrhythmogenesis, whereas the role of the major plant-derived omega-3 fatty acid, alpha-linolenic acid (ALA), on atrial fibrillation (AF) is largely unknown. OBJECTIVES: We aimed to investigate the association between ALA intake and risk of incident AF overall and in subjects with a low intake of marine omega-3 fatty acids. METHODS: We followed a total of 54,260 middle-aged men and women enrolled into the Danish Diet, Cancer, and Health cohort for development of AF using nationwide registries. Intake of ALA was assessed using a validated food frequency questionnaire and modeled as a restricted cubic spline. Statistical analyses were conducted using Cox proportional hazards regression. RESULTS: We identified a total of 4902 incident AF events during a median of 16.9 y of follow-up. In multivariable analyses, we observed indications of a statistically nonsignificant inverse association between ALA intake and risk of AF up to an ALA intake of 2.5 g/d, whereas no appreciable association was found for higher intakes of ALA. A statistically significant dose-dependent negative association was found between ALA intake and risk of AF in individuals consuming < 250 mg marine omega-3 fatty acids daily, whereas no association was found in those with a higher intake of marine omega-3 fatty acids. CONCLUSIONS: Intake of ALA was associated with a lower risk of AF in individuals consuming a low intake of marine omega-3 fatty acids. This finding is novel and warrants further investigation.


Asunto(s)
Fibrilación Atrial , Ácidos Grasos Omega-3 , Ácido alfa-Linolénico , Humanos , Masculino , Femenino , Fibrilación Atrial/prevención & control , Fibrilación Atrial/epidemiología , Persona de Mediana Edad , Ácido alfa-Linolénico/administración & dosificación , Dinamarca/epidemiología , Ácidos Grasos Omega-3/administración & dosificación , Factores de Riesgo , Modelos de Riesgos Proporcionales , Alimentos Marinos , Dieta , Estudios Prospectivos , Estudios de Seguimiento , Encuestas y Cuestionarios , Estudios de Cohortes , Incidencia
7.
Artículo en Inglés | MEDLINE | ID: mdl-39078373

RESUMEN

INTRODUCTION AND AIM: Radiotherapy in cancer patients with a pacemaker or an implantable cardioverter defibrillator might damage the device and possibly result in malfunction of the device. We aimed to examine device malfunction and change in lead parameters in this group. METHODS: The medical records of pacemaker/implantable cardioverter defibrillator patients who underwent radiotherapy at Aalborg University Hospital between July 1, 2016, and June 30, 2021, were reviewed. Treatment was planned according to risk of device malfunction, assessed using local guidelines. Bootstrap linear regression was used to identify possible differences in lead parameters depending on beam energy and anatomical location. RESULTS: One hundred nine patients with a pacemaker/implantable cardioverter defibrillator who received a total of 122 radiotherapy courses in the study period were identified. No device malfunctions or significant changes in lead parameters during radiotherapy were observed. Only the left ventricle lead threshold and impedance were found to be significantly different when compared by beam energy; however, these changes were relatively small and unlikely to be of clinical relevance. CONCLUSION: No device malfunction or clinically relevant changes in lead parameters were identified in this study, suggesting that radiotherapy of pacemaker/implantable cardioverter defibrillator patients can be regarded as safe when following relevant safety precautions.

8.
Front Cardiovasc Med ; 11: 1300074, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38807948

RESUMEN

Objectives: Cardiac arrhythmias predict poor outcome after myocardial infarction (MI). We studied if arrhythmia monitoring with an insertable cardiac monitor (ICM) can improve treatment and outcome. Design: BIO|GUARD-MI was a randomized, international open-label study with blinded outcome assessment. Setting: Tertiary care facilities monitored the arrhythmias, while the follow-up remained with primary care physicians. Participants: Patients after ST-elevation (STEMI) or non-ST-elevation MI with an ejection fraction >35% and a CHA2DS2-VASc score ≥4 (men) or ≥5 (women). Interventions: Patients were randomly assigned to receive or not receive an ICM in addition to standard post-MI treatment. Device-detected arrhythmias triggered immediate guideline recommended therapy changes via remote monitoring. Main outcome measures: MACE, defined as a composite of cardiovascular death or acute unscheduled hospitalization for cardiovascular causes. Results: 790 patients (mean age 71 years, 72% male, 51% non-STEMI) of planned 1,400 pts were enrolled and followed for a median of 31.6 months. At 2 years, 39.4% of the device group and 6.7% of the control group had their therapy adapted for an arrhythmia [hazard ratio (HR) = 5.9, P < 0.0001]. Most frequent arrhythmias were atrial fibrillation, pauses and bradycardia. The use of an ICM did not improve outcome in the entire cohort (HR = 0.84, 95%-CI: 0.65-1.10; P = 0.21). In secondary analysis, a statistically significant interaction of the type of infarction suggests a benefit in the pre-specified non-STEMI subgroup. Risk factor analysis indicates that this may be connected to the higher incidence of MACE in patients with non-STEMI. Conclusions: The burden of asymptomatic but actionable arrhythmias is large in post-infarction patients. However, arrhythmia monitoring with an ICM did not improve outcome in the entire cohort. Post-hoc analysis suggests that it may be beneficial in non-STEMI patients or other high-risk subgroups. Clinical Trial Registration: [https://www.clinicaltrials.gov/ct2/show/NCT02341534], NCT02341534.

9.
Open Heart ; 11(1)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38553012

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is the most common sustained arrhythmia and results in a high risk of stroke. The number of immigrants is increasing globally, but little is known about potential differences in AF care across migrant populations. AIM: To investigate if initiation of oral anticoagulation therapy (OAC) differs for patients with incident AF in relation to country of origin. METHODS: A nationwide register-based study covering 1999-2017. AF was defined as a first-time diagnosis of AF and a high risk of stroke. Stroke risk was defined according to guidelines from the European Society of Cardiology (ESC). Poisson regression adjusted for sex, age, socioeconomic position and comorbidity was made to compute incidence rate ratios (IRR) for initiation of OAC. RESULTS: The AF population included 254 586 individuals of Danish origin, 6673 of Western origin and 3757 of non-Western origin. Overall, OAC was initiated within -30/+90 days relative to the AF diagnosis in 50.3% of individuals of Danish origin initiated OAC, 49.6% of Western origin and 44.5% of non-Western origin. Immigrants from non-Western countries had significantly lower adjusted IRR of initiating OAC according to all ESC guidelines compared with patients of Danish origin. The adjusted IRRs ranged from 0.73 (95% CI: 0.66 to 0.80) following the launch of the 2010 ESC guideline to 0.89 (95% CI: 0.82 to 0.97) following the launch of the 2001 ESC guideline. CONCLUSION: Patients with AF with a high risk of stroke of non-Western origin have persistently experienced a lower chance of initiating OAC compared with patients of Danish origin during the last decades.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/epidemiología , Anticoagulantes/efectos adversos , Factores de Riesgo , Comorbilidad , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología
10.
Int J Circumpolar Health ; 83(1): 2311965, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38332615

RESUMEN

This cross-sectional study sought to assess the prevalence of atrial fibrillation (AF) diagnosis in Greenland among various age groups and examine the corresponding quality of care. We collected data from Greenland's electronic medical records and evaluated the quality of care using six internationally recommended indicators, which are: percentage of AF patients with an assessment of smoking status within the previous year, an assessment of body mass index within the previous year, assessment of blood pressure within the previous year, measurement of thyroid stimulating hormone (TSH), treatment with an anticoagulant and percentage of patients with a measurement of serum-creatinine. We found the prevalence of AF among patients aged 20 years or older in Greenland to be 1.75% (95% CI 1.62-1.88). We found an increasing prevalence of AF with age and a greater proportion of men than women until the age of 74 years. Our study suggests that the associated quality of care could be higher as the requirement of only one of the six quality indicators was met. A lack of registration may partly explain this, and initiatives to improve the quality of care are recommended.


Asunto(s)
Fibrilación Atrial , Masculino , Humanos , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Groenlandia/epidemiología , Estudios Transversales , Registros Electrónicos de Salud , Presión Sanguínea/fisiología , Prevalencia
11.
Scand J Public Health ; : 14034948231205822, 2024 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-38179955

RESUMEN

BACKGROUND: Atrial fibrillation and flutter (AF) is the most common sustained arrhythmia with an increasing prevalence in Western countries. However, little is known about AF among immigrants compared to non-immigrants. AIM: To examine the incidence of hospital-diagnosed AF according to country of origin. METHOD: Immigrants were defined as individuals born outside Denmark by parents born outside Denmark. AF was defined as first-time diagnosis of AF. All individuals were followed from the age of 45 years from 1998 to 2017. The analyses were adjusted for sex, age, comorbidity, contact with the general practitioner and socioeconomic variables. Adjustment was conducted using standardised morbidity ratio weights, standardised to the Danish population in a marginal structural model. RESULTS: The study population consisted of 3,489,730 Danish individuals free of AF and 108,914 immigrants free of AF who had emigrated from the 10 most represented countries. A total of 323,005 individuals of Danish origin had an incident hospital diagnosis of AF, among the immigrants 7,300 developed AF. Adjusted hazard rate ratios (HRRs) of AF for immigrants from Iran (0.48 [95%CI:0.35;0.64]), Turkey (0.74 [95%CI:0.67;0.82]) and Bosnia-Herzegovina (0.42 [95%CI:0.22;0.79]) were low compared with Danish individuals. Immigrants from Sweden, Germany and Norway had an adjusted HRR of 1.13 [95%CI:1.03;1.23], 1.12 [95%CI:1.05;1.18] and 1.11 [95%CI:1.03;1.21], respectively (Danish individuals as reference). CONCLUSIONS: Substantial variation in the incidence of hospital-diagnosed AF according to country of origin was observed. The results may reflect true biological differences but could also reflect barriers to AF diagnosis for immigrants. Further efforts are warranted to determine the underlying mechanisms.

12.
Artículo en Inglés | MEDLINE | ID: mdl-38082843

RESUMEN

This paper studies the possibility of heart kinetic motion for designing a self-powered intracardiac leadless pacemaker by piezoelectric energy harvesting. A Doppler laser displacement sensor measures in vivo heart kinetic motion. Cantilevered and four-point bending piezoelectric harvesters are studied under the measured in vivo heart kinetic motion. The heart movement is above 15 mm. The cantilevered and four-point bending harvesters generate a maximum voltage of ~ 0.28 V and 0.8 V, respectively with the measured heart motion with a heart rate of 168 beats per minute. Two DC/DC converters, LTC3588 and MAX17220, combined with full-bridge rectifiers and their start-up performance are tested.Clinical Relevance-This paper analyzed the heart kinetic motion and establishes the piezoelectric energy harvesting for a new era of self-powered leadless pacemakers.


Asunto(s)
Marcapaso Artificial , Corazón , Prótesis e Implantes , Suministros de Energía Eléctrica , Tecnología
13.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38055845

RESUMEN

AIMS: Modern clinical management of patients with an implantable cardioverter defibrillator (ICD) largely consists of remote device monitoring, although a subset is at risk of mental health issues post-implantation. We compared a 12-month web-based intervention consisting of goal setting, monitoring of patients' mental health-with a psychological intervention if needed-psychoeducational support from a nurse, and an online patient forum, with usual care on participants' device acceptance 12 months after implantation. METHODS AND RESULTS: This national, multi-site, two-arm, non-blinded, randomized, controlled, superiority trial enrolled 478 first-time ICD recipients from all 6 implantation centres in Denmark. The primary endpoint was patient device acceptance measured by the Florida Patient Acceptance Survey (FPAS; general score range = 0-100, with higher scores indicating higher device acceptance) 12 months after implantation. Secondary endpoints included symptoms of depression and anxiety. The primary endpoint of device acceptance was not different between groups at 12 months [B = -2.67, 95% confidence interval (CI) (-5.62, 0.29), P = 0.08]. Furthermore, the secondary endpoint analyses showed no significant treatment effect on either depressive [B = -0.49, 95% CI (-1.19; 0.21), P = 0.17] or anxiety symptoms [B = -0.39, 95% CI (-0.96; 0.18), P = 0.18]. CONCLUSION: The web-based intervention as supplement to usual care did not improve patient device acceptance nor symptoms of anxiety and depression compared with usual care. This specific web-based intervention thus cannot be recommended as a standardized intervention in ICD patients.


Asunto(s)
Desfibriladores Implantables , Calidad de Vida , Humanos , Ansiedad/prevención & control , Ansiedad/psicología , Atención a la Salud , Internet , Calidad de Vida/psicología , Encuestas y Cuestionarios
14.
Thromb Res ; 232: 62-69, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37939578

RESUMEN

INTRODUCTION: A high risk of gastrointestinal bleeding has been reported with the use of some direct oral anticoagulants (DOACs). This risk may be of particular concern in individuals with associated anaemia. The aim of this study is to investigate potential differences in the risks of gastrointestinal bleeding and stroke among the four available DOACs in patients with atrial fibrillation (AF) and moderate or severe anaemia. MATERIALS AND METHODS: All Danish patients diagnosed with incident AF who had a baseline haemoglobin measurement and subsequently initiated DOAC therapy between 2012 and 2021 were identified through administrative registries. Only patients with moderate or severe anaemia (N = 7269) were included and evaluated regarding the risk of hospitalization for gastrointestinal bleeding and stroke. Standardized absolute 1-year risks of stroke and gastrointestinal bleeding were calculated from multivariable Cox regression analyses. DOACs were compared pairwise RESULTS: Compared with apixaban, both dabigatran and rivaroxaban were associated with a significantly increased risk of gastrointestinal bleeding with standardized 1-year risk ratios of 1.73 (95 % confidence interval [CI], 1.10-2.35) and 1.56 (95 % CI, 1.18-1.93), respectively, while no significant difference was seen in the comparison of apixaban with edoxaban 1.32 (95 % CI, 0.41-2.32). No significant differences in gastrointestinal bleeding were observed with pairwise comparisons of dabigatran, rivaroxaban and edoxaban. Finally, no significant difference in stroke risk among the four DOACs was observed. CONCLUSION: In AF patients with moderate or severe anaemia, apixaban was associated with a significantly lower risk of gastrointestinal bleeding than dabigatran and rivaroxaban. No significant difference in stroke risk was observed across all four available DOACs.


Asunto(s)
Anemia , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Rivaroxabán/efectos adversos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/diagnóstico , Dabigatrán/efectos adversos , Anticoagulantes/efectos adversos , Hemorragia Gastrointestinal/inducido químicamente , Accidente Cerebrovascular/complicaciones , Piridonas/uso terapéutico , Anemia/complicaciones , Anemia/tratamiento farmacológico , Administración Oral
15.
Artículo en Inglés | MEDLINE | ID: mdl-37682525

RESUMEN

BACKGROUND AND AIM: There are a paucity of studies investigating workforce affiliation in connection with first-time ICD-implantation. This study explored workforce affiliation and risk markers associated with not returning to work in patients with ICDs. METHODS: Using the nationwide Danish registers, patients with a first-time ICD-implantation between 2007-2017 and of working age (30-65 years) were identified. Descriptive statistic and logistic regression models were used to describe workforce affiliation and to estimate risk markers associated with not returning to work, respectively. All analyses were stratified by indication for implantation (primary and secondary prevention). RESULTS: Of the 4,659 ICD-patients of working age, 3,300 patients (71%) were members of the workforce (employed, on sick leave or unemployed) (primary: 1428 (43%); secondary:1872 (57%)). At baseline, 842 primary and 1477 secondary prevention ICD-patients were employed. Of those employed at baseline, 81% primary and 75% secondary prevention ICD-patients returned to work within one-year, whereof more than 80% remained employed the following year. Among patients receiving sick leave benefits at baseline, 25% were employed after one-year. Risk markers of not returning to work were 'younger age' in primary prevention ICD-patients, while 'female sex', 'LVEF ≤40', 'lower income' and '≥3 comorbidities' were risk markers in secondary prevention ICD-patients. Lower educational level was a risk marker in both patient groups. CONCLUSIONS: High return-to-work proportions following ICD-implantation, with a subsequent high level of employment maintenance were found. Several significant risk markers of not returning to work were identified including 'lower educational level', that posed a risk in both patient groups.Trial registration number: Capital Region of Denmark, P-2019-051.

16.
J Clin Med ; 12(16)2023 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-37629419

RESUMEN

A standardized examination regime for ischemic stroke (IS) patients was implemented in Greenland in 2010. Prevalence of atrial fibrillation (AF) of 32% was found among discharged IS patients from 2011 to 2012, and our study aims to estimate the use of Holter ECGs for AF diagnostics and the current prevalence of AF among IS patients in Greenland. Patients discharged from Queen Ingrid's Hospital in Nuuk between 2016 and 2021 with an ICD-10 diagnosis of IS or stroke without specification were included. Data on Holter recordings, age, gender, medical treatment with rivaroxaban or warfarin, and ICD-10 and ICPC codes for AF were extracted for each patient. The overall incidence of IS from 2016 to 2021 was 133/100,000 and unchanged since 2012. Sixty-eight of the study's IS patients (14.5%) had AF, and 46% of IS patients with Holter data accessible had a recording according to international recommendations. Our results indicate that fewer IS patients in Greenland have AF than previously. However, the insufficient use of Holter as a diagnostic tool may explain part of the drop, as well as improved preventive treatment with rivaroxaban among AF patients in Greenland. Regardless, IS remains common, and a focus on diagnostics and preventable risk factors should be maintained.

17.
Eur Heart J ; 44(40): 4246-4255, 2023 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-37638973

RESUMEN

BACKGROUND AND AIMS: High percentages of atrial pacing have been associated with an increased risk of atrial fibrillation. This study is aimed at evaluating whether atrial pacing minimization in patients with sinus node dysfunction reduces the incidence of atrial fibrillation. METHODS: In a nationwide, randomized controlled trial, 540 patients with sinus node dysfunction and an indication for first pacemaker implantation were assigned to pacing programmed to a base rate of 60 bpm and rate-adaptive pacing (DDDR-60) or pacing programmed to a base rate of 40 bpm without rate-adaptive pacing (DDD-40). Patients were followed on remote monitoring for 2 years. The primary endpoint was time to first episode of atrial fibrillation longer than 6 min. Secondary endpoints included longer episodes of atrial fibrillation, and the safety endpoint comprised a composite of syncope or presyncope. RESULTS: The median percentage of atrial pacing was 1% in patients assigned to DDD-40 and 49% in patients assigned to DDDR-60. The primary endpoint occurred in 124 patients (46%) in each treatment group (hazard ratio [HR] 0.97, 95% confidence interval [CI] 0.76-1.25, P = .83). There were no between-group differences in atrial fibrillation exceeding 6 or 24 h, persistent atrial fibrillation, or cardioversions for atrial fibrillation. The incidence of syncope or presyncope was higher in patients assigned to DDD-40 (HR 1.71, 95% CI 1.13-2.59, P = .01). CONCLUSIONS: Atrial pacing minimization in patients with sinus node dysfunction does not reduce the incidence of atrial fibrillation. Programming a base rate of 40 bpm without rate-adaptive pacing is associated with an increased risk of syncope or presyncope.

19.
Sci Rep ; 13(1): 11318, 2023 07 13.
Artículo en Inglés | MEDLINE | ID: mdl-37443134

RESUMEN

Cardiac autonomic neuropathy (CAN), widely assessed by heart rate variability (HRV), is a common complication of long-term diabetes. We hypothesized that HRV dynamics during tonic cold pain in individuals with type 1 diabetes mellitus (T1DM) could potentially demask CAN. Forty-eight individuals with long-term T1DM and distal symmetrical polyneuropathy and 21 healthy controls were included. HRV measures were retrieved from 24-h electrocardiograms. Moreover, ultra-short-term HRV recordings were used to assess the dynamic response to the immersion of the hand into 2 °C cold water for 120 s. Compared to healthy, the T1DM group had expectedly lower 24-h HRV measures for most components (p < 0.01), indicating dysautonomia. In the T1DM group, exposure to cold pain caused diminished sympathetic (p < 0.001) and adynamic parasympathetic (p < 0.01) HRV responses. Furthermore, compared to healthy, cold pain exposure caused lower parasympathetic (RMSSD: 4% vs. 20%; p = 0.002) and sympathetic responses (LF: 11% vs. 73%; p = 0.044) in the T1MD group. QRISK3-scores are negatively correlated with HRV measures in 24-h and ultra-short-term recordings. In T1DM, an attenuated sympathovagal response was shown as convincingly adynamic parasympathetic responses and diminished sympathetic adaptability, causing chronometric heart rhythm and rigid neurocardiac regulation threatening homeostasis. The findings associate with an increased risk of cardiovascular disease, emphasizing clinical relevance.


Asunto(s)
Diabetes Mellitus Tipo 1 , Polineuropatías , Disautonomías Primarias , Humanos , Diabetes Mellitus Tipo 1/complicaciones , Sistema Nervioso Autónomo/fisiología , Corazón , Disautonomías Primarias/etiología , Frecuencia Cardíaca/fisiología
20.
Europace ; 25(6)2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37335977

RESUMEN

AIMS: To date, potential differences in outcomes for immigrants and non-immigrants with a cardiac resynchronization therapy (CRT), in a European setting, remain underutilized and unknown. Hence, we examined the efficacy of CRT measured by heart failure (HF)-related hospitalizations and all-cause mortality among immigrants and non-immigrants. METHODS AND RESULTS: All immigrants and non-immigrants who underwent first-time CRT implantation in Denmark (2000-2017) were identified from nationwide registries and followed for up to 5 years. Differences in HF related hospitalizations and all-cause mortality were evaluated by Cox regression analyses. From 2000 to 2017, 369 of 10 741 (3.4%) immigrants compared with 7855 of 223 509 (3.5%) non-immigrants with a HF diagnosis underwent CRT implantation. The origins of the immigrants were Europe (61.2%), Middle East (20.1%), Asia-Pacific (11.9%), Africa (3.5%), and America (3.3%). We found similar high uptake of HF guideline-directed pharmacotherapy before and after CRT and a consistent reduction in HF-related hospitalizations the year before vs. the year after CRT (61% vs. 39% for immigrants and 57% vs. 35% for non-immigrants). No overall difference in 5-year mortality among immigrants and non-immigrants was seen after CRT [24.1% and 25.8%, respectively, P-value = 0.50, hazard ratio (HR) = 1.2, 95% confidence interval (CI): 0.8-1.7]. However, immigrants of Middle Eastern origin had a higher mortality rate (HR = 2.2, 95% CI: 1.2-4.1) compared with non-immigrants. Cardiovascular causes were responsible for the majority of deaths irrespective of immigration status (56.7% and 63.9%, respectively). CONCLUSION: No overall differences in efficacy of CRT in improving outcomes between immigrants and non-immigrants were identified. Although numbers were low, a higher mortality rate among immigrants of Middle Eastern origin was identified compared with non-immigrants.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/métodos , Resultado del Tratamiento , Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Modelos de Riesgos Proporcionales , Desfibriladores Implantables/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA