Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Nucl Med ; 58(8): 1264-1269, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28360212

RESUMEN

The purpose of this study was to describe baseline 18F-FDG PET voxel characteristics in pediatric diffuse intrinsic pontine glioma (DIPG) and to correlate these metrics with baseline MRI apparent diffusion coefficient (ADC) histogram metrics, progression-free survival (PFS), and overall survival. Methods: Baseline brain 18F-FDG PET and MRI scans were obtained in 33 children from Pediatric Brain Tumor Consortium clinical DIPG trials. 18F-FDG PET images, postgadolinium MR images, and ADC MR images were registered to baseline fluid attenuation inversion recovery MR images. Three-dimensional regions of interest on fluid attenuation inversion recovery MR images and postgadolinium MR images and 18F-FDG PET and MR ADC histograms were generated. Metrics evaluated included peak number, skewness, and kurtosis. Correlation between PET and MR ADC histogram metrics was evaluated. PET pixel values within the region of interest for each tumor were plotted against MR ADC values. The association of these imaging markers with survival was described. Results: PET histograms were almost always unimodal (94%, vs. 6% bimodal). None of the PET histogram parameters (skewness or kurtosis) had a significant association with PFS, although a higher PET postgadolinium skewness tended toward a less favorable PFS (hazard ratio, 3.48; 95% confidence interval [CI], 0.75-16.28 [P = 0.11]). There was a significant association between higher MR ADC postgadolinium skewness and shorter PFS (hazard ratio, 2.56; 95% CI, 1.11-5.91 [P = 0.028]), and there was the suggestion that this also led to shorter overall survival (hazard ratio, 2.18; 95% CI, 0.95-5.04 [P = 0.067]). Higher MR ADC postgadolinium kurtosis tended toward shorter PFS (hazard ratio, 1.30; 95% CI, 0.98-1.74 [P = 0.073]). PET and MR ADC pixel values were negatively correlated using the Pearson correlation coefficient. Further, the level of PET and MR ADC correlation was significantly positively associated with PFS; tumors with higher values of ADC-PET correlation had more favorable PFS (hazard ratio, 0.17; 95% CI, 0.03-0.89 [P = 0.036]), suggesting that a higher level of negative ADC-PET correlation leads to less favorable PFS. A more significant negative correlation may indicate higher-grade elements within the tumor leading to poorer outcomes. Conclusion:18F-FDG PET and MR ADC histogram metrics in pediatric DIPG demonstrate different characteristics with often a negative correlation between PET and MR ADC pixel values. A higher negative correlation is associated with a worse PFS, which may indicate higher-grade elements within the tumor.


Asunto(s)
Neoplasias del Tronco Encefálico/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Glioma/diagnóstico por imagen , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Adolescente , Neoplasias del Tronco Encefálico/metabolismo , Niño , Preescolar , Difusión , Supervivencia sin Enfermedad , Femenino , Glioma/metabolismo , Humanos , Masculino , Estudios Retrospectivos , Adulto Joven
3.
Neuro Oncol ; 18(5): 725-34, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26487690

RESUMEN

BACKGROUND: Diffuse intrinsic pontine glioma (DIPG) is associated with poor survival regardless of therapy. We used volumetric apparent diffusion coefficient (ADC) histogram metrics to determine associations with progression-free survival (PFS) and overall survival (OS) at baseline and after radiation therapy (RT). METHODS: Baseline and post-RT quantitative ADC histograms were generated from fluid-attenuated inversion recovery (FLAIR) images and enhancement regions of interest. Metrics assessed included number of peaks (ie, unimodal or bimodal), mean and median ADC, standard deviation, mode, skewness, and kurtosis. RESULTS: Based on FLAIR images, the majority of tumors had unimodal peaks with significantly shorter average survival. Pre-RT FLAIR mean, mode, and median values were significantly associated with decreased risk of progression; higher pre-RT ADC values had longer PFS on average. Pre-RT FLAIR skewness and standard deviation were significantly associated with increased risk of progression; higher pre-RT FLAIR skewness and standard deviation had shorter PFS. Nonenhancing tumors at baseline showed higher ADC FLAIR mean values, lower kurtosis, and higher PFS. For enhancing tumors at baseline, bimodal enhancement histograms had much worse PFS and OS than unimodal cases and significantly lower mean peak values. Enhancement in tumors only after RT led to significantly shorter PFS and OS than in patients with baseline or no baseline enhancement. CONCLUSIONS: ADC histogram metrics in DIPG demonstrate significant correlations between diffusion metrics and survival, with lower diffusion values (increased cellularity), increased skewness, and enhancement associated with shorter survival, requiring future investigations in large DIPG clinical trials.


Asunto(s)
Neoplasias del Tronco Encefálico/patología , Glioma/patología , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias del Tronco Encefálico/mortalidad , Neoplasias del Tronco Encefálico/radioterapia , Niño , Imagen de Difusión por Resonancia Magnética , Progresión de la Enfermedad , Supervivencia sin Enfermedad , Femenino , Glioma/mortalidad , Glioma/radioterapia , Humanos , Estimación de Kaplan-Meier , Masculino , Pronóstico
4.
Acad Radiol ; 22(3): 363-9, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25435183

RESUMEN

RATIONALE AND OBJECTIVES: Magnetic resonance diffusion imaging can characterize physiologic characteristics of pediatric brain tumors used to assess therapy response. The purpose of this study was to assess the variability of the apparent diffusion coefficient (ADC) along z-axis of scanners in the multicenter Pediatric Brain Tumor Consortium (PBTC). MATERIALS AND METHODS: Ice-water diffusion phantoms for each PBTC site were distributed with a specific diffusion imaging protocol. The phantom was scanned four successive times to 1) confirm water in the tube reached thermal equilibrium and 2) allow for assessment of intra-examination ADC repeatability. ADC profiles across slice positions for each vendor and institution combination were characterized using linear regression modeling with a quadratic fit. RESULTS: Eleven sites collected data with a high degree of compliance to the diffusion protocol for each scanner. The mean ADC value at slice position zero for vendor A was 1.123 × 10(-3) mm(2)/s, vendor B was 1.0964 × 10(-3) mm(2)/s, and vendor C was 1.110 × 10(-3) mm(2)/s. The percentage coefficient of variation across all sites was 0.309% (standard deviation = 0.322). The ADC values conformed well to a second-order polynomial along the z-axis, (ie, following a linear model pattern with quadratic fit) for vendor-institution combinations and across vendor-institution combinations as shown in the longitudinal model. CONCLUSIONS: Assessment of the variability of diffusion metrics is essential for establishing the validity of using these quantitative metrics in multicenter trials. The low variability in ADC values across vendors and institutions and validates the use of ADC as a quantitative tumor marker in pediatric multicenter trials.


Asunto(s)
Neoplasias Encefálicas/diagnóstico , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Niño , Humanos , Hielo , Reproducibilidad de los Resultados , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA