Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.332
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38693291

RESUMEN

BACKGROUND: Early mobilization after tendon surgery is crucial to avoid commonly observed postoperative soft tissue adhesions. Recently, a new suture was introduced (DYNACORD; DC) with a salt-infused silicone core designed to minimize laxity and preserve consistent tissue approximation in order to avoid gap formation and allow early mobilization. AIMS: To compare the biomechanical competence of DC against a conventional high strength suture (FiberWire; FW) in a human cadaveric tendon transfer model with an early rehabilitation protocol. METHODS: Sixteen tendon transfers (flexor digitorum superficialis (FDS) IV to flexor pollicis longus (FPL)) were performed in 8 pairs human cadaveric forearms using either DC or FW. Markings were set 0.8 cm proximally and 0.7 cm distally to the level of the interweaving zone of the transfer. All specimens underwent repetitive thumb flexion against resistance in 9 intermittent series of 300 cycles each, simulating an aggressive postoperative rehabilitation protocol. After each series, the distance of the proximal marker to the interweaving zone (proximal), the length of the interweaving zone (intermediate) and the distance of the distal marker to the interweaving zone (distal) were measured. RESULTS: Pooled data over all nine series, normalized to the immediate postoperative status, demonstrated no significant differences between FW and DC (p ≥ 0.355) for the proximal and distal markers. However, at the intermediate zone, DC was associated with significant length shortening (p < 0.001) compared to FW without significant length changes (p = 0.351). Load to catastrophic failure demonstrated significant higher forces in FW (p = 0.011). Nevertheless, due to failure mainly proximal or distal of the transfer zone, these loads are not informative. CONCLUSION: From a biomechanical perspective, DC preserved tissue approximation and might be considered as a valid alternative to conventional high-strength sutures in tendon transfer surgery. DC might allow for a shorter interweaving zone and a more aggressive early postoperative rehabilitation program, possibly avoiding commonly observed postoperative soft tissue adhesions and stiffness.

2.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 864-871, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38454816

RESUMEN

PURPOSE: To investigate the forces on a medial collateral ligament (MCL) reconstruction (MCLR) relative to the valgus alignment of the knee. METHODS: Eight fresh-frozen human cadaveric knees were subjected to dynamic valgus loading at 400 N using a custom-made kinematics rig. After resection of the superficial medial collateral ligament, a single-bundle MCLR with a hamstring tendon autograft was performed. A medial opening wedge distal femoral osteotomy was performed and fixed with an external fixator to gradually adjust the alignment in 5° increments from 0° to 10° valgus. For each degree of valgus deformity, the resulting forces acting on the MCLR were measured through a force sensor and captured in 15° increments from 0° to 60° of knee flexion. RESULTS: Irrespective of the degree of knee flexion, increasing valgus malalignment resulted in significantly increased forces acting on the MCLR compared to neutral alignment (p < 0.05). Dynamic loading at 5° valgus resulted in increased forces on the MCLR at all flexion angles ranging between 16.2 N and 18.5 N (p < 0.05 from 0° to 30°; p < 0.01 from 45° to 60°). A 10° valgus malalignment further increased the forces on the MCLR at all flexion angles ranging between 29.4 N and 40.0 N (p < 0.01 from 0° to 45°, p < 0.05 at 60°). CONCLUSION: Valgus malalignment of the knee caused increased forces acting on the reconstructed MCL. In cases of chronic medial instabilities accompanied by a valgus deformity ≥ 5°, a realigning osteotomy should be considered concomitantly to the MCLR to protect the graft and potentially reduce graft failures. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Ligamentos Colaterales , Tendones Isquiotibiales , Humanos , Cadáver , Articulación de la Rodilla/cirugía , Fenómenos Biomecánicos , Ligamentos Colaterales/cirugía
3.
J Bone Joint Surg Am ; 106(9): 809-816, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38377221

RESUMEN

BACKGROUND: The current literature lacks recommendations regarding surgical approaches to best visualize and reduce Hoffa fractures. The aims of this study were to (1) define surgical corridors to the posterior portions of the lateral and medial femoral condyles and (2) compare the articular surface areas visible with different approaches. METHODS: Eight fresh-frozen human cadaveric knees (6 male and 2 female donors; mean age, 68.2 ± 10.2 years) underwent dissection simulating 6 surgical approaches to the distal femur. The visible articular surface areas for each approach were marked using an electrocautery device and subsequently analyzed using image-processing software. The labeled areas of each femoral condyle were statistically compared. RESULTS: At 30° of flexion, visualization of the posterior portions of the lateral and medial femoral condyles was not possible by lateral and medial parapatellar approaches, as only the anterior 29.4% ± 2.1% of the lateral femoral condyle and 25.6% ± 2.8% of the medial condyle were exposed. Visualization of the lateral femoral condyle was limited by the posterolateral ligamentous structures, hence a posterolateral approach only exposed its central (13.1% ± 1.3%) and posterior (12.4% ± 1.1%) portions. Posterolateral extension by an osteotomy of the lateral femoral epicondyle significantly improved the exposure to 53.4% ± 2.7% and, when combined with a Gerdy's tubercle osteotomy, to 70.9% ± 4.1% (p < 0.001). For the posteromedial approach, an arthrotomy between the anteromedial retinaculum and the superficial medial collateral ligament, and one between the posterior oblique ligament and the medial gastrocnemius tendon, allowed visualization of the central (13.5% ± 2.2%) and the posterior (14.6% ± 2.3%) portions of the medial femoral condyle, while a medial femoral epicondyle osteotomy significantly improved visualization to 66.1% ± 5.5% (p < 0.001). CONCLUSIONS: Visualization of the posterior portions of the femoral condyles is limited by the specific anatomy of each surgical corridor. Extension by osteotomy of the femoral epicondyles and Gerdy's tubercle significantly improved articular surface exposure of the femoral condyles. CLINICAL RELEVANCE: Knowledge of the surgical approach-specific visualization of the articular surface of the femoral condyles might be helpful to properly reduce small Hoffa fragments.


Asunto(s)
Cadáver , Fracturas del Fémur , Humanos , Femenino , Masculino , Anciano , Fracturas del Fémur/cirugía , Articulación de la Rodilla/cirugía , Persona de Mediana Edad , Fémur/cirugía , Fémur/anatomía & histología , Anciano de 80 o más Años , Disección/métodos
4.
J Control Release ; 364: 159-173, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37866403

RESUMEN

Bacteriophage (phage) therapy has shown promise in treating fracture-related infection (FRI); however, questions remain regarding phage efficacy against biofilms, phage-antibiotic interaction, administration routes and dosing, and the development of phage resistance. The goal of this study was to develop a dual antibiotic-phage delivery system containing hydrogel and alginate microbeads loaded with a phage cocktail plus meropenem and evaluate efficacy against muti-drug resistant Pseudomonas aeruginosa. Two phages (FJK.R9-30 and MK.R3-15) displayed enhanced antibiotic activity against P. aeruginosa biofilms when tested in combination with meropenem. The antimicrobial activity of both antibiotic and phage was retained for eight days at 37 °C in dual phage and antibiotic loaded hydrogel with microbeads (PA-HM). In a mouse FRI model, phages were recovered from all tissues within all treatment groups receiving dual PA-HM. Moreover, animals that received the dual PA-HM either with or without systemic antibiotics had less incidence of phage resistance and less serum neutralization compared to phages in saline. The dual PA-HM could reduce bacterial load in soft tissue when combined with systemic antibiotics, although the infection was not eradicated. The use of alginate microbeads and injectable hydrogel for controlled release of phages and antibiotics, leads to the reduced development of phage resistance and lower exposure to the adaptive immune system, which highlights the translational potential of the dual PA-HM. However, further optimization of phage therapy and its delivery system is necessary to achieve higher bacterial killing activity in vivo in the future.


Asunto(s)
Bacteriófagos , Infecciones por Pseudomonas , Animales , Ratones , Pseudomonas aeruginosa , Meropenem/uso terapéutico , Alginatos , Microesferas , Infecciones por Pseudomonas/tratamiento farmacológico , Infecciones por Pseudomonas/microbiología , Antibacterianos/uso terapéutico , Biopelículas
5.
Clin Biomech (Bristol, Avon) ; 109: 106095, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37757678

RESUMEN

BACKROUND: The beneficial effects of unrestricted postoperative full weight bearing for elderly patients suffering hip fractures have been demonstrated. However, there is still existing disagreement regarding acetabular fractures.The aim of this biomechanical study was to evaluate the initial load bearing capabilities of different fixation constructs of anterior column fractures (ACFs) in osteoporotic bone. METHODS: Artificial pelvises with ACFs were assigned to three groups (n = 8) and fixed with either a 7.3 mm partially threaded antegrade cannulated screw (group AASS), an anteriorly placed 3.5 mm plate (group AAPF), or a press-fit acetabular cup with screw augmentation (group AACF). All specimens underwent ramped loading from 20 N preload to 200 N at a rate of 18 N/s, followed by progressively increasing cyclic testing at 2 Hz until failure performed at a rate of 0.05 N/cycle. Relative displacements of the bone fragments were monitored by motion tracking. FINDINGS: Initial stiffness (N/mm) was 118.5 ± 34.3 in group AASS, 100.4 ± 57.5 in group AAPF, and 92.9 ± 44.0 in group AACF, with no significant differences between the groups, p = 0.544. Cycles to failure were significantly higher in groups AACF (8364 ± 2243) and AAPF (7827 ± 2881) compared to group AASS (4440 ± 2063), p ≤ 0.041. INTERPRETATION: From a biomechanical perspective, the minimally invasive cup fixation with screw augmentation demonstrated comparable stability to plate osteosynthesis of ACFs in osteoporotic bone. The results of the present study do not allow to conclusively answer whether immediate full weight bearing following cup fixation shall be allowed. Given its similar performance to plate osteosynthesis, this remains rather an utopic wish and a more conservative approach deems more reasonable.


Asunto(s)
Fracturas Óseas , Fracturas de Cadera , Osteoporosis , Fracturas de la Columna Vertebral , Humanos , Anciano , Acetábulo/cirugía , Estudios de Factibilidad , Fenómenos Biomecánicos , Fracturas Óseas/cirugía , Fijación Interna de Fracturas/métodos , Fracturas de Cadera/cirugía , Tornillos Óseos , Placas Óseas
6.
Medicina (Kaunas) ; 59(9)2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37763723

RESUMEN

Background and Objectives: Unstable proximal humerus fractures (PHFs) with metaphyseal defects-weakening the osteosynthesis construct-are challenging to treat. A new augmentation technique of plated complex PHFs with metaphyseal defects was recently introduced in the clinical practice. This biomechanical study aimed to analyze the stability of plated unstable PHFs augmented via implementation of this technique versus no augmentation. Materials and Methods: Three-part AO/OTA 11-B1.1 unstable PHFs with metaphyseal defects were created in sixteen paired human cadaveric humeri (average donor age 76 years, range 66-92 years), pairwise assigned to two groups for locked plate fixation with identical implant configuration. In one of the groups, six-milliliter polymethylmethacrylate bone cement with medium viscosity (seven minutes after mixing) was placed manually through the lateral window in the defect of the humerus head after its anatomical reduction to the shaft and prior to the anatomical reduction of the greater tuberosity fragment. All specimens were tested biomechanically in a 25° adduction, applying progressively increasing cyclic loading at 2 Hz until failure. Interfragmentary movements were monitored by motion tracking and X-ray imaging. Results: Initial stiffness was not significantly different between the groups, p = 0.467. Varus deformation of the humerus head fragment, fracture displacement at the medial humerus head aspect, and proximal screw migration and cut-out were significantly smaller in the augmented group after 2000, 4000, 6000, 8000 and 10,000 cycles, p ≤ 0.019. Cycles to 5° varus deformation of the humerus head fragment-set as a clinically relevant failure criterion-and failure load were significantly higher in the augmented group, p = 0.018. Conclusions: From a biomechanical standpoint, augmentation with polymethylmethacrylate bone cement placed in the metaphyseal humerus head defect of plated unstable PHFs considerably enhances fixation stability and can reduce the risk of postoperative complications.

7.
Mater Today Bio ; 22: 100775, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37674778

RESUMEN

Herein we show an accessible technique based on Faraday waves that assist the rapid assembly of osteoinductive ß-Tricalcium phosphate (ß-TCP) particles as well as human osteoblast pre-assembled in spheroids. The hydrodynamic forces originating at 'seabed' of the assembly chamber can be used to tightly aggregate inorganic and biological entities at packing densities that resemble those of native tissues. Additionally, following a layer-by-layer assembly procedure, centimeter scaled osteoinductive three-dimensional and cellularized constructs have been fabricated. We showed that the intimate connection between biological building blocks is essential in engineering living system able of localized mineral deposition. Our results demonstrate, for the first time, the possibility to obtain three-dimensional cellularized and acellularized anisotropic constructs using Faraday waves.

8.
Clin Orthop Relat Res ; 481(10): 2044-2060, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37439643

RESUMEN

BACKGROUND: Staphylococcus aureus is the leading pathogen in fracture-related infection. Previous in vitro experiments, in vivo testing in wax moth larvae, and genomic analysis of clinical S. aureu s isolates from fracture-related infection identified low-virulence (Lo-SA5464) and high-virulence (Hi-SA5458) strains. These findings correlated with acute fracture-related infection induced by Hi-SA5458, whereas Lo-SA5464 caused a chronic fracture-related infection in its human host. However, it remains unclear whether and to what extent the causative pathogen is attributable to these disparities in fracture-related infections. QUESTION/PURPOSE: Are there differences in the course of infection when comparing these two different clinical isolates in a murine fracture-related infection model, as measured by (1) clinical observations of weight loss, (2) quantitative bacteriology, (3) immune response, and (4) radiographic and histopathologic morphology? METHODS: Twenty-five (including one replacement animal) female (no sex-specific influences expected), skeletally mature C57Bl/6N inbred mice between 20 and 28 weeks old underwent femoral osteotomy stabilized by titanium locking plates. Fracture-related infection was established by inoculation of high-virulence S. aureus EDCC 5458 (Hi-SA5458) or low-virulence S. aureus EDCC 5464 (Lo-SA5464) in the fracture gap. Each of these groups consisted of 12 randomly assigned animals. Mice were euthanized 4 and 14 days postsurgery, resulting in six animals per group and timepoint. The severity and progression of infection were assessed in terms of clinical observation of weight loss, quantitative bacteriology, quantitative serum cytokine levels, qualitative analysis of postmortem radiographs, and semiquantitative histopathologic evaluation. RESULTS: For clinical observations of weight change, no differences were seen at Day 4 between Hi-SA5458- and Lo-SA5464-infected animals (mean -0.6 ± 0.1 grams versus -0.8 ± 0.2 grams, mean difference -0.2 grams [95% CI -0.8 to 0.5 grams]; p =0.43), while at 14 days, the Hi-SA5458 group lost more weight than the Lo-SA5464 group (mean -1.55 ± 0.2 grams versus -0.8 ± 0.3 grams; mean difference 0.7 grams [95% CI 0.2 to 1.3 grams]; p = 0.02). Quantitative bacteriological results 4 days postoperatively revealed a higher bacterial load in soft tissue samples in Hi-SA5458-infected animals than in the Lo-SA5464-infected cohort (median 6.8 x 10 7 colony-forming units [CFU]/g, range 2.2 x 10 7 to 2.1 x 10 9 CFU/g versus median 6.0 x 10 6 CFU/g, range 1.8 x 10 5 to 1.3 x 10 8 CFU/g; difference of medians 6.2 x 10 7 CFU/g; p = 0.03). At both timepoints, mice infected with the Hi-SA5458 strain also displayed higher proportions of bacterial dissemination into organs than Lo-SA5464-infected animals (67% [24 of 36 organs] versus 14% [five of 36 organs]; OR 12.0 [95% CI 3.7 to 36]; p < 0.001). This was accompanied by a pronounced proinflammatory response on Day 14, indicated by increased serum cytokine levels of interleukin-1ß (mean 9.0 ± 2.2 pg/mL versus 5.3 ± 1.5 pg/mL; mean difference 3.6 pg/mL [95% CI 2.0 to 5.2 pg/mL]; p < 0.001), IL-6 (mean 458.6 ± 370.7 pg/mL versus 201.0 ±89.6 pg/mL; mean difference 257.6 pg/mL [95% CI 68.7 to 446.5 pg/mL]; p = 0.006), IL-10 (mean 15.9 ± 3.5 pg/mL versus 9.9 ± 1.0 pg/mL; mean difference 6.0 pg/mL [95% CI 3.2 to 8.7 pg/mL]; p < 0.001), and interferon-γ (mean 2.7 ± 1.9 pg/mL versus 0.8 ± 0.3 pg/mL; mean difference 1.8 pg/mL [95% CI 0.5 to 3.1 pg/mL]; p = 0.002) in Hi-SA5458-infected compared with Lo-SA5464-infected animals. The semiquantitative histopathologic assessment on Day 4 revealed higher grades of granulocyte infiltration in Hi-SA5458-infected animals (mean grade 2.5 ± 1.0) than in Lo-SA5464-infected animals (mean grade 1.8 ± 1.4; mean difference 0.7 [95% CI 0.001 to 1.4]; p = 0.0498). On Day 14, bone healing at the fracture site was present to a higher extent in Lo-SA5464-infected animals than in Hi-SA5458-infected animals (mean grade 0.2 ± 0.4 versus 1.8 ± 1.2; mean difference -1.6 [95% CI -2.8 to -0.5]; p = 0.008). CONCLUSION: Similar to septic infection in a human host, infection with Hi-SA5458 in this murine model was characterized by a higher bacterial load, more-pronounced systemic dissemination, and stronger systemic and local inflammation. Thus, there is strong support for the idea that pathogenic virulence plays a crucial role in fracture-related infections. To confirm our observations, future studies should focus on characterizing S. aureus virulence at the genomic and transcriptomic levels in more clinical isolates and patients. Comparing knockout and wildtype strains in vitro and in vivo, including the S. aureus strains studied, could confirm our findings and identify the genomic features responsible for S. aureus virulence in fracture-related infections. CLINICAL RELEVANCE: For translational use, virulence profiles of S. aureus may be useful in guiding treatment decisions in the future. Once specific virulence targets are identified, one approach to fracture-related infections with high-virulence strains might be the development of antivirulence agents, particularly to treat or prevent septic dissemination. For fracture-related infections with low virulence, prolonged antimicrobial therapy or exchange of an indwelling implant might be beneficial owing to slower growth and persistence capacity.


Asunto(s)
Fracturas del Fémur , Osteomielitis , Infecciones Estafilocócicas , Animales , Femenino , Ratones , Citocinas , Modelos Animales de Enfermedad , Fracturas del Fémur/cirugía , Osteomielitis/microbiología , Infecciones Estafilocócicas/microbiología , Staphylococcus aureus/fisiología
9.
PLoS One ; 18(5): e0285770, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37172030

RESUMEN

Pneumonia, always a major malady, became the main public health and economic disaster of historical proportions with the COVID-19 pandemic. This study was based on a premise that pathology of lung metabolism in inflammation may have features invariant to the nature of the underlying cause. Amino acid uptake by the lungs was measured from plasma samples collected pre-terminally from a carotid artery and vena cava in mice with bleomycin-induced lung inflammation (N = 10) and compared to controls treated with saline instillation (N = 6). In the control group, the difference in concentrations between the arterial and venous blood of the 19 amino acids measured reached the level of statistical significance only for arginine (-10.7%, p = 0.0372) and phenylalanine (+5.5%, p = 0.0266). In the bleomycin group, 11 amino acids had significantly lower concentrations in the arterial blood. Arginine concentration was decreased by 21.1% (p<0.0001) and only that of citrulline was significantly increased (by 20.1%, p = 0.0002). Global Arginine Bioavailability Ratio was decreased in arterial blood by 19.5% (p = 0.0305) in the saline group and by 30.4% (p<0.0001) in the bleomycin group. Production of nitric oxide (NO) and citrulline from arginine by the inducible nitric oxide synthase (iNOS) is greatly increased in the immune system's response to lung injury. Deprived of arginine, the endothelial cells downstream may fail to provide enough NO to prevent the activation of thrombocytes. Thrombotic-related vascular dysfunction is a defining characteristic of pneumonia, including COVID-19. This experiment lends further support to arginine replacement as adjuvant therapy in pneumonia.


Asunto(s)
COVID-19 , Neumonía , Ratones , Humanos , Animales , Arginina/metabolismo , Bleomicina/toxicidad , Células Endoteliales/metabolismo , Citrulina/metabolismo , Pandemias , COVID-19/patología , Pulmón/patología , Neumonía/patología , Óxido Nítrico Sintasa de Tipo II/metabolismo , Óxido Nítrico/metabolismo
10.
Int Orthop ; 47(4): 1079-1087, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36749374

RESUMEN

BACKGROUND/PURPOSE: Pubic ramus fractures account for the most common types of pelvic fractures. The standard surgical approach for superior pubic ramus fractures (SPRF) is a minimally invasive percutaneous screw fixation. However, percutaneous closed reduction and internal fixation of anterior pelvic ring injuries have high failure rates of up to 15%. The aim of this biomechanical study was to evaluate the stability of SPRF following stabilization with retrograde placed cannulated compression headless screw (CCHS) versus conventional fully and partially threaded screws in an artificial pelvic bone model. METHODS: SPRF type II as described by Nakatani et al. was created by means of osteotomies in eighteen anatomical composite hemi-pelvises. Specimens were stratified into three groups of six specimens each (n = 6) for fixation with either a 7.3 mm partially threaded cannulated screw (group RST), a 7.3 mm fully threaded cannulated screw (group RSV), or a 7.5 mm partially threaded cannulated CCHS (group CCS). Each hemi-pelvic specimen was tested in an inverted upright standing position under progressively increasing cyclic axial loading. The peak load, starting at 200 N, was monotonically increased at a rate of 0.1 N/cycle until 10 mm actuator displacement. RESULTS: Total and torsional displacement were associated with higher values for RST versus CCS and RSV, with significant differences between RST and CCS for both these parameters (p ≤ 0.033). The differences between RST and RSV were significant for total displacement (p = 0.020), and a trend toward significance for torsional displacement (p = 0.061) was observed. For both failure criteria 2 mm total displacement and 5° torsional displacement, CCS was associated with significantly higher number of cycles compared to RST (p ≤ 0.040). CONCLUSION: CCHS fixation presented predominantly superior stability to the standard surgical treatment and could therefore be a possible alternative implant for retrograde SPRF screw fixation, whereas partially threaded screws in group RST were associated with inferior biomechanical stability.


Asunto(s)
Fracturas Óseas , Huesos Pélvicos , Humanos , Tornillos Óseos , Fracturas Óseas/cirugía , Fijación Interna de Fracturas , Hueso Púbico , Huesos Pélvicos/cirugía , Huesos Pélvicos/lesiones , Fenómenos Biomecánicos
11.
Sci Rep ; 12(1): 20076, 2022 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-36418373

RESUMEN

Orthopaedic screws insertion can be trivialised as a simple procedure, however it is frequently performed poorly. Limited work exists defining how well surgeons insert screws or whether augmented screwdrivers can aid surgeons to reduce stripping rates and optimise tightness. We aimed to establish the performance of surgeons inserting screws and whether this be improved with screwdriver augmentation. 302 orthopaedic surgeons tightened 10 non-locking screws to what they determined to be optimum tightness into artificial bone sheets. The confidence in the screw purchase was given (1-10). A further 10 screws were tightened, using an augmented screwdriver that indicated when a predetermined optimum tightness was reached. The tightness for unstripped insertions under normal conditions and with the augmented screwdriver were 81% (95% CI 79-82%)(n = 1275) and 70% (95% CI 69-72%)(n = 2577) (p < 0.001). The stripping rates were 58% (95% CI 54-61%) and 15% (95% CI 12-17%) respectively (p < 0.001). The confidences when using the normal and augmented screwdrivers respectively were 7.2 and 7.1 in unstripped insertions and 6.2 and 6.5 in stripped insertions. Performance improved with an augmented screwdriver, both in reduced stripping rates and greater accuracy in detecting stripping. Augmenting screwdrivers to indicate optimum tightness offer potentially enormous clinical benefits by improving screw fixation.


Asunto(s)
Cirujanos Ortopédicos , Ortopedia , Cirujanos , Humanos , Fijadores Internos , Tornillos Óseos
12.
JOR Spine ; 5(3): e1215, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36203866

RESUMEN

Background: During the intervertebral disc (IVD) degeneration process, initial degenerative events occur at the extracellular matrix level, with the appearance of neoepitope peptides formed by the cleavage of aggrecan and collagen. This study aims to elucidate the spatial and temporal alterations of aggrecan and collagen neoepitope level during IVD degeneration. Methods: Bovine caudal IVDs were cultured under four different conditions to mimic different degenerative situations. Samples cultured after 1- or 8-days were collected for analysis. Human IVD samples were obtained from patients diagnosed with lumbar disc herniation (LDH) or adolescent idiopathic scoliosis (AIS). After immunohistochemical (IHC) staining of Aggrecanase Cleaved C-terminus Aggrecan Neoepitope (NB100), MMP Cleaved C-terminus Aggrecan Neoepitope (MMPCC), Collagen Type 1α1 1/4 fragment (C1α1) and Collagenase Cleaved Type I and II Collagen Neoepitope (C1,2C), staining optical density (OD)/area in extracellular matrix (OECM) and pericellular zone (OPCZ) were analyzed. Conditioned media of the bovine IVD was collected to measure protein level of inflammatory cytokines and C1,2C. Results: For the bovine IVD sections, the aggrecan MMPCC neoepitope was accumulated in nucleus pulposus (NP) and cartilage endplate (EP) regions following mechanical overload in the one strike model after long-term culture; as for the TNF-α induced degeneration, the OECM and OPCZ of collagen C1,2C neoepitope was significantly increased in the outer AF region after long-term culture; moreover, the C1,2C was only detected in conditioned medium from TNF-α injection + Degenerative loading group after 8 days of culture. LDH patients showed higher MMPCC OECM in NP and higher C1,2C OECM in AF region compared with AIS patients. Conclusions: In summary, aggrecan and collagen neoepitope profiles showed degeneration induction trigger- and region-specific differences in the IVD organ culture models. Different IVD degeneration types are correlated with specific neoepitope expression profiles. These neoepitopes may be helpful as biomarkers of ECM degradation in early IVD degeneration and indicators of different degeneration phenotypes.

13.
Nat Rev Dis Primers ; 8(1): 67, 2022 10 20.
Artículo en Inglés | MEDLINE | ID: mdl-36266296

RESUMEN

Musculoskeletal trauma leading to broken and damaged bones and soft tissues can be a life-threating event. Modern orthopaedic trauma surgery, combined with innovation in medical devices, allows many severe injuries to be rapidly repaired and to eventually heal. Unfortunately, one of the persisting complications is fracture-related infection (FRI). In these cases, pathogenic bacteria enter the wound and divert the host responses from a bone-healing course to an inflammatory and antibacterial course that can prevent the bone from healing. FRI can lead to permanent disability, or long courses of therapy lasting from months to years. In the past 5 years, international consensus on a definition of these infections has focused greater attention on FRI, and new guidelines are available for prevention, diagnosis and treatment. Further improvements in understanding the role of perioperative antibiotic prophylaxis and the optimal treatment approach would be transformative for the field. Basic science and engineering innovations will be required to reduce infection rates, with interventions such as more efficient delivery of antibiotics, new antimicrobials, and optimizing host defences among the most likely to improve the care of patients with FRI.


Asunto(s)
Fracturas Óseas , Infección de la Herida Quirúrgica , Humanos , Infección de la Herida Quirúrgica/tratamiento farmacológico , Infección de la Herida Quirúrgica/microbiología , Infección de la Herida Quirúrgica/prevención & control , Fracturas Óseas/complicaciones , Antibacterianos/uso terapéutico , Consenso
14.
Arthritis Res Ther ; 24(1): 105, 2022 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-35545776

RESUMEN

Osteoarthritis (OA) is one of the most common musculoskeletal degenerative diseases and contributes to heavy socioeconomic burden. Current pharmacological and conventional non-pharmacological therapies aim at relieving the symptoms like pain and disability rather than modifying the underlying disease. Surgical treatment and ultimately joint replacement arthroplasty are indicated in advanced stages of OA. Since the underlying mechanisms of OA onset and progression have not been fully elucidated yet, the development of novel therapeutics to prevent, halt, or reverse the disease is laborious. Recently, small molecules of herbal origin have been reported to show potent anti-inflammatory, anti-catabolic, and anabolic effects, implying their potential for treatment of OA. Herein, the molecular mechanisms of these small molecules, their effect on physiological or pathological signaling pathways, the advancement of the extraction methods, and their potential clinical translation based on in vitro and in vivo evidence are comprehensively reviewed.


Asunto(s)
Artroplastia de Reemplazo , Osteoartritis , Antiinflamatorios/uso terapéutico , Humanos , Osteoartritis/tratamiento farmacológico , Osteoartritis/metabolismo , Dolor/tratamiento farmacológico , Transducción de Señal
15.
Sci Rep ; 12(1): 797, 2022 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-35039503

RESUMEN

A series of gallium arsenide bismide device layers covering a range of growth conditions are thoroughly probed by low-temperature, power-dependent photoluminescence measurements. The photoluminescence data is modelled using a localised state profile consisting of two Gaussians. Good agreement with the raw data is achieved for all layers whilst fixing the standard deviation values of the two Gaussians and constraining the band gap using X-ray diffraction data. The effects of growth temperature and bismuth beam equivalent pressure on the localised state distributions, and other model variables, are both shown to be linked to emission linewidth and device properties. It is concluded that bismuth rich surface conditions are preferable during growth in order to produce the narrowest emission linewidths with this material. These results also show how the growth mode of a gallium arsenide bismide layer can be inferred ex-situ from low-temperature photoluminescence measurements.

16.
Eur J Trauma Emerg Surg ; 48(6): 4523-4529, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32761437

RESUMEN

PURPOSE: Osteosynthesis of proximal humeral fractures remains challenging with high reported failure rates. Understanding the fracture type is mandatory in surgical treatment to achieve an optimal anatomical reduction. Therefore, a better classification ability resulting in improved understanding of the fracture pattern is important for preoperative planning. The purpose was to investigate the feasibility and added value of advanced visualization of segmented 3D computed tomography (CT) images in fracture classification. METHODS: Seventeen patients treated with either plate-screw-osteosynthesis or shoulder hemi-prosthesis between 2015 and 2019 were included. All preoperative CT scans were segmented to indicate every fracture fragment in a different color. Classification ability was tested in 21 orthopaedic residents and 12 shoulder surgeons. Both groups were asked to classify fractures using three different modalities (standard CT scan, 3D reconstruction model, and 3D segmented model) into three different classification systems (Neer, AO/OTA and LEGO). RESULTS: All participants were able to classify the fractures more accurately into all three classification systems after evaluating the segmented three-dimensional (3D) models compared to both 2D slice-wise evaluation and 3D reconstruction model. This finding was significant (p < 0.005) with an average success rate of 94%. The participants experienced significantly more difficulties classifying fractures according to the LEGO system than the other two classifications. CONCLUSION: Segmentation of CT scans added value to the proximal humeral fracture classification, since orthopaedic surgeons were able to classify fractures significantly better into the AO/OTA, Neer, and LEGO classification systems compared to both standard 2D slice-wise evaluation and 3D reconstruction model.


Asunto(s)
Cirujanos Ortopédicos , Ortopedia , Fracturas del Hombro , Humanos , Estudios de Factibilidad , Imagenología Tridimensional/métodos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía , Tomografía Computarizada por Rayos X/métodos
17.
J Shoulder Elbow Surg ; 31(1): 192-200, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34298147

RESUMEN

BACKGROUND: Optimal treatment options for proximal humerus fractures (PHFs) are still debated because of persisting high fixation failure rates experienced with locking plates. Optimization of the implants and development of patient-specific designs may help improve the primary fixation stability of PHFs and reduce the rate of mechanical failures. Optimizing the screw orientations in locking plates has shown promising results; however, the potential benefit of subject-specific designs has not been explored yet. The purpose of this study was to evaluate by means of finite element (FE) analyses whether subject-specific optimization of the screw orientations in a fixed-angle locking plate can reduce the predicted cutout failure risk in unstable 3-part fractures. METHODS: FE models of 19 low-density proximal humeri were generated from high-resolution computed tomographic images using a previously developed and validated computational osteosynthesis framework. The specimens were virtually osteotomized to simulate unstable malreduced 3-part fractures and fixed with the PHILOS plates using 6 proximal locking screws. The average principal compressive strain in cylindrical bone regions around the screw tips-a biomechanically validated surrogate for the risk of cyclic screw cutout failure-was defined as the main outcome measure. The angles of the 6 proximal locking screws were optimized via parametric analysis for each humerus individually, resulting in subject-specific screw orientations (SSO). The average peri-implant strains of the SSO were statistically compared with the previously reported cohort-specific (CSO) and original PHILOS screw orientations (PSO) for females vs. males. RESULTS: The optimized SSO significantly reduced the peri-screw bone strain vs. CSO (6.8% ± 4.0%, P = .006) and PSO (25.24% ± 7.93%, P < .001), indicating lower cutout risk for subject-specific configurations. The benefits of SSO vs. PSO were significantly higher for women than men. CONCLUSION: The findings of this study suggest that subject-specific optimization of the locking screw orientations could lead to lower cutout risk and improved PHF fixation. These computer simulation results require biomechanical and clinical corroboration. Further studies are needed to evaluate whether the potential benefit in stability could justify the increased efforts related to implementation of individualized implants. Nevertheless, computational exploration of the biomechanical factors influencing the outcome of fracture fixations could help better understand the fixation failures and reduce their incidence.


Asunto(s)
Fracturas del Hombro , Fenómenos Biomecánicos , Placas Óseas , Simulación por Computador , Femenino , Fijación Interna de Fracturas , Humanos , Húmero , Masculino , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía
18.
Bioact Mater ; 9: 281-298, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34820571

RESUMEN

The osteogenic microenvironment of bone-repairing materials plays a key role in accelerating bone regeneration but remains incompletely defined, which significantly limits the application of such bioactive materials. Here, the transcriptional landscapes of different osteogenic microenvironments, including three-dimensional (3D) hydroxyapatite (HA) scaffolds and osteogenic medium (OM), for mesenchymal stromal cells (MSCs) in vitro were mapped at single-cell resolution. Our findings suggested that an osteogenic process reminiscent of endochondral ossification occurred in HA scaffolds through sequential activation of osteogenic-related signaling pathways, along with inflammation and angiogenesis, but inhibition of adipogenesis and fibrosis. Moreover, we revealed the mechanism during OM-mediated osteogenesis involves the ZBTB16 and WNT signaling pathways. Heterogeneity of MSCs was also demonstrated. In vitro ossification of LRRC75A+ MSCs was shown to have better utilization of WNT-related ossification process, and PCDH10+ MSCs with superiority in hydroxyapatite-related osteogenic process. These findings provided further understanding of the cellular activity modulated by OM conditions and HA scaffolds, providing new insights for the improvement of osteogenic biomaterials. This atlas provides a blueprint for research on MSC heterogeneity and the osteogenic microenvironment of HA scaffolds and a database reference for the application of bioactive materials for bone regeneration.

19.
Mediators Inflamm ; 2021: 8817421, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34924815

RESUMEN

Short-chain fatty acids (SCFAs) produced by the gut microbiota have previously been demonstrated to play a role in numerous chronic inflammatory diseases and to be key mediators in the gut-bone signaling axis. However, the role of SCFAs in bone fracture healing and its impact on systemic inflammation during the regeneration process has not been extensively investigated yet. The aim of this study was to first determine the effects of the SCFA butyrate on key cells involved in fracture healing in vitro, namely, osteoclasts and mesenchymal stromal cells (MSCs), and second, to assess if butyrate supplementation or antibiotic therapy impacts bone healing, systemic immune status, and inflammation levels in a murine osteotomy model. Butyrate significantly reduced osteoclast formation and resorption activity in a dose-dependent manner and displayed a trend for increased calcium deposits in MSC cultures. Numerous genes associated with osteoclast differentiation were differentially expressed in osteoclast precursor cells upon butyrate exposure. In vivo, antibiotic-treated mice showed reduced SCFA levels in the cecum, as well as a distinct gut microbiome composition. Furthermore, circulating proinflammatory TNFα, IL-17a, and IL-17f levels, and bone preserving osteoprotegerin (OPG), were increased in antibiotic-treated mice compared to controls. Antibiotic-treated mice also displayed a trend towards delayed bone healing as revealed by reduced mineral apposition at the defect site and higher circulating levels of the bone turnover marker PINP. Butyrate supplementation resulted in a lower abundance of monocyte/macrophages in the bone marrow, as well as reduced circulating proinflammatory IL-6 levels compared to antibiotic- and control-treated mice. In conclusion, this study supports our hypothesis that SCFAs, in particular butyrate, are important contributors to successful bone healing by modulating key cells involved in fracture healing as well as systemic inflammation and immune responses.


Asunto(s)
Antibacterianos/farmacología , Butiratos/farmacología , Curación de Fractura/efectos de los fármacos , Inflamación/etiología , Osteoclastos/efectos de los fármacos , Animales , Diferenciación Celular/efectos de los fármacos , Células Cultivadas , Citocinas/análisis , Ácidos Grasos Volátiles/farmacología , Curación de Fractura/fisiología , Microbioma Gastrointestinal/efectos de los fármacos , Humanos , Mediadores de Inflamación/análisis , Levofloxacino/farmacología , Masculino , Ratones , Ratones Endogámicos C57BL , Osteoclastos/citología , Osteotomía , Rifampin/farmacología
20.
Microbiol Spectr ; 9(3): e0173621, 2021 12 22.
Artículo en Inglés | MEDLINE | ID: mdl-34908439

RESUMEN

Although several studies have shown promising clinical outcomes of phage therapy in patients with orthopedic device-related infections, questions remain regarding the optimal application protocol, systemic effects, and the impact of the immune response. This study provides a proof-of-concept of phage therapy in a clinically relevant rabbit model of fracture-related infection (FRI) caused by Staphylococcus aureus. In a prevention setting, phage in saline (without any biomaterial-based carrier) was highly effective in the prevention of FRI, compared to systemic antibiotic prophylaxis alone. In the subsequent study involving treatment of established infection, daily administration of phage in saline through a subcutaneous access tube was compared to a single intraoperative application of a phage-loaded hydrogel and a control group receiving antibiotics only. In this setting, although a possible trend of bacterial load reduction on the implant was observed with the phage-loaded hydrogel, no superior effect of phage therapy was found compared to antibiotic treatment alone. The application of phage in saline through a subcutaneous access tube was, however, complicated by superinfection and the development of neutralizing antibodies. The latter was not found in the animals that received the phage-loaded hydrogel, which may indicate that encapsulation of phages into a carrier such as a hydrogel limits their exposure to the adaptive immune system. These studies show phage therapy can be useful in targeting orthopedic device-related infection, however, further research and improvements of these application methods are required for this complex clinical setting. IMPORTANCE Because of the growing spread of antimicrobial resistance, the use of alternative prevention and treatment strategies is gaining interest. Although the therapeutic potential of bacteriophages has been demonstrated in a number of case reports and series over the past decade, many unanswered questions remain regarding the optimal application protocol. Furthermore, a major concern during phage therapy is the induction of phage neutralizing antibodies. This study aimed at providing a proof-of-concept of phage therapy in a clinically relevant rabbit model of fracture-related infection caused by Staphylococcus aureus. Phage therapy was applied as prophylaxis in a first phase, and as treatment of an established infection in a second phase. The development of phage neutralizing antibodies was evaluated in the treatment study. This study demonstrates that phage therapy can be useful in targeting orthopedic device-related infection, especially as prophylaxis; however, further research and improvements of these application methods are required.


Asunto(s)
Antibacterianos/uso terapéutico , Fracturas Óseas/microbiología , Terapia de Fagos/métodos , Infecciones Relacionadas con Prótesis/terapia , Infecciones Estafilocócicas/terapia , Fagos de Staphylococcus/crecimiento & desarrollo , Animales , Anticuerpos Neutralizantes/inmunología , Anticuerpos Antivirales/inmunología , Modelos Animales de Enfermedad , Evaluación Preclínica de Medicamentos , Farmacorresistencia Bacteriana/genética , Femenino , Fracturas Óseas/patología , Hidrogeles/uso terapéutico , Prueba de Estudio Conceptual , Infecciones Relacionadas con Prótesis/microbiología , Conejos , Infecciones Estafilocócicas/prevención & control , Fagos de Staphylococcus/inmunología , Staphylococcus aureus/virología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...