Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39297837

RESUMEN

BACKGROUND: Termination of ventricular tachycardia (VT) by a pacing stimulus that does not generate a QRS complex (termination without global propagation [TWGP]) can be a marker for a critical re-entry circuit isthmus. However, the electrophysiologic and anatomic features of these sites and their relation to VT substrate defined by 3-dimensional electroanatomical maps (3D-EAM) remain unknown. OBJECTIVES: This retrospective study aimed to characterize TWGP sites and their relation to VT substrate identified by 3D-EAM. METHODS: A total of 632 consecutive cases of catheter ablation for scar-related VT at 2 University medical centers were reviewed to identify TWGP. RESULTS: TWGP was observed 12 times at 11 different sites in 10 patients (5 ischemic cardiomyopathy). The TWGP stimulus fell immediately before or synchronous with the QRS in all cases, and evidence of local capture despite absence of a QRS complex was observed 6 times. In 5 sites, pacing after VT termination produced a QRS different than the VT. Four sites were in dense scar areas (<0.1 mV), and 6 in abnormal low voltage zone (0.1-1.5 mV). Additional mapping or ablation that abolished VT were consistent with the TWGP site being in a VT isthmus. A substrate marker for VT of late potentials, evoked delayed potentials, or slow conduction was present at 6 of 11 TWGP sites. CONCLUSIONS: TWGP may be a marker for detecting a re-entry circuit isthmus that has escaped detection based on electrogram or pace mapping-based substrate mapping.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39243256

RESUMEN

BACKGROUND: Patients with rare, pathogenic cardiomyopathy (CM) and arrhythmia variants can present with atrial fibrillation (AF). The efficacy of AF ablation in these patients is unknown. OBJECTIVE: This study tested the hypotheses that: 1) patients with a pathogenic variant in any CM or arrhythmia gene have increased recurrence following AF ablation; and 2) patients with a pathogenic variant associated with a specific gene group (arrhythmogenic left ventricular CM [ALVC], arrhythmogenic right ventricular CM, dilated CM, hypertrophic CM, or a channelopathy) have increased recurrence. METHODS: We performed a prospective, observational, cohort study of patients who underwent AF catheter ablation and whole exome sequencing. The primary outcome measure was ≥30 seconds of any atrial tachyarrhythmia that occurred after a 90-day blanking period. RESULTS: Among 1,366 participants, 109 (8.0%) had a pathogenic or likely pathogenic (P/LP) variant in a CM or arrhythmia gene. In multivariable analysis, the presence of a P/LP variant in any gene was not significantly associated with recurrence (HR 1.15; 95% CI 0.84-1.60; P = 0.53). P/LP variants in the ALVC gene group, predominantly LMNA, were associated with increased recurrence (n = 10; HR 3.75; 95% CI 1.84-7.63; P < 0.001), compared with those in the arrhythmogenic right ventricular CM, dilated CM, hypertrophic CM, and channelopathy gene groups. Participants with P/LP TTN variants (n = 46) had no difference in recurrence compared with genotype-negative-controls (HR 0.93; 95% CI 0.54-1.59; P = 0.78). CONCLUSIONS: Our results support the use of AF ablation for most patients with rare pathogenic CM or arrhythmia variants, including TTN. However, patients with ALVC variants, such as LMNA, may be at a significantly higher risk for arrhythmia recurrence.

3.
Artículo en Inglés | MEDLINE | ID: mdl-39049489

RESUMEN

INTRODUCTION: Catheter-based radiofrequency (RF) ablation is generally regarded as the standard approach for patients with ventricular tachycardia (VT) refractory to antiarrhythmic drug therapy and may be considered as a first-line approach when there is a preference to avoid these agents. Patients with a history of cardiac surgery may have VT substrate inaccessible to catheter ablation due to intervening prosthetic materials or scar. METHODS AND RESULTS: This article describes a 55-year-old patient with a history of surgically repaired subvalvular aortic stenosis and subsequent valve-sparing root replacement who presented with sustained VT. After RF ablation failed due to VT substrate "guarded" by graft material, retrograde coronary venous ethanol ablation (RCVEA) was employed to successfully treat the clinical VT. CONCLUSION: RCVEA ablation can be useful for treating VT when conventional ablation is limited by inaccessible substrate due to prior cardiac surgery.

4.
Heart Rhythm ; 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38945504

RESUMEN

BACKGROUND: Many genetic nonischemic dilated cardiomyopathies (NICMs) cause ventricular tachycardias (VTs) originating from scar substrate identified as areas of low electrogram voltage. Substrate locations vary, and the causes of scar are not well defined. OBJECTIVE: This study evaluated VT substrate locations in genetic NICM patients undergoing VT ablation to evaluate spatial relationships between specific variants and substrate locations. METHODS: In this retrospective case series analysis, 32 patients (aged 55 ± 16 years; 94% male; left ventricular ejection fraction, 34% ± 13%) with genetic NICM referred for VT ablation between October 2018 and November 2022 at a single medical center were evaluated. Scar locations were defined as areas of low unipolar or bipolar voltage. RESULTS: Of the 32 patients evaluated, mutations in TTN (n = 11), LMNA (n = 6), PKP2 (n = 5), MYBPC3 (n = 3), DSP (n = 2), TTR (n = 1), FLNC (n = 1), AGL (n = 1), DES (n = 1), and DSG2 (n = 1) were observed. Substrates associated with mutations in TTN were observed only in basal subregions, predominantly anterior (100%) and septal (50%) regions. LMNA mutations were associated with fibrosis in mid inferolateral (60%) and apical inferolateral (60%) regions. Substrate location for individuals with PKP2 mutations was solely observed in the right ventricle, predominantly basal inferolateral regions. CONCLUSION: Understanding spatial relationships between genetic variants causing NICM and VT substrate locations can help lead to generalizable regions in patients with genetically related NICM presenting in VT, which can be investigated during ablation procedures.

5.
Circ Arrhythm Electrophysiol ; 17(6): e012635, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38804141

RESUMEN

BACKGROUND: Irrigated radiofrequency ablation with half-normal saline can potentially increase lesion size but may increase the risk of steam pops with the risk of emboli or perforation. We hypothesized that pops would be preceded by intracardiac echocardiography (ICE) findings as well as a large impedance fall. METHODS: In 100 consecutive patients undergoing endocardial ventricular arrhythmia radiofrequency ablation with half-normal saline, we attempted to observe the ablation site with ICE. Radiofrequency ablation power was titrated to a 15 to 20 Ohm impedance fall and could be adjusted for tissue whitening and increasing bubble formation on ICE. Steam pops were defined as audible or a sudden explosion of microbubbles on ICE. RESULTS: Of 2190 ablation applications in 100 patients (82% cardiomyopathy, 50% sustained ventricular tachycardia), pops occurred during 43 (2.0%) applications. Sites with pops had greater impedance decreases of 18 [14, 21]% versus 13 [10, 17]% (P<0.001). ICE visualized 1308 (59.7%) radiofrequency sites, and fewer pops occurred when ICE visualized the radiofrequency ablation site (1.4%) compared with without ICE visualization (2.8%; P=0.016). Of the 18 ICE-visible pops, 7 (39%) were silent but recognized as an explosion of bubbles on ICE. With ICE, 89% of pops were preceded by either tissue whitening or a sudden increase in bubbles. In a multivariable model, tissue whitening and a sudden increase in bubbles were associated with steam pops (odds ratio, 7.186; P=0.004, and odds ratio, 29.93; P<0.001, respectively), independent of impedance fall and power. There were no pericardial effusions or embolic events with steam pops. CONCLUSIONS: Steam pops occurred in 2% of half-normal saline radiofrequency applications titrated to an impedance fall and are likely under-recognized without ICE. On ICE, steam pops are usually preceded by tissue whitening or a sudden increase in bubble formation, which can potentially be used to adjust radiofrequency application to help reduce pops.


Asunto(s)
Ablación por Catéter , Ecocardiografía , Solución Salina , Vapor , Taquicardia Ventricular , Irrigación Terapéutica , Humanos , Masculino , Femenino , Solución Salina/administración & dosificación , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/diagnóstico por imagen , Anciano , Embolia Aérea/prevención & control , Embolia Aérea/etiología , Embolia Aérea/diagnóstico por imagen , Resultado del Tratamiento , Factores de Riesgo , Valor Predictivo de las Pruebas , Impedancia Eléctrica
7.
Heart Rhythm ; 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38762820

RESUMEN

BACKGROUND: Implantable cardioverter-defibrillators last longer, and interest in reliable leads with targeted lead placement is growing. The OmniaSecure™ defibrillation lead is a novel small-diameter, catheter-delivered lead designed for targeted placement, based on the established SelectSecure SureScan MRI Model 3830 lumenless pacing lead platform. OBJECTIVE: This trial assessed safety and efficacy of the OmniaSecure defibrillation lead. METHODS: The worldwide LEADR pivotal clinical trial enrolled patients indicated for de novo implantation of a primary or secondary prevention implantable cardioverter-defibrillator/cardiac resynchronization therapy defibrillator, all of whom received the study lead. The primary efficacy end point was successful defibrillation at implantation per protocol. The primary safety end point was freedom from study lead-related major complications at 6 months. The primary efficacy and safety objectives were met if the lower bound of the 2-sided 95% credible interval was >88% and >90%, respectively. RESULTS: In total, 643 patients successfully received the study lead, and 505 patients have completed 12-month follow-up. The lead was placed in the desired right ventricular location in 99.5% of patients. Defibrillation testing at implantation was completed in 119 patients, with success in 97.5%. The Kaplan-Meier estimated freedom from study lead-related major complications was 97.1% at 6 and 12 months. The trial exceeded the primary efficacy and safety objective thresholds. There were zero study lead fractures and electrical performance was stable throughout the mean follow-up of 12.7 ± 4.8 months (mean ± SD). CONCLUSION: The OmniaSecure lead exceeded prespecified primary end point performance goals for safety and efficacy, demonstrating high defibrillation success and a low occurrence of lead-related major complications with zero lead fractures.

9.
J Am Heart Assoc ; 13(6): e031029, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38471835

RESUMEN

BACKGROUND: Recurrence after atrial fibrillation (AF) ablation remains common. We evaluated the association between recurrence and levels of biomarkers of cardiac remodeling, and their ability to improve recurrence prediction when added to a clinical prediction model. METHODS AND RESULTS: Blood samples collected before de novo catheter ablation were analyzed. Levels of bone morphogenetic protein-10, angiopoietin-2, fibroblast growth factor-23, insulin-like growth factor-binding protein-7, myosin-binding protein C3, growth differentiation factor-15, interleukin-6, N-terminal pro-brain natriuretic peptide, and high-sensitivity troponin T were measured. Recurrence was defined as ≥30 seconds of an atrial arrhythmia 3 to 12 months postablation. Multivariable logistic regression was performed using biomarker levels along with clinical covariates: APPLE score (Age >65 years, Persistent AF, imPaired eGFR [<60 ml/min/1.73m2], LA diameter ≥43 mm, EF <50%; which includes age, left atrial diameter, left ventricular ejection fraction, persistent atrial fibrillation, and estimated glomerular filtration rate), preablation rhythm, sex, height, body mass index, presence of an implanted continuous monitor, year of ablation, and additional linear ablation. A total of 1873 participants were included. A multivariable logistic regression showed an association between recurrence and levels of angiopoietin-2 (odds ratio, 1.08 [95% CI, 1.02-1.15], P=0.007) and interleukin-6 (odds ratio, 1.02 [95% CI, 1.003-1.03]; P=0.02). The area under the receiver operating characteristic curve of a model that only contained clinical predictors was 0.711. The addition of any of the 9 studied biomarkers to the predictive model did not result in a statistically significant improvement in the area under the receiver operating characteristic curve. CONCLUSIONS: Higher angiopoietin-2 and interleukin-6 levels were associated with recurrence after atrial fibrillation ablation in multivariable modeling. However, the addition of biomarkers to a clinical prediction model did not significantly improve recurrence prediction.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Ablación por Catéter , Humanos , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Angiopoyetina 2 , Interleucina-6 , Modelos Estadísticos , Volumen Sistólico , Remodelación Ventricular , Factores de Riesgo , Pronóstico , Recurrencia , Función Ventricular Izquierda , Biomarcadores , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
10.
J Cardiovasc Electrophysiol ; 35(5): 994-1004, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38501333

RESUMEN

INTRODUCTION: When ventricular tachycardia (VT) recurs after standard RF ablation (sRFA) some patients benefit from repeat sRFA, whereas others warrant advanced methods such as intramural needle ablation (INA). Our objectives are to assess the utility of repeat sRFA and to clarify the benefit of INA when repeat sRFA fails in patients with VT due to structural heart disease. METHODS: In consecutive patients who were prospectively enrolled in a study for INA for recurrent sustained monomorphic VT despite sRFA, repeat sRFA was considered first. INA was performed during the same procedure if repeat sRFA failed or no targets for sRFA were identified. RESULTS: Of 85 patients enrolled, acute success with repeat sRFA was achieved in 30 patients (35%), and during the 6-month follow-up, 87% (20/23) were free of VT hospitalization, 78% were free of any VT, and 7 were lost to follow-up. INA was performed in 55 patients (65%) after sRFA failed, or no endocardial targets were found abolished or modified inducible VT in 35/55 patients (64%). During follow-up, 72% (39/54) were free of VT hospitalization, 41% were free of any VT, and 1 was lost to follow-up. Overall, 59 out of 77 (77%) patients were free of hospitalization and 52% were free of any VT. Septal-origin VTs were more likely to need INA, whereas RV and papillary muscle VTs were less likely to require INA. CONCLUSIONS: Repeat sRFA was beneficial in 23% (18/77) of patients with recurrent sustained VT who were referred for INA. The availability of INA increased favorable outcomes to 52%.


Asunto(s)
Ablación por Catéter , Cicatriz , Recurrencia , Reoperación , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Masculino , Femenino , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Ablación por Catéter/efectos adversos , Cicatriz/fisiopatología , Cicatriz/diagnóstico , Cicatriz/cirugía , Cicatriz/etiología , Factores de Tiempo , Potenciales de Acción , Agujas , Frecuencia Cardíaca , Factores de Riesgo , Resultado del Tratamiento
11.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38367008

RESUMEN

AIMS: Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. METHODS AND RESULTS: Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15â€…Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. CONCLUSION: Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.


Asunto(s)
Ablación por Catéter , Ablación por Radiofrecuencia , Taquicardia Ventricular , Masculino , Humanos , Persona de Mediana Edad , Femenino , Solución Salina/efectos adversos , Vapor , Estudios Prospectivos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Taquicardia Ventricular/cirugía , Irrigación Terapéutica/efectos adversos
13.
JACC Clin Electrophysiol ; 10(2): 193-202, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38069975

RESUMEN

BACKGROUND: Risks of radiofrequency catheter ablation for ventricular arrhythmias include emboli and bleeding complications but data on antithrombotic regimens are limited and guidelines do not specify a systematic approach. OBJECTIVES: This study sought to assess embolic and bleeding complications in relation to pre-periprocedure and post-periprocedure antithrombotic regimens. METHODS: Prospective assessment for complications was performed for 663 endocardial radiofrequency catheter ablation procedures in 616 consecutive patients (median age 64 years [Q1-Q3: 54-73 years], 70.3% men, 71.6% with cardiomyopathy, 44.5% with sustained ventricular tachycardia). RESULTS: There were 2 strokes (0.3%; 95% CI: 0.0%-0.8%), 1 transient ischemic attack (0.15%), and 2 pulmonary emboli (0.3%). There were 39 bleeding complications (5.9%) including 11 pericardial effusions (1.7%), and 28 related to vascular access (4.2%). Consistent with the prevalence of coronary artery disease (47.5%), atrial fibrillation (30.0%), and prior stroke (10.6%), preprocedure, 464 patients (70.0%) were taking antithrombotic agents including 220 (33.2%) taking aspirin alone (ASA), and 163 (24.6%) taking warfarin or a direct acting oral anticoagulant (DOAC). Preprocedure non-ASA antiplatelet use (OR: 2.846; P = 0.011) and DOAC use (OR: 2.585; P = 0.032) were associated with risk of bleeding complications. Following ablation, 49.8% of patients were treated with ASA 325 mg/d and 30.3% received DOACs or warfarin. New DOAC or warfarin administration was initiated in only 6.6% of patients. Overall, 39.7% of patients continued the same preprocedure antithrombotic regimen. CONCLUSIONS: Stroke is a rare complication of radiofrequency catheter ablation for ventricular arrhythmia using ASA 325 mg/d as a minimal postprocedure regimen with more potent regimens for selected patients.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Masculino , Humanos , Persona de Mediana Edad , Femenino , Warfarina/efectos adversos , Anticoagulantes/efectos adversos , Hemorragia/etiología , Hemorragia/inducido químicamente , Fibrinolíticos , Estudios Prospectivos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/epidemiología , Fibrilación Atrial/cirugía , Aspirina/efectos adversos
14.
J Cardiovasc Electrophysiol ; 34(11): 2403-2405, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37787011

RESUMEN

INTRODUCTION: Intracardiac echocardiography (ICE) reveals mobile thrombus on implantable electronic device leads in some patients undergoing electrophysiologic procedures. METHODS: ICE was performed in a patient undergoing ventricular tachycardia (VT) ablation. RESULTS: ICE showed extensive mobile thrombi on the implantable cardioverter defibrillator lead. Radiofrequency catheter ablation of VT from perimitral scar was safely performed via a retrograde aortic approach. After the procedure, chronic anticoagulation was initiated. CT-angiography of the chest 2 months later showed no pulmonary emboli. CONCLUSIONS: The significance of these thrombi, as related to chronic pulmonary embolization, warrants further study.


Asunto(s)
Ablación por Catéter , Cardiopatías , Taquicardia Ventricular , Trombosis , Humanos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Viento , Cardiopatías/cirugía , Trombosis/diagnóstico por imagen , Trombosis/etiología , Ablación por Catéter/métodos , Cabello , Resultado del Tratamiento
15.
JACC Clin Electrophysiol ; 9(11): 2303-2314, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37632506

RESUMEN

BACKGROUND: Intramural hematoma during ablation for scar-related ventricular tachycardia (VT) is a rare but life-threatening complication. OBJECTIVES: The goal of this study was to describe the features and outcomes of intramural hematoma during ablation for scar-related VT. METHODS: From 2010 to 2022, >3,514 ablations for ventricular arrhythmias were performed at 2 institutions. Four cases of intramural hematoma complicating VT ablation for scar-related VT were identified. Intraprocedural details, imaging data, and surgical notes were reviewed to create a recognizable pattern of events highlighting this complication. RESULTS: In 3 of 4 cases, intramural hematoma occurred during catheter ablation with an open irrigated 3.5 mm tipped catheter using normal saline for irrigation. In one case, hematoma was noted after ablation using an investigational needle electrode catheter. The occurrence of a steam pop preceded detection of an expanding intramural hematoma in 3 cases. ST-segment elevation on electrocardiography was evident in 3 cases; intracardiac echocardiographic imaging detected the hematoma in all cases. Epicardial rupture and pericardial effusion requiring drainage occurred in 3 cases, whereas 1 hematoma was self-contained and did not require intervention. Surgical intervention was performed in 2 cases, with successful outcomes. One patient who was deemed not a surgical candidate died of progressive cardiogenic shock. CONCLUSIONS: Intramural hematoma during ablation for scar-related VT is a rare but potentially catastrophic complication that requires prompt recognition. Steam pops during ablation frequently precede the hematoma formation. Surgical intervention may be life-saving, although contained hematomas can occasionally be managed conservatively.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Cicatriz/complicaciones , Cicatriz/cirugía , Cicatriz/patología , Vapor , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/diagnóstico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Hematoma/diagnóstico por imagen , Hematoma/etiología , Hematoma/cirugía
17.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1147-1157, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37495323

RESUMEN

BACKGROUND: Experimental evidence suggests genetic variation in 4q25/PITX2 modulates pulmonary vein (PV) myocardial sleeve length. Although PV sleeves are the main target of atrial fibrillation (AF) ablation, little is known about the association between different PV sleeve characteristics with ablation outcomes. OBJECTIVES: This study sought to evaluate the association between clinical and genetic (4q25) risk factors with PV sleeve length in humans, and to evaluate the association between PV sleeve length and recurrence after AF ablation. METHODS: In a prospective, observational study of patients undergoing de novo AF ablation, PV sleeve length was measured using electroanatomic voltage mapping before ablation. The sentinel 4q25 AF susceptibility single nucleotide polymorphism, rs2200733, was genotyped. The primary analysis tested the association between clinical and genetic (4q25) risk factors with PV sleeve length using a multivariable linear regression model. Covariates included age, sex, body mass index, height, and persistent AF. The association between PV sleeve length and atrial arrhythmia recurrence (>30 seconds) was tested using a multivariable Cox proportional hazards model. RESULTS: Between 2014 and 2019, 197 participants were enrolled (median age 63 years [IQR: 55 to 70 years], 133 male [67.5%]). In multivariable modeling, men were found to have PV sleeves 2.94 mm longer than women (95% CI: 0.99-4.90 mm; P < 0.001). Sixty participants (30.5%) had one 4q25 risk allele and 6 (3.1%) had 2 alleles. There was no association between 4q25 genotype and PV sleeve length. Forty-six participants (23.4%) experienced arrhythmia recurrence within 3 to 12 months, but there was no association between recurrence and PV sleeve length. CONCLUSIONS: Common genetic variation at 4q25 was not associated with PV sleeve length and PV sleeve length was not associated with ablation outcomes. Men did have longer PV sleeves than women, but more research is needed to define the potential clinical significance of this observation.


Asunto(s)
Fibrilación Atrial , Venas Pulmonares , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Atrial/genética , Fibrilación Atrial/cirugía , Genotipo , Estudios Prospectivos , Venas Pulmonares/cirugía , Factores de Riesgo , Anciano , Proteína del Homeodomínio PITX2
18.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1475-1486, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37278684

RESUMEN

BACKGROUND: We previously reported feasibility of irrigated needle ablation (INA) with a retractable 27-G end-hole needle catheter to treat nonendocardial ventricular arrhythmia substrate, an important cause of ablation failure. OBJECTIVES: The purpose of this study was to report outcomes and complications in our entire INA-treated population. METHODS: Patients with recurrent sustained monomorphic ventricular tachycardia (VT) or high-density premature ventricular contractions (PVCs) despite radiofrequency ablation were prospectively enrolled at 4 centers. Endpoints included a 70% decrease in VT frequency or PVC burden decrease to <5,000/24 h at 6 months. RESULTS: INA was performed in 111 patients (median: 2 failed prior ablations, 71% nonischemic heart disease, and left ventricular ejection fraction 36% ± 14%). INA acutely abolished targeted PVCs in 33 of 37 patients (89%), and PVCs were reduced to <5,000/day in 29 patients (78%). During 6-month follow-up, freedom from hospitalization was observed in 50 of 72 patients with VT (69%), and improvement or abolition of VT occurred in 47%. All patients received multiple INA applications, with more in the VT group than in the PVC group (median: 12 [IQR: 7-19] vs 7 [5-15]; P < 0.01). After INA, additional endocardial standard radiofrequency ablation was required in 23% of patients. Adverse events included 4 pericardial effusions (3.5%), 3 cases of (anticipated) atrioventricular block (2.6%), and 3 heart failure exacerbations (2.6%). During 6-month follow-up, 5 deaths occurred; none were procedure-related. CONCLUSIONS: INA achieves improved arrhythmia control in 78% of patients with PVCs and avoids hospitalization in 69% of patients with VT refractory to standard ablation at 6-month follow-up. Procedural risks are acceptable. (Intramural Needle Ablation for Ablation of Recurrent Ventricular Tachycardia, NCT01791543; Intramural Needle Ablation for the Treatment of Refractory Ventricular Arrhythmias, NCT03204981).


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Humanos , Ablación por Catéter/efectos adversos , Volumen Sistólico , Función Ventricular Izquierda
20.
Circ Arrhythm Electrophysiol ; 16(2): e010889, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36602818

RESUMEN

BACKGROUND: Initiation of ventricular tachycardia (VT) by programmed electrical stimulation (PES) has an important role to allow mapping and assess ablation end points. We hypothesized that substrate mapping may alter VT inducibility by mechanical bumping of critical sites. METHODS: Subjects with left ventricular scar-related VT that was inducible by PES who were undergoing ablation were included. PES was repeated after substrate mapping (Group I) or after time under sedation/anesthesia during which additional imaging and transeptal puncture were performed without substrate mapping (Group II). The response to the second PES was categorized as type I if the same VT was induced, type II if a different VT was induced, and type III if VT was not inducible. RESULTS: Twenty-eight patients (median age 66 years, 61% ischemic cardiomyopathy), 14 in Group I and 14 in Group II, were included. Age, time between initial and second PES, type of cardiomyopathy, ejection fraction, and anesthesia methods were not different between the 2 groups. Initial VT cycle length, however, was shorter in Group I (305 millisecond [range, 235-600] versus 350 millisecond [range, 235-600], P=0.016). Also, Group I required more extrastimuli to induce VT in PES 1 (2 [1-4] versus 2 [1-3], P=0.022). In Group I, following substrate mapping, the second PES induced the same VT in 3 patients (21%), a different VT in 9 (64%), and no VT in 2 (14%) patients. In contrast, in Group II the same VT was induced in 10 (71%) patients, a different VT in 3 (21%) and no VT in 1 (7%) patient (P=0.017). CONCLUSIONS: Mechanical effects of substrate mapping commonly alter inducibility of VT. This has important implications for catheter ablation procedure planning and acute assessment of outcome and can potentially account for some recurrent VTs that are not recognized at the time of the procedure.


Asunto(s)
Anestesia , Cardiomiopatías , Ablación por Catéter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Anciano , Cardiomiopatías/cirugía , Ablación por Catéter/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA