Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 236
Filtrar
1.
J Vasc Access ; : 11297298241246300, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38659089

RESUMEN

BACKGROUND: There is little information regarding complications of arterial catheterization in modern clinical care. We aimed to determine the incidence of abnormal duplex vascular ultrasound and catheter related infections following perioperative arterial catheterization. METHODS: Patients requiring arterial catheterization for elective surgery were included and insertion details collected prospectively. Duplex ultrasound evaluation was performed 24 h after catheter removal. Symptomatic patients were identified by self-reported questionnaire. On Day 7, patients answered questions by telephone, related to the insertion site, pain, and function. Results of catheter tip and blood culture analyses were sought. Univariate associations of patient and surgical characteristics with abnormal ultrasound were assessed with p < 0.05 considered significant. RESULTS: Of 339 catheterizations, 105 (40%) had ultrasound evaluation. Catheters were indwelling for median (IQR, range) duration of 6.0 h (4.4-8.2, 1.8-28) with no catheter-related infections. There were 16 (15.2%, 95% CI 9.0%-23.6%) abnormal results, including 14 radial artery thromboses, one radial artery dissection, and one radial vein thrombosis. Those with abnormal ultrasound results were more likely to have had Arrow catheters inserted (68.8% vs 27%, p = 0.023) and more than one skin puncture (37.5% vs 26.8%, p = 0.031). Two of the 16 (12.5%) patients with abnormal ultrasound results reported new symptoms related to the hand compared with nine of the 88 (10.2%) with normal results (p = 0.1). No patients required urgent referral for management. CONCLUSIONS: Thrombosis was the most common abnormality and was usually asymptomatic. There were no infections, few post-operative symptoms, and minimal functional impairment following arterial catheterization.

2.
Semin Oncol Nurs ; : 151618, 2024 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-38622044

RESUMEN

OBJECTIVES: To identify the prevalence and type of central venous access device-associated skin complications for adult cancer patients, describe central venous access device management practices, and identify clinical and demographic characteristics associated with risk of central venous access device-associated skin complications. METHODS: A prospective cohort study of 369 patients (626 central venous access devices; 7,682 catheter days) was undertaken between March 2017 and March 2018 across two cancer care in-patient units in a large teaching hospital. RESULTS: Twenty-seven percent (n = 168) of participants had a central venous access device-associated skin complication. In the final multivariable analysis, significant (P < .05) risk factors for skin complications were cutaneous graft versus host disease (2.1 times greater risk) and female sex (1.4 times greater risk), whereas totally implanted vascular access device reduced risk for skin complications by two-thirds (incidence risk ratio 0.37). CONCLUSION: Central venous access device-associated skin complications are a significant, potentially avoidable injury, requiring cancer nurses to be aware of high-risk groups and use evidence-based preventative and treatment strategies. IMPLICATIONS FOR PRACTICE: This study has confirmed how common these potentially preventable injuries are. Therefore, the prevalence of these complications could be reduced by focusing on improvements in skin assessment, reductions in central venous access device dressing variation and improving clinician knowledge of this injury.

3.
J Intensive Care ; 12(1): 12, 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38459599

RESUMEN

OBJECTIVES: Arterial catheters (ACs) are critical for haemodynamic monitoring and blood sampling but are prone to complications. We investigated the incidence and risk factors of AC failure. METHODS: Secondary analysis of a multi-centre randomised controlled trial (ACTRN 12610000505000). Analysis included a subset of adult intensive care unit patients with an AC. The primary outcome was all-cause device failure. Secondary outcomes were catheter associated bloodstream infection (CABSI), suspected CABSI, occlusion, thrombosis, accidental removal, pain, and line fracture. Risk factors associated with AC failure were investigated using Cox proportional hazards and competing-risk models. RESULTS: Of 664 patients, 173 (26%) experienced AC failure (incidence rate [IR] 37/1000 catheter days). Suspected CABSI was the most common failure type (11%; IR 15.3/1000 catheter days), followed by occlusion (8%; IR 11.9/1,000 catheter days), and accidental removal (4%; IR 5.5/1000 catheter days). CABSI occurred in 16 (2%) patients. All-cause failure and occlusion were reduced with ultrasound-assisted insertion (failure: adjusted hazard ratio [HR] 0.43, 95% CI 0.25, 0.76; occlusion: sub-HR 0.11, 95% CI 0.03, 0.43). Increased age was associated with less AC failure (60-74 years HR 0.63, 95% CI 0.44 to 0.89; 75 + years HR 0.36, 95% CI 0.20, 0.64; referent 15-59 years). Females experienced more occlusion (adjusted sub-HR 2.53, 95% CI 1.49, 4.29), while patients with diabetes had less (SHR 0.15, 95% CI 0.04, 0.63). Suspected CABSI was associated with an abnormal insertion site appearance (SHR 2.71, 95% CI 1.48, 4.99). CONCLUSIONS: AC failure is common with ultrasound-guided insertion associated with lower failure rates. Trial registration Australian New Zealand Clinical Trial Registry (ACTRN 12610000505000); date registered: 18 June 2010.

4.
J Infus Nurs ; 47(2): 75-95, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38422403

RESUMEN

Ultrasound-guided insertion of peripheral intravenous catheters (PIVCs) is recommended for patients with difficult intravenous access, but access to ultrasound equipment is often limited to specialty departments. Compact, affordable handheld ultrasound devices are available, but the extent of their clinical adoption and impact on patient outcomes is unknown. This scoping review aimed to explore evidence regarding handheld and pocket ultrasound devices for PIVC insertion. Databases were searched for studies published in English between January 2000 and January 2023 evaluating handheld or pocket ultrasound devices weighing ≤3 kg for PIVC insertion. Data were extracted using standardized forms and summarized using descriptive statistics. Seventeen studies reporting the use of handheld or pocket ultrasound devices were identified. Most studies were conducted in adult inpatient facilities; 3 included pediatrics, and 2 reported out-of-hospital use. Participants with difficult intravenous access featured in 9 studies. Ultrasound training programs were described in 12 studies, with competency defined by number of successful PIVC insertions. Five studies reported clinician and/or patient perspectives. Ultrasound for PIVC insertion is not widely accessible in nonspecialist areas, but more compact and affordable handheld models could provide a solution, especially for patients with difficult access. More research evidence using handheld ultrasound is needed.


Asunto(s)
Cateterismo , Adulto , Humanos , Niño , Administración Intravenosa , Bases de Datos Factuales
5.
J Clin Nurs ; 33(5): 1762-1776, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38413831

RESUMEN

BACKGROUND: Healthcare consumers require diverse resources to assist their navigation of complex healthcare interactions, however, these resources need to be fit for purpose. AIM: In this study, we evaluated the utility, usability and feasibility of children, families and adults requiring long-term intravenous therapy using a recently developed mobile health application (App), intravenous (IV) Passport. DESIGN: Multi-site, parallel, multi-method, prospective cohort study. METHODS: A multi-site, multi-method study was carried out in 2020-2021, with 46 participants (20 adults, 26 children/family) reporting on their experiences surrounding the use of the IV Passport for up to 6 months. RESULTS: Overall, utility rates were acceptable, with 78.3% (N = 36) using the IV Passport over the follow-up period, with high rates of planned future use for those still active in the project (N = 21; 73%), especially in the child/family cohort (N = 13; 100%). Acceptability rates were high (9/10; IQR 6.5-10), with the IV Passport primarily used for documenting new devices and complications. Thematic analysis revealed three main themes (and multiple subthemes) in the qualitative data: Advocacy for healthcare needs, Complexity of healthcare and App design and functionality. CONCLUSION: Several recommendations were made to improve the end-user experience including 'how to' instructions; and scheduling functionality for routine care. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: The IV Passport can be safely and appropriately integrated into healthcare, to support consumers. IMPACT: Patient-/parent-reported feedback suggests the Intravenous Passport is a useful tool for record-keeping, and positive communication between patients/parents, and clinicians. REPORTING METHOD: Not applicable. PATIENT CONTRIBUTION: Consumers reported their experiences surrounding the use of the IV Passport for up to 6 months.


Asunto(s)
Telemedicina , Adulto , Niño , Humanos , Estudios Prospectivos , Telemedicina/métodos , Atención a la Salud , Padres , Comunicación
6.
J Pediatr Nurs ; 76: 68-75, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38364591

RESUMEN

PURPOSE: Children with chronic and complex health conditions frequently need intravenous devices. The current approach to intravenous device selection, insertion, and monitoring is inconsistent, and healthcare consumers are often negatively affected by siloed health information, and poor future planning. Despite child- and family-centred care being recognised as a pillar of paediatric nursing care, limited implementation for vascular access device planning and management is evident. DESIGN AND METHODS: To address this, we conducted a multi-phased approach to co-create, then evaluate, a mobile health (mHealth) application: IV Passport. Co-creation involved a prioritisation survey, followed by a Passport advisory panel consensus meeting. Following confirmation of the required content and features of the Passport, the mHealth application was designed and content validation achieved via survey. RESULTS: The prioritisation survey yielded recommendations for seven features (e.g., graphical presentations of current/past devices). Content for nine device types (e.g., totally implanted ports) was suggested, each with 10 related items (e.g., insertion site). Content items for device-associated complications, future vascular access plans, and educational resources were also suggested. Following design, the application was released through Apple and Android platforms; and adapted to a paper version. Content validation was established; 100% strongly agreed the application was easy to use; 80% agreed/strongly agreed that they would recommend the Passport to others. CONCLUSION: IV Passport embodies effective child- and family-centred care through consumer co-creation to empower patients and families manage vascular access devices. PRACTICE IMPLICATIONS: IV Passport remains active; and can be utilised across many healthcare settings and patient populations.


Asunto(s)
Telemedicina , Dispositivos de Acceso Vascular , Humanos , Niño , Aplicaciones Móviles , Masculino , Femenino , Enfermedad Crónica , Enfermería Pediátrica
7.
Health Qual Life Outcomes ; 22(1): 1, 2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38167165

RESUMEN

BACKGROUND: Peripheral intravenous catheters (PIVCs) are essential for successful administration of intravenous treatments. However, insertion failure and PIVC complications are common and negatively impact patients' health-outcomes and experiences. We aimed to assess whether generic (not condition-specific) quality of life and experience measures were suitable for assessing outcomes and experiences of patients with PIVCs. METHODS: We undertook a secondary analysis of data collected on three existing instruments within a large randomised controlled trial, conducted at two adult tertiary hospitals in Queensland, Australia. Instruments included the EuroQol Five Dimension - Five Level (EQ5D-5L), the Functional Assessment of Chronic Illness Therapy - Treatment Satisfaction - General measure (FACIT-TS-G, eight items), and the Australian Hospital Patient Experience Question Set (AHPEQS, 12 items). Responses were compared against two clinical PIVC outcomes of interest: all-cause failure and multiple insertion attempts. Classic descriptives were reported for ceiling and floor effects. Regression analyses examined validity (discrimination). Standardised response mean and effect size (ES) assessed responsiveness (EQ5D-5L, only). RESULTS: In total, 685 participants completed the EQ5D-5L at insertion and 526 at removal. The FACIT-TS-G was completed by 264 and the AHPEQS by 262 participants. Two FACIT-TS-G items and one AHPEQS item demonstrated ceiling effect. Instruments overall demonstrated poor discrimination, however, all-cause PIVC failure was significantly associated with several individual items in the instruments (e.g., AHPEQS, 'unexpected physical and emotional harm'). EQ5D-5L demonstrated trivial (ES < 0.20) responsiveness. CONCLUSIONS: Initial investigation of an existing health-related quality of life measure (EQ5D-5L) and two patient-reported experience measures (FACIT-TS-G; AHPEQS) suggest they are inadequate (as a summary measure) to assess outcomes and experiences for patients with PIVCs. Reliable instruments are urgently needed to inform quality improvement and benchmark standards of care.


Asunto(s)
Calidad de Vida , Análisis de Datos Secundarios , Adulto , Humanos , Australia , Queensland , Catéteres
8.
Aust Crit Care ; 37(3): 495-498, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37385895

RESUMEN

BACKGROUND: Infusion sets (comprising the tubing, measuring burettes, fluid containers, transducers) that are connected to invasive vascular devices are changed on a regular basis in an effort to reduce bacterial colonisation and bloodstream infection. There is a balance between reducing infection and creating unnecessary waste. Current evidence suggests that for central venous catheters (CVCs), changing infusion sets at 7 days does not increase infection risks. OBJECTIVES: The objective of this study was to describe the current unit guidelines in Australian and New Zealand intensive care units (ICUs) for changing infusion sets for CVCs. METHODS: prospective cross-sectional point prevalence study, as a part of the 2021 Australian and New Zealand Intensive Care Society Point Prevalence Program. PARTICIPANTS: Australia and New Zealand (ANZ) adult ICUs and their patients on the day of the study. RESULTS: Data were collected from 51 ICUs across ANZ. One-third of these (16/49) ICUs had a guideline that specified a 7-day replacement period, with the rest having a more frequent replacement period. CONCLUSION: Most ICUs participating in this survey had policies to change their CVC infusion tubing in 3-4 days, and recent high-level evidence supports an update to extend this to 7 days. There remains work to be done to spread this evidence to ANZ ICUs and improve environmental sustainability initiatives.


Asunto(s)
Catéteres Venosos Centrales , Adulto , Humanos , Estudios Transversales , Nueva Zelanda/epidemiología , Prevalencia , Estudios Prospectivos , Australia/epidemiología , Unidades de Cuidados Intensivos
9.
Int J Nurs Stud ; 151: 104673, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38142634

RESUMEN

BACKGROUND: Peripheral intravenous catheters are the most frequently used invasive device in nursing practice, yet are commonly associated with complications. We performed a systematic review to determine the prevalence of peripheral intravenous catheter infection and all-cause failure. METHODS: The Cochrane Library, PubMed, CINAHL, and EMBASE were searched for observational studies and randomised controlled trials that reported peripheral intravenous catheter related infections or failure. The review was limited to English language and articles published from the year 2000. Pooled estimates were calculated with random-effects models. Meta-analysis of observation studies in epidemiology guidelines and the Cochrane process for randomised controlled trials were used to guide the review. Prospero registration number: CRD42022349956. FINDINGS: Our search retrieved 34,725 studies. Of these, 41 observational studies and 28 randomised controlled trials (478,586 peripheral intravenous catheters) met inclusion criteria. The pooled proportion of catheter-associated bloodstream infections was 0.028 % (95 % confidence interval (CI): 0.009-0.081; 38 studies), or 4.40 catheter-associated bloodstream infections per 100,000 catheter-days (20 studies, 95 % CI: 3.47-5.58). Local infection was reported in 0.150 % of peripheral intravenous catheters (95 % CI: 0.047-0.479, 30 studies) with an incidence rate of 65.1 per 100,000 catheter-days (16 studies; 95 % CI: 49.2-86.2). All cause peripheral intravenous catheter failure before treatment completion occurred in 36.4 % of catheters (95 % CI: 31.7-41.3, 53 studies) with an overall incidence rate of 4.42 per 100 catheter days (78,891 catheter days; 19 studies; 95 % CI: 4.27-4.57). INTERPRETATION: Peripheral intravenous catheter failure is a significant worldwide problem, affecting one in three catheters. Per peripheral intravenous catheter, infection occurrence was low, however, with over two billion catheters used globally each year, the absolute number of infections and associated burden remains high. Substantial and systemwide efforts are needed to address peripheral intravenous catheter infection and failure and the sequelae of treatment disruption, increased health costs and poor patient outcomes.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Periférico , Flebitis , Sepsis , Humanos , Flebitis/etiología , Infecciones Relacionadas con Catéteres/epidemiología , Catéteres , Cateterismo Periférico/efectos adversos , Sepsis/complicaciones
11.
Int Emerg Nurs ; 71: 101366, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37852059

RESUMEN

BACKGROUND: Peripheral intravenous catheters (PIVCs) are commonly used devices in emergency departments (EDs), and yet relatively little is known about factors influencing Australian clinicians' adherence to the national PIVC quality and safety Standard. AIMS: To explore attitudes and experiences of ED clinicians around PIVC insertion and care processes. METHODS: This study used an exploratory qualitative approach to analyse written responses to open-ended questions included in an online national (mixed data) survey. Snowballing methods were used to gather responses. Deductive analysis was used to analyse open-ended questions regarding practice and Standard adherence. RESULTS: There were 340 written responses, mainly from nurses in public EDs, who reported suboptimal practices regarding idle catheters, lack of patient participation in care, antecubital fossa insertion, multiple insertion attempts, inadequate site preparation, poor documentation and insufficient review of PIVC. The main factors inhibiting ED clinicians from adhering to the Standard includes inadequate knowledge, perceptions of infeasibility, disbelief in evidence, ambiguous responsibilities, habitual practice, insufficient training, lack of recognition of good practice and inadequate engagement. CONCLUSION: The factors that impact ED clinicians' PIVC Standard adherence are complex and multifactorial. Strategies and interventions are needed to facilitate the implementation of the Standard into daily practice and achieve sustainable behaviour change.


Asunto(s)
Cateterismo Periférico , Humanos , Australia , Encuestas y Cuestionarios , Cateterismo Periférico/métodos , Servicio de Urgencia en Hospital , Catéteres
12.
Int J Nurs Stud ; 148: 104604, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37801935

RESUMEN

BACKGROUND: Peripheral intravenous catheters are the most widely used invasive device in hospitals but have serious risks. OBJECTIVE: To determine if a structured assessment and decision tool (I-DECIDED®) improves daily peripheral intravenous catheter assessment and care decisions. DESIGN: Prospective, interrupted time-series study. SETTINGS: Seven adult inpatient wards in three Australian hospitals. PARTICIPANTS: 825 adults with 867 peripheral intravenous catheters. METHODS: Between August 2017 and December 2018, peripheral intravenous catheter assessments and chart audits were undertaken with informed patient consent. Following a 4-month pre-intervention period (with 2-weekly measures), the I-DECIDED® tool was implemented over 3 months (no data collection) using multiple strategies (stakeholder meetings, vascular access device form, education sessions, ward champions, lanyard cards, and posters), followed by a 4-month post-intervention period (with 2-weekly measures). Primary outcomes were device utilization (number of peripheral intravenous catheters per total number of patients screened); idle/unused catheters; insertion site complications, substandard dressing quality; and primary bloodstream infections. RESULTS: Of 2055 patients screened, 1175 (57.2%) had a peripheral intravenous catheter, and 825 patients (867 catheters) consented and were included in the final analysis. Device utilization increased from 42.0% of catheters at baseline to 49.6% post-intervention (absolute risk difference [ARD] 7.5%, 95% confidence interval [CI] 4.8, 10.3; relative risk [RR] 1.18, 95% CI 1.11, 1.25; p < 0.001). The proportion of idle catheters reduced from 12.7% to 8.3% (ARD -4.4%, 95% CI -8.5, -0.3; RR 0.66, 95% CI 0.44, 0.97; p = 0.035). Peripheral intravenous catheter complications reduced from 16.1% to 10.9% (ARD -5.2%, 95% CI -9.7, -0.6; RR 0.68, 95% CI 0.48, 0.96; p = 0.026). Substandard dressings reduced from 24.6% to 19.5% (ARD -5.2%, 95% CI -10.7, 0.4; RR 0.79, 95% CI 0.61, 1.02; p = 0.067). Only one primary bloodstream infection occurred (post-intervention). CONCLUSIONS: Implementation of a comprehensive device assessment and decision tool (I-DECIDED®) reduced idle catheters and catheter complications, despite higher device utilization. Dressing quality improved but was not statistically significant. Further implementation of the tool could improve hospital safety for patients with an intravenous catheter. ANZCTR TRIAL REGISTRATION: ACTRN12617000067370. Date of registration 13 January 2017. Date of first data collection 3rd August 2017. TWEETABLE ABSTRACT: #IDECIDEDassessment reduces prevalence of idle peripheral catheters and device complications.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Periférico , Adulto , Humanos , Infecciones Relacionadas con Catéteres/prevención & control , Estudios Prospectivos , Mejoramiento de la Calidad , Australia , Catéteres , Cateterismo Periférico/efectos adversos
13.
JAMA Pediatr ; 177(11): 1132-1140, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37695594

RESUMEN

Importance: Peripheral intravenous catheters (PIVCs) frequently fail during treatment causing therapy interruption, pain, recatheterization, and additional health care costs. Midline catheters (MCs) may improve functional dwell time and reduce failure compared with traditional PIVCs. Objective: To compare device failure of MCs with PIVCs. Design, Setting, and Participants: This was a pragmatic, randomized clinical superiority trial with an embedded internal pilot study conducted from July 2020 to May 2022. The study took place in a quaternary pediatric hospital in Brisbane, Queensland, Australia. Inclusion criteria were patients aged 1 to 18 years requiring peripherally compatible intravenous therapy for 4 days or longer. Interventions: Patients were randomly assigned 1:1 to receive a PIVC or MC, stratified by age (≤5 years, >5 years). One catheter was studied per patient. Main Outcomes and Measures: The primary outcome was all-cause device failure, defined as premature cessation of device function. Secondary outcomes included number of insertion attempts, insertion failure, pain (on insertion), procedural time, patient/parent satisfaction (with insertion), device dwell time, device complications during dwell time, additional vascular access devices required to complete treatment, clinician satisfaction (at removal), and health care costs. Results: Of the 128 patients randomly assigned to study groups, 127 patients (median [IQR] age, 7 [2-13] years; 71 male [56%]) had a device inserted, with 65 (51.2%) in the PIVC group and 62 (48.8%) in the MC group. All patients were included in the intention-to-treat analysis. Device failure was lower in patients in the MC group (10 [16.1%]) compared with those in the PIVC group (30 [46.2%]; odds ratio [OR], 0.22; 95% CI, 0.10-0.52; P <.001). MCs were associated with fewer insertion attempts (mean difference [MD], -0.3; 95% CI, -0.5 to 0; P = .04), increased dwell time (MD, 66.9 hours; 95% CI, 36.2-97.5 hours; P <.001), and fewer patients required additional vascular access devices to complete treatment in the MC group (4 [6.5%]) and PIVC group (19 [29.2%]; OR, 0.17; 95% CI, 0.05-0.52; P = .002). Compared with PIVCs, use of MCs was associated with greater patient (9.0 vs 7.1 of 10; P = .002) and parent (9.1 vs 8.2 of 10; P = .02) satisfaction and lower health care costs (AUS -$151.67 [US -$101.13] per person; 95% credible interval, AUS -$171.45 to -$131.90 [US -$114.20 to -$87.95]). Conclusions and Relevance: Findings suggest that MC insertion for patients requiring peripherally compatible intravenous therapy for 4 days or longer should be prioritized to reduce the resource intensive, expensive, and burdensome sequelae of device failure. Trial Registration: Australia New Zealand Clinical Trials Registry, ACTRN12620000724976.


Asunto(s)
Cateterismo Periférico , Adolescente , Niño , Preescolar , Humanos , Masculino , Australia , Cateterismo Periférico/efectos adversos , Catéteres , Falla de Equipo , Dolor/etiología , Proyectos Piloto , Femenino
14.
J Clin Nurs ; 32(21-22): 7909-7919, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37587796

RESUMEN

AIM: To test the feasibility of a study protocol that compared the efficacy of neutral- and negative-pressure needleless connectors (NCs). DESIGN: A single-centre, parallel-group, pilot randomised control trial. METHODS: Our study compared neutral-(intervention) and negative-pressure (control) NCs among adult patients in an Australian hospital. The primary feasibility outcome was measured against predetermined criteria (e.g. eligibility, attrition). The primary efficacy outcome was all-cause peripheral intravenous catheter failure, analysed as time-to-event data. RESULTS: In total, 201 (100 control; 101 intervention) participants were enrolled between March 2020 and September 2020. All feasibility criteria were met except eligibility, which was lower (78%) than the 90% criterion. All-cause peripheral intravenous catheter failure was significantly higher in the intervention group (39%) compared to control (19%). CONCLUSION: With minor modifications to participant screening for eligibility, this randomised control trial is feasible for a large multicentre randomised control trial. The neutral NC was associated with an increased risk of peripheral intravenous catheter failure. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: There are several NC designs available, often identified by their mechanism of pressure (positive, negative and neutral). However, NCs can contribute to peripheral intravenous catheter failure. This is the first randomised controlled trial to compare neutral and negative NC designs. Negative pressure NCs had lower PIVC failure compared to neutral NCs, however the results might not be generalisable to other brands or treatment settings. Further high-quality research is needed to explore NC design. REPORTING METHOD: Study methods and results reported in adherence to the CONSORT Statement. PATIENT OR PUBLIC CONTRIBUTION: No patient or public contribution.

16.
BMC Health Serv Res ; 23(1): 587, 2023 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-37286977

RESUMEN

BACKGROUND: Peripheral intravenous catheters (PIVCs) are the most used invasive medical device in healthcare. Yet around half of insertion attempts are unsuccessful leading to delayed medical treatments and patient discomfort of harm. Ultrasound-guided PIVC (USGPIVC) insertion is an evidence-based intervention shown to improve insertion success especially in patients with Difficult IntraVenous Access (BMC Health Serv Res 22:220, 2022), however the implementation in some healthcare settings remains suboptimal. This study aims to co-design interventions that optimise ultrasound guided PIVC insertion in patients with DIVA, implement and evaluate these initiatives and develop scale up activities. METHODS: A stepped-wedge cluster randomized controlled trial will be conducted in three hospitals (two adult, one paediatric) in Queensland, Australia. The intervention will be rolled out across 12 distinct clusters (four per hospital). Intervention development will be guided by Michie's Behavior Change Wheel with the aim to increase local staff capability, opportunity, and motivation for appropriate, sustainable adoption of USGPIVC insertion. Eligible clusters include all wards or departments where > 10 PIVCs/week are typically inserted. All clusters will commence in the control (baseline) phase, then, one cluster per hospital will step up every two months, as feasible, to the implementation phase, where the intervention will be rolled out. Implementation strategies are tailored for each hospital by local investigators and advisory groups, through context assessments, staff surveys, and stakeholder interviews and informed by extensive consumer interviews and consultation. Outcome measures align with the RE-AIM framework including clinical-effectiveness outcomes (e.g., first-time PIVC insertion success for DIVA patients [primary outcome], number of insertion attempts); implementation outcomes (e.g., intervention fidelity, readiness assessment) and cost effectiveness outcomes. The Consolidated Framework for Implementation Research framework will be used to report the intervention as it was implemented; how people participated in and responded to the intervention; contextual influences and how the theory underpinning the intervention was realised and delivered at each site. A sustainability assessment will be undertaken at three- and six-months post intervention. DISCUSSION: Study findings will help define systematic solutions to implement DIVA identification and escalation tools aiming to address consumer dissatisfaction with current PIVC insertion practices. Such actionable knowledge is critical for implementation of scale-up activities. TRIAL REGISTRATION: Prospectively registered (Australian and New Zealand Clinical Trials Registry; ACTRN12621001497897).


Asunto(s)
Hospitales , Tecnología , Adulto , Humanos , Niño , Australia , Queensland , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto
17.
JPEN J Parenter Enteral Nutr ; 47(6): 783-795, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37288612

RESUMEN

BACKGROUND: Distinguishing primary bloodstream infections (BSIs) related to central venous access devices (CVADs) from those that occur through other mechanisms, such as a damaged mucosal barrier, is difficult. METHODS: Secondary analysis was conducted on data from patients with CVADs that were collected for a large, randomized trial. Patients were divided into two groups: those who received parenteral nutrition (PN)-containing intravenous lipid emulsion (ILE) and those who did not have PN-containing ILE. This study investigated the influence of PN-containing ILE (ILE PN) on primary BSIs in patients with a CVAD. RESULTS: Of the 807 patients, 180 (22%) received ILE PN. Most (627/807; 73%) were recruited from the hematology and hematopoietic stem cell transplant unit, followed by surgical (90/807; 11%), trauma and burns (61/807; 8%), medical (44/807; 5%), and oncology (23/807; 3%). When primary BSI was differentiated as a central line-associated BSI (CLABSI) or mucosal barrier injury laboratory-confirmed BSI (MBI-LCBI), the incidence of CLABSI was similar in the ILE PN and non-ILE PN groups (15/180 [8%] vs 57/627 [9%]; P = 0.88) and the incidence of MBI-LCBI was significantly different between groups (31/180 [17%] ILE PN vs 41/627 [7%] non-ILE PN; P < 0.01). CONCLUSION: Our data indicate that twice as many primary BSIs in ILE PN patients are due to MBIs than CVADs. It is important to consider the MBI-LCBI classification, as some CLABSI prevention efforts aimed at CVADs for the ILE PN population may be better directed to gastrointestinal tract protection interventions.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Catéteres Venosos Centrales , Sepsis , Humanos , Emulsiones Grasas Intravenosas , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/prevención & control , Infecciones Relacionadas con Catéteres/etiología , Sepsis/complicaciones , Membrana Mucosa , Nutrición Parenteral/efectos adversos , Catéteres Venosos Centrales/efectos adversos , Estudios Retrospectivos , Cateterismo Venoso Central/efectos adversos
18.
J Ultrasound Med ; 42(11): 2525-2534, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37306253

RESUMEN

INTRODUCTION: There is a lack of international consensus as to whether high- or low-level disinfection (HLD or LLD) is required for ultrasound (US) transducers used during percutaneous procedures. This study compared the effectiveness of LLD to HLD on US transducers contaminated with microorganisms from skin. METHODS: Two identical linear US transducers repeatedly underwent either LLD or HLD during the study. Randomization determined which of these transducers was applied to left and right forearms of each participant. Swabs taken from transducers before and after reprocessing were plated then incubated for 4-5 days, after which colony forming units (CFU) were counted and identified. The primary hypothesis was the difference in the proportion of US transducers having no CFUs remaining after LLD and HLD would be less than or equal to the noninferiority margin of -5%. RESULTS: Of the 654 recruited participants 73% (n = 478) had microbial growth from both transducers applied to their left and right forearms before reprocessing. These were included in the paired noninferiority statistical analysis where, after disinfection, all CFUs were eliminated in 100% (95% CI: 99.4-100.0%) of HLD transducer samples (n = 478) and 99.0% (95% CI: 97.6-99.7%) of LLD transducer samples (n = 473). The paired difference in the proportion of transducers having all CFUs eliminated between LLD and HLD was -1.0% (95% CI: -2.4 to -0.2%, P-value <.001). CONCLUSIONS: Disinfection with LLD is noninferior to HLD when microorganisms from skin have contaminated the transducer. Therefore, using LLD for US transducers involved in percutaneous procedures would present no higher infection risk compared with HLD.

19.
Ann Intensive Care ; 13(1): 46, 2023 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-37227571

RESUMEN

Central venous catheterization (CVC) is a frequent procedure, practiced by intensivists, anesthesiologists and advanced practice nurses in intensive care units and operative rooms. To reduce CVC-associated morbidity, it is essential to strive for best practices, based on the latest evidence. This narrative review aims to synthesize current knowledge on evidence-based best practices for CVC that improve the use and feasibility of real-time ultrasound-guided insertion procedures. Optimization of the vein puncture technique and the development of new technologies are discussed to reinforce the use of the subclavian vein catheterization as first choice. The search for alternative site of insertions, without increasing infectious and thrombotic risks, deserves further research.

20.
Infect Dis Health ; 28(4): 259-264, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37142538

RESUMEN

BACKGROUND: Midline catheter (MC) use has increased in acute-care settings, particularly for patients with difficult venous access or requiring peripherally compatible intravenous therapy for up-to 14 days. Our aim was to assess feasibility and generate clinical data comparing MCs with Peripherally Inserted Central Catheters (PICCs). METHODS: A two-arm parallel group pilot randomised controlled trial (RCT), comparing MCs with PICCs, was conducted in a large tertiary hospital in Queensland between September 2020 and January 2021. The primary outcome was study feasibility, measured against rates of eligibility (>75%), consent (>90%), attrition (<5%); protocol adherence (>90%) and missing data (<5%). The primary clinical outcome was all-cause device failure. RESULTS: In total, 25 patients were recruited. The median patient age was 59-62 years; most patients were overweight/obese, with ≥2 co-morbidities. PRIMARY OUTCOMES: The eligibility and protocol adherence criteria were not met; of 159 screened patients, only 25 (16%) were eligible, and three patients did not receive their allocated intervention post-randomisation (88% adherence). All-cause failure occurred in two patients allocated to MC (20%) and one PICC (8.3%). CONCLUSIONS: Our study found that a fully powered RCT testing MCs compared with PICCs is not currently feasible in our setting. We recommend a robust process evaluation before the introduction of MCs into clinical practice.


Asunto(s)
Cateterismo Venoso Central , Catéteres Venosos Centrales , Humanos , Persona de Mediana Edad , Cateterismo Venoso Central/efectos adversos , Cateterismo Venoso Central/métodos , Proyectos Piloto , Catéteres Venosos Centrales/efectos adversos , Catéteres de Permanencia/efectos adversos , Pacientes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...