Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
J Pharm Pract ; 34(3): 465-471, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31615296

RESUMEN

OBJECTIVE: The objective of this study is to evaluate the prevalence and describe the patient care impact of student pharmacists completing community pharmacy rotations in medically underserved areas (MUAs) in Nebraska. METHODS: A list of pharmacy student advanced pharmacy practice experience placements over a 3-year period were obtained from 2 pharmacy schools in Nebraska and then mapped in relation to MUAs in the state. A mixed-methods approach was used to compare and relate findings of a student-logged patient care activity database and semistructured interviews with pharmacy preceptors of participating students. RESULTS: Pharmacy students were placed in 21 (13%) of 159 identified pharmacies located in MUAs. Pharmacy preceptors felt students improved the quality of patient care provided as a result of more uninterrupted time with the patient. Preceptors also indicated that student presence assists both the student and the practicing pharmacist engage in more patient care services. CONCLUSION: There exists a significant opportunity to utilize advanced pharmacy practice students to extend patient care services and address health-care needs in underserved communities, but student placement in MUAs should be optimized.


Asunto(s)
Educación en Farmacia , Farmacias , Estudiantes de Farmacia , Humanos , Área sin Atención Médica , Nebraska , Atención al Paciente , Farmacéuticos , Prevalencia
2.
Front Surg ; 7: 19, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32373625

RESUMEN

Cross-sectional MRI has modest diagnostic accuracy for diagnosing traumatic brachial plexus root avulsions. Consequently, patients either undergo major exploratory surgery or months of surveillance to determine if and what nerve reconstruction is needed. This study aimed to develop a diffusion tensor imaging (DTI) protocol at 3 Tesla to visualize normal roots and identify traumatic root avulsions of the brachial plexus. Seven healthy adults and 12 adults with known (operatively explored) unilateral traumatic brachial plexus root avulsions were scanned. DTI was acquired using a single-shot echo-planar imaging sequence at 3 Tesla. The brachial plexus was visualized by deterministic tractography. Fractional anisotropy (FA) and mean diffusivity (MD) were calculated for injured and avulsed roots in the lateral recesses of the vertebral foramen. Compared to healthy nerves roots, the FA of avulsed nerve roots was lower (mean difference 0.1 [95% CI 0.07, 0.13]; p < 0.001) and the MD was greater (mean difference 0.32 × 10-3 mm2/s [95% CI 0.11, 0.53]; p < 0.001). Deterministic tractography reconstructed both normal roots and root avulsions of the brachial plexus; the negative-predictive value for at least one root avulsion was 100% (95% CI 78, 100). Therefore, DTI might help visualize both normal and injured roots of the brachial plexus aided by tractography. The precision of this technique and how it relates to neural microstructure will be further investigated in a prospective diagnostic accuracy study of patients with acute brachial plexus injuries.

3.
Immunity ; 52(2): 357-373.e9, 2020 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-32049051

RESUMEN

Clearance of apoptotic cells by macrophages prevents excessive inflammation and supports immune tolerance. Here, we examined the effect of blocking apoptotic cell clearance on anti-tumor immune response. We generated an antibody that selectively inhibited efferocytosis by phagocytic receptor MerTK. Blockade of MerTK resulted in accumulation of apoptotic cells within tumors and triggered a type I interferon response. Treatment of tumor-bearing mice with anti-MerTK antibody stimulated T cell activation and synergized with anti-PD-1 or anti-PD-L1 therapy. The anti-tumor effect induced by anti-MerTK treatment was lost in Stinggt/gt mice, but not in Cgas-/- mice. Abolishing cGAMP production in Cgas-/- tumor cells, depletion of extracellular ATP, or inactivation of the ATP-gated P2X7R channel also compromised the effects of MerTK blockade. Mechanistically, extracellular ATP acted via P2X7R to enhance the transport of extracellular cGAMP into macrophages and subsequent STING activation. Thus, MerTK blockade increases tumor immunogenicity and potentiates anti-tumor immunity, which has implications for cancer immunotherapy.


Asunto(s)
Macrófagos/inmunología , Proteínas de la Membrana/metabolismo , Neoplasias/inmunología , Nucleótidos Cíclicos/metabolismo , Receptores Purinérgicos P2X7/metabolismo , Tirosina Quinasa c-Mer/inmunología , Adenosina Trifosfato/metabolismo , Animales , Apoptosis , Antígeno B7-H1/inmunología , Células Cultivadas , Femenino , Inmunidad Innata , Inmunoterapia , Interferón Tipo I/metabolismo , Macrófagos/metabolismo , Proteínas de la Membrana/genética , Ratones , Ratones Endogámicos C57BL , Ratones Mutantes , Neoplasias/metabolismo , Neoplasias/patología , Neoplasias/terapia , Nucleotidiltransferasas/deficiencia , Nucleotidiltransferasas/metabolismo , Fagocitosis , Receptor de Muerte Celular Programada 1/inmunología , Receptores Purinérgicos P2X7/deficiencia , Transducción de Señal/inmunología , Ensayos Antitumor por Modelo de Xenoinjerto , Tirosina Quinasa c-Mer/genética
4.
Invest Ophthalmol Vis Sci ; 60(13): 4097-4108, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31574535

RESUMEN

Purpose: Investigate a significant, dose-related increase in IOP, leading to glaucomatous damage to the neuroretina and optic nerve following intravitreal (ITV) administration of a bispecific F(ab')2 [anti-VEGF/Angiopoietins [ANGPT]F(ab')2] molecule in adult monkeys. Methods: ITV ocular tolerability and investigation of anti-VEGF/ANGPT F(ab')2 (blocking both ANGPT1 and ANGPT2) was done in monkeys; mechanistic studies were done in neonatal mice. Results: Following the second ITV dose of anti-VEGF/ANGPT F(ab')2, all 1.5- and 4-mg/eye treated monkeys developed elevated IOP, which eventually was associated with optic disc cupping and thinning of the neuroretinal rim. Histopathologic examination showed nonreversible axonal degeneration in the optic nerves of animals administered 1.5 mg/eye and higher that was considered secondary to high IOP. Anti-ANGPT Fab also caused elevated IOP in monkeys, but anti-VEGF Fab did not contribute to the IOP increase. In addition, an anti-ANGPT2-selective antibody did not change IOP. In mice simultaneous blockade of ANGPT1 and ANGPT2 impaired the expansion and formation of Schlemm's canal (SC) vessels, similar to genetic ablation of Angpt1/Angpt2 and their receptor TIE2. As previously reported, blocking ANGPT2 alone did not affect SC formation in mice. Conclusions: Dual inhibition of ANGPT1/ANGPT2, but not ANGPT2 alone, leads to increased IOP and glaucomatous damage in monkeys. This confirms a role for TIE2/ANGPT signaling in the control of IOP in adults, a finding initially identified in transgenic mice. Dual pharmacologic inhibition of ANGPT1/ANGPT2 may affect aqueous drainage and homeostasis in adult monkeys and may be useful in developing novel models of glaucoma.


Asunto(s)
Angiopoyetina 1/antagonistas & inhibidores , Angiopoyetina 2/antagonistas & inhibidores , Humor Acuoso/metabolismo , Glaucoma/fisiopatología , Transducción de Señal/fisiología , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Angiopoyetina 1/fisiología , Angiopoyetina 2/fisiología , Animales , Anticuerpos/farmacología , Presión Intraocular , Primates , Factor A de Crecimiento Endotelial Vascular/fisiología
5.
Radiology ; 293(1): 125-133, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31429680

RESUMEN

Background Traumatic brachial plexus injuries affect 1% of patients involved in major trauma. MRI is the best test for traumatic brachial plexus injuries, although its ability to differentiate root avulsions (which require urgent reconstructive surgery) from other types of nerve injury remains unknown. Purpose To evaluate the accuracy of MRI for diagnosing root avulsions in adults with traumatic brachial plexus injuries. Materials and Methods For this systematic review, MEDLINE and Embase were searched from inception to August 20, 2018. Studies of adults with traumatic nonpenetrating unilateral brachial plexus injuries were included. The target condition was root avulsion. The index test was preoperative MRI, and the reference standard was surgical exploration. A bivariate meta-analysis was used to estimate summary sensitivities and specificities of MRI for avulsion. Results Eleven studies of 275 adults (mean age, 27 years; 229 men) performed between 1992 and 2016 were included. Most participants had been injured in motorcycle collisions (84%). All studies were at risk of bias, and there were high applicability concerns for the index test (ie, MRI) in four studies given the lack of diagnostic criteria, inadequate descriptions of pulse sequences, and multiplicity of reporting radiologists. Overall, 72% of patients with brachial plexus injuries had at least one root avulsion (interquartile range [IQR]: 53%-86%); meta-analysis of patient-level data was not performed because of sparse and heterogeneous data. With the nerve root as the unit of analysis, 583 of 918 roots were avulsed (median, 55%; IQR: 38%-71%); the mean sensitivity of MRI for root avulsion was 93% (95% confidence interval [CI]: 77%, 98%) with a mean specificity of 72% (95% CI: 42%, 90%). Conclusion On the basis of limited data, MRI offers modest diagnostic accuracy for traumatic brachial plexus root avulsion(s), and early surgical exploration should remain as the preferred method of diagnosis. Published under a CC BY 4.0 license. Online supplemental material is available for this article.


Asunto(s)
Plexo Braquial/diagnóstico por imagen , Plexo Braquial/lesiones , Imagen por Resonancia Magnética/métodos , Polirradiculoneuropatía/diagnóstico por imagen , Humanos , Sensibilidad y Especificidad , Raíces Nerviosas Espinales/diagnóstico por imagen , Raíces Nerviosas Espinales/lesiones
6.
Br J Radiol ; 92(1101): 20190143, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31298948

RESUMEN

OBJECTIVES: To assess the test-retest variability of both diffusion parameters and fat fraction (FF) estimates in normal muscle, and to assess differences in normal values between muscles in the thigh. METHODS: 29 healthy volunteers (mean age 37 years, range 20-60 years, 17/29 males) completed the study. Magnetic resonance images of the mid-thigh were acquired using a stimulated echo acquisition mode-echoplanar imaging (STEAM-EPI) imaging sequence, to assess diffusion, and 2-point Dixon imaging, to assess FF. Imaging was repeated in 19 participants after a 30 min interval in order to assess test-retest variability of the measurements. RESULTS: Intraclass correlation coefficients (ICCs) for test-retest variability were 0.99 [95% confidence interval, (CI): 0.98, 1] for FF, 0.94 (95% CI: 0.84, 0.97) for mean diffusivity and 0.89 (95% CI: 0.74, 0.96) for fractional anisotropy (FA). FF was higher in the hamstrings than the quadriceps by a mean difference of 1.81% (95% CI:1.63, 2.00)%, p < 0.001. Mean diffusivity was significantly lower in the hamstrings than the quadriceps (0.26 (0.13, 0.39) x10-3 mm2s-1, p < 0.001) whereas fractional anisotropy was significantly higher in the hamstrings relative to the quadriceps with a mean difference of 0.063 (0.05, 0.07), p < 0.001. CONCLUSIONS: This study has shown excellent test-retest, variability in MR-based FF and diffusion measurements and demonstrated significant differences in these measures between hamstrings and quadriceps in the healthy thigh. ADVANCES IN KNOWLEDGE: Test-retest variability is excellent for STEAM-EPI diffusion and 2-point Dixon-based FF measurements in the healthy muscle. Inter- and intraobserver variability were excellent for region of interest placement for STEAM-EPI diffusion and 2-point Dixon-based FF measurements in the healthy muscle. There are significant differences in FF and diffusion measurements between the hamstrings and quadriceps in the normal muscle.


Asunto(s)
Imagen de Difusión Tensora/métodos , Músculo Esquelético/anatomía & histología , Adulto , Imagen Eco-Planar/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Valores de Referencia , Reproducibilidad de los Resultados , Muslo/anatomía & histología , Adulto Joven
7.
Spine (Phila Pa 1976) ; 44(11): 793-800, 2019 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-31095529

RESUMEN

STUDY DESIGN: An in vitro magnetic resonance imaging (MRI) study. OBJECTIVE: Investigate the potential of high-field MRI for producing higher quality images of the intervertebral disc (IVD) to better distinguish structural details. SUMMARY OF BACKGROUND DATA: Higher spatial and contrast resolution are important advantages when imaging the complex tissue structures in the spine such as the IVDs. However, at present it is challenging to capture the substructural details in the IVD such as the lamellae. METHODS: Three MRI sequences; two-dimensional proton-density-weighted Turbo-Spin-Echo (PD-TSE), 2D T2-weighted Turbo-Spin-Echo (T2W-TSE) with fat-saturation (FS), and 3D Spoiled-Gradient-Echo (3D-GE), were modified based on the image quality and scan duration. IVDs of three intact cadaveric lumbar-spines (T12-S1, Age 83-94 yr) were imaged using these optimized sequences. Thereafter each IVD was transversely sectioned and the exposed surfaces were photographed. Landmark observations from corresponding MRI slices and photographs were compared to confirm the MRI captured morphology. The image quality was evaluated using signal-to-noise ratio (SNR), and relative-contrast values. Finally, the underlying tissue structures, including specific pathological features, were qualitatively compared between the MR images and photographs. RESULTS: Observations from photographs and corresponding MRI slices matched well. The PD-TSE sequence had better overall SNR, but the relative contrast between the tissue types was relatively poor. The 3D-GE sequence had higher relative contrast between the IVD and bone, but not between annulus and nucleus regions. The T2W images provided the best relative contrast between the annulus and nucleus, however the standard deviations here were high. Structural details including fissures, vascular and granular tissue proliferation, and pathologies in the endplate region, were identifiable from the MR images obtained using the optimized sequences. CONCLUSION: The results demonstrate the potential of high-field MRI to capture the IVD structural details. Since the acquisition durations were within clinically acceptable levels, these methodological improvements have the potential to enhance clinical diagnostics. LEVEL OF EVIDENCE: 4.


Asunto(s)
Imagenología Tridimensional/métodos , Disco Intervertebral/diagnóstico por imagen , Vértebras Lumbares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Femenino , Humanos , Disco Intervertebral/patología , Vértebras Lumbares/patología , Masculino , Persona de Mediana Edad , Relación Señal-Ruido
8.
Syst Rev ; 7(1): 76, 2018 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-29778092

RESUMEN

BACKGROUND: Adult brachial plexus injuries (BPI) are becoming more common. The reconstruction and prognosis of pre-ganglionic injuries (root avulsions) are different to other types of BPI injury. Preoperative magnetic resonance imaging (MRI) is being used to identify root avulsions, but the evidence from studies of its diagnostic accuracy are conflicting. Therefore, a systematic review is needed to address uncertainty about the accuracy of MRI and to guide future research. METHODS: We will conduct a systematic search of electronic databases alongside reference tracking. We will include studies of adults with traumatic BPI which report the accuracy of preoperative MRI (index test) against surgical exploration of the roots of the brachial plexus (reference standard) for detecting either of the two target conditions (any root avulsion or any pseudomeningocoele as a surrogate marker of root avulsion). We will exclude case reports, articles considering bilateral injuries and studies where the number of true positives, false positives, false negatives and true negatives cannot be derived. The methodological quality of the included studies will be assessed using a tailored version of the QUADAS-2 tool. Where possible, a bivariate model will be used for meta-analysis to obtain summary sensitivities and specificities for both target conditions. We will investigate heterogeneity in the performance of MRI according to field strength and the risk of bias if data permits. DISCUSSION: This review will summarise the current diagnostic accuracy of MRI for adult BPI, identify shortcomings and gaps in the literature and so help to guide future research. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42016049702 .


Asunto(s)
Plexo Braquial/diagnóstico por imagen , Plexo Braquial/lesiones , Imagen por Resonancia Magnética/métodos , Valor Predictivo de las Pruebas , Adulto , Humanos , Evaluación de Resultado en la Atención de Salud , Sensibilidad y Especificidad
9.
J Hand Surg Eur Vol ; 43(3): 250-258, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28886666

RESUMEN

Identification of root avulsions is of critical importance in traumatic brachial plexus injuries because it alters the reconstruction and prognosis. Pre-operative magnetic resonance imaging is gaining popularity, but there is limited and conflicting data on its diagnostic accuracy for root avulsion. This cohort study describes consecutive patients requiring brachial plexus exploration following trauma between 2008 and 2016. The index test was magnetic resonance imaging at 1.5 Tesla and the reference test was operative exploration of the supraclavicular plexus. Complete data from 29 males was available. The diagnostic accuracy of magnetic resonance imaging for root avulsion(s) of C5-T1 was 79%. The diagnostic accuracy of a pseudomeningocoele as a surrogate marker of root avulsion(s) of C5-T1 was 68%. We conclude that pseudomeningocoles were not a reliable sign of root avulsion and magnetic resonance imaging has modest diagnostic accuracy for root avulsions in the context of adult traumatic brachial plexus injuries. LEVEL OF EVIDENCE: III.


Asunto(s)
Plexo Braquial/diagnóstico por imagen , Plexo Braquial/lesiones , Imagen por Resonancia Magnética/métodos , Radiculopatía/diagnóstico por imagen , Adulto , Plexo Braquial/cirugía , Diagnóstico Diferencial , Humanos , Masculino , Radiculopatía/cirugía , Estudios Retrospectivos , Sensibilidad y Especificidad
10.
J Clin Nurs ; 25(9-10): 1179-92, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26990364

RESUMEN

AIMS AND OBJECTIVES: The purpose of this scoping review of literature is to explore the types of computer-based systems used for self-management of chronic disease, the goals and success of these systems, the value added by technology integration and the target audience for these systems. BACKGROUND: Technology is changing the way health care is provided and the way that individuals manage their health. Individuals with chronic diseases are now able to use computer-based systems to self-manage their health. These systems have the ability to remind users of daily activities, and to help them recognise when symptoms are worsening and intervention is indicated. However, there are many questions about the types of systems available, the goals of these systems and the success with which individuals with chronic illness are using them. DESIGN: This is a scoping review in which the Cumulative Index of Nursing and Allied Health Literature, PubMed and IEEE Xplore databases were searched. A total of 303 articles were reviewed, 89 articles were read in-depth and 30 were included in the scoping review. The Substitution, Augmentation, Modification, Redefinition model was used to evaluate the value added by the technology integration. FINDINGS: Research on technology for self-management was conducted in 13 countries. Data analysis identified five kinds of platforms on which the systems were based, some systems were focused on a specific disease management processes, others were not. CONCLUSIONS: For individuals to effectively use systems to maintain maximum wellness, the systems must have a strong component of self-management and provide the user with meaningful information regarding their health states. RELEVANCE TO CLINICAL PRACTICE: Clinicians should choose systems for their clients based on the design, components and goals of the systems.


Asunto(s)
Enfermedad Crónica/terapia , Autocuidado , Programas Informáticos , Enfermedad Crónica/enfermería , Atención a la Salud , Humanos , Informática Médica , Evaluación de Resultado en la Atención de Salud
11.
Clin Cancer Res ; 22(6): 1469-79, 2016 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-26589434

RESUMEN

PURPOSE: Although agents targeting Delta-like ligand 4 (DLL4) have shown great promise for angiogenesis-based cancer therapy, findings in recent studies have raised serious safety concerns. To further evaluate the potential for therapeutic targeting of the DLL4 pathway, we pursued a novel strategy to reduce toxicities related to DLL4 inhibition by modulating the pharmacokinetic (PK) properties of an anti-DLL4 antibody. EXPERIMENTAL DESIGN: The F(ab')2 fragment of anti-DLL4 antibody (anti-DLL4 F(ab')2) was generated and assessed in efficacy and toxicity studies. RESULTS: Anti-DLL4 F(ab')2 enables greater control over the extent and duration of DLL4 inhibition, such that intermittent dosing of anti-DLL4 F(ab')2 can maintain significant antitumor activity while markedly mitigating known toxicities associated with continuous pathway inhibition. CONCLUSIONS: PK modulation has potentially broad implications for development of antibody-based therapeutics. Our safety studies with anti-DLL4 F(ab')2 also provide new evidence reinforcing the notion that the DLL4 pathway is extremely sensitive to pharmacologic perturbation, further underscoring the importance of exercising caution to safely harness this potent pathway in humans.


Asunto(s)
Inhibidores de la Angiogénesis/farmacología , Anticuerpos Monoclonales/farmacología , Antineoplásicos/farmacología , Péptidos y Proteínas de Señalización Intracelular/antagonistas & inhibidores , Proteínas de la Membrana/antagonistas & inhibidores , Inhibidores de la Angiogénesis/efectos adversos , Inhibidores de la Angiogénesis/farmacocinética , Animales , Anticuerpos Monoclonales/efectos adversos , Anticuerpos Monoclonales/farmacocinética , Antineoplásicos/efectos adversos , Antineoplásicos/farmacocinética , Línea Celular Tumoral , Modelos Animales de Enfermedad , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Fragmentos Fab de Inmunoglobulinas , Hígado/efectos de los fármacos , Hígado/metabolismo , Hígado/patología , Macaca fascicularis , Ratones , Ratas , Carga Tumoral/efectos de los fármacos , Ensayos Antitumor por Modelo de Xenoinjerto
12.
Spine (Phila Pa 1976) ; 40(24): E1315-22, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26244404

RESUMEN

STUDY DESIGN: An in vitro study of the intervertebral disc (IVD) structure using 9.4T magnetic resonance imaging (MRI). OBJECTIVE: Investigate the potential of ultrahigh-field strength MRI for higher quality 3-dimensional (3D) volumetric MRI datasets of the IVD to better distinguish structural details. SUMMARY OF BACKGROUND DATA: MRI has the advantages of being nondestructive and 3D in comparison to most techniques used to obtain the structural details of biological tissues, however, its poor image quality at higher resolution is a limiting factor. Ultrahigh-field MRI could improve the imaging of biological tissues but the current understanding of its application for spinal tissue is limited. METHODS: 2 ovine spinal segments (C7-T1, T2-T3) containing the IVD were separately imaged using 2 sequences; 3D spin echo (multislice-multiecho) pulse sequence for the C7-T1 sample and 3D gradient echo (fast-low-angle-shot) pulse sequence for the T2-T3 sample. The C7-T1 sample was subsequently decalcified and imaged again using the same scanning parameters. Histological sections obtained from the decalcified sample were stained followed by digital scanning. Observations from corresponding MRI slices and histological sections were compared as a method of confirmation of morphology captured under MRI. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative-contrast values were calculated for quantitative evaluation of image quality. RESULTS: Measurements from histology sections and corresponding MRI slices matched well. Both sequences revealed finer details of the IVD structure. Under the spin echo sequence, the annulus lamellae architecture was distinguishable and the SNR and CNR values were higher. The relative contrast was considerably higher between high (nucleus) and low (bone) signal constituents, but between the nucleus and the annulus the relative contrast was low. Under the gradient echo sequence, although the relative contrasts between constituents were poor, the fiber orientation was clearly manifested. CONCLUSION: The obtained positive results demonstrate the potential of ultrahigh-field strength MRI to nondestructively capture the IVD structure. LEVEL OF EVIDENCE: N/A.


Asunto(s)
Disco Intervertebral/anatomía & histología , Imagen por Resonancia Magnética/métodos , Animales , Procesamiento de Imagen Asistido por Computador , Ovinos , Relación Señal-Ruido
13.
Proc Natl Acad Sci U S A ; 110(29): 11887-92, 2013 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-23812757

RESUMEN

Many important signaling pathways rely on multiple ligands. It is unclear if this is a mechanism of safeguard via redundancy or if it serves other functional purposes. In this study, we report unique insight into this question by studying the activin receptor-like kinase 1 (ALK1) pathway. Despite its functional importance in vascular development, the physiological ligand or ligands for ALK1 remain to be determined. Using conventional knockout and specific antibodies against bone morphogenetic protein 9 (BMP9) or BMP10, we showed that BMP9 and BMP10 are the physiological, functionally equivalent ligands of ALK1 in vascular development. Timing of expression dictates the in vivo requisite role of each ligand, and concurrent expression results in redundancy. We generated mice (Bmp10(9/9)) in which the coding sequence of Bmp9 replaces that of Bmp10. Surprisingly, analysis of Bmp10(9/9) mice demonstrated that BMP10 has an exclusive function in cardiac development, which cannot be substituted by BMP9. Our study reveals context-dependent significance in having multiple ligands in a signaling pathway.


Asunto(s)
Receptores de Activinas Tipo I/metabolismo , Proteínas Morfogenéticas Óseas/metabolismo , Sistema Cardiovascular/embriología , Sistema Cardiovascular/crecimiento & desarrollo , Factor 2 de Diferenciación de Crecimiento/metabolismo , Transducción de Señal/fisiología , Receptores de Activinas Tipo II , Animales , Anticuerpos Neutralizantes , Proteínas Morfogenéticas Óseas/genética , Sistema Cardiovascular/metabolismo , Técnicas de Sustitución del Gen , Factor 2 de Diferenciación de Crecimiento/genética , Células Endoteliales de la Vena Umbilical Humana , Humanos , Hibridación in Situ , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Ratones Transgénicos , Microscopía Fluorescente , Vasos Retinianos/crecimiento & desarrollo , Vasos Retinianos/metabolismo
14.
Semin Musculoskelet Radiol ; 16(5): 367-76, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23212872

RESUMEN

MRI is increasingly used for the assessment of both inflammatory arthritis and osteoarthritis. The wide variety of MRI systems in use ranges from low-field, low-cost extremity units to whole-body high-field 7-T systems, each with different strengths for specific applications. The availability of dedicated radiofrequency phased-array coils allows the rapid acquisition of high-resolution images of one or more peripheral joints. MRI is uniquely flexible in its ability to manipulate image contrast, and individual MR sequences may be combined into protocols to sensitively visualize multiple features of arthritis including synovitis, bone marrow lesions, erosions, cartilage changes, and tendinopathy. Careful choice of the imaging parameters allows images to be generated with optimal quality while minimizing unwanted artifacts. Finally, there are many novel MRI techniques that can quantify disease levels in arthritis in tissues including synovitis and cartilage.


Asunto(s)
Artritis Reumatoide/diagnóstico , Imagen por Resonancia Magnética/métodos , Osteoartritis/diagnóstico , Artefactos , Médula Ósea/patología , Cartílago Articular/metabolismo , Cartílago Articular/patología , Humanos , Sinovitis/diagnóstico , Tendones/patología
15.
J Cardiovasc Magn Reson ; 14: 66, 2012 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-22995744

RESUMEN

This is the second of two reviews that is intended to cover the essential aspects of cardiovascular magnetic resonance (CMR) physics in a way that is understandable and relevant to clinicians using CMR in their daily practice. Starting with the basic pulse sequences and contrast mechanisms described in part I, it briefly discusses further approaches to accelerate image acquisition. It then continues by showing in detail how the contrast behaviour of black blood fast spin echo and bright blood cine gradient echo techniques can be modified by adding rf preparation pulses to derive a number of more specialised pulse sequences. The simplest examples described include T2-weighted oedema imaging, fat suppression and myocardial tagging cine pulse sequences. Two further important derivatives of the gradient echo pulse sequence, obtained by adding preparation pulses, are used in combination with the administration of a gadolinium-based contrast agent for myocardial perfusion imaging and the assessment of myocardial tissue viability using a late gadolinium enhancement (LGE) technique. These two imaging techniques are discussed in more detail, outlining the basic principles of each pulse sequence, the practical steps required to achieve the best results in a clinical setting and, in the case of perfusion, explaining some of the factors that influence current approaches to perfusion image analysis. The key principles of contrast-enhanced magnetic resonance angiography (CE-MRA) are also explained in detail, especially focusing on timing of the acquisition following contrast agent bolus administration, and current approaches to achieving time resolved MRA. Alternative MRA techniques that do not require the use of an endogenous contrast agent are summarised, and the specialised pulse sequence used to image the coronary arteries, using respiratory navigator gating, is described in detail. The article concludes by explaining the principle behind phase contrast imaging techniques which create images that represent the phase of the MR signal rather than the magnitude. It is shown how this principle can be used to generate velocity maps by designing gradient waveforms that give rise to a relative phase change that is proportional to velocity. Choice of velocity encoding range and key pitfalls in the use of this technique are discussed.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión Miocárdica/métodos , Artefactos , Enfermedades Cardiovasculares/fisiopatología , Medios de Contraste , Circulación Coronaria , Humanos , Angiografía por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Valor Predictivo de las Pruebas , Pronóstico , Mecánica Respiratoria
16.
J Cardiovasc Magn Reson ; 14: 22, 2012 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-22455461

RESUMEN

BACKGROUND: The short inversion time inversion recovery (STIR) black-blood technique has been used to visualize myocardial edema, and thus to differentiate acute from chronic myocardial lesions. However, some cardiovascular magnetic resonance (CMR) groups have reported variable image quality, and hence the diagnostic value of STIR in routine clinical practice has been put into question. The aim of our study was to analyze image quality and diagnostic performance of STIR using a set of pulse sequence parameters dedicated to edema detection, and to discuss possible factors that influence image quality. We hypothesized that STIR imaging is an accurate and robust way of detecting myocardial edema in non-selected patients with acute myocardial infarction. METHODS: Forty-six consecutive patients with acute myocardial infarction underwent CMR (day 4.5, +/- 1.6) including STIR for the assessment of myocardial edema and late gadolinium enhancement (LGE) for quantification of myocardial necrosis. Thirty of these patients underwent a follow-up CMR at approximately six months (195 +/- 39 days). Both STIR and LGE images were evaluated separately on a segmental basis for image quality as well as for presence and extent of myocardial hyper-intensity, with both visual and semi-quantitative (threshold-based) analysis. LGE was used as a reference standard for localization and extent of myocardial necrosis (acute) or scar (chronic). RESULTS: Image quality of STIR images was rated as diagnostic in 99.5% of cases. At the acute stage, the sensitivity and specificity of STIR to detect infarcted segments on visual assessment was 95% and 78% respectively, and on semi-quantitative assessment was 99% and 83%, respectively. STIR differentiated acutely from chronically infarcted segments with a sensitivity of 95% by both methods and with a specificity of 99% by visual assessment and 97% by semi-quantitative assessment. The extent of hyper-intense areas on acute STIR images was 85% larger than those on LGE images, with a larger myocardial salvage index in reperfused than in non-reperfused infarcts (p = 0.035). CONCLUSIONS: STIR with appropriate pulse sequence settings is accurate in detecting acute myocardial infarction (MI) and distinguishing acute from chronic MI with both visual and semi-quantitative analysis. Due to its unique technical characteristics, STIR should be regarded as an edema-weighted rather than a purely T2-weighted technique.


Asunto(s)
Cardiomiopatías/diagnóstico , Edema/diagnóstico , Aumento de la Imagen/métodos , Imagen por Resonancia Cinemagnética/métodos , Miocardio/patología , Diagnóstico Diferencial , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Tiempo
17.
Lancet ; 379(9814): 453-60, 2012 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-22196944

RESUMEN

BACKGROUND: In patients with suspected coronary heart disease, single-photon emission computed tomography (SPECT) is the most widely used test for the assessment of myocardial ischaemia, but its diagnostic accuracy is reported to be variable and it exposes patients to ionising radiation. The aim of this study was to establish the diagnostic accuracy of a multiparametric cardiovascular magnetic resonance (CMR) protocol with x-ray coronary angiography as the reference standard, and to compare CMR with SPECT, in patients with suspected coronary heart disease. METHODS: In this prospective trial patients with suspected angina pectoris and at least one cardiovascular risk factor were scheduled for CMR, SPECT, and invasive x-ray coronary angiography. CMR consisted of rest and adenosine stress perfusion, cine imaging, late gadolinium enhancement, and MR coronary angiography. Gated adenosine stress and rest SPECT used (99m)Tc tetrofosmin. The primary outcome was diagnostic accuracy of CMR. This trial is registered at controlled-trials.com, number ISRCTN77246133. FINDINGS: In the 752 recruited patients, 39% had significant CHD as identified by x-ray angiography. For multiparametric CMR the sensitivity was 86·5% (95% CI 81·8-90·1), specificity 83·4% (79·5-86·7), positive predictive value 77·2%, (72·1-81·6) and negative predictive value 90·5% (87·1-93·0). The sensitivity of SPECT was 66·5% (95% CI 60·4-72·1), specificity 82·6% (78·5-86·1), positive predictive value 71·4% (65·3-76·9), and negative predictive value 79·1% (74·8-82·8). The sensitivity and negative predictive value of CMR and SPECT differed significantly (p<0·0001 for both) but specificity and positive predictive value did not (p=0·916 and p=0·061, respectively). INTERPRETATION: CE-MARC is the largest, prospective, real world evaluation of CMR and has established CMR's high diagnostic accuracy in coronary heart disease and CMR's superiority over SPECT. It should be adopted more widely than at present for the investigation of coronary heart disease. FUNDING: British Heart Foundation.


Asunto(s)
Enfermedad Coronaria/diagnóstico , Angiografía por Resonancia Magnética , Imagen de Perfusión Miocárdica , Tomografía Computarizada de Emisión de Fotón Único , Adenosina , Medios de Contraste , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Gadolinio DTPA , Humanos , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
18.
Blood ; 118(7): 1989-97, 2011 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-21700774

RESUMEN

The Notch signaling pathway plays a fundamental role during blood vessel development. Notch signaling regulates blood vessel morphogenesis by promoting arterial endothelial differentiation and providing spatial and temporal control over "tip cell" phenotype during angiogenic sprouting. Components of the Notch signaling pathway have emerged as potential regulators of lymphatic development, joining the increasing examples of blood vessel regulators that are also involved in lymphatic development. However, in mammals a role for the Notch signaling pathway during lymphatic development remains to be demonstrated. In this report, we show that blockade of Notch1 and Dll4, with specific function-blocking antibodies, results in defective postnatal lymphatic development in mice. Mechanistically, Notch1-Dll4 blockade is associated with down-regulation of EphrinB2 expression, been shown to be critically involved in VEGFR3/VEGFC signaling, resulting in reduced lymphangiogenic sprouting. In addition, Notch1-Dll4 blockade leads to compromised expression of distinct lymphatic markers and to dilation of collecting lymphatic vessels with reduced and disorganized mural cell coverage. Finally, Dll4-blockade impairs wound closure and severely affects lymphangiogenesis during the wound healing in adult mouse skin. Thus, our study demonstrates for the first time in a mammalian system that Notch1-Dll4 signaling pathway regulates postnatal lymphatic development and pathologic lymphangiogenesis.


Asunto(s)
Péptidos y Proteínas de Señalización Intracelular/metabolismo , Linfangiogénesis , Vasos Linfáticos/metabolismo , Proteínas de la Membrana/metabolismo , Receptor Notch1/metabolismo , Transducción de Señal , Proteínas Adaptadoras Transductoras de Señales , Animales , Proteínas de Unión al Calcio , Línea Celular , Efrina-B2/genética , Regulación del Desarrollo de la Expresión Génica , Humanos , Vasos Linfáticos/citología , Vasos Linfáticos/ultraestructura , Ratones
19.
J Cardiovasc Magn Reson ; 12: 71, 2010 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-21118531

RESUMEN

There are many excellent specialised texts and articles that describe the physical principles of cardiovascular magnetic resonance (CMR) techniques. There are also many texts written with the clinician in mind that provide an understandable, more general introduction to the basic physical principles of magnetic resonance (MR) techniques and applications. There are however very few texts or articles that attempt to provide a basic MR physics introduction that is tailored for clinicians using CMR in their daily practice. This is the first of two reviews that are intended to cover the essential aspects of CMR physics in a way that is understandable and relevant to this group. It begins by explaining the basic physical principles of MR, including a description of the main components of an MR imaging system and the three types of magnetic field that they generate. The origin and method of production of the MR signal in biological systems are explained, focusing in particular on the two tissue magnetisation relaxation properties (T1 and T2) that give rise to signal differences from tissues, showing how they can be exploited to generate image contrast for tissue characterisation. The method most commonly used to localise and encode MR signal echoes to form a cross sectional image is described, introducing the concept of k-space and showing how the MR signal data stored within it relates to properties within the reconstructed image. Before describing the CMR acquisition methods in detail, the basic spin echo and gradient pulse sequences are introduced, identifying the key parameters that influence image contrast, including appearances in the presence of flowing blood, resolution and image acquisition time. The main derivatives of these two pulse sequences used for cardiac imaging are then described in more detail. Two of the key requirements for CMR are the need for data acquisition first to be to be synchronised with the subject's ECG and to be fast enough for the subject to be able to hold their breath. Methods of ECG synchronisation using both triggering and retrospective gating approaches, and accelerated data acquisition using turbo or fast spin echo and gradient echo pulse sequences are therefore outlined in some detail. It is shown how double inversion black blood preparation combined with turbo or fast spin echo pulse sequences acquisition is used to achieve high quality anatomical imaging. For functional cardiac imaging using cine gradient echo pulse sequences two derivatives of the gradient echo pulse sequence; spoiled gradient echo and balanced steady state free precession (bSSFP) are compared. In each case key relevant imaging parameters and vendor-specific terms are defined and explained.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas , Enfermedades Cardiovasculares/diagnóstico , Imagen por Resonancia Magnética , Técnicas de Imagen Sincronizada Cardíacas/instrumentación , Electrocardiografía , Diseño de Equipo , Frecuencia Cardíaca , Humanos , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Cinemagnética , Valor Predictivo de las Pruebas , Pronóstico , Mecánica Respiratoria
20.
Magn Reson Med ; 64(6): 1696-703, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20928890

RESUMEN

Myocardial blood flow varies during the cardiac cycle in response to pulsatile changes in epicardial circulation and cyclical variation in myocardial tension. First-pass assessment of myocardial perfusion by dynamic contrast-enhanced MRI is one of the most challenging applications of MRI because of the spatial and temporal constraints imposed by the cardiac physiology and the nature of dynamic contrast-enhanced MRI signal collection. Here, we describe a dynamic contrast-enhanced MRI method for simultaneous assessment of systolic and diastolic myocardial blood flow. The feasibility of this method was demonstrated in a study of 17 healthy volunteers at rest and under adenosine-induced vasodilatory stress. We found that myocardial blood flow was independent of the cardiac phase at rest. However, under adenosine-induced hyperemia, myocardial blood flow and myocardial perfusion reserve were significantly higher in diastole than in systole. Furthermore, the transmural distribution of myocardial blood flow and myocardial perfusion reserve was cardiac phase dependent, with a reversal of the typical subendocardial to subepicardial myocardial blood flow gradient in systole, but not diastole, under stress. The observed difference between systolic and diastolic myocardial blood flow must be taken into account when assessing myocardial blood flow using dynamic contrast-enhanced MRI. Furthermore, targeted assessment of systolic or diastolic perfusion using dynamic contrast-enhanced MRI may provide novel insights into the pathophysiology of ischemic and microvascular heart disease.


Asunto(s)
Circulación Coronaria/fisiología , Diástole/fisiología , Imagen por Resonancia Cinemagnética/métodos , Sístole/fisiología , Adulto , Medios de Contraste/administración & dosificación , Femenino , Gadolinio DTPA/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA