Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-36377541

RESUMEN

BACKGROUND AND OBJECTIVES: Clinical heterogeneity in sensitizer-induced occupational asthma (OA) and its relationship to airway inflammatory profiles remain poorly elucidated. To further characterize the interactions between induced sputum inflammatory patterns, asthma-related outcomes and the high- or low-molecular-weight category of causal agents in a large cohort of subjects with OA. METHODS: This multicenter, retrospective, cross-sectional study was conducted among 296 subjects with OA ascertained by a positive specific inhalation challenge who completed induced sputum assessment before and 24 hours after challenge exposure. RESULTS: Multivariate logistic regression analysis revealed that sputum eosinophilia ≥3% was significantly associated with a high dose of inhaled corticosteroid (odds ratio [95% confidence interval], 1.31 [1.11-1.55] for each 250-µg increment in daily dose), short-acting b2-agonist use less than once a day (3.54 [1.82-7.00]), and the level of baseline nonspecific bronchial hyperresponsiveness (mild: 2.48 [1.21-5.08]); moderate/severe: 3.40 [1.44-8.29]). Sputum neutrophilia ≥76% was associated with age (1.06 [1.01-1.11]), male gender (3.34 [1.29-9.99]), absence of corticosteroid use (5.47 [2.09-15.16]), short-acting b2-agonist use once or more a day (4.09 [1.71-10.01]), ≥2 severe exacerbations during the last 12 months at work (4.22 [1.14-14.99]), and isolated early reactions during the SIC (4.45 [1.85-11.59]). CONCLUSIONS: The findings indicate that sputum inflammatory patterns in subjects with OA are associated with distinct phenotypic characteristics and further highlight the differential effects of neutrophils and eosinophils on asthma-related outcomes. These associations between inflammatory patterns and clinical characteristics share broad similarities with what has been reported in nonoccupational asthma and are not related to the type of causal agent.

2.
Allergy ; 73(1): 206-213, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28771844

RESUMEN

BACKGROUND: Ascertaining the presence of asthma through the assessment of nonspecific bronchial hyperresponsiveness (NSBH) is a key step in the diagnosis of occupational asthma (OA). We aimed at investigating whether indices of airway inflammation including fractional exhaled nitric oxide (FeNO) and sputum eosinophils would be useful adjuncts to the measurement of NSBH in diagnosing OA defined as a positive specific inhalation challenge (SIC). METHODS: The study included 240 consecutive subjects with a suspicion of OA who completed a SIC, of whom 133 showed a positive response. The sensitivity, specificity, and predictive values of NSBH, and FeNO, as well as sputum eosinophil counts assessed at baseline of the SIC were determined. RESULTS: A concentration of histamine inducing a 20% decline in FEV1 (PC20 ) ≤16 mg/mL showed a sensitivity of 87% and a specificity of 36%. A FeNO level ≥25 ppb and a sputum eosinophil count ≥2% provided lower sensitivity rates (47% and 39%, respectively) than the PC20 value. Eight of the 17 subjects without baseline NSBH despite a positive SIC showed a sputum eosinophil count ≥2%, a FeNO level ≥25 ppb, or both outcomes. Combining either a PC20 value ≤16 mg/mL or a FeNO ≥25 ppb increased the sensitivity to 91%. Using either a PC20 ≤16 mg/mL or a sputum eosinophil count ≥1% increased the sensitivity to 94%. CONCLUSION: Adding the assessment of FeNO level and sputum eosinophils to NSBH improves the identification of subjects who may have OA and require further objective testing before excluding the possibility of OA.


Asunto(s)
Asma Ocupacional/diagnóstico , Eosinófilos/inmunología , Anciano , Asma Ocupacional/inmunología , Asma Ocupacional/metabolismo , Asma Ocupacional/patología , Hiperreactividad Bronquial/diagnóstico , Pruebas de Provocación Bronquial , Eosinofilia , Eosinófilos/metabolismo , Eosinófilos/patología , Espiración , Femenino , Humanos , Recuento de Leucocitos , Masculino , Óxido Nítrico , Estudios Prospectivos , Sensibilidad y Especificidad , Esputo/química , Evaluación de Síntomas
3.
Occup Med (Lond) ; 67(9): 722-724, 2017 12 30.
Artículo en Inglés | MEDLINE | ID: mdl-29040709

RESUMEN

We describe a 43-year-old epoxy floor layer who developed work-related asthma while exposed to an epoxy hardener based on isophorone diamine (IPDA). Challenge exposures to the curing of the epoxy resin system and subsequently to the polyfunctional amine hardener containing IPDA both elicited delayed asthmatic reactions. This report further indicates that exposure to epoxy hardeners containing polyfunctional amines should be considered as a potential cause of occupational asthma. Appropriate work hygiene measures should be implemented to minimize airborne exposure to these volatile compounds.


Asunto(s)
Asma Ocupacional/etiología , Compuestos Epoxi/efectos adversos , Adulto , Asma Ocupacional/fisiopatología , Dermatitis Profesional/etiología , Dermatitis Profesional/fisiopatología , Humanos , Masculino , Exposición Profesional/efectos adversos
4.
Allergy ; 71(6): 840-9, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26940537

RESUMEN

BACKGROUND: Recombinant Hevea brasiliensis (rHev b) natural rubber latex (NRL) allergen components have been developed to assess the patients' allergen sensitization profile and to improve the diagnosis of NRL allergy. OBJECTIVE: To examine whether the determination of specific IgE (sIgE) reactivity to a panel of recombinant allergen components would be helpful for diagnosing NRL-induced occupational asthma (OA) in predicting the outcome of a specific inhalation test. METHODS: sIgE levels to NRL extract and 12 recombinant NRL allergen components were assessed in 82 subjects with OA ascertained by a positive specific inhalation challenge (SIC) with NRL gloves and in 25 symptomatic subjects with a negative challenge. RESULTS: The sensitivity, specificity, positive predictive value, and negative predictive value of a NRL-sIgE level ≥0.35 kUA /l as compared to the result of SICs were 94%, 48%, 86%, and 71%, respectively. The positive predictive value increased above 95% when increasing the cutoff value to 5.41 kUA /l. Subjects with a positive SIC showed a significantly higher rate of sIgE reactivity to rHev b 5, 6.01, 6.02, and 11 than those with a negative SIC. A sIgE sum score against rHev b 5 plus 6.01/6.02 ≥ 1.46 kUA /l provided a positive predictive value >95% with a higher sensitivity (79%) and diagnostic efficiency (Youden index: 0.67) as compared with a NRL-sIgE ≥5.41 kUA /l (49% and 0.41, respectively). CONCLUSION: In suspected OA, high levels of sIgE against rHev b 5 combined with rHev b 6.01 or 6.02 are the most efficient predictors of a bronchial response to NRL.


Asunto(s)
Alérgenos/inmunología , Asma Ocupacional/diagnóstico , Asma Ocupacional/inmunología , Látex/efectos adversos , Adulto , Antígenos de Plantas/inmunología , Asma Ocupacional/tratamiento farmacológico , Biomarcadores , Femenino , Humanos , Inmunoglobulina E/sangre , Inmunoglobulina E/inmunología , Masculino , Persona de Mediana Edad , Pruebas de Función Respiratoria , Estudios Retrospectivos , Goma/efectos adversos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...