Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Thorac Cardiovasc Surg ; 136(1): 73-81, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18603056

RESUMEN

OBJECTIVE: Complexity of mitral valve repair for myxomatous disease has led to low adoption. We report initial experience with a new ring designed specifically for myxomatous disease, the Myxo-ETlogix (Edwards Lifesciences LLC, Irvine, Calif). METHODS: From March 15, 2006, through November 19, 2007, 129 patients underwent mitral valve surgery for pure myxomatous disease, and 124 valves (96.1%) were repaired. The Myxo-ETlogix ring was used in 100 cases and the Physio ring (Edwards) in 24. The Myxo-ETlogix design includes a 3-dimensional shape to reduce systolic anterior motion and a larger orifice to accommodate elongated leaflets and decrease need for sliding plasty. Direct mitral valve measurements were made. Sizing was based on A2 height, and choice of ring type was based on unresected leaflet heights. RESULTS: There was no operative mortality or lasting perioperative morbidity. The Myxo-ETlogix group had taller A2, P1, P2, and P3 leaflet segments than the Physio group (P < or = .003). Only 1 sliding plasty was performed for asymmetry in the Myxo-ETlogix group. Predischarge and follow-up echocardiograms (n = 338 in 124 patients) disclosed transient nonobstructive chordal systolic anterior motion in 3 echocardiograms in 3 patients. No patients had 2+ or greater mitral regurgitation. At discharge, 5.7% had 1+ mitral regurgitation; this proportion was 17.3% at last follow-up (mean 6.1 +/- 4.4 months). CONCLUSION: In initial experience with the Myxo-ETlogix ring, nonobstructive systolic anterior motion has been rare and obstructive systolic anterior motion not observed. Ongoing prospective echocardiographic and clinical studies will elucidate the role of this etiology-specific ring.


Asunto(s)
Prótesis Valvulares Cardíacas , Prolapso de la Válvula Mitral/terapia , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Ecocardiografía , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Diseño de Prótesis , Ajuste de Prótesis , Resultado del Tratamiento
2.
Cardiovasc Pathol ; 10(4): 179-88, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11600335

RESUMEN

BACKGROUND: Bioprosthetic heart valve use is limited by progressive degeneration. Early degenerative changes are often occult, making assessment of tissue integrity difficult. Ultrasound tissue characterization may detect alterations in tissue structure and allow early detection of leaflet degeneration. METHODS: Using a modified echocardiographic unit (Acuson), radiofrequency (RF) integrated backscatter amplitude (IBA) (integral/RF/dt) was measured in 38 leaflets from nine explanted and six control porcine valves. Regions of interest in each leaflet were studied using four ultrasound frequencies. Radiographic gray scale mean and leaflet thickness were measured at each region of interest. Percent collagen and mineral were calculated for each region of interest using color-image processing of histologic sections and compared to IBA. RESULTS: IBA values for control vs. explanted leaflets were (mean value+/-standard deviation): 8.2+/-4.69 dB vs. -4.7+/-4.64 dB at 7.0 MHz; -5.8+/-4.34 dB vs. -3.1+/-5.34 dB at 5.0 MHz; -3.8+/-3.38 dB vs. -2.1+/-3.18 dB at 3.5 MHz; and -9.0+/-4.58 dB vs. -7.1+/-4.25 dB at 2.5 MHz. Collagen content was 27.7+/-8.50% vs. 33.2+/-10.90%, mineral content was 0.1+/-0.10% vs. 2.1+/-4.30%, and radiographic gray scale mean was 150.6+/-1.96 vs. 145.3+/-5.14 for control vs. explanted leaflets, respectively. For control and explanted leaflets IBA, collagen content, mineral content, and radiographic gray scale mean were different (control vs. explanted P<0.05). Leaflet thickness was also noted to be different between the two groups. IBA was different among explanted leaflets with low, medium, and high mineral content. CONCLUSION: IBA was found to be a useful technique to differentiate normal from explanted porcine prosthetic valves in vitro. This method may be useful in the serial assessment of bioprosthetic leaflet degenerative properties in vivo.


Asunto(s)
Bioprótesis , Ecocardiografía/métodos , Prótesis Valvulares Cardíacas , Adulto , Anciano , Animales , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Calcinosis , Calcio/análisis , Colágeno/análisis , Ecocardiografía/instrumentación , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Procesamiento de Imagen Asistido por Computador , Técnicas In Vitro , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/patología , Válvula Mitral/cirugía , Ondas de Radio , Porcinos , Factores de Tiempo , Ultrasonografía
3.
J Am Soc Echocardiogr ; 14(10): 994-1000, 2001 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11593204

RESUMEN

The objective of this study was to validate a real-time 3-dimensional echocardiography (3DE) technique for the determination of left ventricular (LV) volume and ejection fraction (EF). In 10 mongrel dogs, an electromagnetic flow (EMF) probe was placed on the aorta, and the thorax was closed. Transthoracic imaging was performed during multiple hemodynamic conditions (n = 58) with simultaneous measurement of stroke volume (SV) with the use of EMF. From the volumetric data set, LV volumes were manually traced off-line by 2 independent observers with an apical rotation method (6 planes) and a conventional method (biplane) in a subset of conditions. This tracing technique was also evaluated in 18 human subjects in whom the calculated EF values were compared with values derived by multigated radionuclide angiography (MUGA). Excellent correlation and close limits of agreement were noted between SV measured by 3DE and EMF (r = 0.93) in dogs. In comparison with EMF-derived SV, 3DE provided better correlation than the biplane method (r = 0.93 versus r = 0.61). Interobserver and intraobserver variabilities were comparable (r = 0.94 and r = 0.94, respectively). In a comparison of MUGA-derived EF values and those obtained by 3DE in human subjects, 3DE provided better correlation than the biplane method (r = 0.94 versus r = 0.85). Real-time 3DE accurately measures left ventricular volumes transthoracically over a wide range of hemodynamic conditions in dogs and accurately determines EF in humans.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Animales , Perros , Estudios de Factibilidad , Imagen de Acumulación Sanguínea de Compuerta , Hemodinámica , Humanos , Modelos Lineales , Volumen Sistólico , Factores de Tiempo , Función Ventricular Izquierda
4.
Circulation ; 98(24): 2687-94, 1998 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-9851954

RESUMEN

BACKGROUND: The utility of contrast MRI for assessing myocardial viability in stable coronary artery disease (CAD) with left ventricular dysfunction is uncertain. We therefore performed cine and contrast MRI in 24 stable patients with CAD and regional contractile abnormalities and compared MRI findings with rest-redistribution 201Tl imaging and dobutamine echocardiography. METHODS AND RESULTS: Delayed MRI contrast enhancement patterns were examined from 3 to 15 minutes after injection of 0.1 mmol/kg IV gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA). Comparable MRI and 201Tl basal and midventricular short-axis images were subdivided into 6 segments. Segments judged nonviable by quantitative and qualitative assessment of 201Tl scans showed persistent, systematically greater MRI contrast signal intensity than segments judged viable (P

Asunto(s)
Cardiomiopatías/diagnóstico , Enfermedad Coronaria/diagnóstico , Imagen por Resonancia Magnética , Disfunción Ventricular Izquierda/diagnóstico , Adulto , Anciano , Cardiomiopatías/diagnóstico por imagen , Medios de Contraste , Enfermedad Coronaria/diagnóstico por imagen , Dobutamina , Femenino , Gadolinio DTPA , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Contracción Miocárdica/fisiología , Polilisina , Radioisótopos de Talio , Tomografía Computarizada de Emisión de Fotón Único , Ultrasonografía , Disfunción Ventricular Izquierda/diagnóstico por imagen
5.
Am Heart J ; 136(4 Pt 1): 718-23, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9778077

RESUMEN

OBJECTIVES: This study evaluated the effect of aortic insufficiency on the correlation of pressure half-time-derived mitral valve area with each of 2 standards for mitral valve area (planimetry and cardiac catheterization) in a prospectively assembled cohort of patients scheduled for percutaneous balloon mitral commissurotomy. BACKGROUND: Although Doppler pressure half-time has been validated as a method for assessing mitral valve area, most previous studies have suggested that this noninvasive technique overestimates mitral valve area in the setting of coexistent aortic insufficiency. METHODS AND RESULTS: Echocardiography and cardiac catheterization were performed on 212 consecutive patients scheduled for percutaneous balloon mitral commissurotomy. After excluding 35 patients who did not have aortography, the rest were divided into a "no aortic insufficiency [AI] group" (n = 146) including those with trivial or no aortic insufficiency at catheterization and an "AI group" (n = 31 ) including those with mild or moderate aortic insufficiency. The pressure half-time mitral valve area tended to slightly underestimate invasive valve area by 0.04 cm2 in the AI group and to slightly overestimate invasive valve area by 0.06 cm2 in the no AI group. This difference between the groups was not statistically significant (P = .13). The pressure half-time mitral valve area tended to underestimate planimetered valve area by 0.11 cm2 in the AI group and by 0.10 cm2 in the no AI group. There was no difference between the 2 groups (P = .94). Potential confounders that could theoretically mask the effect of aortic insufficiency on the pressure half-time (including age, heart rate, blood pressure, left ventricular diastolic pressure, ejection fraction, mitral regurgitation, and atrial fibrillation) were excluded by multivariable analyses. CONCLUSIONS: The pressure half-time method of determining mitral valve area is not adversely affected by mild to moderate aortic insufficiency. This finding has implications for the utility of this technique in the rheumatic valvular disease population, in which mitral and aortic valve disease frequently coexist.


Asunto(s)
Ecocardiografía Doppler , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Adulto , Insuficiencia de la Válvula Aórtica/complicaciones , Cateterismo Cardíaco/métodos , Factores de Confusión Epidemiológicos , Ecocardiografía Doppler/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/complicaciones , Estudios Prospectivos , Reproducibilidad de los Resultados
6.
Am J Cardiol ; 80(3): 315-22, 1997 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-9264425

RESUMEN

This study evaluates right ventricular (RV) and pulmonary function during exercise in adults with congenital heart disease (CHD). Thirty-one patients with CHD involving the right side of the heart underwent symptom-limited bicycle exercise testing with simultaneous expired gas analysis and measurement of RV ejection fraction (EF). Twenty-one age-matched normal controls underwent the identical exercise protocol. Maximal oxygen consumption was lower in the CHD than in normal controls (19.5 +/- 6.4 vs 30.5 +/- 0.8 ml/kg/min, p = 0.0001 patients vs controls). Both heart rate (156 +/- 25 vs 171 +/- 13 beats/min, p = 0.01) and oxygen pulse (9.3 +/- 3.7 vs 12.3 +/- 3.7 ml/beat, p = 0.01), an indirect measure of stroke volume, were found to be lower in the CHD group at peak exercise. Pulmonary dysfunction was evidenced in the CHD group by decreased forced expiratory volume, forced vital capacity and maximum voluntary ventilation, and by a higher ventilation/expired carbon dioxide ratio at peak exercise (37.2 +/- 6.9 vs 33.0 +/- 5.4, p = 0.02), suggesting an increase in dead space ventilation. Maximal oxygen consumption was lower in patients whose RVEF decreased with exercise (17.6 +/- 5.4 vs 22.8 +/- 6.4 ml/kg/min, p = 0.03 "decrease RVEF" group vs "increase RVEF" group). Maximal oxygen consumption correlated with the change in RVEF only in the group whose RVEF decreased with exercise (r = 0.5, p = 0.03). In the group that had increased RVEF with exercise, maximal oxygen consumption correlated with forced expiratory volume (r = 0.7, p = 0.02). Thus, adults with CHD have a reduced functional capacity compared with normal controls. This phenomenon appears to be associated with both RV and pulmonary abnormalities.


Asunto(s)
Ejercicio Físico/fisiología , Cardiopatías Congénitas/fisiopatología , Pulmón/fisiopatología , Función Ventricular Derecha/fisiología , Adulto , Presión Sanguínea , Prueba de Esfuerzo , Frecuencia Cardíaca , Humanos , Persona de Mediana Edad , Consumo de Oxígeno , Pruebas de Función Respiratoria , Volumen Sistólico
7.
Am J Cardiol ; 80(2): 236-40, 1997 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-9230175

RESUMEN

Twenty-nine patients with moderate mitral stenosis and 29 age-matched normal controls underwent symptom-limited upright bicycle exercise testing with simultaneous hemodynamic monitoring. Exercise tolerance in the mitral stenosis group was found to be limited by inadequate cardiac output reserve and not by resting mitral valve area or exercise pulmonary capillary wedge pressure.


Asunto(s)
Gasto Cardíaco , Tolerancia al Ejercicio , Estenosis de la Válvula Mitral/fisiopatología , Adulto , Anciano , Estudios de Casos y Controles , Prueba de Esfuerzo , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Análisis de Regresión
8.
Am J Cardiol ; 78(2): 131-5, 1996 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-8712131

RESUMEN

Digital coronary angiographic techniques are now widely used in many cardiac catheterization laboratories. However, the full potential of digital imaging technology remains to be achieved because of its enormous storage and exchange requirements. Compression of digital imaging data allows a reduction in the volume of data so that storage and transmission are more efficient and cost-effective. Three angiographers reviewed the original and compressed formats of 96 coronary angiographic sequences in a blinded fashion to assess coronary lesion severity. Compression was achieved using the Joint Photographic Experts Group (JPEG) standard, which resulted in a compression ratio of approximately 15:1. The original format was reviewed in a blinded fashion a second time to assess for intraobserver variability of similar formats. Lesion severity was graded in quartiles. Coronary stenosis >50% was considered "significant." In parallel, the reproducibility of quantitative coronary angiographic (QCA) measurements of coronary artery dimensions was also evaluated. For the visual assessment of lesion severity in the compressed versus original formats, kappa=0.52, suggesting moderate agreement. When lesions were assessed as significant versus "insignificant," however, kappa=0.88, suggesting excellent agreement. In the 2 separate readings of the original data formats, kappa=0.44 for assessment of lesion severity by quartiles and kappa=0.72 for lesions assessed as significant versus insignificant. Analysis of the compressed versus original data sets using QCA resulted in an excellent correlation for the measurement of lesion severity (r=0.99). The correlation was equally strong when the original format was analyzed sequentially (r=0.98). Lossy JPEG (15:1) compression is a valid means for reducing storage and exchange requirements of coronary angiographic data. The variability in assessing lesion severity between the original and compressed formats is comparable to the reported variability in visual assessment of lesion severity in sequential analysis of cine film.


Asunto(s)
Angiografía de Substracción Digital/métodos , Angiografía Coronaria/métodos , Enfermedad Coronaria/diagnóstico por imagen , Constricción Patológica , Humanos , Modelos Lineales , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos
9.
Am J Cardiol ; 76(8): 612-5, 1995 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-7677090

RESUMEN

EF in patients with aortic stenosis and reduced EF who underwent aortic valve replacement did not improve by 1 week postoperatively despite rectification of afterload mismatch. By 6 months, however, EF significantly improved without any further change in ventricular loading conditions. This implies that the benefit from aortic valve replacement (when measured by LV ejection performance) may not be evident until late postoperatively.


Asunto(s)
Estenosis de la Válvula Aórtica/fisiopatología , Bioprótesis , Prótesis Valvulares Cardíacas , Volumen Sistólico , Función Ventricular Izquierda , Anciano , Válvula Aórtica , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Estudios Prospectivos , Factores de Tiempo
10.
Circulation ; 92(4): 790-5, 1995 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-7641358

RESUMEN

BACKGROUND: Although serotonin has been postulated as an etiologic agent in the development of carcinoid heart disease, no direct evidence for different ambient serotonin levels in cardiac and noncardiac patients has been reported to date. METHODS AND RESULTS: The present study reviews our experience with 604 patients in the Duke Carcinoid Database. Nineteen patients with proven carcinoid heart disease (by cardiac catheterization and/or echocardiogram) were compared with the remaining 585 noncardiac patients in the database with regard to circulating serotonin and its principal metabolite, 5-hydroxyindole acetic acid (5-HIAA). No significant demographic differences existed between the cardiac and noncardiac groups; however, typical carcinoid syndrome symptoms (ie, flushing and diarrhea) were almost threefold more common in the cardiac group (P < .001). Compared with the noncardiac group, heart disease patients demonstrated strikingly higher (P < .0001) mean serum serotonin (9750 versus 4350 pmol/mL), plasma serotonin (1130 versus 426 pmol/mL), platelet serotonin (6240 versus 2700 pmol/mg protein), and urine 5-HIAA (219 versus 55.3 mg/24 h) levels. The spectrum of heart disease among the 19 patients showed a strong right-sided valvular predominance, with tricuspid regurgitation being the most common valvular dysfunction (92% by cardiac catheterization; 100% by echocardiogram). CONCLUSIONS: These data suggest that serotonin plays a major role in the pathogenesis of the cardiac plaque formation observed in carcinoid patients.


Asunto(s)
Cardiopatía Carcinoide/sangre , Cardiopatía Carcinoide/complicaciones , Cateterismo Cardíaco , Ecocardiografía , Enfermedades de las Válvulas Cardíacas/etiología , Serotonina/sangre , Cardiopatía Carcinoide/diagnóstico por imagen , Enfermedad Coronaria/complicaciones , Femenino , Insuficiencia Cardíaca/complicaciones , Enfermedades de las Válvulas Cardíacas/diagnóstico , Humanos , Masculino , Estudios Prospectivos , Análisis de Supervivencia
11.
Cathet Cardiovasc Diagn ; 35(1): 18-28, 1995 May.
Artículo en Inglés | MEDLINE | ID: mdl-7614536

RESUMEN

Historically, the right heart was viewed as less important than the left heart in the maintenance of normal overall hemodynamic performance. However, there is now considerable evidence that emphasizes the significance of intact right ventricular (RV) function. The RV's anatomy and physiology are reviewed in order to provide insight into how changes in volume can be accommodated within a low-pressure environment and how this contributes to hemodynamic stability. The interdependent relationship between the right and left ventricles is also explored. The contribution of RV performance to overall hemodynamics is best exemplified when the RV becomes diseased. RV infarction, atrial septal defect, and cor pulmonale are used as examples to illustrate the dramatic sequelae associated with RV dysfunction, as well as to identify the RV's specific adaptive mechanisms.


Asunto(s)
Ventrículos Cardíacos/anatomía & histología , Función Ventricular Derecha/fisiología , Defectos del Tabique Interatrial/fisiopatología , Hemodinámica/fisiología , Humanos , Infarto del Miocardio/fisiopatología , Enfermedad Cardiopulmonar/fisiopatología , Disfunción Ventricular Derecha/fisiopatología , Función Ventricular
12.
Am J Cardiol ; 75(7): 485-8, 1995 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-7863994

RESUMEN

The cardiac valvular surgical experience of patients in the Duke Carcinoid Database was reviewed to assess operative outcome. Of the 604 patients in the database, 19 patients with carcinoid heart disease were identified by cardiac catheterization or echocardiography, or both. Eight of these underwent tricuspid valve replacement surgery with bioprostheses (2 also had open pulmonic valvuloplasty). Compared with patients medically managed, surgically treated patients were similar with the exception that they had higher right atrial mean (17 +/- 6 vs 9 +/- 4 mm Hg, p = 0.03) and v-wave (27 +/- 6 vs 17 +/- 7 mm Hg, p = 0.04) pressures. Of the 8 surgical patients, 5 (63%) died within 30 days. Causes of death included tricuspid valve thrombosis, cerebral vascular accident, coagulopathy, renal failure, and intractable right heart failure. High comorbidity was present in all 8 patients. There was a weak trend (p = 0.17) toward lower Charlson comorbidity indexes in survivors (6.7 +/- 0.6) compared with nonsurvivors (7.6 +/- 0.9). Age was significantly lower (p = 0.036) in survivors (46 +/- 13 years) compared with nonsurvivors (69 +/- 4 years). Extended follow-up revealed 2 patients who survived beyond a decade. Review of 47 carcinoid valve replacement cases (Duke Carcinoid Database and 39 published cases) revealed a 30-day mortality of 56% for patients > 60 years of age, and 0% for those < or = 60 years of age (p < 0.0001). Although valve replacement surgery can afford prolonged palliation from carcinoid heart disease, it is associated with a significant mortality risk. Careful preoperative risk stratification by age and comorbidity may provide a means for optimal selection of surgical candidates.


Asunto(s)
Bioprótesis , Cardiopatía Carcinoide/cirugía , Prótesis Valvulares Cardíacas , Adulto , Factores de Edad , Anciano , Cardiopatía Carcinoide/mortalidad , Cardiopatía Carcinoide/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/cirugía , Factores de Riesgo , Tasa de Supervivencia , Resultado del Tratamiento
13.
Postgrad Med ; 90(5): 129-31, 1991 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-1924001

RESUMEN

Because of age and disease-induced pathophysiologic changes, elderly and diabetic patients are prone to hyperkalemia under even the best of circumstances. Further complicating the situation is the fact that the drugs often prescribed for these populations can affect potassium homeostasis. Drs Rigolin and Chap describe a case in which an elderly diabetic man with azotemia survived extreme drug-induced hyperkalemia.


Asunto(s)
Hiperpotasemia/inducido químicamente , Anciano , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/metabolismo , Diuréticos/efectos adversos , Humanos , Hiperpotasemia/terapia , Insulina/efectos adversos , Masculino , Potasio/administración & dosificación , Potasio/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...