Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Med Interne ; 27(5): 409-13, 2006 May.
Artículo en Francés | MEDLINE | ID: mdl-16545502

RESUMEN

INTRODUCTION: Ganglioneuroma is a rare benign nervous tumour frequently located in the retroperitoneal area. We report the case of a 22-year-old female patient where this tumour was revealed by nephritic colic complicated by pyelitis and kidney abscess. EXEGESIS: The patient presented with brutal feverish lumbar pains and urinary signs. Abundant iconography, in particular contrasted enhanced sonography, allowed to show a massive retroperitoneal lump and a puncture-biopsy indicated a ganglioneuroma which was surgically removed by laparotomy. Signs may be varied and misleading. Biological and radiological exams are useful for the diagnosis which can only be confirmed by the thorough histological examination of the removed sample. CONCLUSION: A large retroperitoneal lump without alteration of the patient's health should point to this diagnosis, since the complete surgical removal leads to recovery without recurrence, but all the other differential diagnoses must first be dismissed.


Asunto(s)
Cólico/fisiopatología , Ganglioneuroma/diagnóstico , Nefritis/complicaciones , Absceso/complicaciones , Adulto , Femenino , Ganglioneuroma/complicaciones , Humanos , Enfermedades Renales/complicaciones , Imagen por Resonancia Magnética , Pielitis/complicaciones
2.
Ann Chir ; 128(6): 397-401, 2003 Jul.
Artículo en Francés | MEDLINE | ID: mdl-12943839

RESUMEN

Gastrointestinal stromal tumours (Gist) are mesenchymal tumour with uncertain prognosis occurring in the gastrointestinal tract wall. For clinicians, these tumours raise two problems: to establish the diagnosis and to determinate the future behaviour for the choice officient therapeutics. For the diagnosis the new marker c-KIT is useful. A new treatment with an inhibitor of c-KIT has given encouraging results. currently there is no consensus on specific cut-points to distinguish as low or high risk (i.e., malignant) Gist. For metastases-free Gist, the prominent histopronostic markers are size, mitotic index and localization of the tumour. The small intestine Gist have the reputation to be more aggressive than in other localization. Skenoid fibers in small intestine Gist could be a marker of good prognostic. The authors reported three cases of small intestine Gist with skenoid fibers. The discussion point out the significance of this particular morphological aspect.


Asunto(s)
Biomarcadores de Tumor/análisis , Neoplasias Intestinales/patología , Intestino Delgado/patología , Proteínas Proto-Oncogénicas c-kit/análisis , Células del Estroma/patología , Adulto , Femenino , Humanos , Neoplasias Intestinales/cirugía , Intestino Delgado/cirugía , Masculino , Persona de Mediana Edad , Pronóstico
3.
J Chromatogr B Biomed Sci Appl ; 751(2): 265-75, 2001 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-11236082

RESUMEN

A HPLC method with automated column switching and UV detection is described for the simultaneous determination of retinol and major retinyl esters (retinyl palmitate, retinyl stearate, retinyl oleate and retinyl linoleate) in human plasma. Plasma (0.2 ml) was deproteinized by adding ethanol (1.5 ml) containing the internal standard retinyl propionate. Following centrifugation the supernatant was directly injected onto the pre-column packed with LiChrospher 100 RP-18 using 1.2% ammonium acetate-acetic acid-ethanol (80:1:20, v/v) as mobile phase. The elution strength of the ethanol containing sample solution was reduced by on-line supply of 1% ammonium acetate-acetic acid-ethanol (100:2:4, v/v). The retained retinol and retinyl esters were then transferred to the analytical column (Superspher 100 RP-18, endcapped) in the backflush mode and chromatographed under isocratic conditions using acetonitrile-methanol-ethanol-2-propanol (1:1:1:1, v/v) as mobile phase. Compounds of interest were detected at 325 nm. The method was linear in the range 2.5-2000 ng/ml with a limit of quantification for retinol and retinyl esters of 2.5 ng/ml. Mean recoveries from plasma were 93.4-96.5% for retinol (range 100-1000 ng/ml) and 92.7-96.0% for retinyl palmitate (range 5-1000 ng/ml). Inter-assay precision was < or =5.1% and < or =6.3% for retinol and retinyl palmitate, respectively. The method was successfully applied to more than 2000 human plasma samples from clinical studies. Endogenous levels of retinol and retinyl esters determined in female volunteers were in good accordance with published data.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Vitamina A/sangre , Automatización , Calibración , Ésteres , Sensibilidad y Especificidad , Espectrofotometría Ultravioleta
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...