Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Eur Radiol ; 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38724764

RESUMEN

OBJECTIVES: To conduct an intrapatient comparison of ultra-low-dose computed tomography (ULDCT) and standard-of-care-dose CT (SDCT) of the chest in terms of the diagnostic accuracy of ULDCT and intrareader agreement in patients with post-COVID conditions. METHODS: We prospectively included 153 consecutive patients with post-COVID-19 conditions. All participants received an SDCT and an additional ULDCT scan of the chest. SDCTs were performed with standard imaging parameters and ULDCTs at a fixed tube voltage of 100 kVp (with tin filtration), 50 ref. mAs (dose modulation active), and iterative reconstruction algorithm level 5 of 5. All CT scans were separately evaluated by four radiologists for the presence of lung changes and their consistency with post-COVID lung abnormalities. Radiation dose parameters and the sensitivity, specificity, and accuracy of ULDCT were calculated. RESULTS: Of the 153 included patients (mean age 47.4 ± 15.3 years; 48.4% women), 45 (29.4%) showed post-COVID lung abnormalities. In those 45 patients, the most frequently detected CT patterns were ground-glass opacities (100.0%), reticulations (43.5%), and parenchymal bands (37.0%). The accuracy, sensitivity, and specificity of ULDCT compared to SDCT for the detection of post-COVID lung abnormalities were 92.6, 87.2, and 94.9%, respectively. The median total dose length product (DLP) of ULDCTs was less than one-tenth of the radiation dose of our SDCTs (12.6 mGy*cm [9.9; 15.5] vs. 132.1 mGy*cm [103.9; 160.2]; p < 0.001). CONCLUSION: ULDCT of the chest offers high accuracy in the detection of post-COVID lung abnormalities compared to an SDCT scan at less than one-tenth the radiation dose, corresponding to only twice the dose of a standard chest radiograph in two views. CLINICAL RELEVANCE STATEMENT: Ultra-low-dose CT of the chest may provide a favorable, radiation-saving alternative to standard-dose CT in the long-term follow-up of the large patient cohort of post-COVID-19 patients.

2.
Target Oncol ; 19(2): 263-275, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38401029

RESUMEN

BACKGROUND: DNA methylation profiles have emerged as potential predictors of therapeutic response in various solid tumors. OBJECTIVE: This study aimed to analyze the DNA methylation profiles of patients with stage IV metastatic melanoma undergoing first-line immune checkpoint inhibitor treatment and evaluate their correlation with a radiological response according to immune-related Response Evaluation Criteria in Solid Tumors (iRECIST). METHODS: A total of 81 tissue samples from 71 patients with metastatic melanoma (27 female, 44 male) were included in this study. We utilized Illumina Methylation EPIC Beadchips to retrieve their genome-wide methylation profile by interrogating >850,000 CpG sites. Clustering based on the 500 most differentially methylated genes was conducted to identify distinct methylation patterns associated with immune checkpoint inhibitor response. Results were further aligned with an independent, previously published data set. RESULTS: The median progression-free survival was 8.5 months (range: 0-104.1 months), and the median overall survival was 30.6 months (range: 0-104.1 months). Objective responses were observed in 29 patients (40.8%). DNA methylation profiling revealed specific signatures that correlated with radiological response to immune checkpoint inhibitors. Three distinct clusters were identified based on the methylation patterns of the 500 most differentially methylated genes. Cluster 1 (12/12) and cluster 2 (12/24) exhibited a higher proportion of responders, while cluster 3 (39/45) predominantly consisted of non-responders. In the validation data set, responders also showed more frequent hypomethylation although differences in the data sets limit the interpretation. CONCLUSIONS: These findings suggest that DNA methylation profiling of tumor tissues might serve as a predictive biomarker for immune checkpoint inhibitor response in patients with metastatic melanoma. Further validation studies are warranted to confirm the efficiency of DNA methylation profiling as a predictive tool in the context of immunotherapy for metastatic melanoma.


Asunto(s)
Melanoma , Humanos , Masculino , Femenino , Melanoma/tratamiento farmacológico , Melanoma/genética , Melanoma/patología , Metilación de ADN , Inhibidores de Puntos de Control Inmunológico/farmacología , Inhibidores de Puntos de Control Inmunológico/uso terapéutico
3.
EClinicalMedicine ; 65: 102267, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37876998

RESUMEN

Background: Ultra-low-dose CT (ULDCT) examinations of the chest at only twice the radiation dose of a chest X-ray (CXR) now offer a valuable imaging alternative to CXR. This trial prospectively compares ULDCT and CXR for the detection rate of diagnoses and their clinical relevance in a low-prevalence cohort of non-traumatic emergency department patients. Methods: In this prospective crossover cohort trial, 294 non-traumatic emergency department patients with a clinically indicated CXR were included between May 2nd and November 26th of 2019 (www.clinicaltrials.gov: NCT03922516). All participants received both CXR and ULDCT, and were randomized into two arms with inverse reporting order. The detection rate of CXR was calculated from 'arm CXR' (n = 147; CXR first), and of ULDCT from 'arm ULDCT' (n = 147; ULDCT first). Additional information reported by the second exam in each arm was documented. From all available clinical and imaging data, expert radiologists and emergency physicians built a compound reference standard, including radiologically undetectable diagnoses, and assigned each finding to one of five clinical relevance categories for the respective patient. Findings: Detection rates for main diagnoses by CXR and ULDCT (mean effective dose: 0.22 mSv) were 9.1% (CI [5.2, 15.5]; 11/121) and 20.1% (CI [14.2, 27.7]; 27/134; P = 0.016), respectively. As an additional imaging modality, ULDCT added 9.1% (CI [5.2, 15.5]; 11/121) of main diagnoses to prior CXRs, whereas CXRs did not add a single main diagnosis (0/134; P < 0.001). Notably, ULDCT also offered higher detection rates than CXR for all other clinical relevance categories, including findings clinically irrelevant for the respective emergency department visit with 78.5% (CI [74.0, 82.5]; 278/354) vs. 16.2% (CI [12.7, 20.3]; 58/359) as a primary modality and 68.2% (CI [63.3, 72.8]; 245/359) vs. 2.5% (CI [1.3, 4.7]; 9/354) as an additional imaging modality. Interpretation: In non-traumatic emergency department patients, ULDCT of the chest offered more than twice the detection rate for main diagnoses compared to CXR. Funding: The Department of Biomedical Imaging and Image-guided Therapy of Medical University of Vienna received funding from Siemens Healthineers (Erlangen, Germany) to employ two research assistants for one year.

4.
Orphanet J Rare Dis ; 18(1): 57, 2023 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-36927364

RESUMEN

BACKGROUND: Diprosopus is a rare malformation of still unclear aetiology. It describes a laterally double faced monocephalic and single-trunk individual and has to be distinguished from the variant Janus type diprosopus. RESULTS: We examined seven double-faced foetuses, five showing true diprosopus, and one each presenting as monocephalic Janiceps and parasitic conjoined twins. Four of the foetuses presented with (cranio)rachischisis, and two had secondary hydrocephaly. Three foetuses showed cerebral duplication with concordant holoprosencephaly, Dandy-Walker cyst and/or intracranial anterior encephalocele. In the Janiceps twins, cerebral duplication was accompanied by cerebral di-symmetry. In the parasitic twins the cyclopic facial aspects were suggestive of concordant holoprosencephaly. In one of the true diprosopus cases, pregnancy was achieved after intracytoplasmic sperm injection. Whole-exome sequencing, perfomed in one case, did not reveal any possible causative variants.The comparison of our double-faced foetuses to corresponding artistic representations from the Tlatilco culture allowed retrospective assignment of hairstyles to brain malformations. CONCLUSION: Brain malformations in patients with diprosopus may not be regarded as an independent event but rather as a sequel closely related to the duplication of the notochord and neural plate and as a consequence of the cerebral and associated craniospinal structural instabilities.


Asunto(s)
Holoprosencefalia , Gemelos Siameses , Embarazo , Femenino , Humanos , Masculino , Holoprosencefalia/genética , Museos , Estudios Retrospectivos , Semen , Encéfalo
5.
Am J Med Genet A ; 191(5): 1301-1324, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36806455

RESUMEN

The collection of the Narrenturm in Vienna houses and maintains more than 50,000 objects including approximately 1200 teratological specimens; making it one of the biggest collections of specimens from human origin in Europe. The existence of this magnificent collection-representing an important resource for dysmorphology research, mostly awaiting contemporary diagnoses-is not widely known in the scientific community. Here, we show that the Narrenturm harbors a wealth of specimens with (exceptionally) rare congenital anomalies. These museums can be seen as physical repositories of human malformation, covering hundreds of years of dedicated collecting and preserving, thereby creating unique settings that can be used to expand our knowledge of developmental conditions that have to be preserved for future generations of scientists.


Asunto(s)
Museos , Teratología , Humanos , Austria , Europa (Continente) , Examen Físico
6.
J Bone Joint Surg Am ; 105(8): 620-629, 2023 04 19.
Artículo en Inglés | MEDLINE | ID: mdl-36848437

RESUMEN

BACKGROUND: Metal artifacts caused by hip arthroplasty stems limit the diagnostic value of computed tomography (CT) in the evaluation of periprosthetic fractures or implant loosening. The aim of this ex vivo study was to evaluate the influence of different scan parameters and metal artifact algorithms on image quality in the presence of hip stems. METHODS: Nine femoral stems, 6 uncemented and 3 cemented, that had been implanted in subjects during their lifetimes were exarticulated and investigated after death and anatomical body donation. Twelve CT protocols consisting of single-energy (SE) and single-source consecutive dual-energy (DE) scans with and without an iterative metal artifact reduction algorithm (iMAR; Siemens Healthineers) and/or monoenergetic reconstructions were compared. Streak and blooming artifacts as well as subjective image quality were evaluated for each protocol. RESULTS: Metal artifact reduction with iMAR significantly reduced the streak artifacts in all investigated protocols (p = 0.001 to 0.01). The best subjective image quality was observed for the SE protocol with a tin filter and iMAR. The least streak artifacts were observed for monoenergetic reconstructions of 110, 160, and 190 keV with iMAR (standard deviation of the Hounsfield units: 151.1, 143.7, 144.4) as well as the SE protocol with a tin filter and iMAR (163.5). The smallest virtual growth was seen for the SE with a tin filter and without iMAR (4.40 mm) and the monoenergetic reconstruction of 190 keV without iMAR (4.67 mm). CONCLUSIONS: This study strongly suggests that metal artifact reduction algorithms (e.g., iMAR) should be used in clinical practice for imaging of the bone-implant interface of prostheses with either an uncemented or cemented femoral stem. Among the iMAR protocols, the SE protocol with 140 kV and a tin filter produced the best subjective image quality. Furthermore, this protocol and DE monoenergetic reconstructions of 160 and 190 keV with iMAR achieved the lowest levels of streak and blooming artifacts. LEVEL OF EVIDENCE: Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artefactos , Humanos , Estaño , Metales , Tomografía Computarizada por Rayos X/métodos , Algoritmos
7.
Nutrients ; 14(16)2022 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-36014952

RESUMEN

Measuring skeletal muscle area (SMA) at the third lumbar vertebra level (L3) using computed tomography (CT) is increasingly popular for diagnosing low muscle mass. The aim was to describe the effect of the CT L3 cut-off choice on the prevalence of low muscle mass in medical and surgical patients. Two hundred inpatients, who underwent an abdominal CT scan for any reason, were included. Skeletal muscle area (SMA) was measured according to Hounsfield units on a single CT scan at the L3 level. First, we calculated sex-specific cut-offs, adjusted for height or BMI and set at mean or mean-2 SD in our population. Second, we applied published cut-offs, which differed in statistical calculation and adjustment for body stature and age. Statistical calculation of the cut-off led to a prevalence of approximately 50 vs. 1% when cut-offs were set at mean vs. mean-2 SD in our population. Prevalence varied between 5 and 86% when published cut-offs were applied (p < 0.001). The adjustment of the cut-off for the same body stature variable led to similar prevalence distribution patterns across age and BMI classes. The cut-off choice highly influenced prevalence of low muscle mass and prevalence distribution across age and BMI classes.


Asunto(s)
Sarcopenia , Femenino , Humanos , Vértebras Lumbares/diagnóstico por imagen , Masculino , Músculo Esquelético/fisiología , Prevalencia , Estudios Retrospectivos , Sarcopenia/epidemiología , Tomografía Computarizada por Rayos X/métodos
9.
Clin Nutr ; 41(4): 829-837, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35263692

RESUMEN

BACKGROUND & AIMS: Skeletal muscle area (SMA) in the computed tomography (CT) at the third lumbar vertebra (L3) level is a proxy for whole-body muscle mass but is only performed for clinical reasons. Ultrasound is a promising tool to determine muscle mass at the bedside. It is still unclear how well ultrasound and which ultrasound measuring points can predict CT L3 SMA. METHODS: This prospective observational trial included 200 non-critically ill patients, who underwent an abdominal CT scan for any clinical reason within 48 h before the ultrasound examination. Ultrasound muscle thickness was evaluated at 3 measuring points on the thigh and 2 measuring points on the upper arm with minimal compression. On the CT scan, the entire L3 SMA was measured based on Hounsfield units. Using a model selection algorithm based on the Bayesian information criterion (BIC) and clinical considerations, a linear prediction model for CT L3 SMA based on the ultrasound muscle thickness and other independent variables was fitted and assessed with cross-validation. RESULTS: 67,5% and 32,5% of the patients were from surgical and medical wards, respectively. Mean ultrasound muscle thickness values were between 2,2 and 3,6 cm on the thigh and between 1,4 and 2,8 cm on the upper arm. All ultrasound muscle thickness values were higher in men than in women (P < 0,05). CT L3 SMA was 40 cm2 higher in men than in women (P < 0,001). The final prediction model for CT L3 SMA included the following 4 independent variables: ultrasound muscle thickness at the ventral measuring point of the thigh in the short-axis plane, sex, weight, and height. It had a similar BIC (BIC of 1515) compared to larger models with 6-8 independent variables including multiple ultrasound measuring points (BIC of 1506-1519). Additional clinical considerations to choose the final model were less time consumption when measuring a single ultrasound measuring point and better anatomical overview at the short-axis plane. The final model predicted CT L3 SMA with a R2 of 0,74 (P < 0,001) and a cross-validated R2 of 0,65. CONCLUSIONS: One single ultrasound measuring point at the thigh together with sex, height and weight very well predicts CT L3 SMA across different clinical populations. Ultrasound is a safe and bedside method to measure muscle thickness longitudinally to monitor the effects of nutrition and physical therapy.


Asunto(s)
Músculo Esquelético , Sarcopenia , Teorema de Bayes , Femenino , Humanos , Masculino , Músculo Esquelético/diagnóstico por imagen , Estudios Prospectivos , Tomografía Computarizada por Rayos X , Ultrasonografía
11.
Eur Radiol ; 30(8): 4295-4305, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32242275

RESUMEN

OBJECTIVES: Previous studies have shown that split-bolus protocols in virtual non-contrast (VNC) reconstructions of dual-energy computed tomography (DE-CT) significantly decrease radiation dose in patients with urinary stone disease. To evaluate the impact on kidney stone detection rate of stone composition, size, tube voltage, and iodine concentration for VNC reconstructions of DE-CT. METHODS: In this prospective study, 16 kidney stones of different sizes (1.2-4.5 mm) and compositions (struvite, cystine, whewellite, brushite) were placed within a kidney phantom. Seventy-two scans with nine different iodine contrast agents/saline solutions with increasing attenuation (0-1400 HU) and different kilovoltage settings (70 kV/150 kV; 80 kV/150 kV; 90 kV/150 kV; 100 kV/150 kV) were performed. Two experienced radiologists independently rated the images for the presence and absence of stones. Multivariate classification tree analysis and descriptive statistics were used to evaluate the diagnostic performance. RESULTS: Classification tree analysis revealed a higher detection rate of renal calculi > 2 mm in size compared with that of renal calculi < 2 mm (84.7%; 12.7%; p < 0.001). For stones with a diameter > 2 mm, the best results were found at 70 kV/Sn 150 kV and 80 kV/Sn 150 kV in scans with contrast media attenuation of 600 HU or less, with sensitivity of 99.6% and 96.0%, respectively. A higher luminal attenuation (> 600 HU) resulted in a significantly decreased detection rate (91.8%, 0-600 HU; 70.7%, 900-1400 HU; p < 0.001). In our study setup, the detection rates were best for cystine stones. CONCLUSION: Scan protocols in DE-CT with lower tube current and lower contrast medium attenuation show excellent results in VNC for stones larger than 2 mm but have limitations for small stones. KEY POINTS: • The detection rate of virtual non-contrast reconstructions is highly dependent on the surrounding contrast medium attenuation at the renal pelvis and should be kept as low as possible, as at an attenuation higher than 600 HU the VNC reconstructions are susceptible to masking ureteral stones. • Protocols with lower tube voltages (70 kV/Sn 150 kV and 80 kV/Sn 150 kV) improve the detection rate of kidney stones in VNC reconstructions. • The visibility of renal stones in virtual non-contrast of dual-energy CT is highly associated with the size, and results in a significantly lower detection rate in stones below 2 mm.


Asunto(s)
Medios de Contraste , Procesamiento de Imagen Asistido por Computador/métodos , Cálculos Renales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Oxalato de Calcio , Fosfatos de Calcio , Cistina , Humanos , Yodo , Fantasmas de Imagen , Estudios Prospectivos , Dosis de Radiación , Estruvita , Cálculos Urinarios
12.
Insights Imaging ; 11(1): 47, 2020 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-32170498

RESUMEN

CT colonography (CTC) is the radiological examination of choice for the diagnosis of colorectal neoplasia. Faecal tagging is considered a mandatory part of bowel preparation. However, the colonic mucosa, obscured by tagged residue, is not accessible to endoluminal 3D views and requires time-consuming 2D evaluation. Electronic cleansing (EC) software algorithms can overcome this limitation by digitally subtracting tagged residue from the colonic lumen. Ideally, this enables a seamless 3D endoluminal evaluation. Despite this benefit, EC is a potential source of a wide range of artefacts. Accurate EC requires proper CTC examination technique and faecal tagging. The digital subtraction process has been shown to affect the relevant morphological features of both colonic anatomy and colonic lesions, if submerged under faecal residue. This article summarises the potential effects of EC on CTC imaging, the consequences for reporting and patient management, and strategies to avoid pitfalls. Furthermore, potentially negative effects on clinical reporting and patient management are shown, and problem-solving techniques, as well as recommendations for the appropriate use of EC techniques, are presented. Radiologists using EC should be familiar with EC-related effects on polyp size and also with correct measurement techniques.

13.
PLoS One ; 15(2): e0228376, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32023294

RESUMEN

OBJECTIVES: The purpose of this study was to investigate the impact of a 150kV spectral filtration chest imaging protocol (Sn150kVp) combined with advanced modeled iterative reconstruction (ADMIRE) on radiation dose and image quality in patients after lung-transplantation. METHODS: This study included 102 patients who had unenhanced chest-CT examinations available on both, a second-generation dual-source CT (DSCT) using standard protocol (100kVp, filtered-back-projection) and, on a third-generation DSCT using Sn150kVp protocol with ADMIRE. Signal-to-noise-ratio (SNR) was measured in 6 standardized regions. A 5-point Likert scale was used to evaluate subjective image quality. Radiation metrics were compared. RESULTS: The mean time interval between the two acquisitions was 1.1±0.7 years. Mean-volume-CT-dose-index, dose-length-product and effective dose were significantly lower for Sn150kVp protocol (2.1±0.5mGy;72.6±16.9mGy*cm;1.3±0.3mSv) compared to 100kVp protocol (6.2±1.8mGy;203.6±55.6mGy*cm;3.7±1.0mSv) (p<0.001), equaling a 65% dose reduction. All studies were considered of diagnostic quality. SNR measured in lung tissue, air inside trachea, vertebral body and air outside the body was significantly higher in 100kVp protocol compared to Sn150kVp protocol (12.5±2.7vs.9.6±1.5;17.4±3.6vs.11.8±1.8;0.7±0.3vs.0.4±0.2;25.2±6.9vs.14.9±3.3;p<0.001). SNR measured in muscle tissue was significantly higher in Sn150kVp protocol (3.2±0.9vs.2.6±1.0;p<0.001). For SNR measured in descending aorta there was a trend towards higher values for Sn150kVp protocol (2.8±0.6 vs. 2.7±0.9;p = 0.3). Overall SNR was significantly higher in 100kVp protocol (5.0±4.0vs.4.0±4.0;p<0.001). On subjective analysis both protocols achieved a median Likert rating of 1 (25th-75th-percentile:1-1;p = 0.122). Interobserver agreement was good (intraclass correlation coefficient = 0.73). CONCLUSIONS: Combined use of 150kVp tin-filtered chest CT protocol with ADMIRE allows for significant dose reduction while maintaining highly diagnostic image quality in the follow up after lung transplantation when compared to a standard chest CT protocol using filtered back projection.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Enfermedades Pulmonares/diagnóstico por imagen , Trasplante de Pulmón/métodos , Intensificación de Imagen Radiográfica/instrumentación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Femenino , Humanos , Enfermedades Pulmonares/cirugía , Masculino , Persona de Mediana Edad , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Estudios Retrospectivos , Relación Señal-Ruido , Estaño
14.
World J Urol ; 38(11): 2971-2979, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31993735

RESUMEN

PURPOSE: To assess a novel low-dose CT-protocol, combining a 150 kV spectral filtration unenhanced protocol (Sn150 kVp) and a stone-targeted dual-energy CT (DECT) in patients with urolithiasis. METHODS: 232 (151 male, 49 ± 16.4 years) patients with urolithiasis received a low-dose non-contrast enhanced CT (NCCT) for suspected urinary stones either on a third-generation dual-source CT system (DSCT) using Sn150 kVp (n = 116, group 1), or on a second-generation DSCT (n = 116 group 2) using single energy (SE) 120 kVp. For group 1, a subsequent dual-energy CT (DECT) with a short stone-targeted scan range was performed. Objective and subjective image qualities were assessed. Radiation metrics were compared. RESULTS: 534 stones (group 1: n = 242 stones; group 2: n = 292 stones) were found. In group 1, all 215 stones within the stone-targeted DECT-scan range were identified. DE analysis was able to distinguish between UA and non-UA calculi in all collected stones. 11 calculi (5.12%) were labeled as uric acid (UA) while 204 (94.88%) were labeled as non-UA calculi. There was no significant difference in overall Signal-to-noise-ratio between group 1 and group 2 (p = 0.819). On subjective analysis both protocols achieved a median Likert rating of 2 (p = 0.171). Mean effective dose was significantly lower for combined Sn150 kVp and stone-targeted DECT (3.34 ± 1.84 mSv) compared to single energy 120 kVp NCCT (4.45 ± 2.89 mSv) (p < 0.001), equaling a 24.9% dose reduction. CONCLUSION: The evaluated novel low-dose stone composition protocol allows substantial radiation dose reduction with consistent high diagnostic image quality.


Asunto(s)
Tomografía Computarizada por Rayos X/métodos , Cálculos Urinarios/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Estudios Retrospectivos
15.
PLoS One ; 14(12): e0225673, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31856177

RESUMEN

PURPOSE: Advanced forms of prostate cancer (PCa) radiotherapy with either external beam therapy or brachytherapy delivery techniques aim for a focal boost and thus require accurate lesion localization and lesion segmentation for subsequent treatment planning. This study prospectively evaluated dynamic contrast-enhanced computed tomography (DCE-CT) for the detection of prostate cancer lesions in the peripheral zone (PZ) using qualitative and quantitative image analysis compared to multiparametric magnet resonance imaging (mpMRI) of the prostate. METHODS: With local ethics committee approval, 14 patients (mean age, 67 years; range, 57-78 years; PSA, mean 8.1 ng/ml; range, 3.5-26.0) underwent DCE-CT, as well as mpMRI of the prostate, including standard T2, diffusion-weighted imaging (DWI), and DCE-MRI sequences followed by transrectal in-bore MRI-guided prostate biopsy. Maximum intensity projections (MIP) and DCE-CT perfusion parameters (CTP) were compared between healthy and malignant tissue. Two radiologists independently rated image quality and the tumor lesion delineation quality of PCa using a five-point ordinal scale. MIP and CTP were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/area under the curve (AUC) analysis. RESULTS: The PCa detection rate ranged between 57 to 79% for the two readers for DCE-CT and was 92% for DCE-MRI. DCE-CT perfusion parameters in PCa tissue in the PZ were significantly different compared to regular prostate tissue and benign lesions. Image quality and lesion visibility were comparable between DCE-CT and DCE-MRI (VGC: AUC 0.612 and 0.651, p>0.05). CONCLUSION: Our preliminary results suggest that it is feasible to use DCE-CT for identification and visualization, and subsequent segmentation for focal radiotherapy approaches to PCa.


Asunto(s)
Tomografía Computarizada Cuatridimensional/métodos , Imagen de Perfusión/métodos , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Anciano , Biopsia con Aguja Gruesa , Medios de Contraste/administración & dosificación , Imagen de Difusión por Resonancia Magnética , Estudios de Factibilidad , Humanos , Biopsia Guiada por Imagen , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Prueba de Estudio Conceptual , Estudios Prospectivos , Próstata/diagnóstico por imagen , Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Dosis de Radiación
16.
Eur Radiol ; 29(7): 3617-3625, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30888484

RESUMEN

OBJECTIVES: The aim of this study was to assess the objective and subjective image characteristics of monoenergetic images (MEI[+]), using a noise-optimized algorithm at different kiloelectron volts (keV) compared to polyenergetic images (PEI), in patients with pancreatic ductal adenocarcinoma (PDAC). METHODS: This retrospective, institutional review board-approved study included 45 patients (18 male, 27 female; mean age 66 years; range, 42-96 years) with PDAC who had undergone a dual-energy CT (DECT) of the abdomen for staging. One standard polyenergetic image (PEI) and five MEI(+) images in 10-keV intervals, ranging from 40 to 80 keV, were reconstructed. Line-density profile analysis, as well as the contrast-to-noise ratio (CNR) of the tumor, the signal-to-noise ratio (SNR) of the regular pancreas parenchyma and the tumor, and the CNR of the three main peripancreatic vessels, was calculated. For subjective quality assessment, two readers independently assessed the images using a 5-point Likert scale. Reader reliability was evaluated using an intraclass correlation coefficient. RESULTS: Line-density profile analysis revealed the largest gradient in attenuation between PDAC and regular tissue in MEI(+) at 40 keV. Low-keV MEI(+)reconstructions at 40 and 50 keV increased CNR and SNR compared to PEI (40 keV: CNR 46.8 vs. 7.5; SNRPankreas 32.5 vs. 15.7; SNRLesion 13.5 vs. 8.6; p < 0.001). MEI(+) at 40 keV and 50 keV were consistently preferred by the observers (p < 0.05), showing a high intra-observer 0.937 (0.92-0.95) and inter-observer 0.911 (0.89-0.93) agreement. CONCLUSION: MEI(+) reconstructions at 40 keV and 50 keV provide better objective and subjective image quality compared to conventional PEI of DECT in patients with PDAC. KEY POINTS: • Low-keV MEI(+) reconstructions at 40 and 50 keV increase tumor-to-pancreas contrast compared to PEI. • Low-keV MEI(+) reconstructions improve objective and subjective image quality parameters compared to PEI. • Dual-energy post-processing might be a valuable tool in the diagnostic workup of patients with PDAC.


Asunto(s)
Algoritmos , Carcinoma Ductal Pancreático/diagnóstico , Procesamiento de Imagen Asistido por Computador/métodos , Páncreas/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Realidad Virtual , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
17.
Knee Surg Sports Traumatol Arthrosc ; 27(5): 1552-1561, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-29881885

RESUMEN

PURPOSE: To evaluate the influence of different scan parameters for single-energy CT and dual-energy CT, as well as the impact of different material used in a TKA prosthesis on image quality and the extent of metal artifacts. METHODS: Eight pairs of TKA prostheses from different vendors were examined in a phantom set-up. Each pair consisted of a conventional CoCr prosthesis and the corresponding anti-allergic prosthesis (full titanium, ceramic, or ceramic-coated) from the same vendor. Nine different (seven dual-energy CT and two single-energy CT) scan protocols with different characteristics were used to determine the most suitable CT protocol for TKA imaging. Quantitative image analysis included assessment of blooming artifacts (metal implants appear thicker on CT than they are, given as virtual growth in mm in this paper) and streak artifacts (thick dark lines around metal). Qualitative image analysis was used to investigate the bone-prosthesis interface. RESULTS: The full titanium prosthesis and full ceramic knee showed significantly fewer blooming artifacts compared to the standard CoCr prosthesis (mean virtual growth 0.6-2.2 mm compared to 2.9-4.6 mm, p < 0.001). Dual-energy CT protocols showed less blooming (range 3.3-3.8 mm) compared to single-energy protocols (4.6-5.5 mm). The full titanium and full ceramic prostheses showed significantly fewer streak artifacts (mean standard deviation 77-86 Hounsfield unit (HU)) compared to the standard CoCr prosthesis (277-334 HU, p < 0.001). All dual-energy CT protocols had fewer metal streak artifacts (215-296 HU compared to single-energy CT protocols (392-497 HU)). Full titanium and ceramic prostheses were ranked superior with regard to the image quality at the bone/prosthesis interface compared to a standard CoCr prosthesis, and all dual-energy CT protocols were ranked better than single-energy protocols. CONCLUSIONS: Dual-energy CT and ceramic or titanium prostheses reduce CT artifacts and provide superior image quality of total knee arthroplasty at the bone/prosthesis interface. These findings support the use of dual-energy CT as a solid imaging base for clinical decision-making and the use of full-titanium or ceramic prostheses to allow for better CT visualization of the bone-prosthesis interface.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Artefactos , Metales/química , Interpretación de Imagen Radiográfica Asistida por Computador , Titanio/química , Cerámica/química , Aleaciones de Cromo/química , Materiales Biocompatibles Revestidos/química , Simulación por Computador , Humanos , Fantasmas de Imagen , Prótesis e Implantes , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
18.
Eur Radiol ; 28(11): 4766-4774, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29761359

RESUMEN

OBJECTIVES: To assess whether electronic cleansing (EC) of tagged residue and different computed tomography (CT) windows influence the size of colorectal polyps in CT colonography (CTC). METHODS: A database of 894 colonoscopy-validated CTC datasets of a low-prevalence cohort was retrospectively reviewed to identify patients with polyps ≥6 mm that were entirely submerged in tagged residue. Ten radiologists independently measured the largest diameter of each polyp, two-dimensionally, before and after EC in colon, bone, and soft-tissue-windows, in randomised order. Differences in size and polyp count before and after EC were calculated for size categories ≥6 mm and ≥10 mm. Statistical testing involved 95% confidence interval, intraclass correlation and mixed-model ANOVA. RESULTS: Thirty-seven patients with 48 polyps were included. Mean polyp size before EC was 9.8 mm in colon, 9.9 mm in bone and 8.2 mm in soft-tissue windows. After EC, the mean polyp size decreased significantly to 9.4 mm in colon, 9.1 mm in bone and 7.1 mm in soft-tissue windows. Compared to unsubtracted colon windows, EC, performed in colon, bone and soft-tissue windows, led to a shift of 6 (12,5%), 10 (20.8%) and 25 (52.1%) polyps ≥6 mm into the next smaller size category, thus affecting patient risk stratification. CONCLUSIONS: EC and narrow CT windows significantly reduce the size of polyps submerged in tagged residue. Polyp measurements should be performed in unsubtracted colon windows. KEY POINTS: • EC significantly reduces the size of polyps submerged in tagged residue. • Abdominal CT-window settings significantly underestimate 2D sizes of submerged polyps. • Size reduction in EC is significantly greater in narrow than wide windows. • Underestimation of polyp size due to EC may lead to inadequate treatment. • Polyp measurements should be performed in unsubtracted images using a colon window.


Asunto(s)
Pólipos del Colon/diagnóstico por imagen , Colonografía Tomográfica Computarizada/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Anciano , Algoritmos , Análisis de Varianza , Colonografía Tomográfica Computarizada/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estándares de Referencia , Estudios Retrospectivos , Sensibilidad y Especificidad
19.
Eur Radiol ; 28(11): 4748-4756, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29767320

RESUMEN

OBJECTIVES: To compare the value of functional future liver remnant (functFLR) to established clinical and imaging variables in prediction of post-hepatectomy liver failure (PHLF) after major liver resection. METHODS: This retrospective, cross-sectional study included 62 patients, who underwent gadoxetic acid enhanced MRI and MDCT within 10 weeks prior to resection of ≥ 4 liver segments. Future liver remnant (FLR) was measured in MDCT using semi-automatic software. Relative liver enhancement for each FLR segment was calculated as the ratio of signal intensity of parenchyma before and 20 min after i.v. administration of gadoxetic acid and given as mean (remnantRLE). Established variables included indocyanine green clearance, FLR, proportion of FLR, weight-adapted FLR and remnantRLE. functFLR was calculated as FLR multiplied by remnantRLE and divided by patient's weight. The association of measured variables and PHLF was tested with univariate and multivariate logistic regression analysis and receiver operator characteristics (ROC) curves compared with the DeLong method. RESULTS: Sixteen patients (25.8%) experienced PHLF. Univariate logistic regression identified FLR (p = 0.015), proportion of FLR (p = 0.004), weight-adapted FLR (p = 0.003), remnantRLE (p = 0.002) and functFLR (p = 0.002) to be significantly related to the probability of PHLF. In multivariate logistic regression analysis, a decreased functFLR was independently associated with the probability of PHLF (0.561; p = 0.002). Comparing ROC curves, functFLR showed a significantly higher area under the curve (0.904; p < 0.001) than established variables. CONCLUSIONS: functFLR seems to be superior to established variables in prediction of PHLF after major liver resection. KEY POINTS: • functFLR is a parameter combining volumetric and functional imaging information, derived from MDCT and gadoxetic acid enhanced MRI. • In comparison to other established methods, functFLR is superior in prediction of post-hepatectomy liver failure. • functFLR could help to improve patient selection prior major hepatic surgery.


Asunto(s)
Hepatectomía , Fallo Hepático/diagnóstico , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/cirugía , Imagen por Resonancia Magnética/métodos , Complicaciones Posoperatorias/diagnóstico , Adulto , Anciano , Estudios Transversales , Femenino , Gadolinio DTPA/administración & dosificación , Humanos , Verde de Indocianina/administración & dosificación , Pruebas de Función Hepática , Neoplasias Hepáticas/diagnóstico por imagen , Modelos Logísticos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos
20.
Am J Cardiol ; 119(8): 1156-1161, 2017 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-28233536

RESUMEN

The aim of this study was to assess the image quality (IQ) and radiation dose of third-generation dual-source computed tomography (CT) coronary angiography (cCTA) in comparison with 64-slice single-source CT. This retrospective study included 140 patients (73 men, mean age 62 ± 11 years) with low-to-intermediate probability of coronary artery disease who underwent either third-generation dual-source cCTA using prospectively electrocardiography-triggered high-pitch spiral acquisition (n = 70) (group 1) or retrospective electrocardiography-gated cCTA on a 64-slice CT system (n = 70) (group 2). Contrast-to-noise and signal-to-noise ratios were measured within the aorta and coronary arteries. Subjective IQ was assessed using a 5-point Likert scale. Effective dose was estimated using specific conversion factors. The contrast-to-noise ratio of group 1 was significantly higher than group 2 at all levels (all p <0.001). Signal-to-noise ratio of group 1 was also significantly higher than group 2 (p <0.05), except for the distal left circumflex artery. Subjective IQ for group 1 was rated significantly better than for group 2 (median score [25th to 75th percentile]: 1 [1 to 2] vs 2 [2 to 3]; p <0.001). The median effective dose was 1.55 mSv (1.09 to 1.88) in group 1 versus 12.29 mSv (11.63 to 14.36) in group 2 (p <0.001) which corresponds to a mean radiation dose reduction of 87.4%. In conclusion, implementation of third-generation dual-source CT system for cCTA leads to improved IQ with significant radiation dose savings.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas , Angiografía Coronaria/métodos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Electrocardiografía , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...