Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Infect Dis ; 78(4): 930-936, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38330172

RESUMEN

BACKGROUND: The 2023 Duke-ISCVID (International Society of Cardiovascular Infectious Diseases) classification is a new diagnostic tool for infective endocarditis, updating the 2000 modified Duke and the 2015 European Society for Cardiology (ESC) classifications. In comparison, its sensitivity is higher; however, its specificity remains to be evaluated and compared to that of the 2 other classifications in endocarditis suspected patients. METHODS: We retrospectively collected the characteristics of patients hospitalized in Bichat University's Hospital, Paris, in 2021, who had been evaluated for clinical suspicion of endocarditis, have had at least a transthoracic echocardiography, 2 pairs of blood cultures, 3-month follow-up and in whom endocarditis diagnosis was finally rejected. All patients were classified by 2000 modified Duke, 2015 ESC and 2023 Duke-ISCVID, as though the endocarditis diagnosis had not been rejected. RESULTS: In total, 130 patients' charts were analyzed. Mean age was 62 years, 84 (64.6%) were male, 39 (30.0%) had prosthetic cardiac valve or valve repair, 21 (16.2%) cardiac implanted electronic device, and 30 (23.1%) other cardiac conditions. Overall, 5, 2, and 5 patients were falsely classified as definite endocarditis with the 2000 modified Duke, 2015 ESC, and 2023 Duke-ISCVID classifications, respectively. The corresponding specificities were 96.2% (95% confidence interval [CI] [90.8%, 98.6%]), 98.5% (95% CI [93.9%, 99.7%]), and 96.2% (95% CI [90.8%, 98.6%]). The rates of possible endocarditis were of 38%, 35%, and 35% in the 3 classifications, respectively. CONCLUSIONS: The 2023 Duke-ISCVID classification is highly specific for ruling out the diagnosis of definite infective endocarditis in patients who had been evaluated for IE.


Asunto(s)
Enfermedades Transmisibles , Endocarditis Bacteriana , Endocarditis , Humanos , Masculino , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Endocarditis Bacteriana/diagnóstico , Endocarditis/diagnóstico , Ecocardiografía
2.
Stud Health Technol Inform ; 290: 1002-1003, 2022 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-35673176

RESUMEN

BACKGROUND: Although the drug is finished, identifiable, there is no universally accepted standard for naming them. The objective of this work is to evaluate qualitatively the HeTOP drug terminology server by two categories of students: (a) pharmacy students and (b) a control group. METHODS: A formal evaluation was built to measure the perception of users about the HeTOP drug server, using the three mains questions about "teaching interest", "skill interest" (or competence) and "ergonomics". RESULTS: The three pharmacy student subgroups gave the best and the worst score to the same categories. CONCLUSION: All three criteria are rated above 6.5 out of 10. The HeTOP drug terminology server is freely available to "non drug" specialists (URL: www.hetop.eu/hetop/drugs/).


Asunto(s)
Estudiantes de Farmacia , Humanos , Farmacéuticos
3.
Eur J Haematol ; 109(1): 41-49, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35285085

RESUMEN

OBJECTIVES: Both peripherally inserted central catheters (PICCs) and implanted port catheters (PORTs) are commonly used for the delivery of immunochemotherapy. We compared the safety of the two types of devices in a homogeneous and monocentric population of diffuse large B-cell lymphoma (DLBCL) patients who were treated with first-line immunochemotherapy by evaluating the numbers of catheter-related venous thromboses (VTs) and infections that occurred in the six months after implantation according to the type of device. METHODS: Using a propensity score, the adjusted relative risk (ARR) between the type of catheter and the occurrence of catheter-related complications (infection and/or VT) of interest was retrospectively determined. RESULTS: 479 patients were enrolled (266 PORTs/213 PICCs), and 26 VTs (5.4%) and 30 infections (6.3%) were identified in the period following PICC/PORT implantation. The adjusted relative risk (ARR) of catheter-related complications (infection and/or VT) according to the type of device was 2.6 (95% CI =1.3-5.9, p = .0075). This risk increase associated with the PICC device was significant for both infections (ARR = 3.2; 95% CI = 1.3-10.9) and thrombosis (ARR = 4; 95% CI = 1.5-11.6). CONCLUSION: Our study supports the preferential use of PORTs for the first line of treatment for DLBCL patients.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Catéteres Venosos Centrales , Linfoma de Células B Grandes Difuso , Infecciones Relacionadas con Catéteres/diagnóstico , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/etiología , Cateterismo Venoso Central/efectos adversos , Catéteres Venosos Centrales/efectos adversos , Humanos , Linfoma de Células B Grandes Difuso/diagnóstico , Linfoma de Células B Grandes Difuso/tratamiento farmacológico , Estudios Retrospectivos , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...