Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38529662

RESUMEN

OBJECTIVE: The bone conduction implant (BCI) 602 is a new transcutaneous BCI with smaller dimensions. However, limited patient numbers restrict the statistical power and generalizability of the current studies. The present systematic review and meta-analysis summarize early audiological and medical outcomes of adult and pediatric patients implanted with the BCI 602 due to mixed or conductive hearing loss. DATA SOURCE: Following the Preferred Reporting items for Systematic Reviews and Meta-analyses guidelines, 108 studies were reviewed, and 6 (5.6%) were included in the meta-analysis. REVIEW METHOD: The data on study and patient characteristics, surgical outcomes, and audiological test results were extracted from each article. Meta-analysis employed the fixed-effect and random-effects models to analyze the mean differences (MDs) between pre- and postoperative performances. RESULTS: In total, 116 patients were evaluated, including 64 (55%) adult and 52 (45%) pediatric patients. No intraoperative adverse events were reported, while postoperative complications were reported in 2 (3.1%) adult and 2 (3.8%) pediatric patients. Studies consistently showed significant improvements in audiological outcomes, quality of life, and sound localization in the aided condition. In the meta-analysis, we observed a significant difference in the unaided compared to the aided condition in sound field thresholds (n = 112; MD, -27.05 dB; P < 0.01), signal-to-noise ratio (n = 96; MD, -6.35 dB; P < 0.01), and word recognition scores (n = 96; MD, 68.89%; P < 0.01). CONCLUSION: The implantation of the BCI 602 was associated with minimal surgical complications and excellent audiological outcomes for both the pediatric and the adult cohort. Therefore, our analysis indicates a high level of safety and reliability. Further research should focus on direct comparisons with other BCIs and long-term functional outcomes.

2.
Otolaryngol Head Neck Surg ; 170(3): 795-803, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37943865

RESUMEN

OBJECTIVE: Extreme weather events are becoming more prevalent with the increasing pace of climate change. These events negatively impact human health and put considerable strain on health care resources, including emergency departments. Within otolaryngology, acute pharyngitis is a common reason for emergency room visits (ERV). Therefore, we aimed to investigate the impact of extreme meteorological conditions on ERV rates related to acute pharyngitis. STUDY DESIGN: Retrospective time-series study. SETTING: ERVs related to acute pharyngitis (n = 1511) were identified at a tertiary care hospital in Vienna, Austria, between 2015 and 2018. METHODS: The effects of single-day and prolonged (3-day) extreme weather events on ERVs were analyzed using a distributed lag nonlinear model. Relative risk (RR) and cumulative relative risk (cRR) were calculated over a lag period of 14 days. RR refers to the risk for pharyngitis-related ERV at extreme conditions (1st, 5th, 95th, or 99th percentile) compared to the risk at median conditions. RESULTS: Same-day RR (lag0) was elevated more than 3-fold after prolonged extremely low mean temperatures (P = .028). Furthermore, same-day RR after single-day and prolonged extremely high relative humidity was elevated by 51% (P = .024) and 46% (P = .036), respectively. Significant delayed effects on cRR were observed for extreme mean temperatures, relative humidity, and mean wind speeds within 8 days and for extreme atmospheric pressure within 14 days. CONCLUSION: Extreme weather events impact ERV rates for acute pharyngitis. Extremely low temperatures, high relative humidity, high atmospheric pressure, and low and high wind speeds were risk-promoting factors.


Asunto(s)
Clima Extremo , Faringitis , Humanos , Estudios Retrospectivos , Servicio de Urgencia en Hospital , Factores de Riesgo , Faringitis/diagnóstico , Faringitis/epidemiología
3.
Eur Arch Otorhinolaryngol ; 281(5): 2353-2363, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38133806

RESUMEN

PURPOSE: This multicentric, retrospective study aimed to analyze the short-term safety and effectiveness of the mCLIP Partial Prosthesis. METHODS: Patients underwent tympanoplasty with implantation of a mCLIP Partial Prosthesis. Follow-up examination included ear microscopy and pure-tone audiometry to determine the post-operative pure tone average of the frequencies 0.5, 1, 2 and 3 kHz (PTA4). The post-operative PTA4 air bone gap (ABG) was used to evaluate the audiological outcome. A post-operative minimum and maximum follow-up period was not defined. Thus, the follow-up times of each study center were different, which resulted in different follow-up times for the audiological analysis and for adverse events (AE). RESULTS: 72 (66 adults, 6 children) patients were implanted with the mCLIP Partial Prosthesis. 68 (62 adults, 6 children) patients underwent audiological examination; all 72 patients were examined for adverse events. All patients (N = 68): 72.1% of the patients showed a PTA4 ABG of ≤ 20 dB. Individual post-operative bone conduction (BC) PTA4 thresholds were stable in 67 patients. The mean post-operative follow-up time was 78 ± 46 days. Children (N = 6): 5 out of 6 children showed a PTA4 ABG of ≤ 20 dB. None of the children reported a BC PTA4 deterioration of > 10 dB HL after the implantation. The mean post-operative follow-up time was 101 ± 45 days. Adverse events (all patients, N = 72): 15 (14 adults, 1 child) patients had AEs (27 AEs and 2 Follow-Ups). The mean post-operative follow-up time was 375 days. CONCLUSION: Clinical data show satisfactory audiological parameters after implantation of the mCLIP Partial Prosthesis. The prosthesis is safe and effective for implantation in children and adults. TRIAL REGISTRATION NUMBER: NCT05565339, 09 September 2022, retrospectively registered.


Asunto(s)
Prótesis Osicular , Adulto , Niño , Humanos , Resultado del Tratamiento , Estudios Retrospectivos , Estudios de Seguimiento , Implantación de Prótesis , Conducción Ósea , Audiometría de Tonos Puros
4.
Front Public Health ; 11: 1153111, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37325328

RESUMEN

Background: Climate change has been associated with a higher frequency of extreme weather events, resulting in an overall increase in morbidity and mortality. Acute otitis media (AOM) is one of the most common otolaryngological infections and accounts for 1.5% of emergency department visits. This study aimed to identify associations between extreme weather events and the immediate and delayed risks for AOM-related emergency department visits (EV). Methods: A total of 1,465 AOM-related EVs were identified in the Vienna General Hospital between 2015 and 2018. A distributed lag non-linear model was applied to evaluate the relationship between extreme weather conditions and the total number of AOM-related EVs per day. The relative risk (RR) and cumulative RR (cRR) of single-day events and extended weather events over three days were analyzed over a lag period of 14 days. Results: AOM-related EVs showed a pronounced seasonality, with the highest occurrence during winter. Single-day weather events affected AOM-related EVs only at high relative humidity. Prolonged extreme weather conditions over three days, however, significantly increased the cRR for AOM-related EVs to 3.15 [1.26-7.88; p = 0.014] and 2.14 [1.14-4.04; p = 0.018] at mean temperatures of -4°C (1st-percentile - p1) and 0°C (p5) on the same day. Relative humidity of 37% (p1) decreased RR to 0.94 [0.88-0.99; p = 0.032] on day 7, while extremely high humidity of 89% (p99) led to an increased cRR of 1.43 [1.03-2.00; p = 0.034] on day 7. Heavy prolonged precipitation of 24mm (p95) reduced cRR beginning day 4 up until day 14 to 0.52 [0.31-0.86; p = 0.012]. Prolonged low atmospheric pressure events of 985hPa (p5) reduced the RR to 0.95 [0.91-1.00; p = 0.03], whereas extremely high atmospheric pressure events of 1013hPa (p99) increased the RR to 1.11 [1.03-1.20; p = 0.008]. Extremely low wind speeds significantly diminished the RR of AOM-related EVs. Conclusions: While single-day extreme weather events had little impact on the occurrence of AOM-related EVs, extended periods of extreme temperatures, relative humidity, precipitation, wind speeds and atmospheric pressure significantly impacted the RR for AOM-related EVs. These findings could help improve healthcare resource allocation in similar climates and aid in educating patients about the role of environmental factors in AOM.


Asunto(s)
Otitis Media , Tiempo (Meteorología) , Humanos , Temperatura , Estaciones del Año , Otitis Media/epidemiología , Servicio de Urgencia en Hospital
5.
Otolaryngol Head Neck Surg ; 168(6): 1502-1510, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36856581

RESUMEN

OBJECTIVE: Electrically evoked auditory brainstem response audiometry has emerged as a suitable option to intraoperatively assess cochlear nerve function during vestibular schwannoma resection. This study aimed to analyze the functional outcome and implant usage of patients with preserved auditory nerve responses after simultaneous translabyrinthine schwannoma resection and cochlear implantation. STUDY DESIGN: Prospective study. SETTING: Tertiary referral center. METHODS: Patients with unilateral sporadic vestibular schwannoma underwent translabyrinthine tumor resection. Intraoperatively, electrically evoked auditory brainstem response audiometry was performed before and after tumor removal. Cochlear implantation was carried out if positive responses were detected after tumor removal indicating cochlear nerve function. Postoperatively, patients were biannually followed-up to assess aided sound field audiometry and word recognition as well as implant usage. RESULTS: Overall, 26 patients with vestibular schwannoma underwent translabyrinthine schwannoma resection. Out of these patients, 15 had positive cochlear nerve responses after tumor removal and concurrently received a cochlear implant. In 13 patients with histologically confirmed vestibular schwannoma, hearing improved by 23.7 ± 33.2 decibels and word recognition by 25.0 ± 42.4% over a mean follow-up period of 18 months. Overall, 12 included patients were regular cochlear implant users. CONCLUSION: Patients with vestibular schwannoma can benefit substantially from cochlear implantation. Intraoperative assessment of cochlear nerve function using electrically evoked auditory brainstem response audiometry can help to better identify individuals eligible for simultaneous vestibular schwannoma resection and cochlear implantation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Neuroma Acústico , Humanos , Neuroma Acústico/cirugía , Estudios Prospectivos , Cóclea/patología , Nervio Coclear/patología , Nervio Coclear/cirugía , Resultado del Tratamiento , Estudios Retrospectivos
6.
Eur Arch Otorhinolaryngol ; 280(9): 3997-4007, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36856808

RESUMEN

PURPOSE: Extreme weather events are rising due to the accelerating pace of climate change. These events impact human health and increase emergency room visits (EV) for many morbidities. Tinnitus is a common cause of EVs within otolaryngology in Germany and Austria. The effect of extreme weather conditions on tinnitus-related EVs is unknown. METHODS: A total of 526 tinnitus-related EVs at a tertiary care hospital in Vienna were identified. A distributed lag non-linear model with a maximum lag period of 14 days was fitted to investigate the immediate and delayed effect of single-day and prolonged (three-day) extreme atmospheric pressure, relative humidity, mean temperature, precipitation and mean wind speed on EV rates. Extreme conditions were defined as the 1st, 5th, 95th, and 99th percentile of the meteorological variables. Relative risk (RR) is defined as risk for tinnitus-related EVs at an extreme condition compared to the risk at the median weather condition. Cumulative RR (cRR) is the total cumulated EV risk for a given time period. RESULTS: High relative humidity increased same-day RR for tinnitus-related EVs to 1.75. Both low and high atmospheric pressure raised cRR as early as three days after an event to a maximum of 3.24. Low temperatures mitigated cRR within 4 days, while high temperatures tended to increase risk. Prolonged precipitation reduced cRR within one day. CONCLUSION: Extreme meteorological conditions are associated with tinnitus-related EV rates. Further investigation into potential causative links and underlying pathophysiological mechanisms is warranted.


Asunto(s)
Acúfeno , Humanos , Acúfeno/epidemiología , Tiempo (Meteorología) , Frío , Temperatura , Servicio de Urgencia en Hospital
7.
Otolaryngol Head Neck Surg ; 169(3): 615-621, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36939484

RESUMEN

OBJECTIVE: Recently, the Bonebridge 602 implant was introduced. Its smaller dimensions facilitate implantation even in surgically demanding cases. However, in extreme anatomical conditions, implant lifts are still required. We intended to report on the medical and audiological outcomes of all patients implanted with the implant with a secondary focus on the safety, efficacy, and feasibility of the use of 1-mm lifts. STUDY DESIGN: Retrospective cohort study. SETTING: Tertiary academic center. METHODS: We retrospectively analyzed all patients implanted with the Bonebridge 602. Patient demographics and surgically-specific data were collected from the medical charts. Furthermore, audiological results were assessed. Outcomes were compared between implantations with versus without lifts. RESULTS: Twenty-one devices were implanted during the study period. Satisfactory audiological results were observed, while no intra- or postoperative adverse events occurred. The majority of patients were daily users at the end of the observation period (n = 20/21, 95.2%), and one patient (n = 1/21, 4.8%) was a nonuser after 6 months of use because of subjective dissatisfaction. Due to anatomical considerations, 1-mm lifts were used in 4 implantations (19.0%). The application of lifts did not result in prolonged surgical times, complications, or shorter time of use, nor did it negatively affect audiometric results. CONCLUSION: Implantations with the new and smaller Bonebridge were associated with gratifying medical and audiological outcomes. Still, in extreme anatomical conditions, 1-mm lifts are necessary. Nonetheless, surgical placement with the help of lifts seems safe, effective, and feasible, and is a viable option in cases with challenging anatomies due to previous surgeries or anomalies.


Asunto(s)
Audífonos , Prótesis e Implantes , Humanos , Estudios Retrospectivos , Prótesis e Implantes/efectos adversos , Conducción Ósea , Implantación de Prótesis/métodos , Audiometría , Audífonos/efectos adversos , Pérdida Auditiva Conductiva/cirugía , Resultado del Tratamiento
8.
Ear Hear ; 44(1): 146-154, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35925830

RESUMEN

BACKGROUND: Stimulation with triphasic pulses has been shown to reduce the occurrence of unwanted facial nerve stimulation (FNS) with cochlear implants (CIs). However, there is little data available on how different pulse shapes affect the hearing outcome with electrical hearing in general. The aim of the study was to evaluate the effects of different stimulation pulse shapes on speech perception in noise, as well as loudness perception and subjective sound quality. METHODS: Twenty experienced cochlear-implant users not suffering from FNS participated in a prospective single-visit study. Based on the subjects' current clinical fitting, six fitting maps with different pulse shapes (biphasic and triphasic) and different interphase gap (IPG) durations (2.1 µs, 10 µs, and 20 µs) were created. First, the loudness was balanced for each configuration by adjusting the stimulation charge amount. Then, speech perception in noise was measured with a German matrix sentence test (Oldenburg Sentence test). The perception of particular sound attributes of speech and music, as well as overall preference, was evaluated with visual analog scales. RESULTS: Similar levels of speech perception were obtained with triphasic stimulation ( P = 0.891) and longer IPGs ( P = 0.361) compared to the subjects' clinical map settings. The stimulation amplitudes for equal loudness were significantly higher with triphasic stimulation compared to biphasic stimulation when keeping the IPG constant. Increasing the IPG had a significantly larger effect on perceived loudness ( P < 0.0001) and charge reduction for equal loudness with triphasic pulses compared to biphasic pulses. Triphasic configuration showed lower overall subjective sound quality ratings than biphasic for speech intelligibility, clarity, naturalness, and overall preference, as well as for music naturalness, and overall preference in the acute setting without adaptation time. Post-hoc pairwise comparisons against the clinical map revealed significantly lower speech naturalness ratings for triphasic with 2.1 µs IPG and for triphasic with 20 µs IPG only. CONCLUSION: Although some sound quality attributes were rated lower compared to the clinical map in the acute test setting, stimulation with triphasic pulses does not affect speech perception in noise and can be considered as a valuable option in CI fitting.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Humanos , Percepción del Habla/fisiología , Estudios Prospectivos , Estimulación Eléctrica , Audición
10.
J Pers Med ; 12(2)2022 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-35207679

RESUMEN

Less than 20% of patients with sensorineural hearing loss (HL) provided with the Vibrant Soundbridge (VSB) experience a progressive HL and warrant cochlear implantation (CI). The aim of this study was to identify possible predictors of progressive HL prior to VSB implantation. This retrospective study included all consecutive ears with sensorineural HL provided with the VSB between 1998 and 2016. The patient cohort was divided in a study group comprising patients who underwent CI (CI group) after years of VSB usage and those who did not require VSB replacement during the observational time (control group). Pre- and postoperative pure-tone audiometry thresholds were compared among the two groups. Fifteen out of 81 VSB devices (18.5%) required a CI. The CI group had higher preoperative air-conduction (AC) thresholds than the control group (64.3 ± 8.9 dB vs. 56.3 ± 12.9 dB; p = 0.007) at the time of the VSB implantation. On average, the CI group was significantly younger (39.1 ± 12.3 years vs. 52.6 ± 16.2 years; p = 0.003). In conclusion, VSB users with higher preoperative AC thresholds and younger age at the time of VSB implantation might be at risk for progressive HL within the upcoming eight years and need a further CI surgery. Preoperative counseling is particularly advisable in this patient group.

11.
Eur J Pharm Biopharm ; 170: 52-58, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34864199

RESUMEN

Intratympanically applied treatments are of increasing interest to the otologic community to treat sudden sensorineural hearing loss or vestibular disorders but also to deliver gene therapy agents, or biologics to the inner ear. Further diversion from the middle ear and perilymph to blood circulation and cerebrospinal fluid via the cochlear aqueduct are one of the limiting factors and so far not understood well enough. In this study, intratympanically applied triamcinolone acetonide was determined in cerebrospinal fluid. Additionally, perilymph was sampled through the round window membrane as well as at the lateral semicircular canal to determine drug levels. Of the twenty-one included patients, triamcinolone acetonide was quantifiable in cerebrospinal fluid in 43% at very low levels (range 0 ng/ml-6.2 ng/ml) which did not correlate with perilymph levels. Drug levels at the two different perilymph sampling sites were within a range of 13.5 ng/ml to 1180.0 ng/ml. Results suggest an equal distribution of triamcinolone acetonide to semicircular canals, which might support the use of triamcinolone acetonide as a treatment option for vestibular pathologies such as Menièrés disease. On the other hand, the distribution to cerebrospinal fluid might be limiting current approaches in gene therapy where a central distribution is unwanted.


Asunto(s)
Líquido Cefalorraquídeo/metabolismo , Glucocorticoides/administración & dosificación , Neuroma Acústico/tratamiento farmacológico , Triamcinolona Acetonida/administración & dosificación , Femenino , Humanos , Inyección Intratimpánica , Masculino , Persona de Mediana Edad , Perilinfa/metabolismo
12.
J Voice ; 36(1): 98-105, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32439216

RESUMEN

OBJECTIVES: Acute laryngitis is a common disease with self-limiting nature. Since the leading cause is attributed to viral infections and thus self-limiting, many affected individuals do not seek professional medical help. However, because the major symptom of hoarseness imposes a substantial burden in everyday life, it might be speculated that web-based search interest on this condition follows incidence rates, with highest peaks during winter months. The aim of this study was to evaluate global public health-information seeking behaviour on laryngitis-related search terms. METHODS: We utilized Google Trends to assess country-specific, representative laryngitis-related search terms for English and non-English speaking countries of both hemispheres. Extracted time series data from Australia, Brazil, Canada, Germany, the United Kingdom, and the United States of America, covering a timeframe between 2004 and 2019 were first assessed for reliability, followed by seasonality analysis using the cosinor model. RESULTS: Direct comparisons revealed different, representative laryngitis-related search terms for English- and non-English speaking countries. Extracted data showed a trend of higher reliability in countries with more inhabitants. Subsequent graphical analysis revealed winter peaks in all countries from both hemispheres. Cosinor analysis confirmed these seasonal variations to be significant (all P < 0.001). CONCLUSION: Public interest in laryngitis-related, online health information displayed seasonal variations in countries from both hemispheres, with highest interest during winter months. These findings emphasize the importance to optimize the distribution of reliable, web-based health education in order to prevent the spread of misinformation and to improve health literacy among general populations.


Asunto(s)
Laringitis , Alemania , Humanos , Infodemiología , Internet , Laringitis/diagnóstico , Laringitis/epidemiología , Reproducibilidad de los Resultados , Estaciones del Año , Estados Unidos
13.
Front Surg ; 8: 742219, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34660683

RESUMEN

Background: Robotic surgery has been proposed in various surgical fields to reduce recovery time, scarring, and to improve patients' outcomes. Such innovations are ever-growing and have now reached the field of cochlear implantation. To implement robotic ear surgery in routine, it is of interest if preoperative planning of a safe trajectory to the middle ear is possible with clinically available image data. Methods: We evaluated the feasibility of robotic cochlear implant surgery in 50 patients (100 ears) scheduled for routine cochlear implant procedures based on clinically available imaging. The primary objective was to assess if available high-resolution computed tomography or cone beam tomography imaging is sufficient for planning a trajectory by an otological software. Secondary objectives were to assess the feasibility of cochlear implant surgery with a drill bit diameter of 1.8 mm, which is the currently used as a standard drill bit. Furthermore, it was evaluated if feasibility of robotic surgery could be increased when using smaller drill bit sizes. Cochlear and trajectory parameters of successfully planned ears were collected. Measurements were carried out by two observers and the interrater reliability was assessed using Cohen's Kappa. Results: Under the prerequisite of the available image data being sufficient for the planning of the procedure, up to two thirds of ears were eligible for robotic cochlear implant surgery with the standard drill bit size of 1.8 mm. The main reason for inability to plan the keyhole access was insufficient image resolution causing anatomical landmarks not being accurately identified. Although currently not applicable in robotic cochlear implantation, narrower drill bit sizes ranging from 1.0 to 1.7 mm in diameter could increase feasibility up to 100%. The interrater agreement between the two observers was good for this data set. Discussion: For robotic cochlear implant surgery, imaging with sufficient resolution is essential for preoperative assessment. A slice thickness of <0.3 mm is necessary for trajectory planning. This can be achieved by using digital volume tomography while radiation exposure can be kept to a minimum. Furthermore, surgeons who use the software tool, should be trained on a regular basis in order to achieve planning consistency.

14.
JAMA Otolaryngol Head Neck Surg ; 147(11): 974-980, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34591079

RESUMEN

Importance: The use of intratympanically applied steroids is of increasing interest. Consequently, research has focused on finding an ideal drug that diffuses through the round window membrane and can be retained in the perilymph. Objective: To compare levels of triamcinolone acetonide (TAC) in perilymph and plasma after intratympanic injection. Design, Setting, and Participants: This randomized clinical trial included 40 patients receiving cochlear implants at a single tertiary care center in Vienna, Austria. Patients were randomized to 1 of 4 treatment groups receiving 1 of 2 intratympanic doses of TAC (10 mg/mL or 40 mg/mL) at 1 of 2 approximate time points (24 hours or 1 hour) before sampling the perilymph. Inclusion was carried out between November 2017 and January 2020, and data were analyzed in December 2020. Interventions: All patients underwent intratympanic injection of TAC. During cochlear implantation, perilymph and plasma were sampled for further analysis. Main Outcomes and Measures: Levels of TAC measured in perilymph and plasma. Results: Among the 37 patients (median [range] age, 57 [26-88] years; 18 [49%] men) included in the analysis, TAC was present at a median (range) level of 796.0 (46.4-7706.7) ng/mL. In the majority of patients (n = 29; 78%), no drug was detectable in the plasma after intratympanic injection. Levels above the limit of detection were less than 2.5 ng/mL. The 1-factorial analysis of variance model showed lower TAC levels in the group that received TAC, 10 mg/mL, 24 hours before surgery (median, 271 ng/mL) compared with the group that received TAC, 10 mg/mL, 1 hour before surgery (median, 2877 ng/mL), as well as in comparison with the groups receiving TAC, 40 mg/mL, 24 hours before surgery (median, 2150 ng/mL) and 1 hour before surgery (median, 939 ng/mL). The 2-factorial analysis of variance model showed lower TAC levels in the group receiving TAC, 10 mg/mL, 24 hours before surgery than the group receiving TAC, 10 mg/mL, 1 hour before surgery, and higher TAC levels in the group receiving TAC, 40 mg/mL, 24 hours before surgery compared with the group receiving TAC, 10 mg/mL, 24 hours before surgery. Patients with thickening of the middle ear had statistically significantly higher plasma levels (median, 1.4 ng/mL vs 0 ng/mL) and lower perilymph levels (median, 213.1 ng/mL vs 904 ng/mL) than individuals with unremarkable middle ear mucosa. Conclusions and Relevance: In this randomized clinical trial, TAC was shown to be a promising drug for intratympanic therapies, with similar levels in perilymph 1 hour and 24 hours after injection (distinctly in the groups receiving the 40 mg/mL dose). There was also minimal dissemination to the plasma, especially in patients with unremarkable middle ear mucosa. Trial Registration: ClinicalTrials.gov Identifier: NCT03248856.


Asunto(s)
Antiinflamatorios/farmacocinética , Implantación Coclear , Perilinfa/química , Cuidados Preoperatorios/métodos , Triamcinolona Acetonida/farmacocinética , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Antiinflamatorios/administración & dosificación , Antiinflamatorios/metabolismo , Esquema de Medicación , Femenino , Humanos , Inyección Intratimpánica , Masculino , Persona de Mediana Edad , Triamcinolona Acetonida/administración & dosificación , Triamcinolona Acetonida/metabolismo , Adulto Joven
15.
J Am Acad Audiol ; 32(5): 290-294, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-34062601

RESUMEN

BACKGROUND: Implant lifts were recently introduced to facilitate implantation of the Bonebridge and to reduce the risk of uncovering the sigmoid sinus and/or dura. PURPOSE: The current study analyzed medical, technical, and audiological outcomes of implantation with the Bonebridge implant using lifts. RESEARCH DESIGN: This was a retrospective study on all consecutive patients implanted with a bone-conduction hearing implant at a tertiary medical referral center between March 2012 and October 2018. Outcome measures were complications, explantations, and revisions and the mean time of implant use. Audiological results were assessed as well. Outcomes were evaluated for devices implanted with BCI Lifts and compared with those implanted without lifts. RESULTS: In the study period, 13 out of a total of 54 implantations were conducted using one or two 1- to 4-mm BCI Lifts. During the follow-up period, two complications occurred and both in patients implanted without lifts (2/41; 4.9%). All patients in the lifts group were using the implant at the end of observation period. No statistically significant difference was observed in functional hearing gain or word-recognition improvement at 65 dB between two groups. CONCLUSIONS: The use of BCI Lifts in Bonebridge implantations was not associated with adverse events during the observation period. The clinical follow-up revealed no complications in implantations requiring lifts. Furthermore, the functional hearing gain and the word-recognition improvement did not differ from those of devices implanted without lifts. Data indicate safety and efficacy for Bonebridge implantations using lifts.


Asunto(s)
Audífonos , Conducción Ósea , Audición , Audífonos/efectos adversos , Pérdida Auditiva Conductiva , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
16.
J Med Internet Res ; 23(6): e28328, 2021 06 24.
Artículo en Inglés | MEDLINE | ID: mdl-34185016

RESUMEN

BACKGROUND: The data retrieved with the online search engine, Google Trends, can summarize internet inquiries into specified search terms. This engine may be used for analyzing inquiry peaks for different medical conditions and symptoms. OBJECTIVE: The aim of this study was to analyze World Wide Web interest peaks for "ear pain," "ear infection," and "ear drops." METHODS: We used Google Trends to assess the public online interest for search terms "ear pain," "ear infection," and "ear drops" in 5 English and non-English-speaking countries from both hemispheres based on time series data. We performed our analysis for the time frame between January 1, 2004, and December 31, 2019. First, we assessed whether our search terms were most relevant to the topics of ear pain, ear infection, and ear drops. We then tested the reliability of Google Trends time series data using the intraclass correlation coefficient. In a second step, we computed univariate time series plots to depict peaks in web-based interest. In the last step, we used the cosinor analysis to test the statistical significance of seasonal interest peaks. RESULTS: In the first part of the study, it was revealed that "ear infection," "ear pain," and "ear drops" were the most relevant search terms in the noted time frame. Next, the intraclass correlation analysis showed a moderate to excellent reliability for all 5 countries' 3 primary search terms. The subsequent analysis revealed winter interest peaks for "ear infection" and "ear pain". On the other hand, the World Wide Web search for "ear drops" peaked annually during the summer months. All peaks were statistically significant as revealed by the cosinor model (all P values <.001). CONCLUSIONS: It can be concluded that individuals affected by otitis media or externa, possibly the majority, look for medical information online. Therefore, there is a need for accurate and easily accessible information on these conditions in the World Wide Web, particularly on differentiating signs and therapy options. Meeting this need may facilitate timely diagnosis, proper therapy, and eventual circumvention of potentially life-threatening complications.


Asunto(s)
Dolor , Motor de Búsqueda , Humanos , Internet , Reproducibilidad de los Resultados , Estaciones del Año
17.
Otol Neurotol ; 42(6): 858-866, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33989254

RESUMEN

OBJECTIVE: Investigation of long-term safety and performance of an active, transcutaneous bone conduction implant in adults and children up to 36 months post-implantation. STUDY DESIGN: Prospective, single-subject repeated-measures design. SETTING: Otolaryngology departments of eight German and Austrian hospitals.∗†‡§||¶#∗∗†† Affiliations listed above that did not participate in the study.‡‡§§||||¶¶. PATIENTS: Fifty seven German-speaking patients (49 adults and eight children) suffering from conductive or mixed hearing loss, with an upper bone conduction threshold limit of 45 dB HL at frequencies between 500 and 3000 Hz. INTERVENTION: Implantation of the Bonebridge transcutaneous bone conduction hearing implant (tBCI). MAIN OUTCOME MEASURES: Patients' audiometric pure tone averages (PTA4) (0.5, 1, 2, 4 kHz) thresholds (air conduction, bone conduction, and sound field) and speech perception (word recognition scores [WRS] and speech reception thresholds [SRT50%]) were tested preoperatively and up to 36 months postoperatively. Patients were also monitored for adverse events and administered quality-of-life questionnaires. RESULTS: Speech perception (WRS: pre-op: 17.60%, initial activation [IA]: 74.23%, 3M: 83.65%, 12M: 83.46%, 24M: 84.23%, 36M: 84.42%; SRT50%: pre-op: 65.56 dB SPL, IA: 47.67 dB SPL, 3M: 42.61 dB SPL, 12M: 41.11 dB SPL, 24M: 41.74 dB SPL, 36M: 42.43 dB SPL) and sound field thresholds (pre-op: 57.66 dB HL, IA: 33.82 dB HL, 3M: 29.86 dB HL, 12M: 28.40 dB HL, 24M: 28.22 dB HL, 36M: 28.52 dB HL) improved significantly at all aided postoperative visits. Air and bone conduction thresholds showed no significant changes, confirming preservation of patients' residual unaided hearing. All adverse events were resolved by the end of the study. CONCLUSIONS: Safety and performance of the tBCI was demonstrated in children and adults 36 months postoperatively.


Asunto(s)
Audífonos , Percepción del Habla , Adulto , Umbral Auditivo , Conducción Ósea , Niño , Audición , Pérdida Auditiva Conductiva/cirugía , Pruebas Auditivas , Humanos , Estudios Prospectivos , Resultado del Tratamiento
18.
Life (Basel) ; 11(2)2021 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-33671447

RESUMEN

Objective: The aim of this study was to evaluate whether stapes prostheses can be visualized with less metal artifacts and therefore more accurately on cone beam computed tomography in comparison to computed tomography imaging. Recent studies have shown that cone beam computed tomography has advantages when imaging metal artifacts. Patients with hearing loss or vertigo, who have undergone stapedotomy, often present a challenge for otologic surgeons. Imaging studies can deliver crucial additional information. Methods: A retrospective analysis of imaging studies and clinical data in a tertiary care center were carried out. Forty-one patients with forty-five implanted ears were evaluated in the study. All included patients had been implanted with a platinum-fluoroplastic (n = 19) or titanium (n = 26) piston and subsequently had undergone imaging months or years after surgery for various reasons. Patients underwent computed tomography or cone beam computed tomography of the temporal bone depending on availability. Piston visualization, prosthesis length, vestibular intrusion and audiologic results were compared between the groups. Piston position on imaging studies were compared to intraoperative findings. Results: Functional length measurements of all prostheses were carried out with a mean error of -0.17 mm (±0.20). Platinum-fluoroplastic protheses were significantly underestimated in length compared to titanium prostheses. To analyze the material-dependent difference in the measurement errors of the imaging techniques the interaction was tested in an ANOVA model and showed no statistically significant result (p = 0.24). The blinded neuroradiologist viewed two implants, both platinum-fluoroplastic pistons, as located outside of the vestibule due to an underestimation of the prothesis length and the missing radiodensity of the lower end of the prosthesis. Conclusion: Surgeons and radiologists should be aware of the different types and radiologic features of stapes prostheses and the missing radiodensity of some protheses parts. Cone beam computed tomography is an imaging alternative with a potential advantage of reduced radiation in patients after stapes surgery suffering from vertigo or hearing loss to evaluate piston position.

19.
PLoS One ; 16(2): e0247451, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33621252

RESUMEN

BACKGROUND: The aim of this study was to evaluate whether surgeons´ experience and perioperative single-shot antibiotic prophylaxis affect outcome of patients undergoing stapes surgery. PATIENTS AND METHODS: We retrospectively evaluated audiological outcomes and postoperative complications of 538 consecutive patients who underwent stapes surgery at a single tertiary referral center between 1990 and 2017. Effects of different clinical variables, including single-shot antibiotic prophylaxis and surgeons' experience on outcome were assessed. RESULTS: 538 patients underwent 667 stapedotomies and postoperative complication rate was 7.5% (n = 50). Air conduction and air-bone gap closure improved significantly after surgery (14.2 ± 14.8 dB, p = 0.001; 14.5 ± 12.8 dB, p = 0.001). Multivariate analysis revealed that 6 years or less of surgical experience was independently associated with a higher incidence of persisting or recurrent conductive hearing loss (p = 0.033, OR 5.13) but perioperative application of antibiotics had no significant effect on outcome. CONCLUSION: First, clinical outcome regarding persisting or recurrent conductive hearing loss caused by incus necrosis and prosthesis luxation is linked to surgical performance. This underlines the need for a meticulous training and supervision of less experienced surgeons performing stapes surgery. Second, our results do not support the need for perioperative antibiotic prophylaxis in stapes surgery. Potential standard limitations of retrospective cohort studies (selection bias, confusion bias etc.) could play a role in interpreting our results. However, the probability for these limitations is minimized due to the large patient sample.


Asunto(s)
Profilaxis Antibiótica/métodos , Competencia Clínica , Otosclerosis/cirugía , Complicaciones Posoperatorias/epidemiología , Cirugía del Estribo/efectos adversos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Profilaxis Antibiótica/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Atención Perioperativa , Estudios Retrospectivos , Cirujanos , Centros de Atención Terciaria , Adulto Joven
20.
Otol Neurotol ; 42(4): 510-516, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33443975

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the performance and limits of an adhesive bone conduction hearing aid in patients implanted with an active transcutaneous bone conduction implant. Therefore, hearing performance and subjective benefit of patients with mixed and conductive hearing loss were assessed with both bone conduction devices. STUDY DESIGN AND PATIENTS: This cohort study was conducted at a tertiary care center. Fifteen subjects, who had been implanted with an active transcutaneous device previously, were included and used the adhesive hearing device for 3 weeks instead of the implant. Subjects underwent two sets of audiological tests as well as assessments of quality of life at the beginning and at the end of the testing period. RESULTS: Audiological results showed a significantly greater improvement in regards to functional hearing gain and word recognition scores with the transcutaneous bone conduction device than the nonimplantable adhesive device. Regression analysis showed a trend toward greater improvement with the transcutaneous device compared with the adhesive device in patients with an increasing bone conduction threshold. Hearing-specific and general quality-of-life questionnaires revealed no significant difference between the two devices. CONCLUSION: Patients with mixed or conductive hearing loss experience hearing gain with both, the adhesive device and the active transcutaneous device. The adhesive device may be a valuable alternative to the active transcutaneous device, depending on the individual bone conduction threshold.


Asunto(s)
Audífonos , Perdida Auditiva Conductiva-Sensorineural Mixta , Percepción del Habla , Adhesivos , Conducción Ósea , Estudios de Cohortes , Pérdida Auditiva Conductiva , Humanos , Calidad de Vida , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...