Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Ophthalmol ; 17: 1007-1011, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37035515

RESUMEN

Purpose: We describe the ocular and periocular clinical features in patients with a facial palsy diagnosis of any etiology and to report the demographics, relevant medical history and treatment modalities in these patients. Patients and Methods: Retrospective and descriptive observational study. A total of 60 patients with a facial palsy diagnosis in the last 5 years were recruited from an ophthalmological clinic in northeastern Mexico. Demographic data, such as age, sex, disease evolution and etiology, visual acuity, ocular symptoms and ocular and periocular clinical features were obtained. Personal history of previous ophthalmologic surgery, as well as ocular and systemic diseases, were also recorded. Finally, a comparative analysis was done to determine association between signs, symptoms and treatment modalities. Results: A prevalence of 0.14% was reported, 56.7% of patients were female, and mean age of presentation was 55.63±17.2 years. 76.7% of facial palsy was idiopathic in origin, followed by vascular disease in 8.30% and iatrogenic in 6.70%. 40% of patients had a history of arterial hypertension, 36.3% were diabetic, and 6.70% had cerebrovascular disease. Conclusion: Early diagnosis of facial palsy is crucial in establishing an effective treatment plan and avoiding complications. The impact of this disease in patients' quality of life cannot be overlooked, and steps should be taken to address the different impairments that this ailment entails.

2.
Artículo en Inglés | MEDLINE | ID: mdl-36070804

RESUMEN

BACKGROUND/AIM: The importance of an accurate determination of central corneal thickness (CCT) relies on its diagnostic and therapeutic implications in glaucoma, corneal ectasias, corneal edema and endothelial function monitoring, and refractive surgery suitability, among others. We aimed to analyze the repeatability, reproducibility, correlation, and laterality variations of CCT measurements performed with the Pentacam HR and the standard of care ultrasound A-scan (USP). METHODS: A cross-sectional study including CCT measurements of healthy individuals was performed by three independent examiners with the Pentacam HR and USP. Intra-observer and inter-observer variations were calculated with intra-class correlation coefficients (ICCs). Bland-Altman plots and 95% limits of agreement (95% LoA) were used to assess the agreement between devices. Linear correlation was calculated with Pearson's coefficient. RESULTS: Thirty individuals (60 eyes), including 10 (33.3%) men and 20 (66.6%) women, with a mean age of 30.0 ± 9.1 years, were studied. No statistical differences were found in CCT measurements between Pentacam HR (range 500 - 609 µm) and USP (range 498 - 628 µm). There was a high degree of correlation in repeatability and reproducibility of each independent device (ICC > 0.90). Pearson's correlation between 1 vs. 2, 2 vs. 3, and 3 vs. 1 Pentacam HR attempts were 0.914, 0.958, and 0.925, respectively (p < 0.001). Corresponding results for USP were 0.957, 0.957, and 0.943 (p < 0.001). The Pentacam HR tended to overestimate CCT by a mean difference of 3.77 µm (95% LoA, - 24.9 - 18.4). Right eyes were also overestimated (- 3.6 ± 14.1 µm) with the Pentacam HR device, whereas left eyes were underestimated (1.3 ± 11.1 µm). CONCLUSIONS: The Pentacam HR device provides reliable operator-independent estimates of CCT. Right eyes exhibited a tendency to overestimate with the Pentacam HR. We suspect this difference is due to USP underestimation related to patients' position while performing the study. In clinically relevant scenarios, performing a third measurement and cautiously measuring right eyes can provide higher accuracy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...