Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Clin Sleep Med ; 16(10): 1711-1719, 2020 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-32621579

RESUMEN

STUDY OBJECTIVES: Different therapeutic strategies have been investigated for the treatment of positional obstructive sleep apnea, but more evidence is needed about efficacy and compliance. The objective of this study was to describe the efficacy of vibrotactile neck-based treatment in patients with positional obstructive sleep apnea with different degrees of obstructive sleep apnea severity who were followed for 6 months. METHODS: This is a retrospective study including 162 patients with positional obstructive sleep apnea undergoing vibrotactile neck-based positional therapy. We compared polysomnographic data obtained at baseline and during positional therapy after 1 month. We performed a subgroup analysis based on obstructive sleep apnea severity. Furthermore, we analyzed follow-up data in 84/162 (51.8%) patients with particular focus on discontinuation and complications related to the device. RESULTS: We observed a significant difference between mean baseline obstructive apnea-hypopnea index (OAHI; 21.9 ± 9.9 events/h) and during positional therapy (12 ± 9.2 events/h; P < .01). Moreover, 87/162 (54.9%) patients showed a reduced baseline OAHI of at least 50% and 38/162 (23.4%) achieved complete disease control (OAHI < 5 events/h). At subgroup analysis, at least 50% reduction from baseline OAHI was observed in 56.8% of patients with mild, 55% with moderate, and 47.4% with severe OAHI, whereas complete control of disease was achieved in 50% of patients with mild, 22.5% with moderate, and 7.9% with severe OAHI. At a 6-month follow-up, only 35/84 patients (41.6%) were regularly using the device, with a mean of 5.9 ± 1.2 days per week. CONCLUSIONS: Our results on the efficacy and long-term adherence to vibrotactile neck-based positional therapy showed that positional therapy can be an efficient first-line treatment option for mild positional obstructive sleep apnea and in selected cases of moderate disease. Long-term compliance is limited because of complications and low satisfaction in some patients.


Asunto(s)
Apnea Obstructiva del Sueño , Estudios de Seguimiento , Humanos , Cuello , Polisomnografía , Estudios Retrospectivos , Apnea Obstructiva del Sueño/terapia
2.
Biomed Res Int ; 2015: 915185, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26636102

RESUMEN

RATIONALE: The gold standard for the diagnosis of Obstructive Sleep Apnea (OSA) is polysomnography, whose access is however reduced by costs and limited availability, so that additional diagnostic tests are needed. OBJECTIVES: To analyze the diagnostic accuracy of the Obstructive Airway Adult Test (OAAT) compared to polysomnography for the diagnosis of OSA in adult patients. METHODS: Ninety patients affected by OSA verified with polysomnography (AHI ≥ 5) and ten healthy patients, randomly selected, were included and all were interviewed by one blind examiner with OAAT questions. MEASUREMENTS AND MAIN RESULTS: The Spearman rho, evaluated to measure the correlation between OAAT and polysomnography, was 0.72 (p < 0.01). The area under the ROC curve (95% CI) was the parameter to evaluate the accuracy of the OAAT: it was 0.91 (0.81-1.00) for the diagnosis of OSA (AHI ≥ 5), 0.90 (0.82-0.98) for moderate OSA (AHI ≥ 15), and 0.84 (0.76-0.92) for severe OSA (AHI ≥ 30). CONCLUSIONS: The OAAT has shown a high correlation with polysomnography and also a high diagnostic accuracy for the diagnosis of OSA. It has also been shown to be able to discriminate among the different degrees of severity of OSA. Additional large studies aiming to validate this questionnaire as a screening or diagnostic test are needed.


Asunto(s)
Diagnóstico por Computador/métodos , Autoevaluación Diagnóstica , Polisomnografía/métodos , Índice de Severidad de la Enfermedad , Apnea Obstructiva del Sueño/diagnóstico , Encuestas y Cuestionarios , Adulto , Anciano , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA