Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Assoc Med Microbiol Infect Dis Can ; 7(3): 186-195, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36337598

RESUMEN

BACKGROUND: Serological assays designed to detect SARS-CoV-2 antibodies are being used in serological surveys and other specialized applications. As a result, and to ensure that the outcomes of serological testing meet high quality standards, evaluations are required to assess the performance of these assays and the proficiency of laboratories performing them. METHODS: A panel of 60 plasma/serum samples from blood donors who had reverse transcriptase-polymerase chain reaction (RT-PCR) confirmed SARS-CoV-2 infections and 21 SARS-CoV-2 negative samples were secured and distributed to interested laboratories within Canada (n = 30) and the United States (n = 1). Participating laboratories were asked to provide details on the diagnostic assays used, the platforms the assays were performed on, and the results obtained for each panel sample. Laboratories were blinded with respect to the expected outcomes. RESULTS: The performance of the different assays evaluated was excellent, with the high-throughput platforms of Roche, Ortho, and Siemens demonstrating 100% sensitivity. Most other high-throughput platforms had sensitivities of >93%, with the exception of the IgG assay using the Abbott ARCHITECT which had an average sensitivity of only 87%. The majority of the high-throughput platforms also demonstrated very good specificities (>97%). CONCLUSION: This proficiency study demonstrates that most of the SARS-CoV-2 serological assays utilized by provincial public health or hospital laboratories in Canada have acceptable sensitivity and excellent specificity.


HISTORIQUE: Les dosages sérologiques conçus pour dépister les anticorps anti-SRAS-CoV-2 sont utilisés dans les études sérologiques et d'autres applications spécialisées. Par conséquent, et pour s'assurer que leurs résultats respectent des normes de qualité, il faut procéder à des évaluations de leur performance et de la compétence des laboratoires à les effectuer. MÉTHODOLOGIE: Les chercheurs ont obtenu une batterie de 60 prélèvements de plasma et de sérum chez des donneurs dont l'amplification en chaîne par polymérase après transcription inverse (RT-PCR) avait confirmé des infections par le SRAS-CoV-2 et de 21 prélèvements dont les résultats étaient négatifs au SRAS-CoV-2 et les ont distribués aux laboratoires intéressés du Canada (n = 30) et des États-Unis (n = 1). Ils ont invité les laboratoires participants à fournir de l'information détaillée sur les dosages diagnostiques utilisés, les plateformes sur lesquelles les dosages étaient exécutés et les résultats obtenus pour chaque échantillon. Les chercheurs ont demandé aux laboratoires participants de fournir de l'information détaillée sur les dosages diagnostiques utilisés, les plateformes sur lesquelles les dosages ont été effectués, et les résultats obtenus à l'égard de chaque échantillon. Les laboratoires ont mené les études à l'insu des résultats escomptés. RÉSULTATS: Les divers dosages avaient une excellente exécution, les plateformes à haut débit de Roche, d'Ortho et de Siemens démontrant une sensibilité de 100 %. La plupart des autres plateformes à haut débit avaient des sensibilités de plus de 93 %, à l'exception des dosages des IgG faisant appel à l'analyseur ARCHITECT d'Abbott, dont la sensibilité moyenne était de seulement 87 %. La majorité des plateformes à haut débit avaient également une très bonne spécificité (plus de 97 %). CONCLUSION: La présente étude de compétence démontre que la plupart des dosages sérologiques du SRAS-CoV-2 évalués dans des laboratoires sanitaires provinciaux ou les laboratoires hospitaliers du Canada possèdent une sensibilité acceptable et une excellente spécificité.

2.
J Clin Virol ; 142: 104933, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34364133

RESUMEN

BACKGROUND: COVID-19 seroprevalence studies use serum/plasma samples to detect SARS-CoV-2 IgG. Data supporting alternate specimen types and freeze-thaw antibody stability is lacking. The stability of IgG and other immunoglobulins in multiple blood sample types stored in differing conditions and multiple freeze-thaw cycles (FTCs) was evaluated. MATERIALS AND METHODS: Serum, plasma, and heparinized-plasma samples were collected from COVID-19 recovered individuals. Samples underwent testing for SARS-CoV-2 antibodies upon collection, after each of 10-12 FTCs, and storage at -70°C, -20°C, 4°C, and room-temperature for 10-12 days using four high-throughput commercial assays, two rapid-test cassettes, a manual ELISA, and a surrogate neutralization assay. RESULTS: All three specimen types were collected from 34 COVID-19 recovered seropositive individuals (≥21 days post-symptoms). Using the Architect and Liaison assays, a positive qualitative SARS-CoV-2 IgG result was detected daily up to 12 FTCs and up to 10 days of storage at different temperatures. An additional 25 plasma samples consistently demonstrated detection of SARS-CoV-2 antibodies daily after 12 FTCs and storage at -20°C using two rapid test cassette assays (SD Biosensor and Hangzhou All Test), manual (Beijing Wantai) and surrogate neutralization (GenScript) ELISAs, and two high-throughput assays (Roche Elecsys nucleocapsid and spike). IgM antibodies were less frequently detected by one of the rapid test cassette assays. CONCLUSIONS: Serum, plasma, and heparinized-plasma constitute reliable samples for SARS-CoV-2 antibody detection. In particular, the IgG response was stable and reliably detected after multiple FTCs and storage at common laboratory conditions. IgM detection was variable due to the labile nature of this antibody class.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Inmunoglobulina G , Laboratorios , Sensibilidad y Especificidad , Estudios Seroepidemiológicos
4.
Can J Infect Dis ; 12(3): 169-73, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-18159335

RESUMEN

The first confirmed case of hantavirus pulmonary syndrome in Manitoba was diagnosed in 1999. To define better the risk of exposure to hantaviruses in this area, the clinical features and epidemiological factors pertaining to this case were described, and a serological survey of rodents collected near the patient's residence was undertaken. Small mammals were collected using live traps, were anesthetized via inhalation of isoflurane and were bled. Human and mouse serologies were undertaken using an ELISA to detect hantavirus-specific immunoglobulin G and/or immunoglobulin M antibodies. In addition, a full medical and epidemiological assessment, as well as individual risk factor and exposure analysis, were conducted. A 27-year-old Manitoba woman presented with severe respiratory distress and diffuse bilateral air space disease radiologically. Despite extremely aggressive measures, including mechanical ventilation, antibiotics, fluid management and inotropic support, the patient's condition rapidly deteriorated, and she died 8 h after admission. Hantavirus pulmonary syndrome was confirmed by the detection of immunoglobulin M and immunoglobulin G antibodies to the Sin Nombre virus (SNV) in her sera and by the demonstration of SNV genomic sequences in her lung tissue. Exposure to hantavirus likely occurred in and around the home or in the rural area in which she resided. A total of 252 small mammals, primarily deer mice (Peromyscus maniculatus), were collected from 17 different sites at or near where the patient lived. Antibodies to SNV were detected in 28 of 244 (11.5%) deer mice, which were collected within 9 km of the residence of the fatal case, indicating that these rodents are a significant reservoir for SNV in this area.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...