Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Oncol Pharm Pract ; 22(1): 60-7, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25293722

RESUMEN

OBJECTIVES: Contamination of workplace surfaces by antineoplastic drugs presents an exposure risk for healthcare workers. Traditional instrumental methods to detect contamination such as liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) are sensitive and accurate but expensive. Since immunochemical methods may be cheaper and faster than instrumental methods, we wanted to explore their use for routine drug residue detection for preventing worker exposure. METHODS: In this study we examined the feasibility of using fluorescence covalent microbead immunosorbent assay (FCMIA) for simultaneous detection and semi-quantitative measurement of three antineoplastic drugs (5-fluorouracil, paclitaxel, and doxorubicin). The concentration ranges for the assay were 0-1000 ng/ml for 5-fluorouracil, 0-100 ng/ml for paclitaxel, and 0-2 ng/ml for doxorubicin. The surface sampling technique involved wiping a loaded surface with a swab wetted with wash buffer, extracting the swab in storage/blocking buffer, and measuring drugs in the extract using FCMIA. RESULTS: There was no significant cross-reactivity between these drugs at the ranges studied indicated by a lack of response in the assay to cross analytes. The limit of detection (LOD) for 5-fluorouracil on the surface studied was 0.93 ng/cm(2) with a limit of quantitation (LOQ) of 2.8 ng/cm(2), the LOD for paclitaxel was 0.57 ng/cm(2) with an LOQ of 2.06 ng/cm(2), and the LOD for doxorubicin was 0.0036 ng/cm(2) with an LOQ of 0.013 ng/cm(2). CONCLUSION: The use of FCMIA with a simple sampling technique has potential for low cost simultaneous detection and semi-quantitative measurement of surface contamination from multiple antineoplastic drugs.


Asunto(s)
Antineoplásicos/química , Contaminación de Medicamentos/prevención & control , Exposición Profesional/análisis , Cromatografía Liquida/métodos , Doxorrubicina/química , Fluorouracilo/química , Humanos , Técnicas de Inmunoadsorción , Límite de Detección , Microesferas , Paclitaxel/química , Espectrometría de Masas en Tándem/métodos , Lugar de Trabajo
2.
J Oncol Pharm Pract ; 22(3): 396-408, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25956418

RESUMEN

OBJECTIVES: Contamination of workplace surfaces by antineoplastic drugs presents an exposure risk for healthcare workers. Traditional instrumental methods to detect contamination such as gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-tandem mass spectrometry (LC-MS/MS) are sensitive and accurate but expensive and incapable of producing results in real time. This limits their utility in preventing worker exposure. We are currently developing monitors based on lateral flow immunoassay that can detect drug contamination in near real time. In this report, we describe the laboratory performance of a 5-fluorouracil (5-FU) monitor. METHODS: The monitor was evaluated by spiking ceramic, vinyl, composite, stainless steel, and glass surfaces of 100 cm(2) area with 5-FU masses of 0, 5, 10, 25, 50, and 100 ng. The surface was sampled with a wetted cotton swab, the swab was extracted with buffer, and the resulting solution was applied to a lateral flow monitor. Two ways of evaluating the response of these monitors were used: an electronic method where a lateral flow reader was used for measuring line intensities, and a visual method where the intensity of the test line was visually compared to the control line. RESULTS: The 5-FU monitor is capable of detecting 10 ng/100 cm(2) (0.1 ng/cm(2)) using the electronic reader and 25 ng/100 cm(2) (0.25 ng/cm(2)) using the visual comparison method for the surfaces studied. The response of the monitors was compared to LC-MS/MS results for the same samples for validation and there was good correlation of the two methods but some differences in absolute response, especially at higher spiking levels for the surface samples.


Asunto(s)
Antineoplásicos/análisis , Química Farmacéutica/métodos , Sistemas de Computación , Contaminación de Medicamentos , Fluorouracilo/análisis , Lugar de Trabajo/normas , Antineoplásicos/química , Cromatografía Liquida/métodos , Fluorouracilo/química , Humanos , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem/métodos
3.
J Occup Environ Hyg ; 12(1): 45-50, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25379615

RESUMEN

Surface contamination from methamphetamine in meth labs continues to be a problem. We had previously developed a lateral flow assay cassette for field detection of methamphetamine contamination that is commercially available and has been used by a number of groups to assess contamination. This cassette uses the complete disappearance of the test line as an end point for detection of 50 ng/100 cm2 of methamphetamine contamination for surface sampling with cotton swabs. In the present study, we further evaluate the response of the cassettes using an electronic lateral flow reader to measure the intensities of the test and control lines. The cassettes were capable of detecting 0.25 ng/ml for calibration solutions. For 100 cm2 ceramic tiles that were spiked with methamphetamine and wiped with cotton-tipped wooden swabs wetted in assay/sampling buffer, 1 ng/tile was detected using the reader. Semi-quantitative results can be produced over the range 0-10 ng/ml for calibration solutions and 0-25 ng/tile for spiked tiles using either a 4-parameter logistic fit of test line intensity versus concentration or spiked mass or the ratio of the control line to the test line intensity fit to concentration or spiked mass. Recovery from the tiles was determined to be about 30% using the fitted curves. Comparison of the control line to the test line was also examined as a possible visual detection end point and it was found that the control line became more intense than the test line at 0.5 to 1 ng/ml for calibration solutions or 1 to 2 ng/tile for spiked tiles. Thus the lateral flow cassettes for methamphetamine have the potential to produce more sensitive semi-quantitative results if an electronic lateral flow reader is used and can be more sensitive for detection if the comparison of the control line to the test line is used as the visual end point.


Asunto(s)
Inmunoensayo/instrumentación , Inmunoensayo/métodos , Metanfetamina/análisis , Calibración , Exposición a Riesgos Ambientales , Sensibilidad y Especificidad , Propiedades de Superficie
4.
Am J Ind Med ; 52(11): 868-75, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19753596

RESUMEN

BACKGROUND: Recent surveys suggest nail technicians, particularly artificial nail applicators, have increased respiratory symptoms and asthma risk. METHODS: We examined lung function (n = 62) and a marker of airway inflammation, i.e., exhaled nitric oxide (ENO) (n = 43), in a subset of nail technician and control participants in a pilot health assessment. RESULTS: Bivariate analysis of technicians demonstrated that job latency was inversely correlated with FEV1 percent predicted (FEV1PP) (r = -0.34, P = 0.03) and FVCPP (r = -0.32, P = 0.05). Acrylic gel contact hours were inversely correlated with FEV1PP (r = -0.38, P = 0.02) and FVCPP (r = -0.47, P = 0.003). Current smoking was inversely and significantly (P

Asunto(s)
Industria de la Belleza , Salud Laboral , Adulto , Pruebas Respiratorias , Femenino , Humanos , Masculino , Análisis Multivariante , Uñas , Óxido Nítrico/análisis , Proyectos Piloto , Espirometría , Adulto Joven
5.
Pharmacoepidemiol Drug Saf ; 17(11): 1060-7, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18781705

RESUMEN

BACKGROUND: In 2002, CDC initiated the Anthrax Vaccination Program (AVP) to provide voluntary pre-exposure anthrax vaccination for individuals at high risk for exposure to Bacillus anthracis spores. The AVP offered an opportunity to investigate hypothesized reasons for a reported gender difference in injection site adverse events (AEs) following anthrax vaccine adsorbed (AVA). OBJECTIVES: To evaluate in women the impact of body mass index (BMI), pre-vaccination serum progesterone levels, and pre-vaccination anti-anthrax protective antigen immunoglobulin G concentrations (anti-PA IgG) on the occurrence of AEs following subcutaneous AVA vaccination. METHODS: Participants' BMI was determined at enrollment. Also, pre-vaccination blood samples were assayed for serum progesterone and anti-PA IgG. Post-vaccination solicited AEs were recorded by participants using a 4-day diary card. RESULTS: Obese group had an elevated risk for arm soreness. Decreased pre-vaccination serum progesterone level was associated with arm swelling. Increased pre-vaccination anti-PA IgG was associated with itching on the arm; and within the obese group, was associated with arm swelling, lump or knot, redness, soreness, and warmth. CONCLUSIONS: In AVA vaccinated women, obesity was associated with arm soreness and decreased pre-vaccination serum progesterone levels were associated with increased rate of arm swelling. Increased pre-vaccination anti-PA IgG may be associated with an increased frequency of itching on the arm, and in obese women, may increase the occurrence of arm swelling, lump or knot, redness, and warmth. Administering AVA according to a woman's menstrual phase may reduce the occurrence of certain injection site reactions.


Asunto(s)
Vacunas contra el Carbunco/efectos adversos , Carbunco/inmunología , Anticuerpos Antibacterianos/sangre , Índice de Masa Corporal , Edema/etiología , Inmunoglobulina G/sangre , Obesidad/complicaciones , Progesterona/sangre , Prurito/etiología , Adolescente , Adulto , Vacunas contra el Carbunco/administración & dosificación , Brazo , Edema/inmunología , Edema/metabolismo , Femenino , Humanos , Inyecciones , Masculino , Persona de Mediana Edad , Obesidad/sangre , Obesidad/inmunología , Oportunidad Relativa , Prurito/inmunología , Prurito/metabolismo , Medición de Riesgo , Factores de Riesgo , Factores Sexuales , Adulto Joven
6.
Clin Vaccine Immunol ; 15(4): 644-9, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18321882

RESUMEN

Currently, there is no routine monitoring of an immune response to the anthrax vaccine. Simple on-site tests are needed to evaluate the antibody response of anthrax-vaccinated individuals in the Armed Forces and others at high risk. Using a prototype lateral flow assay (LFA) (R. E. Biagini, D. L. Sammons, J. P. Smith, B. A. MacKenzie, C. A. F. Striley, J. E. Snawder, S. A. Robertson, and C. P. Quinn, Clin. Vaccine Immunol. 13:541-546, 2006), we investigated the agreement between a validated anthrax protective antigen (PA) immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) and the LFA for 335 unvaccinated and vaccinated subjects. We also investigated the performance of the LFA under the following conditions: thermal shock (i.e., thermal cycling between temperature extremes), high temperature/high relative humidity, high temperature/low relative humidity, and low temperature/low relative humidity. With the anti-PA ELISA used as a standard, the LFA was shown to be optimally diagnostic at 11 microg/ml anti-PA-specific IgG. At this concentration, the LFA specificity and sensitivity were 98% (95% confidence interval [CI], 97% to 100%) and 92% (CI, 88% to 97%), respectively. Receiver operating characteristic curve analysis yielded an area under the curve value of 0.988 (CI, 0.976 to 1.00), suggesting that the LFA is an extremely accurate diagnostic test. For < or = 4 or > or = 50 microg/ml PA-specific IgG, the LFA results for each environmental condition were identical to those obtained in the laboratory. These data indicate that this rapid point-of-care test would be a feasible tool in monitoring the serological antibody responses of individuals that have been vaccinated against anthrax.


Asunto(s)
Vacunas contra el Carbunco/inmunología , Inmunoglobulina G/sangre , Sistemas de Atención de Punto , Carbunco/prevención & control , Vacunas contra el Carbunco/sangre , Vacunas contra el Carbunco/farmacología , Especificidad de Anticuerpos , Antígenos Bacterianos/inmunología , Ensayo de Inmunoadsorción Enzimática , Epítopos , Humanos , Inmunoensayo/métodos , Inmunoglobulina G/inmunología , Sensibilidad y Especificidad
7.
Anal Bioanal Chem ; 388(3): 613-8, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17404717

RESUMEN

The purpose of this study was to evaluate the precision and accuracy of a commercial multiplexed kit for the measurement of 9 anti-nuclear antibodies (ANAs; anti-SS/A, anti-SS/B, anti-Sm, anti-RNP, anti-Jo-1, anti-Scl-70, anti-dsDNA, anti-Centromere B, and anti-Histone), and to compare these results to a subset of ANAs measured by enzyme-linked immunosorbent assays (ELISA) and immunodiffusion (ID). Sera were obtained from 22 systemic lupus erythematosus (SLE) patients, twelve controls and five others (commercial source) with various autoimmune diseases. ANA results from the AtheNA MultiLyte ANA II Assay (AtheNA) were compared to ELISA results (controls) and patients (ID). The AtheNA interassay coefficients of variation (CVs, N = 39, performed in duplicate; replicated 3x) ranged from 6.2% to 16.7% (mean = 9.8%), while the intra-assay CVs ranged from 5.8% to 14.3% (mean = 10.8%). Compared to results for SLE cases and controls, the sensitivity of AtheNA ranged from 85.7% to 100% (mean = 97.1%), while diagnostic specificity ranged from 16.7% to 100% (mean = 71.6%). There was significant agreement (P values ranging from 0.0001 to 0.03) when analytes coanalyzed by AtheNA and ELISA/ID were evaluated using Cohen's kappa (kappa values ranging from 0.376 to 1.000). No false positive ANA results were observed for either the control or commercial source autoimmune disease sera. These results indicate that the AtheNA assay is a precise and accurate alternative for performing multiple ELISAs or IDs in the diagnosis of autoimmune diseases, especially when the number of sera to be tested is large, such as in clinical screening or epidemiologic studies. It also appears that the AtheNA assay identifies positive ANA specificities which are missed by ID techniques, suggesting that it may have greater analytical sensitivity for some ANAs.


Asunto(s)
Anticuerpos Antinucleares/sangre , Inmunoensayo/métodos , Lupus Eritematoso Sistémico/sangre , Estudios de Casos y Controles , Ensayo de Inmunoadsorción Enzimática , Humanos , Lupus Eritematoso Sistémico/inmunología , Sensibilidad y Especificidad
8.
Ann Allergy Asthma Immunol ; 97(2): 196-202, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16937751

RESUMEN

BACKGROUND: In the absence of a US Food and Drug Administration (FDA)-cleared latex skin testing reagent, in vitro tests remain important for the diagnosis of latex allergy. OBJECTIVE: To evaluate the performance characteristics of IMMULITE 2000 3gAllergy (Immulite), a third-generation, FDA-cleared, continuous random-access immunoanalyzer, for the quantification of latex specific IgE. METHODS: Stored serum samples (N = 201) from patients classified as having positive or negative latex puncture skin test results were measured for latex specific IgE levels using Immulite, and these data were compared with historical results from 3 second-generation, FDA-cleared IgE antilatex assays (AlaSTAT [Ala], AutoCAP [CAP], and HY*TEC enzyme immunoassay [HT]). RESULTS: The diagnostic performances of the CAP, Ala, and Immulite assays (> or = 0.35 kU/L cutoff value) were equivalent in sensitivity and specificity (P > .05). The HT assay (> or = 0.05 kU/L cutoff value) was more sensitive and less specific (P < .05). Immulite (> or = 0.10 kU/L cutoff value) had greater sensitivity than Ala and CAP and greater specificity than HT (P < .05 for both). Diagnostic efficiency was greater for Immulite than for CAP, Ala, and HT (P < .05). CONCLUSIONS: The Immulite system is superior in diagnostic performance, especially at the 0.10 kU/L or greater cutoff level, for the diagnosis of latex allergy compared with older, second-generation assays. Immulite still misclassifies 15.5% of puncture skin test-positive individuals as negative for latex specific IgE. Compared with second-generation assays, Immulite represents a technological advance, with enhanced speed and less operator intervention.


Asunto(s)
Técnicas para Inmunoenzimas , Inmunoglobulina E/sangre , Hipersensibilidad al Látex/diagnóstico , Pruebas Cutáneas , Humanos , Hipersensibilidad al Látex/sangre , Hipersensibilidad al Látex/inmunología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo
9.
Clin Vaccine Immunol ; 13(5): 541-6, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16682473

RESUMEN

Evidence from animals suggests that anti-anthrax protective antigen (PA) immunoglobulin G (IgG) from vaccination with anthrax vaccine adsorbed (AVA) is protective against Bacillus anthracis infection. Measurement of anti-PA IgG in human sera can be performed using either enzyme-linked immunosorbent assay or fluorescent covalent microsphere immunoassay (ELISA) (R. E. Biagini, D. L. Sammons, J. P. Smith, B. A. MacKenzie, C. A. Striley, V. Semenova, E. Steward-Clark, K. Stamey, A. E. Freeman, C. P. Quinn, and J. E. Snawder, Clin. Diagn. Lab. Immunol. 11:50-55, 2004). Both these methods are laboratory based. We describe the development of a rapid lateral-flow immunochromatographic assay (LFIA) test kit for the measurement of anti-PA IgG in serum or whole-blood samples (30-microl samples) using colloidal gold nanoparticles as the detection reagent and an internal control. Using sera from 19 anthrax AVA vaccinees (anti-PA IgG range, 2.4 to 340 microg/ml) and 10 controls and PA-supplemented whole-blood samples, we demonstrated that the LFIA had a sensitivity of approximately 3 microg/ml anti-PA IgG in serum and approximately 14 microg/ml anti-PA IgG in whole blood. Preabsorption of sera with PA yielded negative anti-PA LFIAs. The diagnostic sensitivity and specificity of the assay were 100% using ELISA-measured anti-PA IgG as the standard. This kit has utility in determining anti-PA antibody reactivity in the sera of individuals vaccinated with AVA or individuals with clinical anthrax.


Asunto(s)
Carbunco/inmunología , Anticuerpos Antibacterianos/sangre , Antígenos Bacterianos/inmunología , Bacillus anthracis/inmunología , Toxinas Bacterianas/inmunología , Cromatografía/métodos , Inmunoensayo/métodos , Carbunco/sangre , Carbunco/diagnóstico , Cromatografía/instrumentación , Coloides/química , Oro/química , Humanos , Inmunoensayo/instrumentación , Inmunoglobulina G/sangre , Nanoestructuras/química , Sensibilidad y Especificidad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA