Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int Arch Occup Environ Health ; 93(6): 723-731, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32078051

RESUMEN

OBJECTIVE: To determine if heavy manual work affects sensory perception in the digits and whether Semmes-Weinstein monofilaments (SWM) can be used as a screening tool to detect sensory neuropathy in the digits of workers exposed to hand-transmitted vibration (HTV). METHODS: A cross-sectional study of office workers, heavy manual workers not exposed to HTV and workers with hand-arm vibration syndrome (HAVS). Sensory perception was measured in the digits by SWM using a forced-choice method to determine variability by sex, age, hand and digit. Frequency distributions were used to determine limit values and linear weighted kappa for intra-digit variability. Poisson regression was used to explore the relationship between sensory perception by SWM and abnormalities of thermal and vibration perception in the hands of workers with HAVS. RESULTS: The sensory perception threshold of office workers did not vary by hand or digit. It was significantly lower in women < 30 than women aged ≥ 30 years. The 95th percentile for heavy manual workers was 1.00 (95% CI 0.60-1.00) and significantly higher than for office workers at 0.16 (95% CI 0.16-0.16). Heavy manual workers > 50 years had the highest threshold at 1.40 (95% CI 1.00-2.00). Weighted kappa for reliability was 0.63 (95% CI 0.53-0.70). A mean SWM threshold of ≥ 1.0 gram-force had a 79% sensitivity and 64% specificity for detecting abnormalities of thermal and vibration perception in the ipsilateral index and little fingers of workers with HAVS. CONCLUSIONS: SWM are a useful screening tool for detecting sensory loss in the digits of workers exposed to HTV.


Asunto(s)
Síndrome por Vibración de la Mano y el Brazo/diagnóstico , Enfermedades Profesionales/diagnóstico , Trastornos de la Sensación/diagnóstico , Umbral Sensorial , Adulto , Anciano , Femenino , Dedos , Humanos , Masculino , Persona de Mediana Edad , Vibración , Adulto Joven
2.
Rev Sci Instrum ; 86(9): 094102, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26429459

RESUMEN

An Adaptable Multiple Power Source (AMPS) system has been designed and constructed. The AMPS system can provide up to 16 direct current (DC) (±400 V; 5 mA), 4 radio frequency (RF) (two 500 VPP sinusoidal signals each, 0.5-5 MHz) channels, 2 high voltage sources (±6 kV), and one ∼40 W, 250 °C temperature-regulated heater. The system is controlled by a microcontroller, capable of communicating with its front panel or a computer. It can assign not only pre-saved fixed DC and RF signals but also profiled DC voltages. The AMPS system is capable of driving many mass spectrometry components and ancillary devices and can be adapted to other instrumentation/engineering projects.


Asunto(s)
Suministros de Energía Eléctrica , Espectrometría de Masas/instrumentación , Diseño de Equipo , Análisis de Fourier , Ondas de Radio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...