Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 9(1): 8551, 2019 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-31189924

RESUMEN

We demonstrate here for the first time that charge emitted by laser-target interactions at petawatt peak-powers can be efficiently deposited on a capacitor-collector structure far away from the target and lead to the rapid (tens of nanoseconds) generation of large quasi-static electric fields over wide (tens-of-centimeters scale-length) regions, with intensities much higher than common ElectroMagnetic Pulses (EMPs) generated by the same experiment in the same position. A good agreement was obtained between measurements from a classical field-probe and calculations based on particle-flux measurements from a Thomson spectrometer. Proof-of-principle particle-in-cell simulations reproduced the measurements of field evolution in time, giving a useful insight into the charging process, generation and distribution of fields. The understanding of this charging phenomenon and of the related intense fields, which can reach the MV/m order and in specific configurations might also exceed it, is very important for present and future facilities studying laser-plasma-acceleration and inertial-confinement-fusion, but also for application to the conditioning of accelerated charged-particles, the generation of intense electric and magnetic fields and many other multidisciplinary high-power laser-driven processes.

2.
Appl Opt ; 56(24): 6982-6987, 2017 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-29048046

RESUMEN

We report a new method using high-stability, laser-driven supercontinuum generation in a liquid cell to calibrate the absolute photon response of fast optical streak cameras as a function of wavelength when operating at fastest sweep speeds. A stable, pulsed white light source based around the use of self-phase modulation in a salt solution was developed to provide the required brightness on picosecond time scales, enabling streak camera calibration in fully dynamic operation. The measured spectral brightness allowed for absolute photon response calibration over a broad spectral range (425-650 nm). Calibrations performed with two Axis Photonique streak cameras using the Photonis P820PSU streak tube demonstrated responses that qualitatively follow the photocathode response. Peak sensitivities were one photon/count above background. The absolute dynamic sensitivity is less than the static by up to an order of magnitude. We attribute this to the dynamic response of the phosphor being lower.

3.
Sci Rep ; 7(1): 983, 2017 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-28428549

RESUMEN

We report on the development and deployment of an optical diagnostic for single-shot measurement of the electric-field components of electromagnetic pulses from high-intensity laser-matter interactions in a high-noise environment. The electro-optic Pockels effect in KDP crystals was used to measure transient electric fields using a geometry easily modifiable for magnetic field detection via Faraday rotation. Using dielectric sensors and an optical fibre-based readout ensures minimal field perturbations compared to conductive probes and greatly limits unwanted electrical pickup between probe and recording system. The device was tested at the Vulcan Petawatt facility with 1020 W cm-2 peak intensities, the first time such a diagnostic has been used in this regime. The probe crystals were located ~1.25 m from target and did not require direct view of the source plasma. The measured signals compare favourably with previously reported studies from Vulcan, in terms of the maximum measured intra-crystal field of 10.9 kV/m, signal duration and detected frequency content which was found to match the interaction chamber's horizontal-plane fundamental harmonics of 76 and 101 MHz. Methods for improving the diagnostic for future use are also discussed in detail. Orthogonal optical probes offer a low-noise alternative for direct simultaneous measurement of each vector field component.

4.
Phys Rev Lett ; 116(22): 225001, 2016 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-27314720

RESUMEN

We present experiments characterizing the detailed structure of a current layer, generated by the collision of two counterstreaming, supersonic and magnetized aluminum plasma flows. The antiparallel magnetic fields advected by the flows are found to be mutually annihilated inside the layer, giving rise to a bifurcated current structure-two narrow current sheets running along the outside surfaces of the layer. Measurements with Thomson scattering show a fast outflow of plasma along the layer and a high ion temperature (T_{i}∼Z[over ¯]T_{e}, with average ionization Z[over ¯]=7). Analysis of the spatially resolved plasma parameters indicates that the advection and subsequent annihilation of the inflowing magnetic flux determines the structure of the layer, while the ion heating could be due to the development of kinetic, current-driven instabilities.

5.
Appl Opt ; 54(36): 10592-8, 2015 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-26837022

RESUMEN

We report on the design and testing of a multiwavelength interferometry system for the Orion laser facility based upon the use of self-path matching Wollaston prisms. The use of UV corrected achromatic optics allows for both easy alignment with an eye-safe light source and small (∼ millimeter) offsets to the focal lengths between different operational wavelengths. Interferograms are demonstrated at wavelengths corresponding to first, second, and fourth harmonics of a 1054 nm Nd:glass probe beam. Example data confirms the broadband achromatic capability of the imaging system with operation from the UV (263 nm) to visible (527 nm) and demonstrates that features as small as 5 µm can be resolved for object sizes of 15 by 10 mm. Results are also shown for an off-harmonic wavelength that will underpin a future capability. The primary optics package is accommodated inside the footprint of a ten-inch manipulator to allow the system to be deployed from a multitude of viewing angles inside the 4 m diameter Orion target chamber.

6.
J Infect Dis ; 184(9): 1183-6, 2001 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-11598842

RESUMEN

Neutralization of human papillomavirus type 11 (HPV-11) has been demonstrated using serum and cervical secretions from primates vaccinated with virus-like particles (VLPs). Theoretically, neutralizing antibodies could protect women from HPV infection. The immunogenicity of a yeast-derived HPV-11 L1 VLP vaccine was tested in women. Serum specimens were evaluated for HPV-11 titer by competitive radioimmunoassay (cRIA) and for neutralization by use of the athymic mouse xenograft system. Analysis of serum from 104 subjects showed a dose response in HPV-11 cRIA titers and neutralization. Overall, 68 (82.9%) of 82 postimmunization serum specimens from VLP recipients were 100% neutralizing when used in the assay at a 1:50 dilution. Of 69 serum specimens, 63 (91.3%) with cRIA titers >200 milliMerck units per milliliter were neutralizing. Immunization with HPV VLPs elicits a vigorous serum immune response in a high percentage of women. The HPV-11 cRIA titer appears to be a surrogate marker for neutralization.


Asunto(s)
Anticuerpos Antivirales/inmunología , Papillomaviridae/inmunología , Infecciones por Papillomavirus/prevención & control , Infecciones Tumorales por Virus/prevención & control , Vacunas Virales/inmunología , Virión/inmunología , Adolescente , Adulto , Animales , Anticuerpos Antivirales/sangre , Relación Dosis-Respuesta a Droga , Método Doble Ciego , Femenino , Humanos , Ratones , Pruebas de Neutralización , Papillomaviridae/genética , Infecciones por Papillomavirus/virología , Radioinmunoensayo , Infecciones Tumorales por Virus/virología , Vacunación , Vacunas Sintéticas/inmunología , Levaduras/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...