Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Infect Control Hosp Epidemiol ; 31(2): 165-70, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20025531

RESUMEN

OBJECTIVE: To determine the rate of bacterial and viral contamination of endocavitary ultrasound probes after endorectal or endovaginal examination with the use of probe covers and to evaluate the antimicrobial efficacy of a disinfection procedure consisting of cleaning with a disinfectant-impregnated towel followed by disinfection with ultraviolet C (UVC) light. METHODS: Endovaginal or endorectal ultrasound examinations were performed for 440 patients in 3 institutions. All probes were covered by a condom or sheath during the examination. For bacterial analysis, 1 swab was applied lengthwise across one-half the surface of the probe just after removal of the probe cover. The second swab was similarly applied over the probe immediately after the end of a 2-step process consisting of cleaning with a towel impregnated with a disinfectant spray and a 5-minute UVC disinfection cycle. Swabs were applied onto plates and incubated for 48 hours. The number of colony-forming units was counted, and organisms were identified. A similar protocol was used for viral detection of Epstein-Barr virus, human cytomegalovirus, and human papillomavirus, except that an additional swab was applied along the entire external surface of the probe cover before its removal. Viruses were detected by means of a polymerase chain reaction-based protocol. RESULTS: After removal of probe covers, contamination by pathogenic bacteria was found for 15 (3.4% [95% confidence interval, 2.0%-5.6%]) of 440 probes, and viral genome was detected on 5 (1.5% [95% confidence interval, 0.5%-3.5%]) of 336 probes. After cleaning with a towel impregnated with a disinfectant spray and disinfecting with UVC light, neither bacterial pathogenic flora nor viral genome was recovered from the probe. CONCLUSIONS: Endocavitary ultrasound probes may carry pathogens after removal of covers under routine conditions. A disinfection procedure consisting of cleaning with a disinfectant-impregnated towel followed by disinfection with UVC may provide a useful method for disinfecting endocavitary ultrasound probes.


Asunto(s)
Desinfectantes/administración & dosificación , Desinfección/métodos , Contaminación de Equipos/prevención & control , Transductores/microbiología , Transductores/virología , Ultrasonografía/instrumentación , Rayos Ultravioleta , Antiinfecciosos/administración & dosificación , Antiinfecciosos/farmacología , Bacterias/clasificación , Bacterias/efectos de los fármacos , Bacterias/aislamiento & purificación , Infección Hospitalaria/microbiología , Infección Hospitalaria/prevención & control , Infección Hospitalaria/virología , Desinfectantes/farmacología , Femenino , Humanos , Masculino , Ultrasonografía/métodos , Virus/clasificación , Virus/efectos de los fármacos , Virus/aislamiento & purificación
2.
Arch Intern Med ; 167(19): 2086-90, 2007 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-17954803

RESUMEN

BACKGROUND: Health care workers' compliance with isolation precautions for patients colonized or infected with multidrug-resistant bacteria (MRB) is low. METHODS: In a 750-bed, acute care university hospital with a patient information system covering the entire hospital, a database that included all patients with MRB was created and was merged daily with the admission-discharge-transfer application. An electronic alert was generated for all new cases of MRB and for all transfers between wards and all readmissions of patients with MRB. Two successive interventions were implemented based on this alert system. First, alerts were dispatched to medical and staff members in charge of infection control in each ward with requests to order isolation precautions for the patients. Second, alerts were dispatched to the infection control team, who directly ordered implementation of isolation precautions in electronic nursing records. Five audits during a 3-year period were performed to evaluate their effect on health care workers' compliance with isolation precautions. RESULTS: Awareness of the MRB status for the nurses in charge of the patients statistically significantly increased from 24.0% at baseline to 59.4% at 1 year after the first intervention. This proportion improved to 93.1% at 1 year after the second intervention. Similarly, the implementation of isolation precautions statistically significantly increased from 15.0% at baseline to 50.5% at 1 year after the first intervention and then to 90.2% at 1 year after the second intervention. CONCLUSION: A computer alert system can lead to effective and lasting improvement in the implementation of isolation precautions for patients with MRB in health care institutions.


Asunto(s)
Infecciones Bacterianas/prevención & control , Infección Hospitalaria/prevención & control , Resistencia a Múltiples Medicamentos , Sistemas de Información en Hospital , Control de Infecciones/métodos , Aislamiento de Pacientes , Infecciones Bacterianas/tratamiento farmacológico , Distribución de Chi-Cuadrado , Humanos , Distribución de Poisson
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...