Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Cardiovasc Revasc Med ; 61: 1-5, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37996263

RESUMEN

BACKGROUND: Data regarding the mean resident time (RT) after left main (LM) bifurcation stenting are scant. In the present study we performed a patient-specific computational fluid dynamic (CFD) analysis to investigate the different post-stenting mean RT values in LM patients treated with single-or double stenting techniques. METHODS: Patients were identified after reviewing the local Optical Coherence Tomography (OCT) scans database. Overall, 27 patients (mean age 65.5 ± 12.4, 21 males) [10 patients treated with provisional cross-over stenting, 7 with the double kissing crush (DK crush) and 10 with the nano-inverted T (NIT) technique, respectively] with isolated and significant LM bifurcation disease were analyzed. RESULTS: After LM bifurcation stenting, the NIT showed a higher averages WSS values at all bifurcation sites compared to DK crush and provisional cross-over stenting. Moreover, the mean RT resulted lower after NIT compared to provisional or DK crush. During the diastolic phase, the average RT of the entire LM bifurcation was 0.46 s, 0.38 s and 0.33 s after using the provisional stenting, DK crush and NIT, respectively. Moreover, the average RT in the LM bifurcation decreased by 17.1 % using the DK crush and by 28.2 % using the NIT compared to the Provisional. CONCLUSION: The present OCT-derived CFD analysis revealed that, in patients with complex bifurcation LM disease, the provisional approach resulted in lower WSS values, while double stenting techniques, especially the NIT technique, resulted in a marked reduction of average RT compared to the provisional approach. CONDENSED ABSTRACT: In the present study we performed a patient-specific Optical coherence tomography (OCT)-based computational fluid dynamic (CFD) analysis to investigate the different post-stenting mean RT values in 27 patients treated with provisional cross-over stenting, DK crush and Nano-inverted-T (NIT) stenting. The NIT showed a higher averages WSS values at all bifurcation sites compared to DK crush and Provisional. The mean RT resulted lower in NIT compared to Provisional or DK crush. During the entire diastolic phase, the average RT of the entire LM bifurcation was 0.46 s, 0.38 s and 0.33 s after using the provisional stenting, DK crush and NIT, respectively. Moreover, the average RT in the entire LM bifurcation decreased by 17.1 % using the DK crush and by 28.2 % using the NIT compared to the Provisional.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Masculino , Humanos , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Resultado del Tratamiento , Factores de Tiempo , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Stents , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Angiografía Coronaria/métodos
3.
Catheter Cardiovasc Interv ; 102(2): 221-232, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37232278

RESUMEN

BACKGROUND: Data about the long-term performance of new-generation ultrathin-strut drug-eluting stents (DES) in challenging coronary lesions, such as left main (LM), bifurcation, and chronic total occlusion (CTO) lesions are scant. METHODS: The international multicenter retrospective observational ULTRA study included consecutive patients treated from September 2016 to August 2021 with ultrathin-strut (<70 µm) DES in challenging de novo lesions. Primary endpoint was target lesion failure (TLF): composite of cardiac death, target-lesion revascularization (TLR), target-vessel myocardial infarction (TVMI), or definite stent thrombosis (ST). Secondary endpoints included all-cause death, acute myocardial infarction (AMI), target vessel revascularization, and TLF components. TLF predictors were assessed with Cox multivariable analysis. RESULTS: Of 1801 patients (age: 66.6 ± 11.2 years; male: 1410 [78.3%]), 170 (9.4%) experienced TLF during follow-up of 3.1 ± 1.4 years. In patients with LM, CTO, and bifurcation lesions, TLF rates were 13.5%, 9.9%, and 8.9%, respectively. Overall, 160 (8.9%) patients died (74 [4.1%] from cardiac causes). AMI and TVMI rates were 6.0% and 3.2%, respectively. ST occurred in 11 (1.1%) patients while 77 (4.3%) underwent TLR. Multivariable analysis identified the following predictors of TLF: age, STEMI with cardiogenic shock, impaired left ventricular ejection fraction, diabetes, and renal dysfunction. Among the procedural variables, total stent length increased TLF risk (HR: 1.01, 95% CI: 1-1.02 per mm increase), while intracoronary imaging reduced the risk substantially (HR: 0.35, 95% CI: 0.12-0.82). CONCLUSIONS: Ultrathin-strut DES showed high efficacy and satisfactory safety, even in patients with challenging coronary lesions. Yet, despite using contemporary gold-standard DES, the association persisted between established patient- and procedure-related features of risk and impaired 3-year clinical outcome.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Masculino , Persona de Mediana Edad , Anciano , Sirolimus , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Función Ventricular Izquierda , Infarto del Miocardio/etiología , Diseño de Prótesis , Stents/efectos adversos , Sistema de Registros , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones
6.
Expert Rev Med Devices ; 20(1): 29-34, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36656563

RESUMEN

INTRODUCTION: Over the last 5 years, the armamentarium of the interventional cardiologist dealing with percutaneous closure of patent foramen ovale (PFO) has been enriched by some novel devices and further improvements of existing ones that have or promise to increase the safety and effective closure rate of PFO patients. AREAS COVERED: This review presents and discusses recent advancements in device design and composition from both technical and clinical perspectives. EXPERT OPINION: Device technology is continuously evolving. The recent modification of delivery system, device hooking, and composition, as well as the advent of new bioabsorbable materials, is promising to make percutaneous PFO closure devices safer. The search for more effectiveness with possibly less metal behind is still ongoing.


Asunto(s)
Foramen Oval Permeable , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Humanos , Foramen Oval Permeable/cirugía , Cateterismo Cardíaco , Catéteres , Resultado del Tratamiento
7.
Diagnostics (Basel) ; 14(1)2023 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-38201368

RESUMEN

The prognostic value of exercise stress test after complex left main (LM) coronary artery bifurcation (LM) stenting has been poorly investigated. To partially fill this gap in knowledge, we retrospectively analyzed the procedural and medical data of consecutive patients referred to our center for complex LM bifurcation disease between January 2008 and May 2018 who were treated using either single- or dual-stenting techniques. The prognostic impact of an exercise stress test, performed 6 months after the coronary intervention, was evaluated in 502 patients (316 males, mean age 70.3 ± 12.8 years, mean Syntax score 31.6 ± 6.3). At follow up after a mean of 37.1 ± 10.8 months (range 22.1-47.3 months), the target lesion failure (TLF) rate was 10.1% while stent thrombosis and cardiovascular mortality were 1.2 and 3.6%, respectively. A positive exercise stress test was detected at 6-month follow up in 42 out of 502 patients (8.4%); the incidence of a significant restenosis was 7.6% (n = 38). Patients with a negative exercise stress test at 6-month follow up had higher freedom from TLF and improved survival compared to those with a positive exercise stress test.

8.
Artículo en Inglés | MEDLINE | ID: mdl-36511241

RESUMEN

Among the angiographic views used to evaluate left coronary system, the so-called "spider view" represents one of the most iconic, in particular for its ability to evaluate the Left Main stem (LM) and/or to guide percutaneous coronary interventions (PCIs) on LM bifurcation disease. Unfortunately, the use of such view is graved by a high X-ray exposure for both the operator and the patient. To overcome these limitations, we described an alternative coronary angiographic view, called "reverse spider" which is able to give more information about LM body and bifurcation disease with less X-ray exposure for the operator.

9.
Front Cardiovasc Med ; 9: 1056496, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36578836

RESUMEN

Objectives: To assess the impact of conventional transcatheter heart valve (THV) commissural alignment techniques on THV/coronary overlap and coronary access (CA) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV). Background: Specific Evolut Pro/Pro + and Acurate Neo2 THV orientations are associated with reduced neo-commissural overlap with coronary ostia in tricuspid aortic anatomy. Whether standard orientation techniques are effective also in the setting of BAV anatomy has not been studied. Methods: The DA VINCI (Definition of trAnscatheter aortic Valve orIeNtation in biCuspId aortic valve) pilot study is a prospective registry enrolling consecutive patients with severe BAV stenosis undergoing TAVR with last generation supra-annular tall-frame THVs implanted with a cusp overlap view-based commissural alignment. Patients underwent pre- and post-TAVR computed tomography (CT) and coronary angiography. The study endpoint was the rate of favorable THV/coronary overlap, defined as an angle > 40° between the THV commissural post and coronary ostia. Other endpoints were the rates of successful THV alignment with respect to the raphe and of selective CA after TAVR. Moreover, different virtual THV alignment models were tested to identify which one would produce the lower degree of THV/coronary overlap. Results: Thirty-four patients with type 1 BAV with right-left raphe undergoing TAVR (23 with Evolut Pro/Pro + and 11 with Acurate Neo2) were included. At pre-TAVR CT, moderate/severe cusp asymmetry was found in 50% of patients, severe coronary ostia eccentricity was observed in 47.1% for the RCA vs. 8.8% for the LCA (P < 0.007). Correct TVH orientation was achieved in 29 cases. At post-TAVR CT, optimal THV alignment/mild misalignment to the raphe was observed in 86.2%, but a moderate/severe overlap with the coronaries was seen in 13.7% for the RCA and 44.8% for the LCA (P = 0.019). After TAVR, selective RCA cannulation was possible in 82.8% vs. 75.9% for the LCA (P = 0.74), while combined selective CA of both coronaries was possible in less than two-thirds of the patients. Virtual THV alignment in the coronary ostia overlap view assuming a hypothetical circular THV expansion would produce an optimal THV/coronary overlap in almost 90% of cases. Conclusion: Given cusp asymmetry and coronary ostia eccentricity of BAV combined with potential THV asymmetrical expansion, conventional commissural alignment techniques are associated with higher rates of THV misalignment and of moderate/severe neo-commissure overlap with the coronary ostia as compared to tricuspid aortic stenosis, resulting in lower rates of selective CA after TAVR. A modified THV orientation technique based on the coronary ostia overlap view might be preferable in BAV patients.

10.
J Clin Med ; 11(22)2022 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-36431278

RESUMEN

Coronary bifurcation percutaneous interventions (PCI) comprise a challenging subset of patients with coronary artery disease. Beyond the well-known debate about single versus double stent strategies, which have different outcomes on mid- and long-term follow up, both strategies may be subject, although rarely, to several different technical complications, rarely reported in clinical trials, which need to be defined, classified, and understood by cardiovascular professionals involved in the management of patients with coronary bifurcation disease. The present paper aims to broaden the knowledge of the range of intraprocedural complications and relative treatment during PCI of coronary bifurcations.

11.
J Endovasc Ther ; : 15266028221125587, 2022 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-36214426

RESUMEN

PURPOSE: The purpose of this article is to describe an emergent in situ fenestration (ISF) technique in the ascending aorta for the endovascular repair of a large pseudoaneurysm using a trans-septal needle device through direct right common carotid artery access, in a patient with left ventricular assist device (LVAD). TECHNIQUE: We performed, in a multidisciplinary team-work approach, an emergent ISF to correct the displacement of a physician-modified thoracic endograft released in the ascending aorta to correct a large anastomotic pseudoaneurysm in a patient who underwent ascending aorta replacement and subsequent LVAD implantation. We used a trans-septal needle device inserted through a direct access to the right carotid artery and performed an ISF to restore the patency of the outflow ostium of the LVAD. Window was then completed and stabilized with a nitinol balloon expandable covered stent graft obtaining an effective exclusion of the anastomotic aortic aneurism and the regular patency of the LVAD outflow graft with no signs of leaks. CONCLUSIONS: Multidisciplinary teamwork approach can be crucial in challenging procedures where an alternative approach may lead to problem solving. The ISF technique may be a valid option to adopt in emergency cases in which no other technical solutions are suitable. CLINICAL IMPACT: The endovascular approach has become more and more frequent for the treatment of vascular pathologies, getting increasingly refined and complex. Thereby the chance of incurring intraprocedural troubles has grown and bailout strategies should always be present. In situ fenestration is a technique to be aware of and that could help you recover from difficult situations. We report a possible rescue maneuver that can be applied also in arduous anatomies such as the ascending aorta. Moreover, we would like to highlight the importance of a multidisciplinary working environment that can enrich our everyday practice accomplishing effective and unexpected solutions.

12.
Front Cardiovasc Med ; 9: 924958, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35757343

RESUMEN

Background: The impact of transcatheter aortic valve replacement (TAVR) leaflet design on long-term device performance is still unknown. This study sought to compare the clinical and hemodynamic outcomes of intra- (IA) versus supra-annular (SA) TAVR designs up-to 10-years following implantation. Methods: Consecutive patients with at least 5-years follow-up following TAVR for severe symptomatic aortic stenosis from June 2007 to December 2016 were included. Bioprosthetic valve failure (BVF) and hemodynamic valve deterioration (HVD) were defined according to VARC-3 updated definitions and estimated using cumulative incidence function to account for the competing risk of death. Results: A total of 604 patients (82 years; 53% female) were analyzed and divided into IA (482) and SA (122) groups. Overall survival rates at 10-years were similar (IA 15%, 95%CI: 10-22; SA 11%, 95%CI: 6-20; p = 0.21). Compared to the SA TAVR, mean transaortic gradients were significantly higher and increased over time in the IA group. IA TAVRs showed higher 10-year cumulative incidences of BVF (IA 8% vs. SA 1%, p = 0.02) and severe HVD (IA 5% vs. SA 1%, p = 0.05). The occurrence of BVF and HVD in the IA group occurred primarily in the smallest TAVR devices (20-23-mm). After excluding these sizes, the cumulative incidences of BVF (IA 5% vs. SA 1%, p = 0.40) and severe HVD (IA 2% vs. SA 1%, p = 0.11) were similar. Conclusion: In this study, TAVR leaflet design had no impact on survival at 10-years. IA devices showed higher transaortic gradients and cumulative incidences of HVD and BVF predominantly occurring in the smallest valve sizes.

13.
J Clin Med ; 11(11)2022 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-35683500

RESUMEN

Acute myocardial infarction (AMI) complicated by cardiogenic shock (CS) is a life-threatening condition frequently encountered in patients with multivessel coronary artery disease (CAD). Despite prompt revascularization, in particular, percutaneous coronary intervention (PCI), and therapeutic and technological advances, the mortality rate for patients with CS related to AMI remains unacceptably high. Differently form a hemodynamically stable setting, a culprit lesion-only (CLO) revascularization strategy is currently suggested for AMI-CS patients, based on the results of recent randomized evidence burdened by several limitations and conflicting results from non-randomized studies. Furthermore, mechanical circulatory support (MCS) devices have emerged as a key therapeutic option in CS, especially in the case of their early implantation without delaying revascularization and before irreversible organ damage has occurred. We provide an in-depth review of the current evidence on optimal revascularization strategies of multivessel CAD in infarct-related CS, assessing the role of different types of MCS devices and highlighting the importance of shock teams and medical care system networks to effectively impact on clinical outcomes.

15.
Front Cardiovasc Med ; 9: 832242, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35295263

RESUMEN

Backgrounds: Among vascular closure devices (VCDs), the novel collagen plug-based MANTA VCD is the first designed for large bore percutaneous access. We aimed to assess the features and predictors of access-site vascular complications in an unselected trans-femoral transcatheter aortic valve replacement (TF-TAVR) population. Methods: Patients undergoing large bore arteriotomy closure with 18F MANTA VCD following TF-TAVR at a large tertiary care center from September 2019 to January 2021 were prospectively analyzed. Primary Outcome was the MANTA VCD access-site-related complications according to Valve Academic Research Consortium-3 (VARC) definitions. Its incidence and predictors were evaluated. Results: Eighty-eight patients (median age 82 years, 48% male, 3.3 median Society of Thoracic Surgeons score) undergoing TF-TAVR were included, mostly (63%) treated with a self-expandable device and with outer diameter sizes varied from 18F to 24-F. MANTA VCD technical success rate was 98%, while 10 patients (11%) experienced MANTA VCD access-site vascular complications which included 8% of minor complications and only to 2% of major events resulting in VARC type ≥2 bleeding. Vessel occlusion/stenosis (60%), perforation (20%), and pseudoaneurysm/dissection/hematoma (20%) occurred, but all were managed without surgical treatment. Independent predictors of failure were age (p = 0.04), minimum common femoral artery diameter (CFA) (p < 0.01), sheath-to-femoral-artery ratio (SFAR) (p < 0.01), and a lower puncture height (p = 0.03). A CFA diameter <7.1 mm with a SFAR threshold of 1.01 were associated with VCD failure. Conclusions: In a more comers TF-TAVR population, MANTA VCD was associated with reassuring rates of technical success and major access-site vascular complications. Avoiding lower vessel size and less puncture site distance to CFA bifurcation might further improve outcomes.

16.
Circ Cardiovasc Interv ; 15(2): e011045, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-35167332

RESUMEN

BACKGROUND: Coronary access (CA) after transcatheter aortic valve replacement (TAVR) with supra-annular transcatheter heart valves (THV) can be challenging. Specific Evolut R/Pro and Acurate Neo THVs orientations are associated with reduced neo-commissure overlap with coronary ostia, while SAPIEN 3 THV cannot be oriented. With the ALIGN-ACCESS study (TAVR With Commissural Alignment Followed by Coronary Access), we investigated the impact of commissural alignment on the feasibility of CA after TAVR. METHODS: We performed coronary angiography after TAVR with intra-annular SAPIEN 3, supra-annular Evolut R/Pro, and Acurate Neo THVs in 206 patients. Evolut THVs were implanted aiming for commissure alignment. Alignment of Acurate Neo was retrospectively assessed in 36, intentionally attempted in 26 cases. The primary end point was the rate of unfeasible and nonselective CA after TAVR. RESULTS: Thirty-eight percent of patients received SAPIEN 3, 31.1% Evolut Pro/R, 30.1% Acurate Neo THV. Final valve orientation was favorable to commissural alignment in 85.9% of Evolut and 69.4% of Acurate Neo cases (with intentional alignment successful in 88.5%). Selective CA was higher for SAPIEN 3 than for aligned and misaligned supra-annular THVs (95% versus 71% versus 46%, P<0.001). Cannulation of at least one coronary was unfeasible with 11% misaligned supra-annular, 3% aligned supra-annular, and 0% SAPIEN 3 THVs. Independent predictors of unfeasible/nonselective CA were implantation of a misaligned supra-annular THV (odds ratio, 4.59 [95% CI, 1.81-11.61]; P<0.01), sinus of Valsalva height (odds ratio, 0.83 [95% CI, 0.7-0.98]; P=0.03), and THV-sinus of Valsalva relation (odds ratio, 1.06 [95% CI, 1.02-1.1]; P<0.01). CONCLUSIONS: Commissural alignment improves the rate of selective CA after TAVR with supra-annular THVs. Nevertheless, aligned supra-annular THVs carry higher risk of unfeasible/nonselective CA than SAPIEN 3. Patients with a misaligned supra-annular THV, low sinus of Valsalva, and higher THV-sinus of Valsalva relation are at highest risk of impaired CA after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
18.
Catheter Cardiovasc Interv ; 98(4): E581-E585, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34128584

RESUMEN

Spontaneous coronary artery dissection (SCAD) can lead to acute coronary syndrome and sudden cardiac death, particularly in young women. Observational data show that, in SCAD patients, both percutaneous coronary intervention and coronary artery bypass grafting seem to be hampered by higher technical complexity, lower success rates, and worse outcomes. As spontaneous healing is a common occurrence, expert consensus advices medical management of the acute phase, when feasible. We present the case of a young woman with SCAD of left anterior descending artery causing myocardial infarction with ST-segment elevation. High-anatomical complexity and unstable conditions of the patient made both medical management and immediate revascularization unfeasible options. Therefore, we decided to implant a percutaneous off-loading mechanical support device to improve coronary perfusion pressure by unloading the left ventricle and preserve cardiac function, preventing worse complications of acute myocardial infarction. This strategy was successful in stabilizing the patient, until the definitive revascularization treatment became an option.


Asunto(s)
Vasos Coronarios , Ventrículos Cardíacos , Disección , Femenino , Humanos , Perfusión , Resultado del Tratamiento
19.
Curr Cardiol Rep ; 23(3): 15, 2021 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-33495895

RESUMEN

PURPOSE OF REVIEW: In this review, we discuss about the reasons behind the failure of the Absorb bioresorbable vascular scaffold (BVS) device and about the challenges the future holds for the next generation of the bioresorbable scaffold (BRS) technology. RECENT FINDINGS: Absorb BVS was burdened by intrinsic structural limitations which resulted in augmented rates of device thrombosis and clinical adverse events compared to current-generation metallic stent. Nevertheless, new generation devices with novel design and materials are in development. Second generation BRS have enhanced mechanical strength, smaller footprints, less thrombogenicity and modified bioresorption. These features, paired with proper patient and lesion selection and optimal "user-friendly" implant techniques, could possibly overcome the previous BRS generation limitations, rekindling physicians, and industry interest on this promising technology.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento
20.
Circ Arrhythm Electrophysiol ; 14(1): e009028, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33306415

RESUMEN

BACKGROUND: Conduction disturbances after transcatheter aortic valve replacement (TAVR) are often transient. Limited data exist on anatomic factors predisposing to pacemaker dependency after TAVR. We sought to assess the rate and the possible predictors of pacemaker dependency after TAVR. METHODS: Consecutive patients undergoing pacemaker implantation up to 30 days after TAVR between May 2014 and September 2019 were included. Baseline electrocardiographic, computed tomography, and procedural characteristics were collected, including valve implantation depth and membranous septum length, an anatomic surrogate of the distance between the aortic annulus and the His bundle. Pacemaker dependency at 30 days and 1 year and all-cause mortality during follow-up were evaluated. RESULTS: Of 728 TAVR patients, 112 (53.5% men; median age, 81 years) underwent pacemaker implantation after TAVR. Of these, 44.6% (50 of 112) were pacemaker dependent at 30 days and 46.7% (36 of 77) at 1 year. By multivariate analysis, independent predictors of 30-day pacemaker dependency included left ventricular outflow tract calcifications under the left coronary cusp (odds ratio, 5.69 [95% CI, 1.45-22.31]; P=0.013) and a difference between membranous septum length and implantation depth (ΔMSID) ≥3 mm (odds ratio, 7.58 [95% CI, 2.07-27.78]; P=0.002). Conversely, membranous septum length and implantation depth alone were not associated with pacemaker dependency (odds ratio, 0.79 [95% CI, 0.60-1.05]; P=0.11 and odds ratio, 1.11 [95% CI, 0.99-1.24]; P=0.08). At a median follow-up of 28.1 (11.7-48.6) months, pacemaker-dependent patients did not show a worse survival (P=0.26). CONCLUSIONS: Less than half of the patients undergoing pacemaker implantation after TAVR are pacemaker-dependent at midterm follow-up. ΔMSID ≥3 mm and the presence of left ventricular outflow tract calcifications under the left coronary cusp, but not membranous septum length nor implantation depth alone, are predictive of long-term pacemaker dependency after TAVR, thus influencing device selection and programming.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Arritmias Cardíacas/prevención & control , Marcapaso Artificial , Complicaciones Posoperatorias/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Arritmias Cardíacas/etiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Pronóstico , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...