Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMC Geriatr ; 23(1): 737, 2023 11 13.
Artículo en Inglés | MEDLINE | ID: mdl-37957597

RESUMEN

BACKGROUND: There are a lot of tools to use for fall assessment, but there is not yet one that predicts the risk of falls in the elderly. This study aims to evaluate the use of the G-STRIDE prototype in the analysis of fall risk, defining the cut-off points to predict the risk of falling and developing a predictive model that allows discriminating between subjects with and without fall risks and those at risk of future falls. METHODS: An observational, multicenter case-control study was conducted with older people coming from two different public hospitals and three different nursing homes. We gathered clinical variables ( Short Physical Performance Battery (SPPB), Standardized Frailty Criteria, Speed 4 m walk, Falls Efficacy Scale-International (FES-I), Time-Up Go Test, and Global Deterioration Scale (GDS)) and measured gait kinematics using an inertial measure unit (IMU). We performed a logistic regression model using a training set of observations (70% of the participants) to predict the probability of falls. RESULTS: A total of 163 participants were included, 86 people with gait and balance disorders or falls and 77 without falls; 67,8% were females, with a mean age of 82,63 ± 6,01 years. G-STRIDE made it possible to measure gait parameters under normal living conditions. There are 46 cut-off values of conventional clinical parameters and those estimated with the G-STRIDE solution. A logistic regression mixed model, with four conventional and 2 kinematic variables allows us to identify people at risk of falls showing good predictive value with AUC of 77,6% (sensitivity 0,773 y specificity 0,780). In addition, we could predict the fallers in the test group (30% observations not in the model) with similar performance to conventional methods. CONCLUSIONS: The G-STRIDE IMU device allows to predict the risk of falls using a mixed model with an accuracy of 0,776 with similar performance to conventional model. This approach allows better precision, low cost and less infrastructures for an early intervention and prevention of future falls.


Asunto(s)
Marcha , Caminata , Anciano , Femenino , Humanos , Masculino , Accidentes por Caídas/prevención & control , Estudios de Casos y Controles , Equilibrio Postural , Medición de Riesgo/métodos , Sensibilidad y Especificidad , Anciano de 80 o más Años
2.
Sci Rep ; 13(1): 9208, 2023 06 06.
Artículo en Inglés | MEDLINE | ID: mdl-37280388

RESUMEN

Falls are one of the main concerns in the elderly population due to their high prevalence and associated consequences. Guidelines for the management of the elder with falls are comprised of multidimensional assessments, especially gait and balance. Daily clinical practice needs for timely, effortless, and precise tools to assess gait. This work presents the clinical validation of the G-STRIDE system, a 6-axis inertial measurement unit (IMU) with onboard processing algorithms, that allows the calculation of walking-related metrics correlated with clinical markers of fall risk. A cross-sectional case-control study was conducted with 163 participants (falls and non-falls groups). All volunteers were assessed with clinical scales and conducted a 15-min walking test at a self-selected pace while wearing the G-STRIDE. G-STRIDE is a low-cost solution to facilitate the transfer to society and clinical evaluations. It is open hardware and flexible and, thus, has the advantage of providing runtime data processing. Walking descriptors were derived from the device, and a correlation analysis was conducted between walking and clinical variables. G-STRIDE allowed measuring walking parameters in non-restricted walking conditions (e.g. hallway). Walking parameters statistically discriminate between falls and non-falls groups. We found good/excellent estimation accuracy (ICC = 0.885; [Formula: see text]) for walking speed, showing good/excellent correlation between gait speed and several clinical variables. G-STRIDE can calculate walking-related metrics that allow for discrimination between falls and non-falls groups, which correlates with clinical indicators of fall risk. A preliminary fall-risk assessment based on the walking parameters was found to improve the Timed Up and Go test in the identification of fallers.


Asunto(s)
Marcha , Equilibrio Postural , Humanos , Anciano , Estudios Transversales , Estudios de Casos y Controles , Estudios de Tiempo y Movimiento , Caminata
3.
Sensors (Basel) ; 23(2)2023 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-36679587

RESUMEN

Nowadays, robotic technology for gait training is becoming a common tool in rehabilitation hospitals. However, its effectiveness is still controversial. Traditional control strategies do not adequately integrate human intention and interaction and little is known regarding the impact of exoskeleton control strategies on muscle coordination, physical effort, and user acceptance. In this article, we benchmarked three types of exoskeleton control strategies in a sample of seven healthy volunteers: trajectory assistance (TC), compliant assistance (AC), and compliant assistance with EMG-Onset stepping control (OC), which allows the user to decide when to take a step during the walking cycle. This exploratory study was conducted within the EUROBENCH project facility. Experimental procedures and data analysis were conducted following EUROBENCH's protocols. Specifically, exoskeleton kinematics, muscle activation, heart and breathing rates, skin conductance, as well as user-perceived effort were analyzed. Our results show that the OC controller showed robust performance in detecting stepping intention even using a corrupt EMG acquisition channel. The AC and OC controllers resulted in similar kinematic alterations compared to the TC controller. Muscle synergies remained similar to the synergies found in the literature, although some changes in muscle contribution were found, as well as an overall increase in agonist-antagonist co-contraction. The OC condition led to the decreased mean duration of activation of synergies. These differences were not reflected in the overall physiological impact of walking or subjective perception. We conclude that, although the AC and OC walking conditions allowed the users to modulate their walking pattern, the application of these two controllers did not translate into significant changes in the overall physiological cost of walking nor the perceived experience of use. Nonetheless, results suggest that both AC and OC controllers are potentially interesting approaches that can be explored as gait rehabilitation tools. Furthermore, the INTENTION project is, to our knowledge, the first study to benchmark the effects on human-exoskeleton interaction of three different exoskeleton controllers, including a new EMG-based controller designed by us and never tested in previous studies, which has made it possible to provide valuable third-party feedback on the use of the EUROBENCH facility and testbed, enriching the apprenticeship of the project consortium and contributing to the scientific community.


Asunto(s)
Dispositivo Exoesqueleto , Humanos , Benchmarking , Músculo Esquelético/fisiología , Electromiografía/métodos , Caminata/fisiología , Marcha/fisiología , Fenómenos Biomecánicos/fisiología
4.
Sensors (Basel) ; 22(15)2022 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-35957207

RESUMEN

Current m-Health scenarios in the smart living era, as the interpretation of the smart city at each person's level, present several challenges associated with interoperability between different clinical devices and applications. The Continua Health Alliance establishes design guidelines to standardize application communication to guarantee interoperability among medical devices. In this paper, we describe the implementation of two IEEE agents for oxygen saturation level (SpO2) measurements and electrocardiogram (ECG) data acquisition, respectively, and a smartphone IEEE manager for validation. We developed both IEEE agents over the Bluetooth Health Device Profile following the Continua guidelines and they are part of a telemonitoring system. This system was evaluated in a sample composed of 10 volunteers (mean age 29.8 ± 7.1 y/o; 5 females) under supervision of an expert cardiologist. The evaluation consisted of measuring the SpO2 and ECG signal sitting and at rest, before and after exercising for 15 min. Physiological measurements were assessed and compared against commercial devices, and our expert physician did not find any relevant differences in the ECG signal. Additionally, the system was assessed when acquiring and processing different heart rate data to prove that warnings were generated when the heart rate was under/above the thresholds for bradycardia and tachycardia, respectively.


Asunto(s)
Saturación de Oxígeno , Telemedicina , Adulto , Atención a la Salud , Electrocardiografía , Femenino , Humanos , Teléfono Inteligente , Adulto Joven
5.
Sensors (Basel) ; 21(13)2021 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-34202786

RESUMEN

The high prevalence of falls and the enormous impact they have on the elderly population is a cause for concern. We aimed to develop a walking-monitor gait pattern (G-STRIDE) for older adults based on a 6-axis inertial measurement (IMU) with the application of pedestrian dead reckoning algorithms and tested its structural and clinical validity. A cross-sectional case-control study was conducted with 21 participants (11 fallers and 10 non-fallers). We measured gait using an IMU attached to the foot while participants walked around different grounds (indoor flooring, outdoor floor, asphalt, etc.). The G-STRIDE consisted of a portable inertial device that monitored the gait pattern and a mobile app for telematic clinical analysis. G-STRIDE made it possible to measure gait parameters under normal living conditions when walking without assessing the patient in the outpatient clinic. Moreover, we verified concurrent validity with convectional outcome measures using intraclass correlation coefficients (ICCs) and analyzed the differences between participants. G-STRIDE showed high estimation accuracy for the walking speed of the elderly and good concurrent validity compared to conventional measures (ICC = 0.69; p < 0.000). In conclusion, the developed inertial-based G-STRIDE can accurately classify older people with risk to fall with a significance as high as using traditional but more subjective clinical methods (gait speed, Timed Up and Go Test).


Asunto(s)
Accidentes por Caídas , Dispositivos Electrónicos Vestibles , Anciano , Estudios de Casos y Controles , Estudios Transversales , Marcha , Humanos , Proyectos Piloto , Equilibrio Postural , Estudios de Tiempo y Movimiento , Caminata
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...