Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
AJR Am J Roentgenol ; 218(1): 174-179, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34319163

RESUMEN

BACKGROUND. Extrinsic warming of iodinated CT contrast media to body temperature reduces viscosity and injection pressures. However, studies examining the effect of extrinsic warming on clinical adverse events are limited in number and provide conflicting results. Therefore, consensus practice recommendations have been sparse. OBJECTIVE. The purpose of this study is to compare rates of extravasation, allergic and allergiclike reactions, and physiologic reactions between iohexol 350 mg I/mL warmed to body temperature (37°C) versus this agent maintained at room temperature. METHODS. This retrospective study compared adult patients who received CT examinations using IV iohexol 350 that had either been warmed to body temperature or maintained at room temperature. At our institution, contrast media had historically been warmed to body temperature before a protocol change unrelated to this investigation. Information on the patient and CT examination was extracted from the electronic medical record. Adverse events, including extravasations, allergic and allergiclike reactions, and physiologic reactions, were compared between groups. RESULTS. A total of 3939 patients received contrast media warmed to body temperature before the protocol change; 3933 patients received contrast media at room temperature after the protocol change. The body temperature group experienced 11 (0.28%; 95% CI, 0.14-0.50%) adverse events, all extravasations; the allergic and allergic-like reaction rate was 0.00% (97.5% CI, 0.00-0.09%). The room temperature group experienced 17 (0.43%; 95% CI, 0.25-0.69%) adverse events: 13 (0.33%; 95% CI, 0.17-0.56%) extravasations and four (0.10%; 95% CI, 0.03-0.26%) allergic and allergiclike reactions. No physiologic reaction occurred in either group. The two groups were not different in terms of overall reaction rate (p = .19), extravasation rate (p = .69), allergic and allergiclike reaction rate (p = .06), or physiologic reaction rate (p > .99). Logistic regression adjusting for patient and CT characteristics (age, sex, conventional CT vs CTA, contrast media volume, injection location) showed no significant association of patient group and adverse reaction rate (odds ratio, 2.19; 95% CI, 0.68-7.00). Multivariable regression modeling showed an excess of 0.27 adverse events per 100 patients within the room temperature group, which is below a 0.6% noninferiority margin. CONCLUSION. The data suggest that maintaining iohexol 350 at room temperature is noninferior to warming the agent to body temperature before injection. CLINICAL IMPACT. The resources involved to prewarm iohexol 350 before injection may not be warranted.


Asunto(s)
Medios de Contraste/efectos adversos , Hipersensibilidad a las Drogas/prevención & control , Extravasación de Materiales Terapéuticos y Diagnósticos/prevención & control , Yohexol/efectos adversos , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Temperatura Corporal , Femenino , Calor , Humanos , Masculino , Persona de Mediana Edad , Concentración Osmolar , Estudios Retrospectivos
2.
Curr Probl Diagn Radiol ; 49(3): 173-176, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31126664

RESUMEN

BACKGROUND: Prostate imaging reporting and data system version 2 (PI-RADS v2) relegates dynamic contrast enhanced (DCE) imaging to a minor role. We sought to determine how often DCE is used in PI-RADS v2 scoring. MATERIALS AND METHODS: We retrospectively reviewed data from 388 patients who underwent prostate magnetic resonance imaging and subsequent biopsy from January 2016 through December 2017. In accordance with PI-RADS v2, DCE was deemed necessary if a peripheral-zone lesion had a diffusion-weighted imaging score of 3, or if a transition-zone lesion had a T2 score of 3 and diffusion-weighted imaging experienced technical failure. Receiver operating characteristic curve analysis assessed the accuracy of prostate-specific antigen density (PSAD) at different threshold values for differentiating lesions that would be equivocal with noncontrast technique. Accuracy of PSAD was compared to DCE using McNemar's test. RESULTS: Sixty-nine lesions in 62 patients (16%) required DCE for PI-RADS scoring. Biopsy of 10 (14%) of these lesions showed clinically significant cancer (Gleason score ≥7). In the subgroup of patients with equivocal lesions, those with clinically significant cancer had significantly higher PSADs than those with clinically insignificant lesions (means of 0.18 and 0.13 ng/mL/mL, respectively; P= 0.038). In this subgroup, there was no statistical difference in accuracy in determining clinically significant cancer between a PSAD threshold value of 0.13 and DCE (P= 0.25). CONCLUSIONS: Only 16% of our patients needed DCE to generate the PI-RADS version 2 score, raising the possibility of limiting the initial screening prostate MRI to a noncontrast exam. PSAD may also be used to further decrease the need for or to replace DCE altogether.


Asunto(s)
Medios de Contraste , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Sistemas de Información Radiológica/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Biopsia , Humanos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Próstata/diagnóstico por imagen , Próstata/patología , Neoplasias de la Próstata/patología , Reproducibilidad de los Resultados , Estudios Retrospectivos
3.
Curr Probl Diagn Radiol ; 48(1): 40-44, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29273558

RESUMEN

BACKGROUND: Breast cancer has the highest incidence of cancers in women in the United States. Previous research has shown that screening mammography contributes to reduced breast cancer mortality. This study aimed to clarify why late screening might occur in an at-risk population. MATERIALS AND METHODS: This study was a prospective cross-sectional study including 758 patients presenting to our radiology department for routine screening mammography who completed a 30-question survey regarding personal characteristics and mammography history. Univariate and multivariate logistic regression were performed to determine whether survey responses correlated with late screening. RESULTS: Of the 758 patients, 184 (24%) were noncompliant with screening mammography guidelines. Risk factors for late screening included younger age (P = 0.001), white race/ethnicity (P = 0.03), self-reported lack of financial means or health insurance (P = 0.005), lack of satisfaction with a previous mammogram experience (P = 0.001), inadequate mammography education by a physician (P = 0.001), and lack of awareness/comprehension of screening mammography guidelines (P = 0.002). CONCLUSION: Many factors contribute to late screening mammography. Although some are outside physician control, others can be influenced: patient education regarding screening mammography guidelines, and patient satisfaction with the mammography experience. This study highlights the importance of communication with and education of patients.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/psicología , Mamografía/psicología , Cooperación del Paciente , Estudios Transversales , Detección Precoz del Cáncer , Femenino , Humanos , Tamizaje Masivo , Persona de Mediana Edad , Educación del Paciente como Asunto , Satisfacción del Paciente , Estudios Prospectivos , Factores de Riesgo , Encuestas y Cuestionarios
4.
J Magn Reson Imaging ; 49(4): 984-993, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30390358

RESUMEN

BACKGROUND: View-sharing (VS) increases spatiotemporal resolution in dynamic contrast-enhanced (DCE) MRI by sharing high-frequency k-space data across temporal phases. This temporal sharing results in respiratory motion within any phase to propagate artifacts across all shared phases. Compressed sensing (CS) eliminates the need for VS by recovering missing k-space data from pseudorandom undersampling, reducing temporal blurring while maintaining spatial resolution. PURPOSE: To evaluate a CS reconstruction algorithm on undersampled DCE-MRI data for image quality and hepatocellular carcinoma (HCC) detection. STUDY TYPE: Retrospective. SUBJECTS: Fifty consecutive patients undergoing MRI for HCC screening (29 males, 21 females, 52-72 years). FIELD STRENGTH/SEQUENCE: 3.0T MRI. Multiphase 3D-SPGR T1 -weighted sequence undersampled in arterial phases with a complementary Poisson disc sampling pattern reconstructed with VS and CS algorithms. ASSESSMENT: VS and CS reconstructions evaluated by blinded assessments of image quality and anatomic delineation on Likert scales (1-4 and 1-5, respectively), and HCC detection by OPTN/UNOS criteria including a diagnostic confidence score (1-5). Blinded side-by-side reconstruction comparisons for lesion depiction and overall series preference (-3-3). STATISTICAL ANALYSIS: Two-tailed Wilcoxon signed rank tests for paired nonparametric analyses with Bonferroni-Holm multiple-comparison corrections. McNemar's test for differences in lesion detection frequency and transplantation eligibility. RESULTS: CS compared with VS demonstrated significantly improved contrast (mean 3.6 vs. 2.9, P < 0.0001) and less motion artifact (mean 3.6 vs. 3.2, P = 0.006). CS compared with VS demonstrated significantly improved delineations of liver margin (mean 4.5 vs. 3.8, P = 0.0002), portal veins (mean 4.5 vs. 3.7, P < 0.0001), and hepatic veins (mean 4.6 vs. 3.5, P < 0.0001), but significantly decreased delineation of hepatic arteries (mean 3.2 vs. 3.7, P = 0.004). No significant differences were seen in the other assessments. DATA CONCLUSION: Applying a CS reconstruction to data acquired for a VS reconstruction significantly reduces motion artifacts in a clinical DCE protocol for HCC screening. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:984-993.


Asunto(s)
Artefactos , Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Anciano , Algoritmos , Medios de Contraste , Compresión de Datos , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Movimiento (Física) , Variaciones Dependientes del Observador , Reconocimiento de Normas Patrones Automatizadas , Respiración , Estudios Retrospectivos
5.
Abdom Radiol (NY) ; 44(1): 22-30, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30066168

RESUMEN

PURPOSE: Magnetic resonance imaging (MRI) sequences with conical k-space trajectories are able to decrease motion artifacts while achieving ultrashort echo times (UTE). We assessed the performance of free-breathing conical UTE MRI in the evaluation of the pediatric pelvis for suspected appendicitis. METHODS: Our retrospective review of 84 pediatric patients who underwent MRI for suspected appendicitis compared three contrast-enhanced sequences: free-breathing conical UTE, breath-hold three-dimensional (3D) spoiled gradient echo (BH-SPGR), and free-breathing high-resolution 3D SPGR (FB-SPGR). Two radiologists performed blinded and independent evaluations of each sequence for image quality (four point scale), anatomic delineation (four point scale), and diagnostic confidence (five point scale). Subsequently, the three sequences were directly compared for overall image quality (- 3 to + 3 scale). Scores were compared using Kruskal-Wallis and Wilcoxon signed-rank tests. RESULTS: UTE demonstrated significantly better perceived signal-to-noise ratio (SNR) and fewer artifacts than BH-SPGR and FB-SPGR (means of 3.6 and 3.4, 3.4 and 3.2, 3.1 and 2.7, respectively; p < 0.0006). BH-SPGR and FB-SPGR demonstrated significantly better contrast than UTE (means of 3.6, 3.4, and 3.2, respectively; p < 0.03). In the remaining categories, UTE performed significantly better than FB-SPGR (p < 0.00001), while there was no statistical difference between UTE and BH-SPGR. Direct paired comparisons of overall image quality demonstrated the readers significantly preferred UTE over both BH-SPGR (mean + 0.5, p < 0.00001) and FB-SPGR (mean + 1.2, p < 0.00001). CONCLUSIONS: In the evaluation of suspected appendicitis, free-breathing conical UTE MRI performed better in the assessed metrics than FB-SPGR. When compared to BH-SPGR, UTE demonstrated superior perceived SNR and fewer artifacts.


Asunto(s)
Apendicitis/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Enfermedad Aguda , Adolescente , Apéndice/diagnóstico por imagen , Artefactos , Niño , Preescolar , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Relación Señal-Ruido
6.
Am J Emerg Med ; 36(4): 677-679, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29395769

RESUMEN

OBJECTIVES: To determine if a physician-patient language barrier impacts the diagnostic accuracy of pulmonary embolism (PE) evaluation. METHODS: A retrospective chart review, conducted between June 2015 and December 2016, of a consecutive sample of diagnostic computed tomography pulmonary angiogram (CTPA) studies performed on adult patients. Positive and negative CTPA scans were further categorized by patient language and the positive diagnostic yield was determined for each language group. A post collection sub-analysis was performed to determine the yield when interpreter services were identified as necessary. RESULTS: The yield for English speaking patients was 10.24% (92/898, 95% CI 8.39% to 12.36%), similar to the yield in Spanish speaking patients of 9.40% (25/266, 95% CI 6.31% to 13.37%, P=0.69). This contrasted with the yield in patients who identified as bilingual, which was significantly lower at 1.41% (1/71, 95% CI 0.07% to 6.75%) compared to both English-(P<0.02) and Spanish-only speakers (P<0.03). The yield for non-English speaking patients who requested an interpreter was 7.37% (14/190, 95% CI 4.26% to 11.77%) versus 3.23% (2/62, 95% CI 0.54% to 10.25%, P=0.25) in those who did not. CONCLUSIONS: The diagnostic yield in English- and Spanish-only speaking patients was similar, however, the yield in those that self-identified as bilingual was significantly lower. In patient groups in which a language barrier existed and an interpreter was not utilized, there was a trend toward a lower diagnostic yield. This suggests an increased propensity to order diagnostic imaging when potential communication barriers exist.


Asunto(s)
Barreras de Comunicación , Angiografía por Tomografía Computarizada , Relaciones Médico-Paciente , Embolia Pulmonar/diagnóstico por imagen , Hispánicos o Latinos , Humanos , Estudios Retrospectivos , Medición de Riesgo/etnología
7.
Pediatr Radiol ; 47(3): 301-305, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28091700

RESUMEN

BACKGROUND: Computed tomography (CT) is commonly used to evaluate suspected acute appendicitis. Although very effective, CT uses ionizing radiation, exposing patients to an increased risk of cancer. OBJECTIVE: This study assessed the potential for decreasing the field of view of the CT (and therefore the dose to the patient) in the evaluation of suspected acute appendicitis in children. MATERIALS AND METHODS: This study was a retrospective review of prospectively collected data from 212 consecutive patients who underwent CT for suspected acute appendicitis. The most superior aspect of the appendix with respect to vertebral bodies was recorded. Age, gender and diagnosis (negative, acute appendicitis or alternative diagnosis) were noted. RESULTS: The appendix was visualized in 190 of 212 subjects (89.6%). Overall, all visualized appendixes were located at or below the level of L1. Sixty-three of the subjects (29.7%) were diagnosed with acute appendicitis via CT imaging. All appendixes in patients with acute appendicitis were located at or below the level of the L3 vertebral body, predominating at the level of L5. Six subjects (3.1%) received alternative diagnoses, including pneumonia, pyelonephritis, small bowel obstruction and infected urachal cyst. There were no differences in appendix location with regard to diagnosis, gender, or age (P=0.664, 0.748 and 0.705, respectively). CONCLUSION: CT field of view may be decreased to the level of L1 or L3 superiorly, decreasing radiation dose without affecting the rate of appendix visualization.


Asunto(s)
Apendicitis/diagnóstico por imagen , Apéndice/anatomía & histología , Vértebras Lumbares/anatomía & histología , Tomografía Computarizada por Rayos X/métodos , Adolescente , Puntos Anatómicos de Referencia , Niño , Medios de Contraste , Diagnóstico Diferencial , Femenino , Humanos , Yopamidol , Masculino , Exposición a la Radiación , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...