Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Am Heart J Plus ; 42: 100391, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38680648

RESUMEN

This article provides a summary of the clinical spectrum of no obstructive coronary arteries. We describe the pathologies, invasive and noninvasive assessment, and management strategies.

3.
Tex Heart Inst J ; 48(3)2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243189

RESUMEN

Aortic insufficiency with recirculation can be difficult to diagnose echocardiographically in patients who have continuous-flow left ventricular assist devices. Transthoracic and transesophageal echocardiography can underestimate its severity; moreover, transesophageal echocardiography necessitates general anesthesia. We report the case of a 58-year-old man with obesity and end-stage nonischemic cardiomyopathy who, after 3 months of support with a continuous-flow left ventricular assist device, underwent intracardiac echocardiography to evaluate complications potentially associated with the device. The findings ruled out aortic insufficiency, preventing an unnecessary valvular intervention.


Asunto(s)
Ecocardiografía/métodos , Insuficiencia Cardíaca/diagnóstico , Ventrículos Cardíacos/diagnóstico por imagen , Corazón Auxiliar , Obesidad/complicaciones , Función Ventricular Izquierda/fisiología , Progresión de la Enfermedad , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Índice de Severidad de la Enfermedad
4.
Catheter Cardiovasc Interv ; 97(4): 736-742, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33427384

RESUMEN

BACKGROUND: Transcatheter aortic valve-in-valve replacement (ViV) has been widely accepted as a less invasive alternative to treat failed aortic surgical or transcatheter bioprosthetic valves. Angulated aortas present an additional challenge, particularly when using self-expanding transcatheter heart valves (SE-THV). METHODS: Two patients with failed surgical bioprosthetic aortic valves and one patient with a failed transcatheter bioprosthetic aortic valve underwent transcatheter aortic ViV using SE-THV. All were deemed high-risk for surgical aortic valve replacement by a heart team. All three patients had initial failed SE-THV delivery using a conventional approach with subsequent successful delivery using the endovascular snare technique. RESULTS: In Cases 1 and 2, the SE-THV was biased towards the greater curve of the angulated aorta and behind the outer frame of the bioprosthetic valve frame. An endovascular snare was deployed through a secondary left femoral artery access, and the valve delivery system was advanced through the snare in the ascending aorta. The snare was tightened around the SE-THV capsule proximal to the hat-marker, allowing deflection of the SE-THV and successful delivery. In Case 3, the SE-THV interacted with the tall frame of a failed SE-THV. A snare via the left femoral artery was deployed in the descending artery. The SE-THV was advanced through the snare, and both the snare and SE-THV were advanced together to the ascending aorta where the SE-THV was deflected and successfully delivered. CONCLUSIONS: The endovascular snare technique is a feasible option for successful delivery of SE-THV during transcatheter aortic ViV in failed transcatheter or surgical bioprosthetic valves in angulated aortas.


Asunto(s)
Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Aorta , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
Cardiovasc Revasc Med ; 31: 71-75, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33309042

RESUMEN

BACKGROUND: Vasopressors and inotropes are the primary pharmacologic agents in the management of cardiogenic shock. Increased use of these agents in the setting of cardiogenic shock treated with the Impella is associated with increased mortality. This study evaluates the use of vasopressors and inotropes as predictors of mortality in patients treated with the Impella for acute cardiogenic shock. METHODS: This retrospective study included 276 patients treated with the Impella 2.5, Impella CP, or Impella 5.0 from March 2011 to January 2020 at a single, tertiary referral center for acute cardiogenic shock. RESULTS: All-cause in-hospital mortality was 44.6%. Mortality significantly increased with escalating use of vasopressors and inotropes, with the most significant increase in mortality from use of 2 agents to the use of 3 agents (8.1% vs 39.7%, p < 0.001). There was no difference in mortality whether dobutamine or milrinone was used (44.4% vs 35.7%, p = 0.41); there was increased mortality with use of multiple inotropes. Patients treated with only vasopressors had increased mortality compared to those treated with a combination of agents that included 1 inotrope. CONCLUSIONS: The escalating need for vasopressors and inotropes and particular combinations of these agents are significant predictors of mortality that may help determine whether the Impella or higher level of support is more appropriate to treat acute cardiogenic shock.


Asunto(s)
Corazón Auxiliar , Choque Cardiogénico , Mortalidad Hospitalaria , Humanos , Estudios Retrospectivos , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/tratamiento farmacológico , Resultado del Tratamiento , Vasoconstrictores/efectos adversos
6.
BMJ Case Rep ; 12(12)2019 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-31796451

RESUMEN

Hypocupremia is a rare and under-recognised cause of bone marrow dysplasia and myeloneuropathy. A 47-year-old Caucasian woman had progressive ascending peripheral neuropathy and gait ataxia over 3 months and fatigue, dyspnoea and unintentional weight loss over 8 months. She had profound macrocytic anaemia and neutropenia. Initial workup included normal serum vitamin B12 Bone marrow biopsy was suggestive of copper deficiency. Serum copper levels were later confirmed to be undetectable. The patient received oral copper repletion which resulted in complete normalisation of haematological abnormalities 16 weeks later. However, neurological deficits persisted. This case describes a delayed diagnosis of hypocupremia as initially suggested through invasive testing. Associating myeloneuropathy with cytopenia is imperative for accurate and prompt diagnosis of hypocupremia, which can be confirmed by serum analysis alone. Developing an accurate differential diagnosis can help prevent unnecessary procedures. Furthermore, initiating prompt copper repletion prevents further neurological impairment. Neurological deficits are often irreversible.


Asunto(s)
Cobre/deficiencia , Cementos Dentales/efectos adversos , Ataxia de la Marcha/etiología , Zinc/efectos adversos , Anemia Macrocítica/sangre , Anemia Macrocítica/complicaciones , Médula Ósea/patología , Cobre/administración & dosificación , Femenino , Humanos , Persona de Mediana Edad , Neutropenia/sangre
7.
SAGE Open Med Case Rep ; 7: 2050313X19869473, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31452889

RESUMEN

Gastric mucosa-associated lymphoid tissue lymphoma is a rare clonal B-cell neoplasm that is usually associated with Helicobacter pylori infection. The presence of H. pylori should be confirmed via special stains and/or immunohistochemistry of gastric biopsies from multiple anatomic sites of the stomach. Mucosa-associated lymphoid tissue lymphoma is diagnosed with histopathologic examination and positive immunohistochemical staining for certain B-cell markers. Ancillary testing should be performed to determine any genetic abnormalities in H. pylori that increases its virulence. We report the case of a 49-year-old woman with recurrent epigastric pain and vomiting found to have chronic H. pylori gastritis despite appropriate rounds of treatment with first-line therapy. She was diagnosed with mucosa-associated lymphoid tissue lymphoma via histopathologic examination. She ultimately required oncological treatment due to H. pylori infection refractory to antibiotic treatment.

8.
Am J Cardiol ; 124(4): 499-504, 2019 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-31262498

RESUMEN

The Impella (Abiomed, Danvers, Massachusetts) device is increasingly used for mechanical circulatory support (MCS) to treat acute severe cardiogenic shock (CS). Initial and continued determination of the appropriate degree of MCS is challenging. This study evaluates predictors of mortality in patients treated with the Impella for acute severe CS and outcomes associated with prolonged Impella use. This retrospective single-center study included 204 patients treated with the Impella 2.5, Impella CP, or Impella 5.0 from 2011 to 2018 for acute severe CS. The primary end point was all-cause in-hospital mortality. All-cause in-hospital mortality was 45.1%. Nonsurvivors had a lower initial pH (7.24 vs 7.32, hazard ratio [HR] 1.03, p <0.0001), lower serum CO2 (19.1 vs 21.3 mmol/L, HR 1.08, p = 0.002), higher lactate (6.8 vs 3.3 mmol/L, HR 1.17, p <0.0001), and used a greater number of vasopressors and inotropes (4.3 vs 2.6, HR 1.44, p <0.0001). Patients with the Impella >4 days (n = 45) had a longer intensive care unit stay (12.6 vs 6.9 days, p <0.001), longer total hospital stay (16.4 vs 11.6 days, p = 0.03), longer mechanical ventilation use (7.8 vs 4.4 days, p = 0.002), and trend toward increased mortality (57.8 vs 41.5%, p = 0.051). In conclusion, in patients treated with the Impella for acute severe CS, initial biochemical parameters and need for vasopressors and inotropes are significant predictors of mortality that can serve as valuable indicators of whether the Impella or higher level of MCS is more appropriate. Patients treated with the Impella beyond 4 days have poorer outcomes and may benefit from escalation of care.


Asunto(s)
Circulación Asistida/métodos , Cardiotónicos/uso terapéutico , Corazón Auxiliar , Mortalidad Hospitalaria , Choque Cardiogénico/terapia , Vasoconstrictores/uso terapéutico , Anciano , Circulación Asistida/instrumentación , Dióxido de Carbono/sangre , Femenino , Paro Cardíaco/complicaciones , Humanos , Concentración de Iones de Hidrógeno , Ácido Láctico/sangre , Tiempo de Internación , Masculino , Persona de Mediana Edad , Infarto del Miocardio sin Elevación del ST/complicaciones , Pronóstico , Modelos de Riesgos Proporcionales , Respiración Artificial/estadística & datos numéricos , Estudios Retrospectivos , Infarto del Miocardio con Elevación del ST/complicaciones , Choque Cardiogénico/sangre , Choque Cardiogénico/etiología
9.
Case Rep Med ; 2019: 2975131, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31178913

RESUMEN

Goodpasture syndrome is a rare autoimmune disease comprising antiglomerular basement membrane (anti-GBM) crescentic glomerulonephritis and pulmonary capillaritis with circulating anti-GBM antibodies. Rarely, antibody-negative cases have been described. We report a young, African American adult woman admitted with flank pain and hematuria with laboratory testing and kidney biopsy demonstrating anti-GBM crescentic glomerulonephritis with elevated anti-GBM antibody levels. She received treatment but remained dialysis-dependent. She was seronegative and clinically stable until she presented 8 months later with dyspnea and hemoptysis requiring mechanical ventilation. Bronchoscopy revealed diffuse alveolar hemorrhage. She was treated for relapse of Goodpasture syndrome. However, anti-GBM antibodies were undetectable. This case emphasizes prompt diagnosis and treatment of Goodpasture syndrome to preserve renal function. Additionally, clinical manifestations of Goodpasture syndrome and its degree of activity do not necessarily correlate with the actual antibody titer on relapse. Clinicians should have enhanced awareness of this atypical presentation of a rare disease.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...