1.
Heart ; 102(20): 1662-70, 2016 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-27296239

RESUMEN

OBJECTIVE: A safety threshold for baseline rhythm R-wave amplitudes during follow-up of implantable cardioverter defibrillators (ICD) has not been established. We aimed to analyse the amplitude distribution and undersensing rate during spontaneous episodes of ventricular fibrillation (VF), and define a safety amplitude threshold for baseline R-waves. METHODS: Data were obtained from an observational multicentre registry conducted at 48 centres in Spain. Baseline R-wave amplitudes and VF events were prospectively registered by remote monitoring. Signal processing algorithms were used to compare amplitudes of baseline R-waves with VF R-waves. All undersensed R-waves after the blanking period (120 ms) were manually marked. RESULTS: We studied 2507 patients from August 2011 to September 2014, which yielded 229 VF episodes (cycle length 189.6±29.1 ms) from 83 patients that were suitable for R-wave comparisons (follow-up 2.7±2.6 years). The majority (77.6%) of VF R-waves (n=13953) showed lower amplitudes than the reference baseline R-wave. The decrease in VF amplitude was progressively attenuated among subgroups of baseline R-wave amplitude (≥17; ≥12 to <17; ≥7 to <12; ≥2.2 to <7 mV) from the highest to the lowest: median deviations -51.2% to +22.4%, respectively (p=0.027). There were no significant differences in undersensing rates of VF R-waves among subgroups. Both the normalised histogram distribution and the undersensing risk function obtained from the ≥2.2 to <7 mV subgroup enabled the prediction that baseline R-wave amplitudes ≤2.5 mV (interquartile range: 2.3-2.8 mV) may lead to ≥25% of undersensed VF R-waves. CONCLUSIONS: Baseline R-wave amplitudes ≤2.5 mV during follow-up of patients with ICDs may lead to high risk of delayed detection of VF. TRIAL REGISTRATION NUMBER: NCT01561144; results.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Sistema de Conducción Cardíaco/fisiopatología , Fibrilación Ventricular/terapia , Potenciales de Acción , Adulto , Anciano , Diagnóstico Tardío , Cardioversión Eléctrica/efectos adversos , Electrocardiografía/métodos , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Valor Predictivo de las Pruebas , Diseño de Prótesis , Sistema de Registros , Tecnología de Sensores Remotos/métodos , Factores de Riesgo , Procesamiento de Señales Asistido por Computador , España , Telemetría/métodos , Factores de Tiempo , Resultado del Tratamiento , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/fisiopatología
2.
IEEE J Biomed Health Inform ; 19(4): 1253-63, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25823046

RESUMEN

The current development of cloud computing is completely changing the paradigm of data knowledge extraction in huge databases. An example of this technology in the cardiac arrhythmia field is the SCOOP platform, a national-level scientific cloud-based big data service for implantable cardioverter defibrillators. In this scenario, we here propose a new methodology for automatic classification of intracardiac electrograms (EGMs) in a cloud computing system, designed for minimal signal preprocessing. A new compression-based similarity measure (CSM) is created for low computational burden, so-called weighted fast compression distance, which provides better performance when compared with other CSMs in the literature. Using simple machine learning techniques, a set of 6848 EGMs extracted from SCOOP platform were classified into seven cardiac arrhythmia classes and one noise class, reaching near to 90% accuracy when previous patient arrhythmia information was available and 63% otherwise, hence overcoming in all cases the classification provided by the majority class. Results show that this methodology can be used as a high-quality service of cloud computing, providing support to physicians for improving the knowledge on patient diagnosis.


Asunto(s)
Arritmias Cardíacas/clasificación , Electrocardiografía/clasificación , Internet , Computación en Informática Médica , Arritmias Cardíacas/terapia , Bases de Datos Factuales , Desfibriladores Implantables , Humanos , Aprendizaje Automático , Sensibilidad y Especificidad
3.
IEEE Trans Biomed Eng ; 61(4): 1328-38, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24658256

RESUMEN

Although a number of methods have been proposed for T-Wave Alternans (TWA) detection and estimation, their performance strongly depends on their signal processing stages and on their free parameters tuning. The dependence of the system quality with respect to the main signal processing stages in TWA algorithms has not yet been studied. This study seeks to optimize the final performance of the system by successive comparisons of pairs of TWA analysis systems, with one single processing difference between them. For this purpose, a set of decision statistics are proposed to evaluate the performance, and a nonparametric hypothesis test (from Bootstrap resampling) is used to make systematic decisions. Both the temporal method (TM) and the spectral method (SM) are analyzed in this study. The experiments were carried out in two datasets: first, in semisynthetic signals with artificial alternant waves and added noise; second, in two public Holter databases with different documented risk of sudden cardiac death. For semisynthetic signals (SNR = 15 dB), after the optimization procedure, a reduction of 34.0% (TM) and 5.2% (SM) of the power of TWA amplitude estimation errors was achieved, and the power of error probability was reduced by 74.7% (SM). For Holter databases, appropriate tuning of several processing blocks, led to a larger intergroup separation between the two populations for TWA amplitude estimation. Our proposal can be used as a systematic procedure for signal processing block optimization in TWA algorithmic implementations.


Asunto(s)
Electrocardiografía/métodos , Procesamiento de Señales Asistido por Computador , Adulto , Análisis por Conglomerados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Adulto Joven
4.
IEEE Trans Med Imaging ; 25(8): 1037-43, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16894996

RESUMEN

Reliable noninvasive estimators of global left ventricular (LV) chamber function remain unavailable. We have previously demonstrated a potential relationship between color-Doppler M-mode (CDMM) images and two basic indices of LV function: peak-systolic elastance (Emax) and the time-constant of LV relaxation (tau). Thus, we hypothesized that these two indices could be estimated noninvasively by adequate postprocessing of CDMM recordings. A semiparametric regression (SR) version of support vector machine (SVM) is here proposed for building a blind model, capable of analyzing CDMM images automatically, as well as complementary clinical information. Simultaneous invasive and Doppler tracings were obtained in nine mini-pigs in a high-fidelity experimental setup. The model was developed using a test and validation leave-one-out design. Reasonably acceptable prediction accuracy was obtained for both Emax (intraclass correlation coefficient Ric, = 0.81) and tau (Ric, = 0.61). For the first time, a quantitative, noninvasive estimation of cardiovascular indices is addressed by processing Doppler-echocardiography recordings using a learning-from-samples method.


Asunto(s)
Inteligencia Artificial , Ecocardiografía Doppler en Color/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Isquemia Miocárdica/diagnóstico por imagen , Reconocimiento de Normas Patrones Automatizadas/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Algoritmos , Animales , Almacenamiento y Recuperación de la Información/métodos , Isquemia Miocárdica/complicaciones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Volumen Sistólico , Porcinos , Disfunción Ventricular Izquierda/etiología
5.
Europace ; 5(1): 77-82, 2003 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-12504645

RESUMEN

AIMS: Ventricular activation onset is faster in supraventricular beats than in ventricular rhythms. The aim of this study was to evaluate a criterion to differentiate supraventricular (SVT) from ventricular tachycardia (VT) based on the analysis of the initial voltage changes in ICD-stored morphology electrograms. METHODS: Far field ICD-stored EGMs were obtained from 68 VT and 38 SVT episodes in 16 patients. The first EGM peak was detected, three consecutive time epochs were defined within the preceding 80 ms window and the voltage changes with respect to a sinus template were analysed during each time period and combined into a single parameter for rhythm discrimination. RESULTS: The algorithm was tested in an independent validation group of 442 VT and 97 SVT spontaneous episodes obtained from 22 patients with a dual chamber ICD. The area under the receiver-operator characteristics (ROC) curve indicated that the arrhythmia separability with this method was 0.95 (tolerance interval: 0.85-0.99) and 0.98 (0.87-0.99) for the control and validation groups respectively. A specificity of 0.91 was obtained at 95% sensitivity in the validation group. CONCLUSION: The analysis of voltage changes during the initial ventricular activation process is feasible using the far field stored electrograms of an ICD system and yields a high sensitivity and specificity for arrhythmia discrimination.


Asunto(s)
Algoritmos , Desfibriladores Implantables , Electrocardiografía , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Redes Neurales de la Computación , Curva ROC , Sensibilidad y Especificidad , Factores de Tiempo