Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Rev Chir Orthop Reparatrice Appar Mot ; 94(7): 693-6, 2008 Nov.
Artículo en Francés | MEDLINE | ID: mdl-18984127

RESUMEN

We report two cases of ochronosis. This rare disease (1/1,000,000) transmitted by recessive autosomic inheritance results from an enzyme disorder. Clinically, the disease begins by black deposits in connective tissue followed by a group of symptoms, particularly involving the joints, and then destructive joint disease affecting the larger joints. Diagnosis is often established late. Early detection is important, preoperatively if possible, in order to avoid the serious complication of infectious endocarditis. These patients require adapted multidisciplinary care associating social support and symptomatic treatment. Drug therapy is currently under study and appears to provide effective symptom relief.


Asunto(s)
Enfermedades de los Cartílagos , Ocronosis , Enfermedades de los Cartílagos/diagnóstico , Enfermedades de los Cartílagos/cirugía , Humanos , Masculino , Persona de Mediana Edad , Ocronosis/diagnóstico , Ocronosis/cirugía
2.
Surg Radiol Anat ; 30(7): 557-62, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18523716

RESUMEN

BACKGROUND: Magnetic resonance imaging has become the method of choice to diagnose meniscal and ligament lesions of the knee. New approaches to the surgical treatment of partial anterior cruciate ligament tears led us to try to distinguish the two bundles of that ligament with MRI and to evaluate inter-observer agreement in different viewing planes. METHODS: Images of 50 right and 50 left ligament-intact knees were examined in the coronal and axial viewing planes. Each sequence was independently read by a radiologist and a medical student to note, in each viewing plane, the number of images in which the two-bundle structure of the ligament was clearly seen. Cohen's Kappa coefficients were used to determine inter-observer agreements. RESULTS: The percentage of sequences in which the two bundles were distinguished by the radiologist and the student on one image at least were 82 versus 73% in the coronal plane and 90 versus 93% in the axial plane, respectively. The average number of successive images with clear bundles was higher in the axial (2.7 vs. 1.7) than in the coronal plane (2.2 vs. 1). There was a poor inter-observer agreement in the coronal plane (k=0.176) but an intermediate agreement in the axial plane (k=0.385 or 0.522 depending on number pooling). CONCLUSIONS: The axial viewing plane seems more favourable to distinguish the two bundles of the anterior cruciate ligament with the best possible reproducibility. An oblique-axial plane is deemed to insure a clearer diagnosis of partial tears.


Asunto(s)
Ligamento Cruzado Anterior/anatomía & histología , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Femenino , Humanos , Imagen por Resonancia Magnética/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valores de Referencia , Estudios Retrospectivos , Adulto Joven
3.
Rev Chir Orthop Reparatrice Appar Mot ; 93(4): 344-50, 2007 Jun.
Artículo en Francés | MEDLINE | ID: mdl-17646815

RESUMEN

PURPOSE OF THE STUDY: This was a retrospective series of patients who underwent revision ligamentoplasty of the anterior cruciate ligament (ACL). We wanted to assess the functional outcome after this type of surgery and search for potential prognostic factors. MATERIAL AND METHODS: The series included 74 patients, mean age 34 years (range 21-59 years). The initial ligamentoplasty was performed with a synthetic ligament (n=16), an autograft (n=57) or an allograft (n=1). Differential laxity (KT-1000 maximal manual) was 7 +/- 2.5 mm. Anterior drawer was measured on the stress x-rays in 20 degrees flexion: medial 8 +/- 4.7 mm, lateral 8.3 +/- 4.9 mm. Mean time to revision surgery was 78 months. Reconstruction was performed arthroscopically in 69 knees. The implant used for the revision reconstruction was an autograft: patellar tendon (n=42), quadriceps tendon (n=15), hamstring tendon (n=13), patellar tendon and quadriceps tendon (MacInJones) (n=3), fascia lata (n=1). A meniscal tear was noted in 24 knees and a cartilage lesion in 35. RESULTS: Outcome was assessed at mean 21.2 months follow-up. The mean IKDC function score was 71.7 (range 21.8-100). 78% of patients considered their knee normal or nearly normal and 88% presented a positive Lachmann. Mean differential laxity measured with KT-1000 (maximal manual) was 2 +/- 1.7 mm. Stress x-rays revealed a mean differential laxity measured at 3.7 +/- 2.3 mm medially and 6.3 +/- 4.3 mm laterally. The presence of a meniscal lesion favored osteoarthritic degradation. Presence of chondral lesions altered the functional outcome significantly and limited resumption of sports activities. An initial repair using a synthetic ligament affected the functional outcome after revision surgery and favored or aggravated chondral lesions. DISCUSSION: The clinical results we have obtained with revision ACL ligamentoplasty are comparable to previous series reported in the literature. The functional outcome is not as good as after first-intention repair, especially if the initial plasty was done with a synthetic ligament and the knee presented meniscal or cartilage damage.


Asunto(s)
Ligamento Cruzado Anterior/cirugía , Adulto , Lesiones del Ligamento Cruzado Anterior , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Ortopédicos/métodos , Reoperación , Estudios Retrospectivos
4.
Rev Chir Orthop Reparatrice Appar Mot ; 92(7): 680-91, 2006 Nov.
Artículo en Francés | MEDLINE | ID: mdl-17124452

RESUMEN

PURPOSE OF THE STUDY: Chronic tears of both cruciate ligaments are rarely encountered. Management practices have varied. One-stage reconstruction of both ligaments using arthroscopically implanted allografts was proposed starting in 1996 for such chronic laxity but only 44 cases have been reported in six papers mixed in with recent cases raising very different problems. Treatments using allografts or autogenous grafts or both implanted arthroscopically have often been combined with open surgery. We report a retrospective analysis of 25 knees treated with the same technique from 1983 to 2004: reconstruction with a single transplant taken from the extensor system. MATERIAL AND METHODS: A 30-cm lenght patella tendon-patella-quadriceps tendon graft was harvested. The patellar block was fixed in a hole drilled under the tibial spine, the patellar tendon replacing the posterior cruciate ligament and the quadriceps tendon passing through the lateral condyle and replacing the anterior cruciate ligament before implantation on Gerdy's tubercle, this also creating an extra-articular plasty with the same implant. Medial, lateral and posterior plasties were performed, depending on the radiographic assessment of laxity. Twenty-five knees with major laxity and instability were operated on, including 14 in two-stage operations. The differential anterior drawer was 10+/-3 mm medially and 9+/-5 mm laterally. The posterior drawer at 70 degrees was 15+/-4 mm medially and 10+/-6 degrees laterally. The total anteroposterior laxity of the medial compartment was 29 mm, it was 30 mm for the lateral compartment. Lateral laxity was considered major (>10 degrees ) in 17 knees and medial laxity in 7. Lateral and medial laxities were associated in eleven knees. Hyper-extension was very severe in five knees. RESULTS: Functional outcome at mean 6.5 years follow-up (range 1-21) was satisfactory (except in three knees) allowing renewed occupational activity. Resumption of sports activity was less marked and none of the knees was in IKDC class A, corroborating results in the literature. Anatomic outcome was assessed on the radiological drawer decrease which was modest, mean gain in the anterior drawer measuring 4 and 5 mm in the medial and lateral compartments and mean gain in the posterior drawer measuring 5 mm medially and 3 mm laterally. Peripheral laxity was corrected for best. DISCUSSION: Classically, one or other of the cruciate ligaments is repaired, sometimes both, but in a two-stage procedure associating two different methods and autogenous tendon grafts. One-stage reconstruction of both cruciate ligaments with a single autogenous graft and a wide approach has not led to any complications. One-stage reconstruction using this technique has several advantages: one anterior incision, single transplant which also enables lateral plasty, short immobilization time with rapid rehabilitation.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/cirugía , Inestabilidad de la Articulación/cirugía , Articulación de la Rodilla , Procedimientos Ortopédicos/métodos , Ligamento Rotuliano/trasplante , Ligamento Cruzado Posterior/lesiones , Ligamento Cruzado Posterior/cirugía , Adolescente , Adulto , Enfermedad Crónica , Femenino , Humanos , Masculino , Estudios Retrospectivos
5.
Rev Chir Orthop Reparatrice Appar Mot ; 92(3): 248-56, 2006 May.
Artículo en Francés | MEDLINE | ID: mdl-16910607

RESUMEN

PURPOSE OF THE STUDY: Short-term functional results and long-term outcome in terms of stability and wear greatly depend on the precision of the bone cuts. We wanted to know whether conventional ancillaries are still competitive in terms of accuracy in comparison with computer-assisted navigation systems. A few comparative studies favor navigation, but have generally only included a small number of patients. We studied radiographically a prospective consecutive series of 300 total knee prostheses (Innex, Zimmer) implanted with the conventional technique by the same operator. MATERIAL AND METHODS: A telegonometric view in the upright position and a short lateral view were obtained in all patients. In the AP view, implants were measured in comparison with the mechanical axis of the femur (F) and the tibia (T). On the lateral view, the prosthesis-tibial shaft angle (PT) was measured from the proximal portion of the tibial shaft and the prosthesis-femoral shaft angle (PF) from the distal portion of the femur. The same operator made all measurements using the same optimal conditions. The series included 178 women and 122 men, mean age 72 +/- 8 years who presented genu varum (n = 248 knees) and genu valgum (n = 52 knees): degenerative disease (n = 238), polyarthritis (n = 4), hemophilic arthropathy (n = 3), necrosis (n = 3), revision of unicompartmental prosthesis (n = 8), and osteotomy (n = 44). RESULTS: The standard x-ray protocol was performed at two months in all patients. The mechanical axis (HKA) was 179.4 +/- 2.4 degrees (range 173-186 degrees) and was +/- 3 degrees in 87% of knees with no difference for varum and valgum. F was 90.1 +/- 1.4 degrees (87-95), with +/- 3 degrees for 98.7%. T was 89.3 +/- 1.5 degrees (85-94) with +/- 3 degrees for 95.6%. PF was 88.6 +/- 1.6 degrees (84-93) for 87%, PT was 87 +/- 2 degrees (81-93) with +/- 3 degrees for 94%. The four cuts were within +/- 3 degrees for 227 prostheses (77%), within +/- 2 degrees for 156 (52%) and within +/- 1 degrees for 56 (18%). Measurements made again one year after implantation for 203 knees gave the same results. Operative time for implantation was 68 +/- 23 minutes for implantation and 85 +/- 23 minutes including complete closure (less than 60 minutes for 68 knees). DISCUSSION: The accuracy of each cut was satisfactory on average with a small standard deviation. Recent data in the literature show that the accuracy in our series is comparable with that obtained currently with navigation systems. In light of this experience, it can be seen that better precision can be achieved for each of the cuts. CONCLUSION: The accuracy of conventional instrumentation systems is still comparable with that obtained with computer-assisted surgery. The purpose of this study was not to question the benefit of navigation, but to establish a basis upon which progress can be measured. The results enabled a more realistic comparison of the precision of navigation systems and also can be comforting for operators still using conventional ancillaries.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artritis/cirugía , Artroplastia de Reemplazo de Rodilla/instrumentación , Femenino , Fémur/diagnóstico por imagen , Fémur/cirugía , Estudios de Seguimiento , Hemartrosis/cirugía , Humanos , Artropatías/cirugía , Prótesis Articulares , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Osteoartritis/cirugía , Osteonecrosis/cirugía , Osteotomía , Estudios Prospectivos , Radiografía , Reoperación , Cirugía Asistida por Computador , Tibia/diagnóstico por imagen , Tibia/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA