RESUMEN
OBJECTIVE: To compare fetal upper arm and thigh volume measurements acquired by three-dimensional (3D) ultrasound using the multiplanar and the eXtended Imaging Virtual Organ Computer-aided AnaLysis (XI VOCAL) methods with different number of sectional planes. METHODS: This study enrolled 40 healthy pregnant women between 20 and 40 weeks of gestation. The volume of fetal limbs was calculated using the multiplanar (with 5.0 mm intervals) and the XI VOCAL (with 5, 10, 15, and 20 slice planes) methods. Comparison between the techniques was made by analysis of variance and Bonferroni statistical tests. RESULTS: Mean fetal upper arm volume measured by the 15 sectional planes XI VOCAL method was lower than the same method using 5 and 10 planes instead (pâ=â0.025 and 0.039, respectively). Fetal thigh volume showed no statistically significant differences among all studied methods. CONCLUSION: The XI VOCAL using 15 sectional planes method underestimated the fetal upper arm volume by 5 and 10 planes XI VOCAL techniques.
Asunto(s)
Brazo/diagnóstico por imagen , Imagenología Tridimensional/métodos , Muslo/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Adulto , Anatomía Transversal/métodos , Brazo/embriología , Brazo/crecimiento & desarrollo , Estudios Transversales , Femenino , Feto/anatomía & histología , Edad Gestacional , Humanos , Tamaño de los Órganos , Embarazo , Muslo/embriología , Muslo/crecimiento & desarrollo , Adulto JovenRESUMEN
OBJECTIVES: The aim of this study was to evaluate feasibility of fetal lateral ventricle (LV) volumetry in fetuses with ventriculomegaly and to compare measurements performed by 3D sonographic method virtual organ computer-aided analysis (VOCAL) with those obtained by magnetic resonance imaging (MRI). METHODS: This cross-sectional study evaluated 30 fetuses with atrial width (AW) between 10 and 30 mm, from 20 to 36 gestational weeks. Fifty-nine ventricles were measured by two observers. Sonographic volumetric measurements using VOCAL 30° were performed with an ACCUVIX XQ machine (Medison, Korea) and MRI assessments with a Sonata system using ARGUS software (Siemens, Germany). Agreement between both techniques was assessed by intraclass correlation coefficient (ICC) calculation, and proportionate Bland-Altman plots were constructed. RESULTS: A high degree of reliability was observed between VOCAL and MRI measurements (ICC 0.928, 95%CI [0.876;0.958]). Bland-Altman plots confirmed the high correlation (mean of differences: 1.62 cm(3) and standard deviation: ± 8.41 cm(3)). CONCLUSION: Three-dimensional volumetry of fetal LVs by VOCAL method has good agreement with fetal MRI in fetuses with ventriculomegaly and may be used as an additional tool in patient counseling and prognosis prediction.
Asunto(s)
Ventrículos Cerebrales/embriología , Hidrocefalia/embriología , Imagen por Resonancia Magnética , Ultrasonografía Prenatal , Adolescente , Adulto , Ventrículos Cerebrales/diagnóstico por imagen , Estudios Transversales , Femenino , Humanos , Hidrocefalia/diagnóstico por imagen , Hidrocefalia/patología , Masculino , Embarazo , Pronóstico , Ultrasonografía Prenatal/métodosRESUMEN
BACKGROUND: To assess the reliability of fetal heart volume measurement by three-dimensional sonography (3DUS) using the eXtended Imaging Virtual Organ Computer-aided AnaLysis (XI VOCAL) method. METHODS: This reliability study enrolled 30 pregnant women with singleton healthy pregnancies between 19 and 34 weeks of gestation. All volume acquirements were performed with a convex volumetric transducer (C3-7ED) coupled to an Accuvix XQ sonography device (Medison, Korea). The XI VOCAL 10 planes was the method of choice for volumetric measurement. 3D datasets were analyzed by two observers (EQSB and HJFM); fetal heart volume was measured twice by the first and once by the second observer to calculate intra and interobserver reproducibility. Statistical analysis used pareated Student's t test (p) and calculated Intraclass correlation coefficients (ICC). Bland-Altman plots were also constructed. RESULTS: We observed an excellent intra- and interobserver reliability for fetal cardiac volume assessed by XI VOCAL. For the intraobserver the ICC was 0.998 (95% CI: 0.997; 0.999), with mean of differences of 0.12 cm3 (95% limits of agreement: -0.84; +0.84; p = 0.130). For interobserver the ICC was 0.899 (95%CI: 0.996; 0.998), mean of differences 0.05 cm3 (95% limits of agreement: -0.84; +0.84; p = 0.175). CONCLUSION: Fetal cardiac volume assessed by 3DUS using XI VOCAL method is highly reproducible between 19 to 34 gestational weeks.