Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Cutan Pathol ; 51(8): 572-575, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38661100

RESUMEN

Neurotrophic receptor tyrosine kinase (NTRK)-rearranged spindle cell neoplasms are a recently described group of soft tissue tumors. They commonly present as a painless mass on the extremities of children and young adults. They are characterized microscopically by a heterogeneous spectrum of infiltrative spindle cell proliferations, which can morphologically mimic several other spindle cell neoplasms. Their identification is vital, as they may be amenable to treatment with tyrosine kinase-targeted therapy. This case report describes a rare NTRK3-rearranged spindle cell neoplasm in the groin of a 29-year-old female and provides further clinical and morphological features of this entity.


Asunto(s)
Ingle , Receptor trkC , Neoplasias de los Tejidos Blandos , Humanos , Femenino , Receptor trkC/genética , Adulto , Neoplasias de los Tejidos Blandos/patología , Neoplasias de los Tejidos Blandos/genética , Neoplasias de los Tejidos Blandos/diagnóstico , Ingle/patología , Diagnóstico Diferencial , Reordenamiento Génico , Sarcoma/genética , Sarcoma/patología , Sarcoma/diagnóstico
2.
Artículo en Inglés | MEDLINE | ID: mdl-27366327

RESUMEN

X-ray mammography, the current gold standard for breast cancer detection, has a 20% false-negative rate (cancer is undetected) and increases in younger women with denser breast tissue. Diffuse optical imaging (DOI) is a safe (nonionizing), and relatively inexpensive method for noninvasive imaging of breast cancer in human subjects (including dense breast tissues) by providing physiological information (e.g. oxy- and deoxy- hemoglobin concentration). At the Optical Imaging Laboratory, a hand-held optical imager has been developed which employs a breast contourable probe head to perform simultaneous illumination and detection of large surfaces towards near real-time imaging of human breast cancer. Gen-1 and gen-2 versions of the handheld optical imager have been developed and previously demonstrated imaging in tissue phantoms and healthy human subjects. Herein, the hand-held optical imagers are applied towards in vivo imaging of breast cancer subjects in an attempt to determine the ability of the imager to detect breast tumors. Five female human subjects (ages 51-74) diagnosed with breast cancer were imaged with the gen-1 optical imager prior to surgical intervention. One of the subjects was also imaged with the gen-2 optical imager. Both imagers use 785 nm laser diode sources and ICCD camera detectors to generate 2D surfaces maps of total hemoglobin absorption. The subjects lay in supine position and images were collected at various locations on both the ipsilateral (tumor-containing) and contralateral (non-tumor containing) breasts. The optical images (2D surface maps of optical absorption due to total hemoglobin concentration) show regions of higher intensity at the tumor location, which is indicative of increased vasculature and higher blood content due to the presence of the tumor. Additionally, a preliminary result indicates the potential to image lymphatic spread. This study demonstrates the potential of the hand-held optical devices to noninvasively image breast cancer in human subjects.

3.
Appl Opt ; 52(33): 8060-6, 2013 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-24513758

RESUMEN

A generation-2 (Gen-2) handheld optical imager capable of two-dimensional surface and three-dimensional tomographic imaging has recently been developed. Herein, the ability of the handheld imager to detect and resolve two targets under diffuse and fluorescence imaging conditions has been demonstrated via tissue phantom studies. Two-dimensional surface imaging studies demonstrated that two 0.96 cm diameter Indocyannine Green targets were detected and resolved ~0.5 cm apart (between edges) at a target depth of 1 cm during diffuse imaging and up to 2 cm depth during fluorescence imaging. Preliminary 3D tomographic imaging capability to resolve the two targets was also demonstrated, but requires extensive future studies.


Asunto(s)
Tecnología de Fibra Óptica/instrumentación , Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Microscopía Fluorescente/instrumentación , Sistemas de Atención de Punto , Tomografía Óptica/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Miniaturización
4.
J Biomed Opt ; 17(8): 081402-1, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23224163

RESUMEN

Hand-held optical imagers are developed by various researchers towards reflectance-based spectroscopic imaging of breast cancer. Recently, a Gen-1 handheld optical imager was developed with capabilities to perform two-dimensional (2-D) spectroscopic as well as three-dimensional (3-D) tomographic imaging studies. However, the imager was bulky with poor surface contact (~30%) along curved tissues, and limited sensitivity to detect targets consistently. Herein, a Gen-2 hand-held optical imager that overcame the above limitations of the Gen-1 imager has been developed and the instrumentation described. The Gen-2 hand-held imager is less bulky, portable, and has improved surface contact (~86%) on curved tissues. Additionally, the forked probe head design is capable of simultaneous bilateral reflectance imaging of both breast tissues, and also transillumination imaging of a single breast tissue. Experimental studies were performed on tissue phantoms to demonstrate the improved sensitivity in detecting targets using the Gen-2 imager. The improved instrumentation of the Gen-2 imager allowed detection of targets independent of their location with respect to the illumination points, unlike in Gen-1 imager. The developed imager has potential for future clinical breast imaging with enhanced sensitivity, via both reflectance and transillumination imaging.


Asunto(s)
Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Imagenología Tridimensional/instrumentación , Reconocimiento de Normas Patrones Automatizadas/métodos , Tomografía Óptica/instrumentación , Transductores , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Miniaturización , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Sensors (Basel) ; 12(2): 1885-97, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22438743

RESUMEN

Hand-held near-infrared (NIR) optical imagers are developed by various researchers towards non-invasive clinical breast imaging. Unlike these existing imagers that can perform only reflectance imaging, a generation-2 (Gen-2) hand-held optical imager has been recently developed to perform both reflectance and transillumination imaging. The unique forked design of the hand-held probe head(s) allows for reflectance imaging (as in ultrasound) and transillumination or compressed imaging (as in X-ray mammography). Phantom studies were performed to demonstrate two-dimensional (2D) target detection via reflectance and transillumination imaging at various target depths (1-5 cm deep) and using simultaneous multiple point illumination approach. It was observed that 0.45 cc targets were detected up to 5 cm deep during transillumination, but limited to 2.5 cm deep during reflectance imaging. Additionally, implementing appropriate data post-processing techniques along with a polynomial fitting approach, to plot 2D surface contours of the detected signal, yields distinct target detectability and localization. The ability of the gen-2 imager to perform both reflectance and transillumination imaging allows its direct comparison to ultrasound and X-ray mammography results, respectively, in future clinical breast imaging studies.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Iluminación/instrumentación , Mamografía/instrumentación , Fotometría/instrumentación , Transductores , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Rayos Infrarrojos , Miniaturización , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA