1.
Health Phys ; 93(6): 631-5, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17993843

RESUMEN

A comparative study of electron paramagnetic resonance dosimetry in Q- and X-bands has shown that Q-band is able to provide accurate measurements of radiation doses even below 0.5 Gy with tooth enamel samples as small as 2 mg. The optimal amount of tooth enamel for dose measurements in Q-band was found to be 4 mg. This is less than 1% of the total amount of tooth enamel in one molar tooth. Such a small amount of tooth enamel can be harmlessly obtained in an emergency requiring after-the-fact radiation dose measurement. The other important advantage of Q-band is full resolution of the radiation-induced EPR signal from the native, background signal. This separation makes dose response measurements much easier in comparison to conventional X-band measurements in which these overlapping signals necessitate special methods for doses below 0.5 Gy. The main disadvantages of Q-band measurements are a higher level of noise and lower spectral reproducibility than in X-band. The effect of these negative factors on the precision of dose measurements in Q-band could probably be reduced by improvement of sample fixation in the resonance cavity and better optimization of signal filtration to reduce high-frequency noise.


Asunto(s)
Esmalte Dental , Diente Molar , Radiometría/métodos , Espectroscopía de Resonancia por Spin del Electrón , Estudios de Factibilidad , Humanos , Dosis de Radiación
2.
Radiat Prot Dosimetry ; 120(1-4): 176-83, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16702247

RESUMEN

The objective of the Third International Intercomparison on EPR Tooth Dosimetry was to evaluate laboratories performing tooth enamel dosimetry <300 mGy. Final analysis of results included a correlation analysis between features of laboratory dose reconstruction protocols and dosimetry performance. Applicability of electron paramagnetic resonance (EPR) tooth dosimetry at low dose was shown at two applied dose levels of 79 and 176 mGy. Most (9 of 12) laboratories reported the dose to be within 50 mGy of the delivered dose of 79 mGy, and 10 of 12 laboratories reported the dose to be within 100 mGy of the delivered dose of 176 mGy. At the high-dose tested (704 mGy) agreement within 25% of the delivered dose was found in 10 laboratories. Features of EPR dose reconstruction protocols that affect dosimetry performance were found to be magnetic field modulation amplitude in EPR spectrum recording, EPR signal model in spectrum deconvolution and duration of latency period for tooth enamel samples after preparation.


Asunto(s)
Espectroscopía de Resonancia por Spin del Electrón/métodos , Odontología Forense/métodos , Radioisótopos/análisis , Radiometría/métodos , Diente/química , Espectroscopía de Resonancia por Spin del Electrón/tendencias , Odontología Forense/tendencias , Humanos , Radiometría/tendencias , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Appl Radiat Isot ; 62(2): 163-71, 2005 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15607443

RESUMEN

The objective of the 3rd International Intercomparison on Electron Paramagnetic Resonance (EPR) Tooth Dosimetry was the evaluation of laboratories performing tooth enamel dosimetry below 300 mGy. Participants had to reconstruct the absorbed dose in tooth enamel from 11 molars, which were cut into two halves. One half of each tooth was irradiated in a 60Co beam to doses in the ranges of 30-100 mGy (5 samples), 100-300 mGy (5 samples), and 300-900 mGy (1 sample). Fourteen international laboratories participated in this intercomparison programme. A first analysis of the results and an overview of the essential features of methods applied in different laboratories are presented. The relative standard deviation of results of all methods was better than 27% for applied doses in the range of 79-704 mGy. In the analysis of the unirradiated tooth halves 8% of the samples were identified as outliers with additional absorbed dose above background dose.


Asunto(s)
Espectroscopía de Resonancia por Spin del Electrón/métodos , Espectroscopía de Resonancia por Spin del Electrón/normas , Radiometría/métodos , Radiometría/normas , Estándares de Referencia , Diente/química , Diente/efectos de la radiación , Benchmarking/métodos , Carga Corporal (Radioterapia) , Humanos , Técnicas In Vitro , Internacionalidad , Garantía de la Calidad de Atención de Salud/métodos , Garantía de la Calidad de Atención de Salud/normas , Dosis de Radiación , Efectividad Biológica Relativa , Reproducibilidad de los Resultados , Estudios Retrospectivos , Medición de Riesgo/métodos , Medición de Riesgo/normas , Sensibilidad y Especificidad