Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Clin Radiol ; 71(8): 722-8, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27207375

RESUMEN

Computed tomography coronary angiography is increasingly used in imaging departments in the investigation of patients with chest pain and suspected coronary artery disease. Due to the routine use of heart rate controlling medication and the potential for very high radiation doses during these scans, there is a need for guidance on best practice for departments performing this examination, so the patient can be assured of a good quality scan and outcome in a safe environment. This article is a summary of the document on 'Standards of practice of computed tomography coronary angiography (CTCA) in adult patients' published by the Royal College of Radiologists (RCR) in December 2014.


Asunto(s)
Angiografía por Tomografía Computarizada/normas , Angiografía Coronaria/normas , Seguridad del Paciente/normas , Guías de Práctica Clínica como Asunto , Protección Radiológica/normas , Radiología/normas , Cardiología/normas , Humanos , Exposición a la Radiación/prevención & control , Exposición a la Radiación/normas , Reino Unido
3.
Clin Radiol ; 71(2): 151-8, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26703115

RESUMEN

AIM: To assess the diagnostic accuracy of computed tomography coronary angiography (CTCA) using a combination of high-definition CT (HD-CTCA) and high level of reader experience, with invasive coronary angiography (ICA) as the reference standard, in high-risk patients for the investigation of coronary artery disease (CAD). MATERIALS AND METHODS: Three hundred high-risk patients underwent HD-CTCA and ICA. Independent experts evaluated the images for the presence of significant CAD, defined primarily as the presence of moderate (≥ 50%) stenosis and secondarily as the presence of severe (≥ 70%) stenosis in at least one coronary segment, in a blinded fashion. HD-CTCA was compared to ICA as the reference standard. RESULTS: No patients were excluded. Two hundred and six patients (69%) had moderate and 178 (59%) had severe stenosis in at least one vessel at ICA. The sensitivity, specificity, positive predictive value, and negative predictive value were 97.1%, 97.9%, 99% and 93.9% for moderate stenosis, and 98.9%, 93.4%, 95.7% and 98.3%, for severe stenosis, on a per-patient basis. CONCLUSION: The combination of HD-CTCA and experienced readers applied to a high-risk population, results in high diagnostic accuracy comparable to ICA. Modern generation CT systems in experienced hands might be considered for an expanded role.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Riesgo , Sensibilidad y Especificidad
4.
Clin Radiol ; 69(7): 739-44, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24824980

RESUMEN

AIM: To evaluate the usage, safety, and efficacy of high-dose intravenous metoprolol for heart rate reduction in computer tomographic (CT) coronary angiography. MATERIALS AND METHODS: As this was retrospective analysis of anonymous data, medical ethics committee approval was waived by the regional health research authority. Patients, who had known iodinated contrast medium allergy, contraindications to ß-blockers, atrial fibrillation, and indications other than suspected coronary artery disease, were excluded from analysis. The ultimate study population of 662 were analysed with details of intravenous metoprolol doses, complications, heart rate before administration of intravenous metoprolol (resting heart rate, RHR), heart rate at acquisition of scan (acquisition heart rate, AHR), and usage of low radiation dose protocols. RESULTS: Of the ultimate study population of 662 patients, 183 had no intravenous metoprolol with mean acquisition heart rate (AHR) of 58 beats per minute (bpm), 257 had 1-15 mg intravenous metoprolol with mean AHR of 57 bpm, 114 had 16-29 mg intravenous metoprolol with mean AHR of 62 bpm and 108 had ≥30 mg intravenous metoprolol with mean AHR of 66 bpm. In the group receiving intravenous metoprolol, average usage was 19 mg (maximum 67 mg) with average reduction in HR of 15 bpm. There were no clinical incidents in relation to the use of high-dose intravenous metoprolol. CONCLUSION: Higher doses of intravenous metoprolol are beneficial in achieving target heart rates to facilitate usage of low radiation dose protocols. With appropriate exclusion criteria, higher doses of intravenous metoprolol, well in excess of 15 mg, can be safely administered when carefully titrated.


Asunto(s)
Antagonistas de Receptores Adrenérgicos beta 1/administración & dosificación , Angiografía Coronaria/métodos , Frecuencia Cardíaca/efectos de los fármacos , Metoprolol/administración & dosificación , Adulto , Anciano , Análisis de Varianza , Humanos , Infusiones Intravenosas , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada Espiral
6.
Clin Radiol ; 68(5): e254-65, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23465325

RESUMEN

There have been numerous advances in the field of cardiac imaging. The advent of multidetector computed tomography coronary angiography (MDCT-CA) and in particular electrocardiographic (ECG)-gated acquisition has revolutionized the investigation of the complete spectrum of complications of common cardiothoracic surgical procedures. Generic complications, such as mediastinitis, pericardial effusion, sternal osteomyelitis, and mediastinal fibrosis, are discussed with illustrative examples of multiplanar and volume-rendered three-dimensional reconstructions. Graft-related complications of both coronary artery bypass grafts and aortic root grafts are reviewed. The role of MDCT-CA in the investigation of prosthetic valve endocarditis and root abscesses is outlined. We present a complete illustration of the detailed images that are obtained when investigating a full range of graft-related complications from both aortic and coronary surgery using ECG-gated MDCT-CA. MDCT-CA has the potential to become established as the optimal technique with which to image a multitude of complications post-cardiac surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Angiografía Coronaria/métodos , Cardiopatías/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Complicaciones Posoperatorias/diagnóstico por imagen , Medios de Contraste , Puente de Arteria Coronaria , Electrocardiografía/métodos , Cardiopatías/etiología , Prótesis Valvulares Cardíacas , Humanos , Complicaciones Posoperatorias/etiología , Intensificación de Imagen Radiográfica/métodos
7.
Br J Radiol ; 85(1015): 965-71, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22167511

RESUMEN

OBJECTIVES: Radiofrequency ablation of the pulmonary veins is an accepted treatment for atrial fibrillation. An accurate knowledge of pulmonary venous anatomy and dimensions is desirable prior to such a procedure. The objective of this study was to use 64-detector row cardiac CT to investigate the changes in pulmonary venous dimensions during the cardiac cycle. METHODS: Data from 44 consecutive patients with no significant cardiovascular pathology who underwent electrocardiogram (ECG)-gated 64-detector row coronary angiography were retrospectively analysed. Average diameter and cross-sectional area were measured at 5 mm intervals from each pulmonary vein ostium, in ventricular end-diastole and ventricular end-systole, using curved multiplanar reformats. RESULTS: 4 (9.1%) patients had pulmonary vein anomalies and were excluded. In the remaining 40 patients, pulmonary vein diameter and area at the ostium were significantly larger in end-systole in all four veins, with the largest differences in the superior pulmonary veins. Dimensional changes for diameter (millimetres) and area (square millimetres) were as follows: left superior pulmonary vein, 2.5 (p<0.001), 65.48 (p<0.001); right superior pulmonary vein, 1.63 (p<0.001), 56.27 (p<0.001); left inferior pulmonary vein, 1.1 (p<0.001), 30.41 (p<0.001); and right inferior pulmonary vein, 0.68 (p=0.005), 30.14 (p=0.005). Less marked changes were seen at measurement sites further from the atrium. Interobserver correlation was high (all but one measurement >0.9). CONCLUSION: Pulmonary vein dimensions change significantly between end-systole and end-diastole, and the ostia of the superior pulmonary veins are potentially the most vulnerable to dimensional inaccuracies. ECG-gated cardiac CT may provide a more precise method of pulmonary venous dimensional measurement than non-gated techniques. Knowledge of change in pulmonary vein diameter offers interesting potential research into the effect of pulmonary vein function.


Asunto(s)
Fibrilación Atrial/cirugía , Técnicas de Imagen Sincronizada Cardíacas/métodos , Angiografía Coronaria/métodos , Venas Pulmonares/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X/métodos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Ablación por Catéter/métodos , Estudios de Cohortes , Femenino , Humanos , Imagenología Tridimensional , Masculino , Variaciones Dependientes del Observador , Cuidados Preoperatorios/métodos , Venas Pulmonares/anomalías , Venas Pulmonares/cirugía , Estudios Retrospectivos , Sensibilidad y Especificidad , Estadísticas no Paramétricas
8.
Clin Radiol ; 65(12): 1021-30, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21070908

RESUMEN

Illicit drug abuse is a continuing menace of epidemic proportions associated with serious medical and social problems. Drug abuse can have a wide variety of presentations some of which can be life-threatening. The clinical diagnosis can be challenging as the history is usually limited or absent. Radiologists need to be familiar with varied imaging presentations and the related complications of illicit drug abuse to ensure correct diagnosis and appropriate timely treatment. This review will illustrate the imaging spectrum of illicit drug abuse involving several organ systems and also discuss the pathophysiological consequences of drug abuse.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Trastornos Cerebrovasculares/diagnóstico , Enfermedades Pulmonares/diagnóstico , Enfermedades Musculoesqueléticas/diagnóstico , Trastornos Relacionados con Sustancias/diagnóstico , Adolescente , Adulto , Enfermedades Cardiovasculares/inducido químicamente , Trastornos Cerebrovasculares/inducido químicamente , Diagnóstico por Imagen/métodos , Femenino , Humanos , Enfermedades Pulmonares/inducido químicamente , Masculino , Trastornos Relacionados con Sustancias/complicaciones
9.
Clin Radiol ; 65(11): 859-67, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20933639

RESUMEN

Ionizing radiation has long been known to increase the risk of cancer. X-rays and γ-rays are officially classified as a carcinogen by the World Health Organization's International Agency for Research on Cancer.(1) Of the 5 billion imaging investigations performed worldwide two-thirds employ ionizing radiation.(2) Diagnostic x-rays are the largest man-made source of radiation exposure to the general population, and computed tomography (CT) represents the largest proportion of these.(3) Diagnostic CT has seen a dramatic increase in applications in the last two decades, not least in the higher dose applications. Whilst the increased use of CT has undoubtedly been of patient benefit, it inevitably will be associated with an increase in malignancy due to medical exposure. In fact a recent study from the USA has estimated that the CT examinations performed in 2007 could result in 29,000 future cancers based on current risk estimations.(4) Whilst the numbers in the UK will be less (only 4 million examinations are performed compared to 70 million), it is clear that it is the responsibility of all radiologists to carefully examine their CT techniques and protocols with the aim to reduce the dose of examinations without compromising their accuracy. Cardiac computed tomographic angiography (CTA) initially was a very high dose application. However, both clinicians and CT system manufacturers have done a large amount of work to reduce dose. Dramatic changes have been achieved and the aim of this review is to highlight these. However, such developments are not exclusively applicable to cardiac CTA and many can be utilized in CT in general.


Asunto(s)
Angiografía Coronaria/efectos adversos , Neoplasias Inducidas por Radiación/prevención & control , Tomografía Computarizada por Rayos X/efectos adversos , Angiografía Coronaria/tendencias , Relación Dosis-Respuesta en la Radiación , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/tendencias
10.
Br J Radiol ; 83(987): 194-205, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20197434

RESUMEN

Multidetector row computed tomography (MDCT) with its high spatial and temporal resolution has now become an established and complementary method for cardiac imaging. It can now be used reliably to exclude significant coronary artery disease and delineate complex coronary artery anomalies, and has become a valuable problem-solving tool. Our experience with MDCT imaging suggests that it is clinically useful for imaging the pericardium. It is important to be aware of the normal anatomy of the pericardium and not mistake normal variations for pathology. The pericardial recesses are visible in up to 44% of non-electrocardiogram (ECG)-gated MDCT images. Abnormalities of the pericardium can now be identified with increasing certainty on 64-detector row CT; they may be the key to diagnosis and therefore must not be overlooked. This educational review of the pericardium will cover different imaging techniques, with a significant emphasis on MDCT. We have a large research and clinical experience of ECG-gated cardiac CT and will demonstrate examples of pericardial recesses, their variations and a wide variety of pericardial abnormalities and systemic conditions affecting the pericardium. We give a brief relevant background of the conditions and reinforce the key imaging features. We aim to provide a pictorial demonstration of the wide variety of abnormalities of the pericardium and the pitfalls in the diagnosis of pericardial disease.


Asunto(s)
Cardiopatías/diagnóstico por imagen , Pericardio/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Electrocardiografía , Neoplasias Cardíacas/diagnóstico por imagen , Hematoma/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Quiste Mediastínico/diagnóstico por imagen , Derrame Pericárdico/diagnóstico por imagen , Pericarditis/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador
11.
Br J Radiol ; 83(988): 327-30, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19723770

RESUMEN

The aim of this study was to determine the prognostic value of coronary multidetector CT angiography (MDCTA) in patients with an intermediate pre-test probability of significant coronary artery disease (CAD). Patients who underwent 64-slice coronary MDCTA and met the selection criteria were identified and assessed for intermediate pre-test probability. Coronary MDCTA scans were preceded by calcium scoring, whereas all MDCTA scans were interrogated for the presence of plaque composition and the distribution and degree of stenosis. Significant stenosis was classified as being >50% of the luminal diameter. All patients were followed up for the occurrence of (i) cardiac death, (ii) non-fatal myocardial infarction, (iii) unstable angina requiring hospital admission and (iv) revascularisation. 138 patients were included (follow-up of 19.9 months); of these, 8 had a cardiac event (all revascularisations) and all had a positive coronary MDCTA. Patients with normal coronary arteries or non-significant stenosis suffered no cardiac events during follow-up. There were significant differences between the two groups regarding the presence of significant stenosis (p<0.001), the presence of plaque (p = 0.011) and a calcium score >10 (p = 0.003); 36.4% of patients with significant stenosis underwent revascularisation. In conclusion, this is the first UK study to investigate survival data in a population of intermediate-risk patients with no prior history of CAD who were investigated with coronary MDCTA. Coronary MDCTA can confidently rule out significant CAD in the intermediate-risk population and guide risk factor modification in patients with demonstrated coronary atheroma.


Asunto(s)
Enfermedad Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Angiografía Coronaria/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Reino Unido , Adulto Joven
12.
Clin Radiol ; 64(6): 601-7, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19414082

RESUMEN

AIM: To assess the accuracy of clinical coronary computed tomography angiography (CTA) data compared to invasive coronary angiography, and to determine the prognostic value of a negative coronary CTA examination in symptomatic, intermediate-risk patients. METHODS: Thirty-seven months of coronary CTA data were audited. Seventy-eight patients were identified who had undergone coronary CTA followed by invasive coronary angiography (ICA) to determine the accuracy of CTA versus ICA. One hundred and seventy-eight patients were identified who had a "negative" coronary CTA to enable evaluation of the prognostic value of a negative CTA examination. RESULTS: Of the 78 patients in the accuracy analysis group there were 43 true-negative, two false-negative, 26 true-positive, and seven false-positive results producing a sensitivity of 92.9%, specificity of 86%, negative predictive value of 95.6%, and positive predictive value of 78.8%. The 178 patients who had a negative coronary CTA examination were followed up for a mean of 366 days and were all alive (0% mortality) with no episodes of myocardial infarction or unstable angina; two patients underwent elective revascularization procedures (1.1%). CONCLUSION: According to medium-term analysis, the accuracy of the clinical coronary CTA programme is in line with published trial data, producing excellent sensitivity and negative predictive values. The finding of a negative coronary CTA in symptomatic, intermediate-risk patients appears to confer a good prognosis, at mean follow-up of 1 year, with no deaths or episodes of myocardial infarction or unstable angina. This suggests that the prognostic value of a negative coronary CTA may be similar to that conferred by negative myocardial perfusion scintigraphy or stress echocardiography.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Auditoría Médica , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Medición de Riesgo , Sensibilidad y Especificidad
14.
Br J Radiol ; 81(964): 275-90, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18344273

RESUMEN

Multi-detector row cardiac CT imaging demonstrates clinical usefulness in valvular heart disease, for which CT has not been traditionally used. Electrocardiographic (ECG)-gated CT coronary angiography also has an established clinical role with an increasingly solid evidence base, and the same data set in these patients also provides valuable information about chamber and valvular structure and function; this information should also be considered when interpreting cardiac CT and non-ECG gated thoracic imaging. Although true flow data cannot be achieved using CT, as with echocardiography and MRI, there are a number of imaging features that may be used when interpreting and inferring valve pathology. This article discusses the role of currently available imaging modalities and the rationale for cardiac CT, while focusing on the CT interpretation of valvular heart disease with respect to the relevant pathophysiology and management options that have importance to the radiologist. A suggested method of post-processing image review is provided with reference to a variety of normal and pathological pictorial illustrations.


Asunto(s)
Electrocardiografía/métodos , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Ecocardiografía , Enfermedades de las Válvulas Cardíacas/fisiopatología , Prótesis Valvulares Cardíacas , Humanos , Imagen por Resonancia Magnética , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología
15.
Clin Radiol ; 63(4): 415-23, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18325362

RESUMEN

AIM: To determine whether there is a relationship between left ventricular (LV) haemodynamic parameters, circulation times, and arterial contrast opacification that might affect the image quality of computed tomography (CT) coronary angiography. METHODS: Thirty-six patients were included in the study: 18 with cardiomyopathy (CM) and LV dilatation of suspected ischaemic aetiology [age 57.9+/-13.7 years, range 30-77 years; 14 male, four female; body mass index (BMI)=27.7+/-4.5, range 25.5-31.8] and 18 controls (age 62.3+/-9.4 years, range 47-89 years; 10 male, eight female; BMI 27.8+/-6.6; range 19.2-33.6). Coronary artery image quality was assessed using a three-point visual scale; contrast medium circulation times, aortic root contrast attenuation, and LV functional parameters were studied. RESULTS: Visually reduced contrast opacification impaired image quality more often in the CM group than the control group (27.4 versus 5.1%). A total of 55.6% CM patients had a contrast transit time ranging from 30-75 s; the number of "unassessable" segments increased with increasing transit time conforming to a fitted quadratic model (R2=0.74). The relationship between LV ejection fraction and contrast attenuation may also conform to a quadratic model (R2=0.71). CONCLUSION: LV haemodynamics influence coronary artery opacification using cardiac CT, and users imaging this subgroup must do so with the knowledge of this potential pitfall. The results indicate the need for further studies examining CT protocols in this clinical subgroup.


Asunto(s)
Cardiomiopatía Dilatada/diagnóstico por imagen , Angiografía Coronaria/métodos , Circulación Coronaria , Tomografía Computarizada por Rayos X/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Intensificación de Imagen Radiográfica , Interpretación de Imagen Radiográfica Asistida por Computador
16.
Clin Radiol ; 63(4): 464-74, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18325368

RESUMEN

Multi-detector row cardiac computed tomography (MDCT) with its high spatial and temporal resolution now has an established clinical role in cardiac imaging. The present review illustrates the MDCT appearances of cardiomyopathy, with reference to the normal myocardium, using multi-planar, near-isotropic imaging, three-dimensional volume rendering, and ECG-gated multi-phasic functional imaging software capabilities of 64-MDCT. MRI and echocardiographic correlations are also provided where appropriate.


Asunto(s)
Cardiomiopatías/diagnóstico , Miocardio , Tomografía Computarizada por Rayos X/métodos , Cardiomiopatías/diagnóstico por imagen , Electrocardiografía , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética
17.
Clin Radiol ; 62(7): 632-8, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17556031

RESUMEN

AIMS: To evaluate the diagnostic accuracy of computed tomography (CT) in assessing haemodynamically significant coronary artery stenoses in patients with cardiomyopathy (CM). SUBJECTS AND METHODS: Eighteen patients with CM were approached to undergo CT coronary angiography to evaluate the use of this technique for investigating the presence of significant coronary artery disease (CAD), and also to compare the findings with catheter angiography. RESULTS: On a segment-by-segment analysis the sensitivity, specificity, positive and negative predictive values in the CM group were 66.7, 96.5, 40 and 98.8%, respectively, with 100% accuracy in "whole-patient terms". CONCLUSION: Non-invasive, 16-detector row CT coronary angiography in patients with presumed CM would seem to be a useful clinical tool for the exclusion of significant coronary artery disease. However, the presence of suboptimal contrast opacification in this patient group means that the implication of these results must be interpreted with caution.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Angiografía Coronaria/métodos , Enfermedad Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Enfermedad Coronaria/etiología , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
19.
Br J Radiol ; 79(946): e133-6, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16980669

RESUMEN

We present the case of an adult female patient with a giant coronary artery aneurysm secondary to Kawasaki disease diagnosed for the first time, as far as the authors are aware, on multi-detector row computed tomography (MDCT). The long-term complications relate to the persistence of these aneurysms with giant coronary aneurysms having the lowest regression rate, the highest risk of stenosis and strongest association with myocardial infarction. MDCT coronary angiography represents an ideal, alternative non-invasive imaging modality for the diagnosis and follow-up of the coronary arterial complications of Kawasaki disease, thereby avoiding invasive coronary imaging, and its use in the management algorithm should be considered. We also aim to contribute to the expanding clinical role of MDCT coronary imaging.


Asunto(s)
Aneurisma Coronario/diagnóstico por imagen , Síndrome Mucocutáneo Linfonodular/complicaciones , Adulto , Aneurisma Coronario/etiología , Angiografía Coronaria/métodos , Femenino , Humanos , Tomografía Computarizada por Rayos X
20.
Clin Radiol ; 61(9): 749-57, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16905381

RESUMEN

AIM: To evaluate the diagnostic accuracy of 16-detector row computed tomography (CT) in assessing haemodynamically significant coronary artery stenoses in patients under evaluation for aortic stenosis pre-aortic valve replacement. SUBJECTS AND METHODS: Forty consecutive patients under evaluation for severe aortic stenosis and listed for cardiac catheterization before potential aortic valve replacement underwent coronary artery calcium (CAC) scoring and retrospective electrocardiogram (ECG)-gated multi-detector row computed tomographic coronary angiography (MDCTA) using a GE Lightspeed 16-detector row CT within 1 month of invasive coronary angiography (ICA) for comparative purposes. All 13 major coronary artery segments of the American Heart Association model were evaluated for the presence of > or =50% stenosis and compared to the reference standard. Data were analysed on a segment-by-segment basis and also in "whole patient" terms. RESULTS: A total of 412/450 segments from 35 patients were suitable for analysis. The overall accuracy of MDCTA for detection of segments with > or =50% stenosis was high, with a sensitivity of 81.3%, specificity 95.0%, positive predictive value (PPV) 57.8%, and negative predictive value (NPV) 98.4%. On a "whole-patient" basis, 100% (19/19) of patients with significant coronary disease were correctly identified and there were no false-negatives. Excluding patients with CAC >1000 from the analysis improved the accuracy of MDCTA to: sensitivity 90%, specificity 98.1%, PPV 60%, NPV 99.7%. CONCLUSION: Non-invasive 16-detector row MDCTA accurately excludes significant coronary disease in patients with severe aortic stenosis undergoing evaluation before aortic valve replacement and in whom ICA can therefore be avoided. Its segment-by-segment accuracy is improved further if CAC>1000 is used as a gatekeeper to MDCTA.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Angiografía Coronaria/normas , Tomografía Computarizada por Rayos X/normas , Adulto , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA