Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Circulation ; 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38940005

RESUMEN

BACKGROUND: Current estimates of atrial fibrillation (AF)-associated mortality rely on claims- or clinical-derived diagnoses of AF, limit AF to a binary entity, or are confounded by comorbidities. The objective of the present study is to assess the association between device-recognized AF and mortality among patients with cardiac implantable electronic devices capable of sensitive and continuous atrial arrhythmia detection. Secondary outcomes include relative mortality among cohorts with no AF, paroxysmal AF, persistent AF, and permanent AF. METHODS: Using the deidentified Optum Clinformatics US claims database (2015 to 2020) linked to the Medtronic CareLink database, we identified individuals with a cardiac implantable electronic device who transmitted data ≥6 months after implantation. AF burden was assessed during the first 6 months after implantation (baseline period). Subsequent mortality, assessed from claims data, was compared between patients with and those without AF, with adjustment for age, geographic region, insurance type, Charlson Comorbidity Index, and implantation year. RESULTS: Of 21 391 patients (age, 72.9±10.9 years; 56.3% male) analyzed, 7798 (36.5%) had device-recognized AF. During a mean of 22.4±12.9 months (median, 20.1 [12.8-29.7] months) of follow-up, the overall incidence of mortality was 13.5%. Patients with AF had higher adjusted all-cause mortality than patients without AF (hazard ratio, 1.29 [95% CI, 1.20-1.39]; P<0.001). Among those with AF, patients with nonparoxysmal AF had the greatest risk of mortality (persistent AF versus paroxysmal AF: hazard ratio, 1.36 [95% CI, 1.18-1.58]; P<.001; permanent AF versus paroxysmal AF: hazard ratio, 1.23 [95% CI, 1.14-1.34]; P<.001). CONCLUSIONS: After adjustment for potential confounding factors, presence of AF was associated with higher mortality than no AF in our cohort of patients with cardiac implantable electronic devices. Among those with AF, nonparoxysmal AF was associated with the greatest risk of mortality.

2.
JACC Clin Electrophysiol ; 10(4): 718-730, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38430088

RESUMEN

BACKGROUND: Integrating patient-specific cardiac implantable electronic device (CIED)-detected atrial fibrillation (AF) burden with measures of health care cost and utilization allows for an accurate assessment of the AF-related impact on health care use. OBJECTIVES: The goal of this study was to assess the incremental cost of device-recognized AF vs no AF; compare relative costs of paroxysmal atrial fibrillation (pAF), persistent atrial fibrillation (PeAF), and permanent atrial fibrillation (PermAF) AF; and evaluate rates and sources of health care utilization between cohorts. METHODS: Using the de-identified Optum Clinformatics U.S. claims database (2015-2020) linked with the Medtronic CareLink database, CIED patients were identified who transmitted data ≥6 months postimplantation. Annualized per-patient costs in follow-up were analyzed from insurance claims and adjusted to 2020 U.S. dollars. Costs and rates of health care utilization were compared between patients with no AF and those with device-recognized pAF, PeAF, and PermAF. Analyses were adjusted for geographical region, insurance type, CHA2DS2-VASc score, and implantation year. RESULTS: Of 21,391 patients (mean age 72.9 ± 10.9 years; 56.3% male) analyzed, 7,798 (36.5%) had device-recognized AF. The incremental annualized increased cost in those with AF was $12,789 ± $161,749 per patient, driven by increased rates of health care encounters, adverse clinical events associated with AF, and AF-specific interventions. Among those with AF, PeAF was associated with the highest cost, driven by increased rates of inpatient and outpatient hospitalization encounters, heart failure hospitalizations, and AF-specific interventions. CONCLUSIONS: Presence of device-recognized AF was associated with increased health care cost. Among those with AF, patients with PeAF had the highest health care costs. Mechanisms for cost differentials include both disease-specific consequences and physician-directed interventions.


Asunto(s)
Fibrilación Atrial , Costos de la Atención en Salud , Aceptación de la Atención de Salud , Humanos , Fibrilación Atrial/economía , Fibrilación Atrial/terapia , Masculino , Costos de la Atención en Salud/estadística & datos numéricos , Femenino , Anciano , Persona de Mediana Edad , Aceptación de la Atención de Salud/estadística & datos numéricos , Estados Unidos , Desfibriladores Implantables/economía , Desfibriladores Implantables/estadística & datos numéricos , Hospitalización/economía , Hospitalización/estadística & datos numéricos , Costo de Enfermedad , Anciano de 80 o más Años
3.
J Cardiovasc Electrophysiol ; 35(2): 341-345, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38164063

RESUMEN

INTRODUCTION: The increasing use of insertable cardiac monitors (ICMs) for long-term continuous arrhythmia monitoring creates a high volume of transmissions and a significant workload for clinics. The ability to remotely reprogram device alert settings without in-office patient visits was recently introduced, but its impact on clinic workflow compared to the previous ICM iteration is unknown. METHODS: The aim of this real-world study was to evaluate the impact of device reprogramming capabilities on ICM alert burden and on clinic workflow. Deidentified data was obtained from US patients and a total of 19 525 receiving a LINQ II were propensity score-matched with 19 525 implanted with LINQ TruRhythm (TR) ICM based on age and reason for monitoring. RESULTS: After reprogramming, ICM alerts reduced by 20.5% (p < .001). Compared with patients monitored with LINQ TR, patients with LINQ II had their device reprogrammed sooner after implant and more frequently during follow-up. Adoption of remote programming was projected to lead to an annual total clinic time savings of 211 h per 100 ICM patients managed. CONCLUSION: These data suggest that utilization of ICM alert reprogramming has increased with remote capabilities, which may reduce clinic and patient burden for ICM follow-up and free clinician time for other valuable patient care activities.


Asunto(s)
Arritmias Cardíacas , Electrocardiografía Ambulatoria , Humanos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Trastorno del Sistema de Conducción Cardíaco
4.
BMC Cardiovasc Disord ; 23(1): 45, 2023 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-36698055

RESUMEN

BACKGROUND: Insertable cardiac monitors (ICMs) are a clinically effective means of detecting atrial fibrillation (AF) in high-risk patients, and guiding the initiation of non-vitamin K oral anticoagulants (NOACs). Their cost-effectiveness from a US clinical payer perspective is not yet known. The objective of this study was to evaluate the cost-effectiveness of ICMs compared to standard of care (SoC) for detecting AF in patients at high risk of stroke (CHADS2 ≥ 2), in the US. METHODS: Using patient data from the REVEAL AF trial (n = 393, average CHADS2 score = 2.9), a Markov model estimated the lifetime costs and benefits of detecting AF with an ICM or with SoC (specifically intermittent use of electrocardiograms and 24-h Holter monitors). Ischemic and hemorrhagic strokes, intra- and extra-cranial hemorrhages, and minor bleeds were modelled. Diagnostic and device costs, costs of treating stroke and bleeding events and medical therapy-specifically costs of NOACs were included. Costs and health outcomes, measured as quality-adjusted life years (QALYs), were discounted at 3% per annum, in line with standard practice in the US setting. One-way deterministic and probabilistic sensitivity analyses (PSA) were undertaken. RESULTS: Lifetime per-patient cost for ICM was $31,116 versus $25,330 for SoC. ICMs generated a total of 7.75 QALYs versus 7.59 for SoC, with 34 fewer strokes projected per 1000 patients. The model estimates a number needed to treat of 29 per stroke avoided. The incremental cost-effectiveness ratio was $35,528 per QALY gained. ICMs were cost-effective in 75% of PSA simulations, using a $50,000 per QALY threshold, and a 100% probability of being cost-effective at a WTP threshold of $150,000 per QALY. CONCLUSIONS: The use of ICMs to identify AF in a high-risk population is likely to be cost-effective in the US healthcare setting.


Asunto(s)
Fibrilación Atrial , Humanos , Administración Oral , Anticoagulantes/administración & dosificación , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Análisis Costo-Beneficio , Hemorragia , Años de Vida Ajustados por Calidad de Vida , Accidente Cerebrovascular , Ensayos Clínicos como Asunto
5.
Diagnostics (Basel) ; 12(8)2022 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-36010327

RESUMEN

Despite advances in syncope evaluation strategies and risk stratification, the high cost of syncope is largely driven by extensive and often repetitive testing. This analysis of a large deidentified US claims database compared the use of diagnostic tests, therapeutic procedures, and the recurrence rate of acute syncope events before and after placement of an insertable cardiac monitor (ICM) in syncope patients. The patients had a minimum of 1 year of continuous enrollment before and 2 years after ICM placement. Among 2140 patients identified, a statistically significant reduction in the use of 14 out of 18 tests was observed during follow-up compared with pre-ICM testing. During the 2-year follow-up, 28.3% of patients underwent cardiac therapeutic interventions after a median of 127 days. Significantly fewer patients experienced acute syncope events during the 1st and 2nd years of ICM follow-up compared with the 1-year pre-ICM period, and the frequency of events per patient also decreased. In conclusion, reductions in diagnostic testing and acute syncope events were observed after ICM placement in a large real-world cohort of unexplained syncope patients. Further studies are needed to prospectively assess the impact of ICM vs. short-term monitoring on patient outcomes and healthcare utilization.

6.
Heart Rhythm O2 ; 3(3): 223-230, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35734289

RESUMEN

Background: Guidelines recommend a confirmed diagnosis of atrial fibrillation (AF) to initiate oral anticoagulation in cryptogenic stroke (CS) patients. However, the intermittent nature of AF can make detection challenging with intermittent short-term cardiac monitoring. Objective: The purpose of this retrospective cohort study was to examine post-CS utilization of cardiac monitoring and associated clinical outcomes. Methods: Adults with incident hospitalization for CS were identified in the Optum® claims database and assessed for cardiac monitoring received poststroke. Patient were stratified into those with a long-term insertable cardiac monitor (ICM) vs external cardiac monitor (ECM) only. The timing of ICM placement poststroke was treated as a time-dependent covariate. The clinical outcomes of interest were time to AF diagnosis, oral anticoagulation usage, and all-cause mortality. Results: A total of 12,994 patients met selection criteria for the analysis, of whom 1949 (15%) received an ICM and 11,045 (85%) received ECM only. In those who had received an ECM as their first monitoring modality, only 4.4% moved on to receive an ICM for longer-term monitoring. Use of ECM before ICM was associated with a longer time to AF diagnosis (median 336 vs 194 days). Compared to those with ECM only, ICM patients had a significantly lower rate of death (hazard ratio [HR] 0.70; P = .004), and faster time to AF diagnosis (HR 1.50; P <.0001) and anticoagulation initiation (HR 1.57; P <.0001) during follow-up of up to 5 years after CS. Conclusion: In a real-world study of CS patients, prolonged cardiac monitoring was associated with higher rates of AF detection and treatment, and higher odds of survival.

7.
PLoS One ; 17(6): e0270398, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35749428

RESUMEN

Diagnosing cardiac pauses that could produce syncopal episodes is important to guide appropriate therapy. However, the infrequent nature of these episodes can make detection challenging with conventional monitoring (CM) strategies with short-term ECG monitors. Insertable cardiac monitors (ICMs) continuously monitor for arrhythmias but present a higher up-front cost. It is not well understood whether these higher costs are offset by the costs of repeat evaluation in CM strategies. We simulated the likelihood of diagnostic success and cost-per-diagnosis of pause arrhythmias with CM strategies compared to ICM monitoring. ICM device data from syncope patients diagnosed with pause arrhythmias was utilized to simulate patient pathways and diagnostic success with CM. We assumed that detected true pause episodes (≥5 seconds) were symptomatic and prompted a hospital encounter and further evaluation with CM. Subsequent true pause episodes in yet-undiagnosed patients triggered additional rounds of CM. Costs of monitoring were accrued at each encounter and represent the U.S. payer perspective. Cost per diagnosed patient was calculated as the total costs accrued for all patients divided by the number of patients diagnosed, across 1,000 simulations. During a mean 505±333 days of monitoring ICM detected 2.4±2.7 pause events per patient, with an average of 109±94 days until the first event. CM was projected to diagnose between 13.8% (24-hour Holter) and 30.2% (two 30-day monitors) of the ICM-diagnosed patients. Total diagnostic costs per ICM-diagnosed patient averaged $7,847, whereas in the CM strategies average cost-per-diagnosis ranged from $12,950±2,589 with 24-hour Holter to $32,977±14,749 for two 30-day monitors. Relative to patients diagnosed with pause arrhythmias via ICM, CM strategies diagnose fewer patients and incur higher costs per diagnosed patient.


Asunto(s)
Fibrilación Atrial , Electrocardiografía Ambulatoria , Fibrilación Atrial/diagnóstico , Electrocardiografía , Humanos , Síncope/diagnóstico
8.
Heart Rhythm O2 ; 3(1): 79-90, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35243439

RESUMEN

BACKGROUND: Compared with short-term electrocardiogram (ECG) monitors, insertable cardiac monitors (ICMs) have been shown to increase atrial fibrillation (AF) detection rates and the opportunity to treat recurrent AF in patients postablation. OBJECTIVE: To examine healthcare utilization and clinical outcomes following AF ablation, in patients with vs without ICM. METHODS: Retrospective analysis pooling Optum Clinformatics and Medicare Fee-for-service 5% Sample claims databases. Patients with an AF ablation between January 1, 2011, and March 31, 2018 who received an ICM implant within 1 year pre-/postablation were propensity score matched 1:3 to patients without ICM. Outcomes included AF-related healthcare utilization, medication use, and occurrence of composite severe cardiovascular events (stroke / transient ischemic attack, major bleeds, systemic embolism, AF- or heart failure-related hospitalization, or death). RESULTS: A total of 1000 ICM patients and 2998 non-ICM patients were included. During mean follow-up of 33 ± 16 months postablation, ICM patients experienced significantly fewer severe cardiovascular events (1.09 ± 2.22 vs 1.37 ± 4.19, P = .008) and associated costs ($20,757 vs $29,106, P = .0005). ICM patients had a greater number of AF-related clinic visits (16.8 vs 11.6 visits, P < .0001) and were more likely to receive a repeat ablation (38.7% vs 32.4%, P = .0003). Total all-cause costs during follow-up were not statistically different. Discontinuation of oral anticoagulation was higher in ICM patients at 1 year (44% vs 31%, P < .0001) and 2 years (73% vs 64%, P = .0012). CONCLUSION: A shift from acute, reactive care to routine outpatient management was observed in patients with long-term ECG monitoring. Results suggest closer patient management in patients with long-term monitoring after an AF ablation and an improvement in outcomes, at similar overall cost.

9.
Am Heart J Plus ; 21: 100195, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38559748

RESUMEN

Background: Detection of atrial fibrillation (AF) in patients with embolic stroke of undetermined source (ESUS) is challenging due to its paroxysmal nature. We sought to assess AF detection with an insertable cardiac monitor (ICM) and to perform cost analysis for various AF monitoring strategies post-ESUS We applied this cost analysis modeling to recently published Stroke AF and Per Diem trials. Methods: Retrospective chart review was performed in consecutive hospitalized patients with ESUS who had ICM placed prior to discharge. Utilizing rate of ICM-detected AF and Medicare average payments, we modeled 30-day per-patient diagnostic costs of Immediate ICM insertion prior to discharge versus using a wearable monitor followed by ICM in patients with ESUS, from Medicare and patient out-of-pocket perspectives. Similar modeling strategy and cost analysis was applied to the Stroke AF and Per Diem trials. Results: In 192 ESUS patients, AF detection increased with length of monitoring: 7.3 % at 14 days, 9.4 % at 30 days, and 17.2 % after a median ~ 6 months (189 days). Cost modeling predicted that immediate ICM leads to $3683-$4070 lower Medicare payments per-patient and $1425-$1503 lower patient out-of-pocket costs compared to Wearable-to-ICM strategies. Using similar modeling in the PER DIEM and STROKE AF trials, the additive costs of the 30-day ELR to ICM strategy ranged from $3786-$3946 from a payer perspective and $1472-$1503 from a patient out-of-pocket perspective. Conclusions: Use of ICM immediately after ESUS is cost-saving compared to Wearable-to-ICM strategies, due to the cost and low diagnostic yield of short-term wearable cardiac monitoring.

10.
JMIR Cardio ; 5(2): e27720, 2021 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-34156344

RESUMEN

BACKGROUND: The number of patients with cardiac implantable electronic device (CIED) is increasing, creating a substantial workload for device clinics. OBJECTIVE: This study aims to characterize the workflow and quantify clinic staff time requirements for managing patients with CIEDs. METHODS: A time and motion workflow evaluation was performed in 11 US and European CIEDs clinics. Workflow tasks were repeatedly timed during 1 business week of observation at each clinic; these observations included all device models and manufacturers. The mean cumulative staff time required to review a remote device transmission and an in-person clinic visit were calculated, including all necessary clinical and administrative tasks. The annual staff time to manage a patient with a CIED was modeled using CIED transmission volumes, clinical guidelines, and the published literature. RESULTS: A total of 276 in-person clinic visits and 2173 remote monitoring activities were observed. Mean staff time required per remote transmission ranged from 9.4 to 13.5 minutes for therapeutic devices (pacemaker, implantable cardioverter-defibrillator, and cardiac resynchronization therapy) and from 11.3 to 12.9 minutes for diagnostic devices such as insertable cardiac monitors (ICMs). Mean staff time per in-person visit ranged from 37.8 to 51.0 and from 39.9 to 45.8 minutes for therapeutic devices and ICMs, respectively. Including all remote and in-person follow-ups, the estimated annual time to manage a patient with a CIED ranged from 1.6 to 2.4 hours for therapeutic devices and from 7.7 to 9.3 hours for ICMs. CONCLUSIONS: The CIED patient management workflow is complex and requires significant staff time. Understanding process steps and time requirements informs the implementation of efficiency improvements, including remote solutions. Future research should examine heterogeneity in patient management processes to identify the most efficient workflow.

11.
BMC Cardiovasc Disord ; 21(1): 160, 2021 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-33789592

RESUMEN

OBJECTIVE: Prevention of recurrent stroke in patients with embolic stroke of undetermined source (ESUS) is challenging. The advent of safer anticoagulation in the form of direct oral anticoagulants (DOACs) has prompted exploration of prophylactic anticoagulation for all ESUS patients, rather than anticoagulating just those with documented atrial fibrillation (AF). However, recent trials have failed to demonstrate a clinical benefit, while observing increased bleeding. We modeled the economic impact of anticoagulating ESUS patients without documented AF across multiple geographies. METHODS: CRYSTAL-AF trial data were used to assess ischaemic stroke event rates in ESUS patients confirmed AF-free after long-term monitoring. Anticipated bleeding event rates (including both minor and major bleeds) with aspirin, dabigatran 150 mg, and rivaroxaban 20 mg were sourced from published meta-analyses, whilst a 30% ischaemic stroke reduction for both DOACs was assumed. Cost data for clinical events and pharmaceuticals were collected from the local payer perspective. RESULTS: Compared with aspirin, dabigatran and rivaroxaban resulted in 17.9 and 29.9 additional bleeding events per 100 patients over a patient's lifetime, respectively. Despite incorporating into our model the proposed 30% reduction in ischaemic stroke risk, both DOACs were cost-additive over patient lifetime, as the costs of bleeding events and pharmaceuticals outweighed cost savings associated with the reduction in ischaemic strokes. DOACs added £5953-£7018 per patient (UK), €6683-€7368 (Netherlands), €4933-€9378 (Spain), AUD$5353-6539 (Australia) and $26,768-$32,259 (US) of payer cost depending on the agent prescribed. Additionally, in the U.S. patient pharmacy co-payments ranged from $2468-$12,844 depending on agent and patient plan. In all settings, cost-savings could not be demonstrated even when the modelling assumed 100% protection from recurrent ischaemic strokes, due to the very low underlying risk of recurrent ischaemic stroke in this population (1.27 per 100 patient-years). CONCLUSIONS: Anticoagulation of non-AF patients may cause excess bleeds and add substantial costs for uncertain benefits, suggesting a personalised approach to anticoagulation in ESUS patients.


Asunto(s)
Anticoagulantes/efectos adversos , Anticoagulantes/economía , Costos de los Medicamentos , Accidente Cerebrovascular Embólico/economía , Accidente Cerebrovascular Embólico/prevención & control , Hemorragia/inducido químicamente , Accidente Cerebrovascular Isquémico/economía , Accidente Cerebrovascular Isquémico/prevención & control , Prevención Secundaria/economía , Administración Oral , Anticoagulantes/administración & dosificación , Aspirina/efectos adversos , Aspirina/economía , Ensayos Clínicos como Asunto , Análisis Costo-Beneficio , Dabigatrán/efectos adversos , Dabigatrán/economía , Accidente Cerebrovascular Embólico/epidemiología , Humanos , Accidente Cerebrovascular Isquémico/epidemiología , Modelos Económicos , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Rivaroxabán/efectos adversos , Rivaroxabán/economía , Factores de Tiempo , Resultado del Tratamiento
12.
Open Heart ; 8(1)2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33622962

RESUMEN

INTRODUCTION: Early use of insertable cardiac monitor (ICM) is recommended for patients with unexplained syncope following initial clinical workup, due to its superior ability to establish symptom-rhythm correlation compared with conventional testing (CONV). However, ICMs incur higher upfront costs, and the impact of additional diagnoses and resulting treatment on downstream costs and outcomes is unclear. We aimed to evaluate the cost-effectiveness of ICM compared with CONV for the diagnosis of arrhythmia in patients with unexplained syncope, from a US payer perspective. METHODS: A Markov model was developed to estimate lifetime costs and benefits of arrhythmia diagnosis with ICM versus CONV, considering all related diagnostic and arrhythmia-related treatment costs and consequences. Cohort characteristics and costs were informed by original claims database analyses. Risks of mortality, syncopal recurrence, injury due to syncope and quality of life consequences from syncopal events were identified from the literature. RESULTS: ICM was less costly and more effective than CONV. Most of the observed US$4532 cost savings were attributed to reduced downstream diagnostic testing. For every 1000 patients, ICM was projected to yield an additional 253 arrhythmia diagnoses and lead to treatment in an additional 168 patients. The ICM strategy resulted in overall improved outcomes (0.30 quality-adjusted life years gained), due to a reduction in syncope recurrence and injury resulting from arrhythmia treatment. The results were robust to changes in the base case parameters but sensitive to the model time horizon, underlying probability of syncope recurrence and prevalence of arrhythmias. CONCLUSIONS: Our model projected that early ICM for the diagnosis of unexplained syncope reduced long-term costs, and led to an improvement in overall clinical outcomes by shortening time to arrhythmia treatment. The cost of ICM was outweighed by savings arising from fewer downstream diagnostic episodes, and the increased cost of treatment was counterbalanced by fewer syncope-related event costs.


Asunto(s)
Terapia de Resincronización Cardíaca/economía , Costos de la Atención en Salud/estadística & datos numéricos , Monitoreo Fisiológico/economía , Síncope/diagnóstico , Análisis Costo-Beneficio , Manejo de Datos , Humanos , Monitoreo Fisiológico/instrumentación , Años de Vida Ajustados por Calidad de Vida , Recurrencia , Estudios Retrospectivos , Síncope/economía , Síncope/terapia , Estados Unidos
13.
J Comp Eff Res ; 10(2): 127-141, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33300381

RESUMEN

Background: We assessed cost-effectiveness of insertable cardiac monitors (ICMs) in a US cryptogenic stroke population. Materials & methods: We modelled lifetime costs and quality-adjusted life years for three monitoring strategies post cryptogenic stroke: ICM starting immediately, ICM starting after Holter monitoring (delayed ICM) and standard of care involving intermittent ECG and Holter monitoring. Patient characteristics and detection efficacy were based on the CRYSTAL-AF trial. AF detection altered the modelled anticoagulation therapy and subsequent stroke and bleed risks. Results & conclusion: Immediate ICM was found to be cost-effective versus standard of care and cost-saving versus delayed ICM. Results were robust to sensitivity analyses. ICMs are a cost-effective diagnostic tool for the prevention of recurrent stroke in a US cryptogenic stroke population.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Análisis Costo-Beneficio , Electrocardiografía Ambulatoria , Humanos
14.
J Med Econ ; 23(7): 706-713, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32207636

RESUMEN

Background: Previous studies support operational benefits when moving insertable cardiac monitor (ICM) insertions outside the cardiac catheterization/electrophysiology laboratories, but this has not been directly assessed in a randomized trial or when the procedure is specifically moved to the office setting. To gain insight, the RIO 2 US study collected resource utilization and procedure time intervals for ICM insertion in-office and in-hospital and these data were used to calculate costs associated with staff time and supply use in each setting.Methods and results: The Reveal LINQ In-Office 2 US study (randomized [1:1], multicenter, unblinded) included 482 patients to undergo insertion of the ICM in-hospital (in an operating room or CATH/EP laboratory) (n = 251) or in-office (n = 231). Detailed information on resource utilization was collected prospectively by the study and used to compare resource utilization and procedure time intervals during ICM insertion procedures performed in-office vs. in-hospital. In addition, costs associated with staff time and supply use in each setting were calculated retrospectively. Total visit duration (check-in to discharge) was 107 min shorter in-office vs. in-hospital (95% CI = 97-116 min; p < 0.001). Patient preparation and education in-office were more likely to occur in the same room as the procedure, compared with in-hospital (91.6% vs. 34.2%, p < 0.001 and 87.3% vs. 22.1%, p < 0.001, respectively). There was a reduction in registered nurse and cardiovascular/operating room technologist involvement in-office, accompanied by higher physician and medical assistant participation. Overall staff time spent per case was 75% higher in-hospital, leading to 50% higher staffing costs compared to in-office.Conclusions: ICM insertion in a physician's office vs. a hospital setting resulted in reduced patient visit time and reduced overall staff time, with a consequent reduction in staffing costs. Clinical trial registration: ClinicalTrials.gov NCT02395536.


Asunto(s)
Desfibriladores Implantables , Recursos en Salud , Miniaturización , Consultorios Médicos , Servicio de Cirugía en Hospital , Procedimientos Quirúrgicos Operativos/economía , Recursos en Salud/estadística & datos numéricos , Humanos , Seguridad del Paciente
15.
Patient Prefer Adherence ; 11: 947-958, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28572722

RESUMEN

BACKGROUND: Shared decision-making (SDM), a process whereby physicians and patients collaborate to select interventions, is not well understood for biologic treatment of autoimmune conditions. METHODS: This was a cross-sectional survey of adults initiating treatment for Crohn's disease or ulcerative colitis (inflammatory bowel disease, IBD) or psoriatic arthritis or rheumatoid arthritis (RA/PA). Survey data were linked to administrative claims for 6 months before (baseline) and after (follow-up) therapy initiation. Measures included the Shared Decision Making Questionnaire, Patient Activation Measure (PAM), Morisky Medication Adherence Scale (MMAS), general health, and treatment satisfaction. Claims-based Quan-Charlson comorbidity scores, persistence, medication possession ratio (MPR), and health care costs were examined. Patients were compared by participation (SDM) and nonparticipation (non-SDM) in SDM. RESULTS: Among 453 respondents, 357 were eligible, and 306 patients (204 RA/PA and 102 IBD) were included in all analyses. Overall (n=357), SDM participants (n=120) were more often females (75.0% vs 62.5%, P=0.018), had lower health status (48.0 vs 55.4, P=0.005), and higher Quan-Charlson scores (1.0 vs 0.7, P=0.035) than non-SDM (n=237) participants. Lower MMAS scores (SDM 0.17 vs non-SDM 0.41; P<0.05) indicated greater likelihood of adherence; SDM participants also reported higher satisfaction with medication and had greater activation (PAM: SDM vs non-SDM: 66.9 vs 61.6; P<0.001). Mean MPR did not differ, but persistence was longer among SDM participants (111.2 days vs 102.2 days for non-SDM; P=0.029). Costs did not differ by SDM status overall, or among patients with RA/PA. The patients with IBD, however, experienced lower (P=0.003) total costs ($9,404 for SDM vs $25,071 for non-SDM) during follow-up. CONCLUSION: This study showed greater likelihood of adherence and satisfaction for patients who engaged in SDM and reduced health care costs among patients with IBD who engaged in SDM. This study provides a basis for defining SDM participation and detecting differences by SDM participation for biologic treatment selection for autoimmune conditions.

16.
Psychosomatics ; 55(5): 469-77, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24360523

RESUMEN

OBJECTIVE: Given the limited literature reporting on the medical comorbidity of patients attending psychiatric day treatment, we studied the medical status and care of a cohort of 100 patients for 1 year following enrollment in a day treatment program at a public sector hospital. METHODS: Data were abstracted from electronic medical records retrospectively for the year following day treatment enrollment. Study variables included lifetime medical and psychiatric diagnoses documented in the medical record, patient measures performed during the study year (including laboratory, diagnostic, and physical measures), current medication, and encounters within the hospital system. RESULTS: Despite an average age of only 41 years for the cohort, 80% had 1 or more major medical diagnoses. For the 57 subjects with laboratory studies performed during the 1-year study interval, more than half had abnormal results. Forty-three subjects had no laboratory studies during the study interval. Forty-four were seen in the emergency room and an equal number in the medicine clinic. CONCLUSIONS: The occurrence of medical co-morbidity in this population was alarmingly high. The vigor of medical care provided was greater than one would expect for a psychiatric population averaging 41 years of age, although there were inadequacies reflecting a lack of standardized medical assessment at entry to day treatment. We propose a reconceptualization for day treatment, incorporating full medical screening as a standard component of entrance into day treatment.


Asunto(s)
Indicadores de Salud , Trastornos Mentales/terapia , Adulto , Atención Ambulatoria , Comorbilidad , Femenino , Humanos , Masculino , Trastornos Mentales/diagnóstico , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...