1.
J Hosp Infect ; 96(4): 392-395, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28622979

RESUMEN

Acquisition of Legionnaires' disease is a serious complication of hospitalization. Rapid determination of whether or not the infection is caused by strains of Legionella pneumophila in the hospital environment is crucial to avoid further cases. This study investigated the use of whole-genome sequencing to identify the source of infection in hospital-acquired Legionnaires' disease. Phylogenetic analyses showed close relatedness between one patient isolate and a strain found in hospital water, confirming suspicion of nosocomial infection. It was found that whole-genome sequencing can be a useful tool in the investigation of hospital-acquired Legionnaires' disease.


Asunto(s)
Infección Hospitalaria/microbiología , Microbiología Ambiental , Legionella pneumophila/clasificación , Enfermedad de los Legionarios/microbiología , Epidemiología Molecular/métodos , Tipificación Molecular/métodos , Secuenciación Completa del Genoma/métodos , Análisis por Conglomerados , Humanos , Legionella pneumophila/genética , Legionella pneumophila/aislamiento & purificación , Filogenia , Homología de Secuencia