Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Pharmeur Bio Sci Notes ; 2017: 44-68, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29017702

RESUMEN

Before release onto the market, it must be demonstrated that the total and free polysaccharide (poly ribosyl-ribitol-phosphate, PRP) content of Haemophilus influenzae type b (Hib) vaccine complies with requirements. However, manufacturers use different methods to assay PRP content: a national control laboratory must establish and validate the relevant manufacturer methodology before using it to determine PRP content. An international study was organised by the World Health Organization (WHO), in collaboration with the Biological Standardisation Programme (BSP) of the Council of Europe/European Directorate for the Quality of Medicines & HealthCare (EDQM) and of the European Union Commission, to verify the suitability of a single method for determining PRP content in liquid pentavalent vaccines (DTwP-HepB-Hib) containing a whole-cell pertussis component. It consists of HCl hydrolysis followed by chromatographic separation and quantification of ribitol on a CarboPac MA1 column using high-performance anion exchange chromatography coupled with pulsed amperometric detection (HPAEC-PAD). The unconjugated, free, PRP is separated from the total PRP using C4 solid-phase extraction cartridges (SPE C4). Ten quality control laboratories performed two independent analyses applying the proposed analytical test protocol to five vaccine samples, including a vaccine lot with sub-potent PRP content and very high free PRP content. Both WHO PRP standard and ribitol reference standard were included as calibrating standards. A significant bias between WHO PRP standard and ribitol reference standard was observed. Study results showed that the proposed analytical method is, in principle, suitable for the intended use provided that a validation is performed as usually expected from quality control laboratories.


Asunto(s)
Cromatografía Líquida de Alta Presión/normas , Cromatografía por Intercambio Iónico/normas , Vacuna contra Difteria, Tétanos y Tos Ferina/análisis , Vacunas contra Haemophilus/análisis , Haemophilus influenzae tipo b/inmunología , Vacunas contra Hepatitis B/análisis , Polisacáridos Bacterianos/análisis , Polisacáridos/análisis , Cápsulas Bacterianas/inmunología , Vacuna contra Difteria, Tétanos y Tos Ferina/inmunología , Vacuna contra Difteria, Tétanos y Tos Ferina/normas , Composición de Medicamentos , Europa (Continente) , Vacunas contra Haemophilus/inmunología , Vacunas contra Haemophilus/normas , Vacunas contra Hepatitis B/inmunología , Vacunas contra Hepatitis B/normas , India , Polisacáridos/inmunología , Polisacáridos/normas , Polisacáridos Bacterianos/inmunología , Polisacáridos Bacterianos/normas , Control de Calidad , Estándares de Referencia , Reproducibilidad de los Resultados , República de Corea
2.
Pharmeuropa Bio ; 2005(1): 31-52, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16336937

RESUMEN

This paper describes a double antigen ELISA (DAE) for rapid, specific and reliable assessment of the antitetanus immune status of horses and sheep. Compared with the indirect ELISA, the double antigen ELISA has the advantage of species-independent testing of sera. Thanks to its test design, it is more specific since the detected antibodies are forced to bind tetanus toxoid twice. In addition, it is very sensitive to tetanus antibodies, enabling the detection of low antibody titres, in range which is relevant for the assessment of the protective status (tetanus toxin neutralising antibodies). The detection limit of the DAE for tetanus antibodies is in the order of 10(-4) EU/ml. A comparison of in vitro results of individual sera with in vivo titres showed that horse sera with titres of 0.04 and 0.05 EU/ml in the DAE showed titres of > 0.05 IU and 0.034 IU/ml respectively during in vivo testing thus indicating good agreement. For tested sheep sera which were rated > 0.05 IU/ml in vivo, the corresponding titre in the DAE was 0.24 EU/ml. Clear tetanus antitoxin establishment of protective ELISA limits requires further comparative examination of sera with low titres (< 1.0 EU/ml) in the double antigen ELISA and the toxin neutralisation test. With the double antigen ELISA, efficacy can be determined for marketing authorisation procedures of tetanus vaccines ad us. vet. As a consequence, the toxin neutralisation test (still being the standard method of choice for quantifying tetanus toxin neutralising antitoxin titres) could be replaced, since it requires too great a number of animals per test and involves considerable suffering for the animals. The test described here reduces the use of mice and guinea pigs within vaccine efficacy testing. In addition, it involves less exposure of the laboratory personnel to toxin.


Asunto(s)
Vacunas Bacterianas/normas , Toxoide Tetánico/normas , Tétanos/inmunología , Animales , Ensayo de Inmunoadsorción Enzimática/métodos , Caballos , Control de Calidad , Reproducibilidad de los Resultados , Ovinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...