Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Bone Joint Res ; 4(2): 17-22, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25673625

RESUMEN

OBJECTIVES: The purpose of this study was to investigate whether the femoral head-neck contour, characterised by the alpha angle, varies with the stage of physeal maturation using MRI evaluation of an asymptomatic paediatric population. METHODS: Paediatric volunteers with asymptomatic hips were recruited to undergo MRI of both hips. Femoral head physes were graded from 1 (completely open) to 6 (completely fused). The femoral head-neck contour was evaluated using the alpha angle, measured at the 3:00 (anterior) and 1:30 (anterosuperior) positions and correlated with physeal grade, with gender sub-analysis performed. RESULTS: A total of 43 asymptomatic paediatric volunteers (26 male, 17 female) with mean age 13.0 years (eight to 18) were included with review of bilateral hip MRIs. Correlation between the physeal grade and alpha angle was moderate in males at both the 3:00 (r = 0.477, p < 0.001) and 1:30 (r = 0.509, p < 0.001) positions, whereas there was no significant correlation in females. A significant difference was found between the alpha angles of all the physeal grades (3:00, p = 0.030, 1:30, p = 0.005), but only in males, with the angle increasing with higher grades. For physeal grading, the inter-reader reliability was substantial (intraclass correlation coefficient (ICC) = 0.694), and the intra-reader reliability was also substantial (ICC = 0.788). CONCLUSION: The femoral head-neck contour varies and correlates with the stage of physeal development, but only in males, with the alpha angle increasing with progressive physeal maturation. This suggests that gender differences exist in the natural physiological growth, development or remodelling of femoral head-neck junction. In males, pre-physeal fusion may be a critical period of vulnerability for development of morphologic abnormalities of the femoral head-neck junction. Cite this article: Bone Joint Res 2015;4:17-22.

2.
Placenta ; 35(9): 784-6, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25043672

RESUMEN

We evaluated whether preeclampsia is associated with elevated circulating levels of High mobility group box 1 protein (HMGB-1), a nuclear protein with proinflammatory effects when released extracellularly. We enrolled 48 women, 32 in third trimester pregnancy (16 with, 16 without preeclampsia), and 16 healthy non pregnant. In the peripheral blood of pregnant women, HMGB-1 concentration was assessed serially, before and after delivery. With or without preeclampsia, third trimester pregnancy was associated with elevated levels of HMGB-1. This elevation is exaggerated in preeclampsia. The source of HMGB-1 observed in these conditions is likely to involve tissues other than the placenta itself.


Asunto(s)
Proteína HMGB1/sangre , Preeclampsia/sangre , Adulto , Estudios de Casos y Controles , Femenino , Humanos , Embarazo
3.
J Neuroradiol ; 38(3): 148-55, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20728218

RESUMEN

PURPOSE: To evaluate the agreement and diagnostic accuracy of Contrast enhanced magnetic resonance angiography (CE-MRA), Doppler ultrasound (DUS) and Digital subtraction angiography (DSA) in the assessment of carotid stenosis. METHODS: DUS, CE-MRA and DSA were performed in 56 patients included in the Carotide-angiographie par résonance magnétique-échographie-doppler-angioscanner (CARMEDAS) multicenter study with a carotid stenosis ≥ 50%. Three readers evaluated stenoses on CE-MRA and DSA (NASCET criteria). Velocities criteria were used for stenosis estimation on DUS. RESULTS: CE-MRA had a sensitivity and specificity of 96-98% and 66-83% respectively for carotid stenoses ≥ 50% and a sensitivity and specificity of 94% and 76-84% respectively for carotid stenoses ≥ 70%. The interobserver agreement of CE-MRA was excellent, except for moderate stenoses (50-69%). DUS had a sensitivity and specificity of 88 and 75% respectively for carotid stenoses ≥ 50% and a sensitivity and specificity of 83 and 86% respectively for carotid stenoses ≥ 70%. Combined concordant CE-MRA and DUS had a sensitivity and specificity of 100 and 85-90% respectively for carotid stenoses ≥ 50% and a sensitivity and specificity of 96-100% and 80-87% respectively for carotid stenoses ≥ 70%. The positive predictive value of the association CE-MRA and DUS for carotid stenoses ≥ 70% is calculated between 77 and 82% while the negative predictive value is calculated between 97 and 100%. CE-MRA and DUS have concordant findings in 63-72%, and the overestimations cases were recorded only for carotid stenosis ≤ 69%. CONCLUSION: Combined DUS-CE-MRA is excellent for evaluation of severe stenosis but remains debatable in moderate stenosis (50-69%) due to the risk of overestimations.


Asunto(s)
Estenosis Carotídea/diagnóstico , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Ultrasonografía Doppler , Anciano , Anciano de 80 o más Años , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/patología , Medios de Contraste , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
4.
Neurology ; 66(1): 118-20, 2006 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-16401860

RESUMEN

The authors sought to determine in a retrospective analysis whether carotid plaque soft TD on CT is associated with recent ischemic neurologic events. Among 141 patients (99 asymptomatic), 106 plaques with more than 50% stenosis were selected for density measurements. They found an odds ratio for neurologic events associated with a 10-point decrease in density of 1.54 (p = 0.002), showing an association between plaque density and neurologic events.


Asunto(s)
Isquemia Encefálica/diagnóstico por imagen , Arteria Carótida Interna/diagnóstico por imagen , Arteria Carótida Interna/patología , Estenosis Carotídea/diagnóstico por imagen , Accidente Cerebrovascular/diagnóstico por imagen , Tomografía Computarizada por Rayos X/normas , Anciano , Anciano de 80 o más Años , Biomarcadores , Isquemia Encefálica/fisiopatología , Arteria Carótida Interna/fisiopatología , Estenosis Carotídea/fisiopatología , Medios de Contraste , Femenino , Humanos , Ataque Isquémico Transitorio/diagnóstico por imagen , Ataque Isquémico Transitorio/fisiopatología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Ensayos Clínicos Controlados Aleatorios como Asunto/estadística & datos numéricos , Estudios Retrospectivos , Accidente Cerebrovascular/fisiopatología
5.
Oftalmologia ; 34(1): 35-8, 1990.
Artículo en Rumano | MEDLINE | ID: mdl-2101029

RESUMEN

The paper reports a study on the involvement of the visual system during work at video terminal. The results of the investigations on a group of operators in a computation centre were used for describing an optimum anatomicofunctional visual type for work at video terminal and the hygiene rules to be observed during work at the computer screen.


Asunto(s)
Terminales de Computador , Ergonomía , Oftalmopatías/etiología , Enfermedades Profesionales/etiología , Trastornos de la Visión/etiología , Oftalmopatías/diagnóstico , Oftalmopatías/prevención & control , Humanos , Higiene , Enfermedades Profesionales/diagnóstico , Enfermedades Profesionales/prevención & control , Trastornos de la Visión/diagnóstico , Trastornos de la Visión/prevención & control
6.
Artículo en Rumano | MEDLINE | ID: mdl-2533366

RESUMEN

The authors used the discrimination method--pseudoisochromatic phases and the comparison-assortment method for the chromatic sense examination in a group of subjects working in the motor transport and chemical textile dying. Computer programs were devised for examination data processing and for diagnosis display. After each testing, the data of each subject are added to the patient's card to be subsequently looked up and used for statistics.


Asunto(s)
Pruebas de Percepción de Colores/métodos , Diagnóstico por Computador/métodos , Conducción de Automóvil , Defectos de la Visión Cromática/diagnóstico , Femenino , Humanos , Masculino , Rumanía , Industria Textil
7.
Anal Biochem ; 146(2): 299-306, 1985 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-3875297

RESUMEN

The new type of test tablets (Iodocrom) for alpha-amylase assay contain crosslinked (CL)-amylose or CL-starch (specific substrates for alpha-amylase only) and the reagent (KIO3/KI) generating iodine (in acidic medium, when the reaction is stopped). The method--amyloclastic in nature--is based on selective action of alpha-amylase on the CL-substrate liberating soluble polysaccharide chains large enough and in a conformation suitable to allow the formation of iodine inclusion complexes. Unlike the classical iodometric methods, the reaction is followed by an increase in iodine complex blue color. The method has some common points with the well-known chromogenic (e.g., Phadebas) methods. Both use insoluble substrates which are not susceptible to attack by exoamylases and in both cases the enzymatic reaction is followed by the release of soluble products. The amounts of these released chains and the absorbances of their inclusion complexes with iodine are in a linear dependence with the enzyme concentration (activity).


Asunto(s)
Compuestos de Potasio , alfa-Amilasas/análisis , Humanos , Yodatos , Potasio , Yoduro de Potasio , Juego de Reactivos para Diagnóstico , Saliva/enzimología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA