Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Opt Lett ; 47(14): 3511-3514, 2022 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-35838716

RESUMEN

We report on the generation of GW-class peak power, 35-fs pulses at 2-µm wavelength with an average power of 51 W at 300-kHz repetition rate. A compact, krypton-filled Herriott-type cavity employing metallic mirrors is used for spectral broadening. This multi-pass compression stage enables the efficient post compression of the pulses emitted by an ultrafast coherently combined thulium-doped fiber laser system. The presented results demonstrate an excellent preservation of the input beam quality in combination with a power transmission as high as 80%. These results show that multi-pass cell based post-compression is an attractive alternative to nonlinear spectral broadening in fibers, which is commonly employed for thulium-doped and other mid-infrared ultrafast laser systems. Particularly, the average power scalability and the potential to achieve few-cycle pulse durations make this scheme highly attractive.

2.
Opt Express ; 29(24): 40333-40344, 2021 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-34809377

RESUMEN

Short-pulse metrology and dynamic studies in the extreme ultraviolet (XUV) spectral range greatly benefit from interferometric measurements. In this contribution a Michelson-type all-reflective split-and-delay autocorrelator operating in a quasi amplitude splitting mode is presented. The autocorrelator works under a grazing incidence angle in a broad spectral range (10 nm - 1 µm) providing collinear propagation of both pulse replicas and thus a constant phase difference across the beam profile. The compact instrument allows for XUV pulse autocorrelation measurements in the time domain with a single-digit attosecond precision and a useful scan length of about 1 ps enabling a decent resolution of E/ΔE = 2000 at 26.6 eV. Its performance for selected spectroscopic applications requiring moderate resolution at short wavelengths is demonstrated by characterizing a sharp electronic transition at 26.6 eV in Ar gas. The absorption of the 11th harmonic of a frequency-doubled Yb-fiber laser leads to the well-known 3s3p64p1P1 Fano resonance of Ar atoms. We benchmark our time-domain interferometry results with a high-resolution XUV grating spectrometer and find an excellent agreement. The common-path interferometer opens up new opportunities for short-wavelength femtosecond and attosecond pulse metrology and dynamic studies on extreme time scales in various research fields.

3.
Light Sci Appl ; 10(1): 36, 2021 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-33579895

RESUMEN

Bright, coherent soft X-ray radiation is essential to a variety of applications in fundamental research and life sciences. To date, a high photon flux in this spectral region can only be delivered by synchrotrons, free-electron lasers or high-order harmonic generation sources, which are driven by kHz-class repetition rate lasers with very high peak powers. Here, we establish a novel route toward powerful and easy-to-use SXR sources by presenting a compact experiment in which nonlinear pulse self-compression to the few-cycle regime is combined with phase-matched high-order harmonic generation in a single, helium-filled antiresonant hollow-core fibre. This enables the first 100 kHz-class repetition rate, table-top soft X-ray source that delivers an application-relevant flux of 2.8 × 106 photon s-1 eV-1 around 300 eV. The fibre integration of temporal pulse self-compression (leading to the formation of the necessary strong-field waveforms) and pressure-controlled phase matching will allow compact, high-repetition-rate laser technology, including commercially available systems, to drive simple and cost-effective, coherent high-flux soft X-ray sources.

4.
Opt Express ; 26(15): 19318-19327, 2018 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-30114107

RESUMEN

Separation of the high average power driving laser beam from the generated XUV to soft-X-ray radiation poses great challenges in collinear HHG setups due to the losses and the limited power handling capabilities of the typically used separating optics. This paper demonstrates the potential of driving HHG with annular beams, which allow for a straightforward and power scalable separation via a simple pinhole, resulting in a measured driving laser suppression of 5⋅10-3. The approach is characterized by an enormous flexibility as it can be applied to a broad range of input parameters and generated photon energies. Phase matching aspects are analyzed in detail and an HHG conversion efficiency that is only 27% lower than using a Gaussian beam under identical conditions is demonstrated, revealing the viability of the annular beam approach for high flux coherent short-wavelength sources and high average power driving lasers.

5.
Sci Rep ; 8(1): 8677, 2018 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-29875479

RESUMEN

Today, coherent imaging techniques provide the highest resolution in the extreme ultraviolet (XUV) and X-ray regions. Fourier transform holography (FTH) is particularly unique, providing robust and straightforward image reconstruction at the same time. Here, we combine two important advances: First, our experiment is based on a table-top light source which is compact, scalable and highly accessible. Second, we demonstrate the highest resolution ever achieved with FTH at any light source (34 nm) by utilizing a high photon flux source and cutting-edge nanofabrication technology. The performance, versatility and reliability of our approach allows imaging of complex wavelength-scale structures, including wave guiding effects within these structures, and resolving embedded nanoscale features, which are invisible for electron microscopes. Our work represents an important step towards real-world applications and a broad use of XUV imaging in many areas of science and technology. Even nanoscale studies of ultra-fast dynamics are within reach.

6.
Opt Lett ; 41(22): 5170-5173, 2016 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-27842085

RESUMEN

We present a table-top coherent diffractive imaging (CDI) experiment based on high-order harmonics generated at 18 nm by a high average power femtosecond fiber laser system. The high photon flux, narrow spectral bandwidth, and high degree of spatial coherence allow for ultrahigh subwavelength resolution imaging at a high numerical aperture. Our experiments demonstrate a half-pitch resolution of 15 nm, close to the actual Abbe limit of 12 nm, which is the highest resolution achieved from any table-top extreme ultraviolet (XUV) or x-ray microscope. In addition, sub-30 nm resolution was achieved with only 3 s of integration time, bringing live diffractive imaging and three-dimensional tomography on the nanoscale one step closer to reality. The current resolution is solely limited by the wavelength and the detector size. Thus, table-top nanoscopes with only a few-nanometer resolutions are in reach and will find applications in many areas of science and technology.

7.
Opt Express ; 24(19): 22013-27, 2016 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-27661936

RESUMEN

Lensless coherent diffractive imaging usually requires iterative phase-retrieval for recovering the missing phase information. Holographic techniques, such as Fourier-transform holography (FTH) or holography with extended references (HERALDO), directly provide this phase information and thus allow for a direct non-iterative reconstruction of the sample. In this paper, we analyze the effect of detector noise on the reconstruction for FTH and HERALDO with linear and rectangular references. We find that HERALDO is more sensitive to this type of noise than FTH, especially if rectangular references are employed. This excessive noise, caused by the necessary differentiation step(s) during reconstruction in case of HERALDO, additionally depends on the numerical implementation. When considering both shot-noise and detector noise, we find that FTH provides a better signal-to-noise ratio (SNR) than HERALDO if the available photon flux from the light source is low. In contrast, at high photon flux HERALDO provides better SNR and resolution than FTH. Our findings will help in designing optimum holographic imaging experiments particularly in the photon-flux-limited regime where most ultrafast experiments operate.

8.
Sci Rep ; 4: 7356, 2014 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-25483626

RESUMEN

Coherent Diffraction Imaging is a technique to study matter with nanometer-scale spatial resolution based on coherent illumination of the sample with hard X-ray, soft X-ray or extreme ultraviolet light delivered from synchrotrons or more recently X-ray Free-Electron Lasers. This robust technique simultaneously allows quantitative amplitude and phase contrast imaging. Laser-driven high harmonic generation XUV-sources allow table-top realizations. However, the low conversion efficiency of lab-based sources imposes either a large scale laser system or long exposure times, preventing many applications. Here we present a lensless imaging experiment combining a high numerical aperture (NA = 0.8) setup with a high average power fibre laser driven high harmonic source. The high flux and narrow-band harmonic line at 33.2 nm enables either sub-wavelength spatial resolution close to the Abbe limit (Δr = 0.8λ) for long exposure time, or sub-70 nm imaging in less than one second. The unprecedented high spatial resolution, compactness of the setup together with the real-time capability paves the way for a plethora of applications in fundamental and life sciences.

9.
Opt Express ; 22(15): 17607-19, 2014 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-25089381

RESUMEN

The potential of borate crystals, BBO, LBO and BiBO, for high average power scaling of optical parametric chirped-pulse amplifiers is investigated. Up-to-date measurements of the absorption coefficients at 515 nm and the thermal conductivities are presented. The measured absorption coefficients are a factor of 10-100 lower than reported by the literature for BBO and LBO. For BBO, a large variation of the absorption coefficients was found between crystals from different manufacturers. The linear and nonlinear absorption coefficients at 515 nm as well as thermal conductivities were determined for the first time for BiBO. Further, different crystal cooling methods are presented. In addition, the limits to power scaling of OPCPAs are discussed.

10.
Opt Lett ; 37(23): 4910-2, 2012 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-23202087

RESUMEN

It is shown that timing jitter in optical parametric chirped-pulse amplification induces spectral drifts that transfer to carrier-envelope phase (CEP) instabilities via dispersion. Reduction of this effect requires temporal synchronization, which is realized with feedback obtained from the angularly dispersed idler. Furthermore, a novel method to measure the CEP drifts by utilizing parasitic second harmonic generation within parametric amplifiers is presented. Stabilization of the timing allows the obtainment of a CEP stability of 86 mrad over 40 min at 150 kHz repetition rate.

11.
Opt Express ; 19(20): 19374-83, 2011 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-21996878

RESUMEN

The process of high harmonic generation allows for coherent transfer of infrared laser light to the extreme ultraviolet spectral range opening a variety of applications. The low conversion efficiency of this process calls for optimization or higher repetition rate intense ultrashort pulse lasers. Here we present state-of-the-art fiber laser systems for the generation of high harmonics up to 1 MHz repetition rate. We perform measurements of the average power with a calibrated spectrometer and achieved µW harmonics between 45 nm and 61 nm (H23-H17) at a repetition rate of 50 kHz. Additionally, we show the potential for few-cycle pulses at high average power and repetition rate that may enable water-window harmonics at unprecedented repetition rate.


Asunto(s)
Amplificadores Electrónicos , Transferencia de Energía , Rayos Láser , Luz , Modelos Teóricos , Oscilometría/métodos , Dispersión de Radiación , Simulación por Computador , Diseño de Equipo , Procesamiento de Señales Asistido por Computador/instrumentación
12.
Opt Express ; 19(18): 16797-808, 2011 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-21935041

RESUMEN

The influence of parasitic processes on the performance of ultra-broadband noncollinear optical parametric amplifiers (NOPA's) is investigated for walk-off and non-walk-off compensating configurations. Experimental results with a white-light-seeded NOPA agree well with numerical simulations. The same model shows that 10% of the output energy of an amplified signal can be transferred into a parasitic second harmonic of the signal. These findings are supported by quantitative measurements on a few-cycle NOPA, where a few percent of the signal energy is converted to its second harmonic in the walk-off compensating case. This effect is reduced by an order of magnitude in the non-walk-off compensating configuration. A detailed study of the phase-matching conditions of the most common nonlinear crystals provides guidelines for designing NOPA systems.

13.
Opt Express ; 19(8): 7546-52, 2011 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-21503062

RESUMEN

We present simple and compact (1.5m x 0.5m footprint) post-compression of a state-of-the-art fiber chirped pulse amplification system. By using two stage nonlinear compression in noble gas filled hollow core fibers we shorten 1 mJ, 480 fs, 50 kHz pulses. The first stage is a 53 cm long, 200 µm inner diameter fiber filled with xenon with subsequent compression in a chirped mirror compressor. A 20 cm, 200 µm inner diameter fiber filled with argon further broadens the spectrum in a second stage and compression is achieved with another set of chirped mirrors. The average power is 24.5 W/19 W after the first/second stage, respectively. Compression to 35 fs is achieved. Numerical simulations, agreeing well with experimental data, yield a peak power of 5.7 GW at a pulse energy of 380 µJ making this an interesting source for high harmonic generation at high repetition rate and average power.

14.
Opt Express ; 19(5): 4421-7, 2011 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-21369273

RESUMEN

In this paper we describe a high power narrow-band amplified spontaneous emission (ASE) light source at 1030 nm center wavelength generated in an Yb-doped fiber-based experimental setup. By cutting a small region out of a broadband ASE spectrum using two fiber Bragg gratings a strongly constrained bandwidth of 12±2 pm (3.5±0.6 GHz) is formed. A two-stage high power fiber amplifier system is used to boost the output power up to 697 W with a measured beam quality of M2≤1.34. In an additional experiment we demonstrate a stimulated Brillouin scattering (SBS) suppression of at least 17 dB (theoretically predicted ~20 dB), which is only limited by the dynamic range of the measurement and not by the onset of SBS when using the described light source. The presented narrow-band ASE source could be of great interest for brightness scaling applications by beam combination, where SBS is known as a limiting factor.


Asunto(s)
Amplificadores Electrónicos , Tecnología de Fibra Óptica/instrumentación , Rayos Láser , Refractometría/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo
15.
Opt Express ; 18(19): 20242-50, 2010 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-20940915

RESUMEN

Significant progress in high repetition rate ultrashort pulse sources based on fiber technology is presented. These systems enable operation at a high repetition rate of up to 500 kHz and high average power in the extreme ultraviolet wavelength range via high harmonic generation in a gas jet. High average power few-cycle pulses of a fiber amplifier pumped optical parametric chirped pulse amplifier are used to produce µW level average power for the strongest harmonic at 42.9 nm at a repetition rate of 96 kHz.


Asunto(s)
Amplificadores Electrónicos , Tecnología de Fibra Óptica/instrumentación , Láseres de Estado Sólido , Diseño de Equipo , Análisis de Falla de Equipo
16.
Opt Express ; 18(12): 12719-26, 2010 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-20588400

RESUMEN

We report on a high power optical parametric amplifier delivering 8 fs pulses with 6 GW peak power. The system is pumped by a fiber amplifier and operated at 96 kHz repetition rate. The average output power is as high as 6.7 W, which is the highest average power few-cycle pulse laser reported so far. When stabilizing the seed oscillator, the system delivered carrier-envelop phase stable laser pulses. Furthermore, high harmonic generation up to the 33(th) order (21.8 nm) is demonstrated in a Krypton gas jet. In addition, the scalability of the presented laser system is discussed.

17.
Opt Express ; 18(5): 4689-94, 2010 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-20389481

RESUMEN

We report on the performance of a 60 kHz repetition rate sub-10 fs, optical parametric chirped pulse amplifier system with 2 W average power and 3 GW peak power. This is to our knowledge the highest average power sub-10 fs kHz-amplifier system reported to date. The amplifier is conceived for applications at free electron laser facilities and is designed such to be scalable in energy and repetition rate.

18.
Opt Express ; 18(3): 3158-67, 2010 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-20174154

RESUMEN

An optical parametric amplifier that delivers nearly transform limited pulses is presented. The center wavelength of these pulses can be tuned between 993 nm and 1070 nm and, at the same time, the pulse duration is varied between 206 fs and 650 fs. At the shortest pulse duration the pulse energy was increased up to 7.2 microJ at 50 kHz repetition rate. Variation of the wavelength is achieved by applying a tunable cw seed while the pulse duration can be varied via altering the pump pulse duration. This scheme offers superior flexibility and scaling possibilities.

19.
Opt Express ; 17(18): 16332-41, 2009 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-19724632

RESUMEN

We present a simple and robust pulse shaping device based on coherent pulse stacking. The device is embedded in a polarisation maintaining step index fiber. An input pulse is sent through a fiber optical circulator. Up to four pulse replicas are reflected by fiber Bragg gratings and interfere at the output. Temperature control allows tuning of the relative pulse phases of the sub-pulses. Additionally fine tuning of the sub-pulse amplitudes is demonstrated. We experimentally generated 235 ps and 416 ps long flattop pulses with rising and falling edges shorter than 100 ps. In contrast to other pulse shaping techniques the presented setup is robust, alignment free, provides excellent beam quality and is also suitable for pulse durations up to several nanoseconds.

20.
Opt Express ; 17(7): 5153-62, 2009 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-19333279

RESUMEN

We report on a significant improvement of the total bandwidth amplified in an optical parametric process. By pumping a parametric amplifier with a broadband pump, we demonstrate amplification of a supercontinuum whose spectrum expands over nearly an octave ranging from less than 600 nm up to 1200 nm. Our amplifier stage is set to provide amplification at degeneracy in the quasi-collinear configuration with a temporally as well as angularly dispersed pump.


Asunto(s)
Diseño Asistido por Computadora , Análisis de Falla de Equipo , Láseres de Estado Sólido , Diseño de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA