Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Intervalo de año de publicación
3.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;36(1): 125-129, Jan.-Feb. 2021. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1155789

RESUMEN

Abstract Although aortic valve replacement remains the gold standard treatment for aortic valve diseases like stenosis (AS) or insufficiency, new surgical methods have been developed with a focus in the reconstruction of the aortic valve rather than replacing it. The Ozaki procedure involves a tailored replacement of each individual valvular leaflet with glutaraldehyde-treated autologous pericardium and aims to reproduce the normal anatomy of the aortic valve. Cases of patients with unicuspid aortic valve treated with the Ozaki procedure are uncommon in the litrature and become even more rare when it comes to concomitant diseases like AS and ascending aorta aneurysm. We present the case of a 21-year-old, fit and asymptomatic male, with unicuspid aortic valve with severe stenosis and ascending aorta dilatation, surgically treated with tricuspidization of the aortic valve with glutaraldehyde-treated autologous pericardium and replacement of the ascending aorta with a straight synthetic graft. Postoperative studies showed a fully functional, neo-tailored tricuspid aortic valve with trivial regurgitation. The patient had an uncomplicated recovery, stayed in the intensive care unit for 2 days and was discharged on the 7th postoperative day.


Asunto(s)
Humanos , Masculino , Adulto , Adulto Joven , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas , Aorta , Válvula Aórtica/cirugía
4.
Braz J Cardiovasc Surg ; 36(1): 125-129, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33355794

RESUMEN

Although aortic valve replacement remains the gold standard treatment for aortic valve diseases like stenosis (AS) or insufficiency, new surgical methods have been developed with a focus in the reconstruction of the aortic valve rather than replacing it. The Ozaki procedure involves a tailored replacement of each individual valvular leaflet with glutaraldehyde-treated autologous pericardium and aims to reproduce the normal anatomy of the aortic valve. Cases of patients with unicuspid aortic valve treated with the Ozaki procedure are uncommon in the litrature and become even more rare when it comes to concomitant diseases like AS and ascending aorta aneurysm. We present the case of a 21-year-old, fit and asymptomatic male, with unicuspid aortic valve with severe stenosis and ascending aorta dilatation, surgically treated with tricuspidization of the aortic valve with glutaraldehyde-treated autologous pericardium and replacement of the ascending aorta with a straight synthetic graft. Postoperative studies showed a fully functional, neo-tailored tricuspid aortic valve with trivial regurgitation. The patient had an uncomplicated recovery, stayed in the intensive care unit for 2 days and was discharged on the 7th postoperative day.


Asunto(s)
Aneurisma de la Aorta , Enfermedades de las Válvulas Cardíacas , Adulto , Aorta , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/cirugía , Válvula Aórtica/cirugía , Humanos , Masculino , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA