Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ophthalmic Plast Reconstr Surg ; 29(6): 497-9, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24217481

RESUMEN

PURPOSE: To determine the effect of sub-Tenon injection on the length of optic nerve resected during enucleation. METHODS: Case-control laboratory study on 22 orbits of 11 unpreserved, fresh-frozen human cadavers. Each cadaver underwent a conventional enucleation technique on one side and an otherwise identical technique on the contralateral side that included sub-Tenon injection of 2.5 ml normal saline in each oblique quadrant. Resected optic nerve lengths were measured and compared using Student t tests. RESULTS: The mean optic nerve length was 15.2 mm (range, 5.0-21.0 mm) in the sub-Tenon injection group and 11.3 mm (range, 5.0-19.0 mm) in control group (p = 0.015). CONCLUSIONS: Sub-Tenon injection during enucleation allows for significantly longer optic nerve resection lengths in unpreserved, fresh-frozen human cadavers.


Asunto(s)
Anestésicos Locales/administración & dosificación , Enucleación del Ojo/métodos , Nervio Óptico/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Cadáver , Estudios de Casos y Controles , Enucleación del Ojo/instrumentación , Femenino , Humanos , Inyecciones/métodos , Cuidados Intraoperatorios/métodos , Masculino , Persona de Mediana Edad , Siembra Neoplásica , Nervio Óptico/efectos de los fármacos , Distribución Aleatoria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA