Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
4.
Curr Opin Nephrol Hypertens ; 31(5): 414-424, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35894275

RESUMEN

PURPOSE OF REVIEW: The known timing of contrast media exposure in patients identified as high-risk for contrast-associated acute kidney injury (CA-AKI) enables the use of strategies to prevent this complication of intravascular contrast media exposure. Although multiple preventive strategies have been proposed, periprocedural fluid administration remains as the primary preventive strategy. This is a critical review of the current evidence evaluating a variety of fluid administration strategies in CA-AKI. RECENT FINDINGS: Fluid administration strategies to prevent CA-AKI include comparisons of intravenous (i.v.) to no fluid administration, different fluid solutions, duration of fluid administration, oral hydration, left ventricular end diastolic-pressure guided fluid administration and forced diuresis techniques. SUMMARY: Despite an abundance of fluid administration trials, it is difficult to make definitive recommendations about preventive fluid administration strategies due to low scientific quality of published studies. The literature supports use of i.v. compared with no fluid administration, especially in high-risk patients undergoing intra-arterial contrast media exposure. Use of isotonic saline is recommended over 0.45% saline or isotonic sodium bicarbonate. Logistical considerations support shortened over longer i.v. fluid administration strategies, despite an absence of evidence of equivalent efficacy. Current literature does not support oral hydration for high-risk patients. The use of tailored fluid administration in heart failure patients and forced diuresis with matching fluid administration are promising new fluid administration strategies.


Asunto(s)
Lesión Renal Aguda , Medios de Contraste , Lesión Renal Aguda/inducido químicamente , Lesión Renal Aguda/prevención & control , Medios de Contraste/efectos adversos , Fluidoterapia/métodos , Humanos , Bicarbonato de Sodio
5.
Am J Kidney Dis ; 77(4): 517-528, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32861792

RESUMEN

Gadolinium-based contrast agents (GBCAs) improve the diagnostic capabilities of magnetic resonance imaging. Although initially believed to be without major adverse effects, GBCA use in patients with severe chronic kidney disease (CKD) was demonstrated to cause nephrogenic systemic fibrosis (NSF). Restrictive policies of GBCA use in CKD and selective use of GBCAs that bind free gadolinium more strongly have resulted in the virtual elimination of NSF cases. Contemporary studies of the use of GBCAs with high binding affinity for free gadolinium in severe CKD demonstrate an absence of NSF. Despite these observations and the limitations of contemporary studies, physicians remain concerned about GBCA use in severe CKD. Concerns of GBCA use in severe CKD are magnified by recent observations demonstrating gadolinium deposition in brain and a possible systemic syndrome attributed to GBCAs. Radiologic advances have resulted in several new imaging modalities that can be used in the severe CKD population and that do not require GBCA administration. In this article, we critically review GBCA use in patients with severe CKD and provide recommendations regarding GBCA use in this population.


Asunto(s)
Medios de Contraste/efectos adversos , Gadolinio/efectos adversos , Imagen por Resonancia Magnética/métodos , Insuficiencia Renal Crónica/diagnóstico por imagen , Encéfalo/efectos de los fármacos , Encéfalo/metabolismo , Ensayos Clínicos como Asunto/métodos , Medios de Contraste/metabolismo , Gadolinio/metabolismo , Tasa de Filtración Glomerular/efectos de los fármacos , Tasa de Filtración Glomerular/fisiología , Humanos , Imagen por Resonancia Magnética/normas , Dermopatía Fibrosante Nefrogénica/diagnóstico por imagen , Dermopatía Fibrosante Nefrogénica/metabolismo , Insuficiencia Renal Crónica/metabolismo , Factores de Riesgo
7.
J Vasc Interv Radiol ; 31(7): 1148-1155, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32534972

RESUMEN

PURPOSE: To compare clinical performance of 2 widely used symmetric-tip hemodialysis catheters. MATERIALS AND METHODS: Patients with end-stage renal disease initiating or resuming hemodialysis were randomized to receive an Arrow-Clark VectorFlow (n = 50) or Palindrome catheter (n = 50). Primary outcome was 90-d primary unassisted catheter patency. Secondary outcomes were Kt/V ([dialyzer urea clearance × total treatment time]/total volume of urea distribution), urea reduction ratio (URR), and effective blood flow (QB). RESULTS: Primary unassisted patency rates with the VectorFlow catheter at 30, 60, and 90 d were 95.5% ± 3.3, 87.2% ± 7.3, and 80.6% ± 9.8, respectively, compared with 89.1% ± 6.2, 79.4% ± 10.0, and 71.5% ± 12.6 with the Palindrome catheter (P = .20). Patients with VectorFlow catheters had a mean Kt/V of 1.5 at 30-, 60-, and 90-day time points, significantly higher than the mean Kt/V of 1.3 among those with Palindrome catheters (P = .0003). URRs were not significantly different between catheters. Catheter QB rates exceeded National Kidney Foundation-recommended thresholds of 300 mL/min at all time points for both catheters and were similar for both catheters (median, 373 mL/min). Catheter failure, ie, poor flow rate requiring guide-wire exchange or removal, within the 90-day primary outcome occurred in 3 VectorFlow subjects and 5 Palindrome subjects (P = .72). Infection rates were similar, with 0.98 infections per 1,000 catheter days for VectorFlow catheters compared with 2.62 per 1,000 catheter days for Palindrome catheters (P = .44). CONCLUSIONS: The 90-day primary patency rates of Palindrome and VectorFlow catheters were not significantly different, and both achieved sustained high QB through 90 day follow-up. However, dialysis adequacy based on Kt/V was consistently better with the VectorFlow catheter versus the Palindrome.


Asunto(s)
Cateterismo Venoso Central/instrumentación , Catéteres de Permanencia , Catéteres Venosos Centrales , Hemodinámica , Fallo Renal Crónico/terapia , Diálisis Renal/instrumentación , Anciano , Biomarcadores/sangre , Obstrucción del Catéter/etiología , Cateterismo Venoso Central/efectos adversos , Remoción de Dispositivos , Diseño de Equipo , Femenino , Humanos , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/fisiopatología , Masculino , Persona de Mediana Edad , Philadelphia , Estudios Prospectivos , Diálisis Renal/efectos adversos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Urea/sangre
8.
Interv Cardiol Clin ; 9(3): 279-292, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32471669

RESUMEN

History of contrast dates back to the 1890s, with the invention of the radiograph. Nephrotoxicity has been a main limitation in ideal contrast media (CM). High-osmolar contrast media no longer are in clinical use due to overwhelming evidence supporting greater nephrotoxicity with these CM compared with current CM. Contrast-induced nephropathy (CIN) remains a common cause of in-hospital acute kidney injury. The choice contrast agent is determined mainly by cost and institution practice. This review focuses on the history, chemical properties, and experimental and clinical studies on the various groups of CM and their role in CIN.


Asunto(s)
Lesión Renal Aguda/inducido químicamente , Medios de Contraste/efectos adversos , Enfermedades Renales/inducido químicamente , Lesión Renal Aguda/epidemiología , Medios de Contraste/historia , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/epidemiología , Historia del Siglo XIX , Humanos , Incidencia , Enfermedades Renales/epidemiología , Concentración Osmolar
10.
Am J Kidney Dis ; 75(1): 105-113, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31473019

RESUMEN

Contrast-induced nephropathy (CIN) has long been observed in both experimental and clinical studies. However, recent observational studies have questioned the prevalence and severity of CIN following intravenous contrast exposure. Initial studies of acute kidney injury following intravenous contrast were limited by the absence of control groups or contained control groups that did not adjust for additional acute kidney injury risk factors, including prevalent chronic kidney disease, as well as accepted prophylactic strategies. More contemporary use of propensity score-adjusted models have attempted to minimize the risk for selection bias, although bias cannot be completely eliminated without a prospective randomized trial. Based on existing data, we recommend the following CIN risk classification: patients with estimated glomerular filtration rates (eGFRs) ≥ 45mL/min/1.73m2 are at negligible risk for CIN, while patients with eGFRs<30mL/min/1.73m2 are at high risk for CIN. Patients with eGFRs between 30 and 44mL/min/1.73m2 are at an intermediate risk for CIN unless diabetes mellitus is present, which would further increase the risk. In all patients at any increased risk for CIN, the risk for CIN needs to be balanced by the risk of not performing an intravenous contrast-enhanced study.


Asunto(s)
Lesión Renal Aguda/inducido químicamente , Medios de Contraste/administración & dosificación , Lesión Renal Aguda/epidemiología , Administración Intravenosa/estadística & datos numéricos , Medios de Contraste/efectos adversos , Fluidoterapia , Humanos , Inyecciones Intraarteriales/estadística & datos numéricos , Mortalidad , Diálisis Renal , Insuficiencia Renal Crónica/epidemiología , Tomografía Computarizada por Rayos X
13.
Semin Dial ; 30(4): 290-304, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28382626

RESUMEN

Contrast exposure in a population with chronic kidney disease (CKD) requires additional consideration given the risk of contrast-induced nephropathy (CIN) after exposure to iodinated contrast as well as systemic injury with exposure to gadolinium-based contrast agents (GBCA). Strategies to avoid CIN, and manage patients after exposure, including extracorporeal removal of contrast media, may differ among an advanced CKD population as compared to a general population. There is strong evidence to support the use of isotonic volume expansion and the lowest dose of low-osmolar or iso-osmolar contrast media possible to decrease CIN. The current literature on other newer prophylactic strategies such as statins, remote ischemic preconditioning, discontinuation of renin angiotensin aldosterone system (RAAS) blockade, and RenalGuard is limited thus these strategies cannot currently be recommended as routine prophylaxis for CIN. The use of extracorporeal removal of contrast agents as prophylaxis to reduce CIN has been the subject of multiple studies; however, data do not support a beneficial effect in reduction in CIN. Immediate removal of contrast by dialysis in a maintenance dialysis population is also not recommended, unless an individual's cardiopulmonary status is dependent on strict volume management. In patients with reduced renal function, GCBA exposure increases the risk of NSF. In patients with AKI, CKD stage 3 or greater (eGFR <30 ml/minute/1.73 m2 ), or patients on dialysis, we do not recommend the use of GBCA and alternative imaging modalities should be considered. If patients absolutely need magnetic resonance imaging with GBCA, we recommend the use of the lowest dose possible of the newer macrocylic, ionic agents (gadoterate meglumine) as well as immediate postprocedural HD in patients already on HD or peritoneal dialysis or with stage 5 CKD and with a functioning dialysis access already in place.


Asunto(s)
Lesión Renal Aguda/inducido químicamente , Lesión Renal Aguda/prevención & control , Medios de Contraste/efectos adversos , Fallo Renal Crónico/terapia , Diálisis Renal , Humanos , Fallo Renal Crónico/diagnóstico por imagen , Radiografía
15.
Interv Cardiol Clin ; 3(3): 349-356, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28582219

RESUMEN

Contrast-induced nephropathy (CIN) is a common cause of acute kidney injury among hospitalized patients. High-osmolar contrast agents are associated with increased risk of CIN. Low-osmolar (LOCM) and iso-osmolar (IOCM) agents show no difference in the incidence of CIN, even among high-risk patients. This finding suggests that factors other than osmolality may play a role in the pathogenesis of CIN. The use of either LOCM or IOCM agents is recommended in high-risk patients.

16.
Thromb Res ; 131(3): 244-8, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23305841

RESUMEN

BACKGROUND: Heparin-induced thrombocytopenia (HIT) develops as a result of platelet (PLT) activation by anti-platelet factor 4 (PF4)/heparin complex antibodies. Despite repeated exposure to heparin, patients undergoing chronic intermittent hemodialysis (HD) rarely develop HIT. We investigated the possibility that HD decreases/removes PF4 from PLT surfaces and/or plasma, thereby disfavoring immune complex formation as a mechanism of protection against HIT. MATERIALS AND METHODS: We enrolled 20 patients undergoing chronic HD at the Penn Presbyterian Medical Center. Blood samples were drawn before, during and after treatment in the presence and absence of heparin. PF4, anti-PF4/heparin antibody, heparin, and P-selectin levels were measured. RESULTS: No patients demonstrated clinical symptoms of HIT. PLT surface PF4 levels decreased and plasma PF4 levels increased concurrently with the increase in plasma heparin concentration. In the absence of heparin, PLT surface and plasma PF4 levels were unchanged. Anti-PF4/heparin antibodies, which were non-functional by the serotonin release assay, were detectable in 8 patients. PLT surface P-selectin levels did not change during treatment. CONCLUSIONS: Removal of PLT surface and/or plasma PF4 as a mechanism of protection against HIT in patients undergoing HD is not supported by the results of our study, although the transient decrease in PLT surface PF4 in the presence of large amounts of heparin remains a candidate mechanism. The small sample size, single type of dialyzer membrane, and early sampling time points may have led to the inability to detect changes in PF4 levels. Future studies should explore other potential protective mechanisms.


Asunto(s)
Heparina/efectos adversos , Factor Plaquetario 4/sangre , Diálisis Renal/efectos adversos , Trombocitopenia/inducido químicamente , Anciano , Plaquetas/citología , Femenino , Heparina/metabolismo , Humanos , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/tratamiento farmacológico , Masculino , Membranas Artificiales , Persona de Mediana Edad , Selectina-P/metabolismo , Activación Plaquetaria/efectos de los fármacos , Factor Plaquetario 4/inmunología , Serotonina/metabolismo , Propiedades de Superficie , Trombocitopenia/prevención & control
17.
Clin J Am Soc Nephrol ; 8(3): 484-96, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23065497

RESUMEN

Implantable left ventricular assist devices (LVADs) are increasingly being used as a bridge to transplantation or as destination therapy in patients with end stage heart failure refractory to conventional medical therapy. A significant number of these patients have associated renal dysfunction before LVAD implantation, which may improve after LVAD placement due to enhanced perfusion. Other patients develop AKI after implantation. LVAD recipients who develop AKI requiring renal replacement therapy in the hospital or who ultimately require long-term outpatient hemodialysis therapy present management challenges with respect to hemodynamics, volume, and dialysis access. This review discusses the mechanics of a continuous-flow LVAD (the HeartMate II), the effects of continuous blood flow on the kidney, renal outcomes of patients after LVAD implantation, dialysis modality selection, vascular access, hemodynamic monitoring during the dialytic procedure, and other issues relevant to caring for these patients.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Hemodinámica , Riñón/fisiopatología , Insuficiencia Renal/complicaciones , Función Ventricular Izquierda , Lesión Renal Aguda/etiología , Lesión Renal Aguda/fisiopatología , Lesión Renal Aguda/terapia , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Corazón Auxiliar/efectos adversos , Humanos , Diseño de Prótesis , Recuperación de la Función , Diálisis Renal , Insuficiencia Renal/mortalidad , Insuficiencia Renal/fisiopatología , Insuficiencia Renal/terapia , Resultado del Tratamiento
18.
J Vasc Interv Radiol ; 20(12): 1578-81; quiz 1582, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19944983

RESUMEN

PURPOSE: Nontunneled hemodialysis catheters (NTDCs) are widely used for initial hemodialysis access in new-onset renal failure. The National Kidney Foundation recommends NTDC use for hemodialysis duration of less than 1 week in acute kidney injury because of the increased infection risk compared with tunneled hemodialysis catheters (TDCs) with longer use. The present study was performed to determine whether primary placement of TDCs in this setting is more appropriate, and whether there are predictors of recovery of renal function in less than 1 week. MATERIALS AND METHODS: In the authors' practice, patients referred to the interventional radiology unit in whom no contraindications exist receive a TDC; 76 patients who received a primary TDC for acute kidney injury and who eventually recovered renal function were retrospectively reviewed herein. Causes of renal failure, various renal function parameters, and demographics were collected, as were TDC dwell times, in an effort to determine predictors of recovery and/or extended duration of use. RESULTS: Mean TDC dwell time in patients who eventually recovered from acute kidney injury was 34 days; only 15 of 76 (20%) recovered within 1 week. At TDC placement, there were no significant differences between patients who recovered in less than (vs greater than) 1 week. CONCLUSIONS: The present results support primary placement of TDCs in patients with acute kidney injury who require hemodialysis and in whom no contraindications exist, as no predictors of recovery of renal function in less than 1 week were identified.


Asunto(s)
Catéteres de Permanencia , Enfermedades Renales/terapia , Riñón/lesiones , Diálisis Renal/instrumentación , Enfermedad Aguda , Infecciones Relacionadas con Catéteres/etiología , Catéteres de Permanencia/efectos adversos , Diseño de Equipo , Medicina Basada en la Evidencia , Femenino , Humanos , Riñón/fisiopatología , Enfermedades Renales/fisiopatología , Pruebas de Función Renal , Masculino , Persona de Mediana Edad , Selección de Paciente , Guías de Práctica Clínica como Asunto , Recuperación de la Función , Diálisis Renal/efectos adversos , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
19.
Am Heart J ; 158(5): 822-828.e3, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19853704

RESUMEN

BACKGROUND: The choice of radiographic contrast media for use in patients at increased risk of contrast-induced nephropathy (CIN) is of ongoing interest. METHODS: The current study is a prospective, multicenter, randomized, double-blind design comparing the renal effects of the non-ionic, iso-osmolal agent, iodixanol, versus the non-ionic, low-osmolal agent, iopamidol, in 526 subjects with impaired baseline renal function (chronic kidney disease) and diabetes mellitus undergoing diagnostic and/or therapeutic coronary angiographic procedures. The co-primary end points were the peak increase in serum creatinine (SCr) and the incidence of CIN (increase > or =0.5 mg/dL) in SCr from baseline within 3 days of receiving contrast media. RESULTS: In 418 evaluable subjects with complete postcontrast media SCr data, the median peak increase in SCr in the iodixanol arm was 0.10 mg/dL, whereas in the iopamidol arm, the median peak increase was 0.09 mg/dL (P = .13). The overall CIN incidence was 10.5% (11.2% % in the iodixanol arm and 9.8% in the iopamidol arm, P = .7). The volume of contrast media, volume of saline administered, frequency of coronary interventional procedures, and severity of baseline kidney disease and of diabetes mellitus were similar between treatments. CONCLUSIONS: In the present study, the overall rate of CIN in patients with chronic kidney disease and DM undergoing coronary angiographic procedures was 10.5%. There was no significant difference between iodixanol and iopamidol in either peak increase in SCr or risk of CIN.


Asunto(s)
Medios de Contraste/toxicidad , Angiografía Coronaria/efectos adversos , Yopamidol/toxicidad , Ácidos Triyodobenzoicos/toxicidad , Anciano , Creatinina/sangre , Nefropatías Diabéticas/sangre , Método Doble Ciego , Femenino , Humanos , Fallo Renal Crónico/sangre , Masculino
20.
Am Heart J ; 156(4): 776-82, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18946896

RESUMEN

BACKGROUND: Iso-osmolar contrast medium iodixanol has been reported to be less nephrotoxic than selected low-osmolar contrast media (LOCM) in chronic kidney disease (CKD) patients with diabetes mellitus. This study compared the nephrotoxicity of iodixanol and the LOCM ioversol in CKD patients undergoing coronary angiography. METHODS: This is a prospective double-blind trial in 337 patients with stable CKD who were randomly assigned to receive the iso-osmolar contrast medium iodixanol or the LOCM ioversol. The co-primary end points were the mean peak percentage change (MPPC) in baseline serum creatinine and the incidence of contrast-induced nephropathy (rise of > 0.5 mg/dL in baseline serum creatinine within 72 hours postcontrast) for the 2 contrast media in the 72-hour period after contrast administration. Prespecified analyses included stratification on diabetic state and the use of N-acetylcysteine. RESULTS: In the 299 patients with complete post-contrast media creatinine data, the incidence of contrast-induced nephropathy was 21.8% in the iodixanol subjects and 23.8% in the ioversol subjects (P = .78). For all patients, the MPPC was 14.7% with iodixanol and 20.0% with ioversol (P = .06), whereas in the subset of diabetic patients, this value was significantly lower in the iodixanol (12.9%) compared with the ioversol subjects (22.4%, P = .01). CONCLUSIONS: Overall, the nephrotoxicity associated with iodixanol was not significantly different from that observed with ioversol in CKD patients undergoing coronary angiography, although in diabetic patients, MPPC was significantly lower in the iodixanol group.


Asunto(s)
Medios de Contraste/efectos adversos , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Angiopatías Diabéticas/diagnóstico por imagen , Nefropatías Diabéticas/fisiopatología , Riñón/efectos de los fármacos , Insuficiencia Renal Crónica/fisiopatología , Ácidos Triyodobenzoicos/efectos adversos , Anciano , Anciano de 80 o más Años , Enfermedad Coronaria/epidemiología , Creatinina/sangre , Angiopatías Diabéticas/epidemiología , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Insuficiencia Renal Crónica/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA