Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 169
Filtrar
1.
Clin Res Cardiol ; 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38695900

RESUMEN

BACKGROUND: Permanent pacemaker implantation (PMI) is associated with increased morbidity after transcatheter aortic valve replacement (TAVR). Cardiac resynchronization-therapy (CRT) is recommended for patients if left ventricular ejection fraction (LVEF) is ≤ 40% and ventricular pacing is expected in favor to sole right ventricular (RV) pacing. Meanwhile, LVEF may recover after TAVR in patients with aortic valve disease and the benefit of CRT is unknown. OBJECTIVE: To analyze the impact of CRT implantation as compared to RV pacing after TAVR. METHODS AND RESULTS: Between 2012 and 2022, 4385 patients (53.1% female, mean age 81 ± 6 years) without prior PMI undergoing TAVR were retrospectively identified in our institutional registry. After stratification of patients in LVEF ≤ 40%, 41-49% and ≥ 50%, Kaplan-Meier analysis revealed significantly different survival rates in each subgroup at 5 years (37.0% vs. 43.5% vs. 55.1%; P ≤ 0.021). At multivariate regression, LVEF and new PMI after TAVR were not relevant for survival. A total of 105 patients with LVEF ≤ 40% received PMI after TAVR (86 patients with RV pacing and 19 with CRT). At 5 years, all-cause mortality was significantly lower in patients with CRT-device as compared to patients without CRT-device (Kaplan Meier estimate of 21.1% vs. 48.8%; HR 0.48, CI 0.204 - 1.128; log rank p = 0.045). In multivariate analysis CRT remained a significant factor for 5-year survival in these patients (HR 0.3, CI 0.095-0.951, p = 0.041). CONCLUSION: In patients undergoing TAVR, PMI did not influence 5-year survival. In patients with LVEF ≤ 40%, CRT-device implantation was associated with improved survival compared to non-CRT-device implantation.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38804621

RESUMEN

BACKGROUND: The latest generation ultrathin Supraflex Cruz (Sahajanand Medical Technologies Limited, Surat, India) sirolimus-eluting stent (SES) has shown early healing properties and represents an attractive percutaneous coronary intervention (PCI) device in a high bleeding risk (HBR) population. The aim of this Cruz HBR registry was to assess safety and efficacy of the Supraflex Cruz SES in a large cohort of all-comer patients, of whom about one third were patients at HBR. METHODS: Patients undergoing PCI were enrolled in this prospective, multi-centre, open label registry and stratified into non-HBR and HBR groups. The primary endpoint was a device-oriented composite endpoint (DOCE), a composite of cardiovascular death, myocardial infarction not clearly attributable to a non-target vessel and clinically driven target lesion revascularization within 12 months after PCI. The predefined aims were to show non-inferiority of the non-HBR group to the Supraflex arm of the TALENT Trial, and of the HBR group to polymer-free biolimus-coated stent arm of LEADERS FREE Trial. RESULTS: A total of 1203 patients were enrolled across 26 European centers, including a significant proportion (38.7%; N.=466) of HBR patients. A total of 1745 lesions were treated in 1203 patients and 2235 stents were implanted. The DOCE occurred within the total cohort in 5.8% of patients with a significant difference between HBR patients and non-HBR patients (8.1% vs. 4.4%; P<0.001). All-cause mortality at 12 months was significantly (P<0.0001) different among HBR (9.0%) and non-HBR patients (1.7%), respectively. At 12 months, the overall incidence of definite and probable stent thrombosis was 1.0%. Major bleeding occurred in 5.9% patients of the HBR group. These results met the non-inferiority criteria with respect to the TALENT trial for the non-HBR group (P<0.0001), and the LEADERS FREE trial for the HBR group (P<0.0001). CONCLUSIONS: The Cruz HBR registry confirms that PCI with the Supraflex Cruz SES is associated with a favorable clinical outcome in an all-comer population, including complex patients with HBR.

3.
N Engl J Med ; 390(17): 1572-1583, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38588025

RESUMEN

BACKGROUND: Among low-risk patients with severe, symptomatic aortic stenosis who are eligible for both transcatheter aortic-valve implantation (TAVI) and surgical aortic-valve replacement (SAVR), data are lacking on the appropriate treatment strategy in routine clinical practice. METHODS: In this randomized noninferiority trial conducted at 38 sites in Germany, we assigned patients with severe aortic stenosis who were at low or intermediate surgical risk to undergo either TAVI or SAVR. Percutaneous- and surgical-valve prostheses were selected according to operator discretion. The primary outcome was a composite of death from any cause or fatal or nonfatal stroke at 1 year. RESULTS: A total of 1414 patients underwent randomization (701 to the TAVI group and 713 to the SAVR group). The mean (±SD) age of the patients was 74±4 years; 57% were men, and the median Society of Thoracic Surgeons risk score was 1.8% (low surgical risk). The Kaplan-Meier estimate of the primary outcome at 1 year was 5.4% in the TAVI group and 10.0% in the SAVR group (hazard ratio for death or stroke, 0.53; 95% confidence interval [CI], 0.35 to 0.79; P<0.001 for noninferiority). The incidence of death from any cause was 2.6% in the TAVI group and 6.2% in the SAVR group (hazard ratio, 0.43; 95% CI, 0.24 to 0.73); the incidence of stroke was 2.9% and 4.7%, respectively (hazard ratio, 0.61; 95% CI, 0.35 to 1.06). Procedural complications occurred in 1.5% and 1.0% of patients in the TAVI and SAVR groups, respectively. CONCLUSIONS: Among patients with severe aortic stenosis at low or intermediate surgical risk, TAVI was noninferior to SAVR with respect to death from any cause or stroke at 1 year. (Funded by the German Center for Cardiovascular Research and the German Heart Foundation; DEDICATE-DZHK6 ClinicalTrials.gov number, NCT03112980.).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Estimación de Kaplan-Meier , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Factores de Riesgo , Alemania
4.
Eur J Heart Fail ; 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38571456

RESUMEN

AIMS: While invasively determined congestion holds mechanistic and prognostic significance in acute heart failure (HF), its role in patients with tricuspid regurgitation (TR)-related right- heart failure (HF) undergoing transcatheter tricuspid valve intervention (TTVI) is less well established. A comprehensive understanding of congestion patterns might aid in procedural planning, risk stratification, and the identification of patients who may benefit from adjunctive therapies before undergoing TTVI. The aim of this study was to investigate the role of congestion patterns in patients with severe TR and its implications for TTVI. METHODS AND RESULTS: Within a multicentre, international TTVI registry, 813 patients underwent right heart catheterization (RHC) prior to TTVI and were followed up to 24 months. The median age was 80 (interquartile range 76-83) years and 54% were women. Both mean right atrial pressure (RAP) and pulmonary capillary wedge pressure (PCWP) were associated with 2-year mortality on Cox regression analyses with Youden index-derived cut-offs of 17 mmHg and 19 mmHg, respectively (p < 0.01 for all). However, RAP emerged as an independent predictor of outcomes following multivariable adjustments. Pre-interventionally, 42% of patients were classified as euvolaemic (RAP <17 mmHg, PCWP <19 mmHg), 23% as having left-sided congestion (RAP <17 mmHg, PCWP ≥19 mmHg), 8% as right-sided congestion (RAP ≥17 mmHg, PCWP <19 mmHg), and 27% as bilateral congestion (RAP ≥17 mmHg, PCWP ≥19 mmHg). Patients with right-sided or bilateral congestion had the lowest procedural success rates and shortest survival times. Congestion patterns allowed for discerning specific patient's physiology and specifying prognostic implications of right ventricular to pulmonary artery coupling surrogates. CONCLUSION: In this large cohort of invasively characterized patients undergoing TTVI, congestion patterns involving right-sided congestion were associated with low procedural success and higher mortality rates after TTVI. Whether pre-interventional reduction of right-sided congestion can improve outcomes after TTVI should be established in dedicated studies.

5.
JACC Cardiovasc Interv ; 17(6): 742-752, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38538170

RESUMEN

BACKGROUND: Coronary obstruction (CO) is a potentially life-threatening complication of transcatheter aortic valve replacement (TAVR). Chimney stenting or leaflet laceration with transcatheter electrosurgery (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) are 2 techniques developed to prevent CO. OBJECTIVES: The aim of the present study was to compare periprocedural and 1-year outcomes of chimney and BASILICA in TAVR patients at high risk of CO. METHODS: This multicenter observational registry enrolled consecutive TAVR patients at high risk of CO, undergoing either preventive chimney stenting or BASILICA. Clinical success was defined as successful performance of the chimney or BASILICA technique without clinically relevant ostial CO. The primary endpoint was major adverse cardiovascular events, a composite of death, myocardial infarction, stroke, or unplanned target lesion coronary revascularization at 1 year. RESULTS: A total of 168 patients were included: 71 (42.3%) received chimney stenting, and 97 (57.7%) underwent BASILICA. Patients undergoing BASILICA had higher preprocedural risk of CO, as indicated by lower sinotubular junction height (18.2 ± 4.8 mm vs 14.8 ± 3.4 mm; P < 0.001) and diameter (28.2 ± 4.5 vs 26.8 ± 3.4; P = 0.029). Rates of periprocedural complications were similar between the 2 groups. Clinical success was 97.2% and 96.9% in chimney and BASILICA, respectively (P = 0.92). At 1-year follow-up, the cumulative incidence of major adverse cardiovascular events was 18.7% (95% CI: 11%-30.6%) in the chimney group and 19.9% (95% CI: 12.1%-31.5%) in the BASILICA group (log-rank P = 0.848), whereas chimney was associated with a numerically higher cardiovascular mortality than BASILICA (6.7% vs 1.3%; log-rank P = 0.168). CONCLUSIONS: Chimney stenting and BASILICA effectively prevent TAVR-induced acute CO. Both techniques seem to have comparable acceptable periprocedural and 1-year outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Oclusión Coronaria , Prótesis Valvulares Cardíacas , Laceraciones , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Laceraciones/complicaciones , Laceraciones/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Oclusión Coronaria/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Diseño de Prótesis
6.
Clin Res Cardiol ; 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38436739

RESUMEN

BACKGROUND: In patients not suitable for transfemoral transcatheter aortic valve implantation (TAVI), several access strategies can be chosen. AIM: To evaluate the use and patient outcomes of transaxillary (TAx), transapical (TA), and transaortic (TAo) as alternative access for TAVI in Germany; to further evaluate surgical cutdown vs. percutaneous TAx access. METHODS: All patients entered the German Aortic Valve Registry (GARY) between 2011 and 2019 who underwent non-transfemoral TAVI were included in this analysis. Patients with TA, TAo, or TAx TAVI were compared using a weighted propensity score model. Furthermore, a subgroup analysis was performed for TAx regarding the percutaneous or surgical cutdown approach. RESULTS: Overall, 9686 patients received a non-transfemoral access. A total of 8918 patients (92.1%) underwent TA, 398 (4.1%) TAo, and 370 (3.8%) TAx approaches. Within the TAx subgroup, 141 patients (38.1%) received subclavian cutdown, while 200 (54.1%) underwent a percutaneous approach. The TA patients had a significantly lower 30-day survival than TAx patients (TA 90.92% vs. TAx 95.59%, p = 0.006; TAo 92.22% vs. TAx 95.59%, p = 0.102). Comparing percutaneous and cutdown TAx approaches, no significant differences were seen. However, more vascular complications occurred (TA 1.8%, TAo 2.4%, TAx 12.2%; p < .001), and the hospital length of stay was shorter (TA 12.9 days, TAo 14.1 days, TAx 12 days; p < .001) after TAx access. CONCLUSION: It may be reasonable to consider TAx access first in patients not suitable for TF-TAVI, because the 30-day survival was higher compared with TA access and the 1-year survival was higher compared with TAo access. It remains important for the heart teams to offer alternative access modalities for patients not amenable to the standard TF-TAVI approaches.

7.
Inn Med (Heidelb) ; 65(5): 425-430, 2024 May.
Artículo en Alemán | MEDLINE | ID: mdl-38436690

RESUMEN

Currently, there is no specific medication approved for the treatment of valvular heart disease per se. Except for secondary mitral valve insufficiency and tricuspid valve insufficiency in pulmonary hypertension, drug therapy for higher-grade valvular heart disease is limited to diuretic therapy for symptom control. Conservative therapy for comorbidities and potential heart failure can be beneficial regardless of the specific valve lesion. In cases of aortic valve stenosis or insufficiency, controlling arterial hypertension is important. Patients with mitral valve stenosis benefit from rhythm and rate control. Diuretics can help reduce regurgitant volume in patients with primary mitral valve insufficiency and tricuspid valve insufficiency. In addition to drug therapy, maintaining functional capacity is crucial for the outcome of patients. Therefore, it is recommended to engage in active physical activity whenever possible, despite the presence of valvular heart disease.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Humanos , Enfermedades de las Válvulas Cardíacas/tratamiento farmacológico , Adulto , Tratamiento Conservador/métodos , Diuréticos/uso terapéutico
8.
Inn Med (Heidelb) ; 65(5): 495-502, 2024 May.
Artículo en Alemán | MEDLINE | ID: mdl-38517528

RESUMEN

BACKGROUND: Clinical management of patients with angina and no obstructive coronary artery disease (ANOCA) is still challenging. This scenario affects up to 50% of patients undergoing diagnostic coronary angiography due to suspected coronary artery disease. Many patients report a long and debilitating history before adequate diagnostics and management are initiated. OBJECTIVES: This article describes the current recommendations for diagnostic assessments and treatment in patients with ANOCA. Focus is placed on invasive diagnostics in the catheter laboratory, pharmacological/interventional treatment as well as the patient journey. RESULTS: In patients with ANOCA, the current European Society of Cardiology (ESC) guidelines suggest that invasive assessments using acetylcholine and adenosine for the diagnosis of an underlying coronary vasomotor disorder should be considered. Acetylcholine is used to diagnose coronary spasm, whereas adenosine is used in conjunction with a wire-based assessment for the measurement of coronary flow reserve and microvascular resistance. The invasive assessments allow the determination of what are referred to as endotypes (coronary spasm, impaired coronary flow reserve, enhanced microvascular resistance or a combination thereof). Establishing a diagnosis is helpful to: (a) initiate targeted treatment to improve quality of life, (b) reassure the patient that a cardiac cause is found and (c) to assess individual prognosis. CONCLUSIONS: Currently, patients with ANOCA are often not adequately managed. Referral to specialised centres is recommended to prevent long and debilitating patient histories until expertise in diagnosis and treatment becomes more widespread.


Asunto(s)
Angina de Pecho , Angiografía Coronaria , Humanos , Angiografía Coronaria/métodos , Angina de Pecho/terapia , Angina de Pecho/diagnóstico por imagen , Angina de Pecho/diagnóstico , Vasoespasmo Coronario/diagnóstico por imagen , Vasoespasmo Coronario/diagnóstico , Vasoespasmo Coronario/terapia , Acetilcolina , Adenosina/administración & dosificación
9.
Int J Cardiol ; 406: 131996, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38555056

RESUMEN

OBJECTIVE: Management of patients with severe aortic stenosis (AS) may differ according to the patient sex. This study aimed to describe patterns of aortic valve replacement (AVR) for severe AS across Europe, including stratification by sex. METHODS: Procedure volume data for surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) for six years (2015-2020) were extracted from national databases for Austria, Czech Republic, Denmark, England, Finland, France, Germany, Norway, Poland, Spain, Sweden, and Switzerland and stratified by sex. Patients per million population (PPM) undergoing AVR per year were calculated using population estimates from Eurostat. RESULTS: Between 2015 and 2019, AVR procedures grew at an average annual rate of 3.9%. In 2020, the average total PPM undergoing AVR across all countries was 339, with 51% of procedures being TAVI and 49% SAVR. AVR PPM varied widely between countries, with the highest and lowest in Germany and Poland, respectively. The average total PPM was higher for men than women (423 vs. 258), but a higher proportion of women (62%) than men (44%) received TAVI. The proportion of TAVI among total AVR procedures increased with age, with an overall average of 96% of men and 98% of women aged ≥85 years receiving TAVI; however, adoption of TAVI varied by country. CONCLUSIONS: The analysis of temporal trends in the adoption of TAVI vs. SAVR across Europe showed significant variations. Despite the higher use of TAVI vs. SAVR in women, overall rates of AV intervention in women were lower compared to men.


Asunto(s)
Estenosis de la Válvula Aórtica , Humanos , Femenino , Masculino , Europa (Continente)/epidemiología , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/epidemiología , Anciano de 80 o más Años , Factores Sexuales , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Válvula Aórtica/cirugía , Persona de Mediana Edad
10.
JACC Cardiovasc Interv ; 17(5): 648-661, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38385922

RESUMEN

BACKGROUND: Early studies of the Tendyne transcatheter mitral valve replacement (TMVR) showed promising results in a small selective cohort. OBJECTIVES: The authors present 1-year data from the currently largest commercial, real-world cohort originating from the investigator-initiated TENDER (Tendyne European Experience) registry. METHODS: All patients from the TENDER registry eligible for 1-year follow-up were included. The primary safety endpoint was 1-year cardiovascular mortality. Primary performance endpoint was reduction of mitral regurgitation (MR) up to 1 year. RESULTS: Among 195 eligible patients undergoing TMVR (median age 77 years [Q1-Q3: 71-81 years], 60% men, median Society of Thoracic Surgeons Predicted Risk of Mortality 5.6% [Q1-Q3: 3.6%-8.9%], 81% in NYHA functional class III or IV, 94% with MR 3+/4+), 31% had "real-world" indications for TMVR (severe mitral annular calcification, prior mitral valve treatment, or others) outside of the instructions for use. The technical success rate was 95%. The cardiovascular mortality rate was 7% at 30 day and 17% at 1 year (all-cause mortality rates were 9% and 29%, respectively). Reintervention or surgery following discharge was 4%, while rates of heart failure hospitalization reduced from 68% in the preceding year to 25% during 1-year follow-up. Durable MR reduction to ≤1+ was achieved in 98% of patients, and at 1 year, 83% were in NYHA functional class I or II. There was no difference in survival and major adverse events between on-label use and "real-world" indications up to 1 year. CONCLUSIONS: This large, real-world, observational registry reports high technical success, durable and complete MR elimination, significant clinical benefits, and a 1-year cardiovascular mortality rate of 17% after Tendyne TMVR. Outcomes were comparable between on-label use and "real-world" indications, offering a safe and efficacious treatment option for patients without alternative treatments. (Tendyne European Experience Registry [TENDER]; NCT04898335).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Anciano , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco/métodos , Sistema de Registros
11.
Front Cardiovasc Med ; 11: 1337941, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38404721

RESUMEN

Background: Randomized evidence suggested improved outcomes in fractional flow reserve (FFR) guidance of coronary revascularization compared to medical therapy in well-defined patient cohorts. However, the impact of FFR-guided revascularization on long-term outcomes of unselected patients with chronic or acute coronary syndromes (ACS) is unknown. Aims: The FLORIDA (Fractional FLOw Reserve In cardiovascular DiseAses) study sought to investigate outcomes of FFR-guided vs. angiography-guided treatment strategies in a large, real-world cohort. Methods: This study included patients enrolled into the German InGef Research Database. Patients undergoing coronary angiography between January 2014 and December 2015 were included in the analysis. Eligible patients had at least one inpatient coronary angiogram for suspected coronary artery disease between January 2014 and December 2015. Patients were stratified into FFR arm if a coronary angiography with adjunctive FFR measurement was performed, otherwise into the angiography-only arm. Matching was applied to ensure a balanced distribution of baseline characteristics in the study cohort. Patients were followed for 3 years after index date and primary endpoint was all-cause mortality. Results: In the matched population, mortality at 3 years was 9.6% in the FFR-assessed group and 12.6% in the angiography-only group (p = 0.002), corresponding to a 24% relative risk reduction with use of FFR. This effect was most pronounced in patients in whom revascularization was deferred based on FFR (8.7% vs. 12.3%, p = 0.04) and in high-risk subgroups including patients aged ≥75 years (14.9% vs. 20.1%, p < 0.01) and those presenting with ACS (10.2% vs. 14.0%, p = 0.04). Conclusions: FFR-based revascularization strategy was associated with reduced mortality at 3 years. These findings further support the use of FFR in everyday clinical practice.

12.
Clin Res Cardiol ; 113(2): 336-352, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38170247

RESUMEN

BACKGROUND AND AIMS: Prosthetic valve endocarditis (PVE) is the prognostically most unfavourable complication after aortic valve replacement. This study aims to contribute to a better understanding of the different pathological and therapeutical aspects between PVE following surgical (SAVR) and transcatheter aortic valve replacement (TAVI). METHODS: All patients who had undergone primary isolated SAVR (n = 3447) or TAVI (n = 2269) at our Centre between 01/2012 and 12/2018 were analysed. Diagnosis of PVE was based on Duke criteria modified in 2015. Incidence, risk factors, pathogens, impact of complications or therapy on mortality were analysed and compared between SAVR- and TAVI-PVE. RESULTS: PVE incidence did not differ significantly after SAVR with 4.9/100 patient-years and TAVI with 2.4/100 patient-years (p = 0.49), although TAVI patients were older (mean 80 vs. 67 years) and had more comorbidities (STS score mean 5.9 vs. 1.6) (p < 0.001). TAVI prostheses with polymer showed a 4.3-fold higher risk to develop PVE than without polymer (HR 4.3; p = 0.004). Most common pathogens were staphylococci and enterococci (p > 0.05). Propensity-score matching analysis showed that the type of aortic valve replacement had no effect on the development of post-procedural PVE (p = 0.997). One-year survival was higher in TAVI-PVE patients treated with antibiotics only compared to additional surgical therapy (90.9% vs. 33.3%; p = 0.005). In SAVR-PVE patients, both therapies were comparable in terms of survival (p = 0.861). However, SAVR-PVE patients who were not operated, despite ESC-guideline recommendation, had significantly poorer one-year survival (p = 0.004). CONCLUSION: TAVI patients did not have a significantly higher risk to develop PVE. Our data suggest that TAVI-PVE patients in contrast to SAVR-PVE patients can more often be treated with antibiotics only, presumably due to the lack of a polymeric suture ring.


Asunto(s)
Estenosis de la Válvula Aórtica , Endocarditis Bacteriana , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Endocarditis/epidemiología , Factores de Riesgo , Instrumentos Quirúrgicos , Antibacterianos/uso terapéutico , Polímeros , Catéteres/efectos adversos , Resultado del Tratamiento
13.
J Clin Med ; 13(2)2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38256618

RESUMEN

Both the MitraClip and PASCAL systems offer transcatheter edge-to-edge repair (TEER) solutions for mitral regurgitation. Evidence indicates a lower technical success rate for TEER in complex degenerative mitral regurgitation (DMR) cases. We conducted a retrospective analysis of patients who underwent transcatheter edge-to-edge therapy for primary mitral regurgitation with advanced anatomy, defined as mitral regurgitation effective regurgitant orifice area (MR-EROA) ≥0.40 cm2 or large flail gap (≥5 mm) or width (≥7 mm) or Barlow's disease, that completed follow-up after 1 year. Our criteria were met by 27 patients treated with PASCAL and 18 with MitraClip. All patients exhibited a significant, equivalent short-term reduction in MR-EROA, mitral regurgitation vena contracta diameter (MR-VCD), regurgitant volume, and clinical status. At 1 year follow-up, reductions in MR-VCD, regurgitant volume, and MR-EROA remained significant for both groups without significant differences between groups. MR-Grade ≤ 1+ was achieved in 18 (66.7%) and 10 (55.6%) patients, respectively. At follow-up, no difference in hospitalization for cardiac decompensation was observed. Overall death was similar in both groups. Our study suggests that both the PASCAL and MitraClip systems significantly reduce mitral regurgitation even in advanced degenerative diseases. Within our limited data, we found no evidence of inferior performance of the PASCAL system.

14.
Eur Heart J Case Rep ; 8(1): ytad640, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38213867

RESUMEN

Background: In more than 90%, transcatheter aortic valve implantation (TAVI) is performed via transfemoral access. Alternative access routes are necessary for patients with unfavourable femoral arteries. Case summary: We report of a 68-year-old female with symptomatic severe aortic stenosis in whom surgical aortic valve replacement was prohibited due to her severe co-morbidities. Both femoral arteries and both subclavian arteries were unsuitable for TAVI access. Surgical aortic valve replacement and transapical TAVI were deferred due to extremely high operative risk and very low originating left coronary artery of 7 mm from the annulus. Hence, we decided to implant a self-expanding TAVI device with a low risk of coronary obstruction (Acurate Neo 2 prosthesis) via transaortic approach, which to our knowledge is the first case worldwide. Conclusion: The present case demonstrates the feasibility of implanting the Acurate Neo 2 system via transaortic approach when certain key points are respected. Transaortic TAVI with the Acurate Neo 2 offers a minimally invasive treatment of high operative risk patients with low originating coronary arteries.

15.
Int J Cardiol ; 400: 131792, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38244892

RESUMEN

BACKGROUND: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. AIM: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. METHODOLOGY: This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. RESULTS: Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. CONCLUSION: Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/métodos , Calcio , Resultado del Tratamiento , Estudios Retrospectivos , Diseño de Prótesis
17.
Clin Res Cardiol ; 113(1): 38-47, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37115228

RESUMEN

BACKGROUND: New-generation self-expanding transcatheter aortic heart valves (THV) were designed to overcome technical constraints of their preceding generations. We sought to compare the efficacy and safety of the self-expanding ACURATE neo2 (Neo2) versus Evolut PRO (PRO) devices. METHODS: Seven hundred nine patients undergoing transfemoral transcatheter aortic valve implantation (TAVI) with either Neo2 (n = 496) or PRO (n = 213) were included. Propensity score matching (PSM) was performed to account for differences in baseline characteristics. In-hospital and 30-day clinical outcomes were evaluated according to Valve Academic Research Consortium-3 criteria. RESULTS: Baseline characteristics were comparable between both groups after PSM (Neo2: n = 155, Evolut Pro: n = 155). Technical success rates were high in both groups (Neo2: 94.8% vs PRO: 97.4%; p = 0.239). Need for permanent pacemaker implantation was less frequent with Neo2 compared with PRO (7.5% vs 20.6%; p = 0.002), whereas major vascular complications were more frequent with Neo2 (Neo2: 11.6% vs PRO: 4.5%; p = 0.022). Intended valve performance at discharge was high in both groups without relevant differences among groups (Neo2: 97.4% vs. 95.3%; p = 0.328). CONCLUSIONS: Short-term outcomes after TAVI using latest-generation self-expanding THV were excellent, with overall low rates of adverse events. However, Neo2 was associated with lower pacemaker rates and reduced the prevalence of moderate-severe paravalvular leakage. Transprosthetic gradients after TAVI were higher with Neo2 compared with PRO.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento
18.
Clin Res Cardiol ; 113(1): 107-115, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37524838

RESUMEN

BACKGROUND: Many patients in need for transcatheter aortic valve implantation (TAVI) present with an aortic annulus size larger than recommended by the manufacturer's instructions for use (IFU). AIMS: To investigate procedural and short-term safety and efficacy of TAVI in patients with extra-large annuli (ELA). METHODS: 30-day clinical outcome and valve performance as defined by VARC 3 of 144 patients with an aortic annulus size exceeding the permitted range were compared to a propensity-score matched control cohort of patients with an aortic annulus size consistent with the IFU. RESULTS: Area and perimeter was 730.4 ± 53.9 mm2 and 96.7 ± 6.5 mm in the ELA group. Technical (96.5% vs. 94.4%) and device success (82.3% vs. 84.5%) were comparable in patients with ELA (annulus area 730.4 ± 53.9 mm2) and matched controls (annulus area 586.0 ± 48.2 mm2). There was no significant difference in 30-day mortality rate, major intraprocedural complications, type 3 or 4 bleedings, major vascular complications, or stroke. Moderate paravalvular leakage (PVL) occurred more frequent in the ELA group (8.9% vs 2.2%; p = 0.02). The rate of new pacemaker implantation was 7.0% in the ELA cohort and 15.0% in the control cohort, respectively (p = 0.05). CONCLUSION: Treatment of ELA patients with third-generation TAVI prostheses is feasible and safe, providing similar device success and complication rates as in matched controls with regular-sized aortic annulus. Post-interventional pacemaker implantation rates were low compared to the control group, yet incidence of moderate PVL remains problematic in ELA patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios de Factibilidad , Diseño de Prótesis , Resultado del Tratamiento
19.
Clin Res Cardiol ; 113(1): 75-85, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37462856

RESUMEN

BACKGROUND: Various second-generation transcatheter heart valve (THV) prostheses with high clinical efficacy and safety are available, but there is limited large-scale data available comparing their hemodynamic performance and clinical implications. OBJECTIVE: To compare the hemodynamic performance and short-term clinical outcome of four second-generation THV prostheses. METHODS: 24,124 patients out of the German Aortic Valve Registry who underwent transfemoral transcatheter aortic valve implantation (TAVI) (Evolut™ R n = 7028, Acurate neo™ n = 2922, Portico n = 878 and Sapien 3 n = 13,296) were included in this analysis. Propensity-score weighted analysis was performed to control for differences in age, left ventricular function, STS score and sex. Primary endpoint was survival at one-year, secondary endpoints were 30 days survival, pre-discharge transvalvular gradients, paravalvular leakage and peri-procedural complications. RESULTS: Thirty-day and one-year survival were not significantly different between the four patient groups. Transvalvular gradients in Evolut™ R and Acurate neo™ were significantly lower as compared to Portico and Sapien 3 at hospital discharge. This difference exists across all annulus sizes. Paravalvular leakage ≥ II occurred significantly less often in the Sapien 3 group (1.2%, p < 0.0001). Rate of severe procedural complications was low and comparable in all groups. Permanent pacemaker implantation rate at one year was lowest in the ACUARATE neo group (13.0%) and highest in the Evolut™ R group (21.9%). CONCLUSION: Albeit comparable short-term clinical outcomes there are certain differences regarding hemodynamic performance and permanent pacemaker implantation rate between currently available THV prostheses which should be considered for individual prosthesis selection.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Sistema de Registros
20.
EuroIntervention ; 20(1): 85-94, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37982152

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation is an effective treatment for patients with aortic stenosis; however, complications related to paravalvular leakage (PVL) persist, including increased risk of mortality, cardiovascular mortality, and rehospitalisation. AIMS: We sought to evaluate the clinical outcomes and valve performance at 1 year in patients with severe aortic stenosis treated with the ACURATE neo2 valve in a post-market clinical setting. METHODS: Valve Academic Research Consortium-2 safety events were assessed up to 1 year. Independent core laboratories evaluated echocardiographic measures of valve performance and hypoattenuated leaflet thickening (HALT; as measured by four-dimensional computed tomography). RESULTS: The study enrolled 250 patients (64% female; mean age: 81 years; baseline Society of Thoracic Surgeons risk score: 2.9±2.0%); 246 patients were implanted with ACURATE neo2. All-cause mortality was 0.8% at 30 days and 5.1% at 1 year. The 1-year rates for stroke and disabling stroke were 3.0% and 1.3%, respectively. Overall, HALT of >50% leaflet involvement of at least one leaflet was present in 9% of patients at 30 days and in 12% of patients at 1 year. No association was observed between the presence of HALT and 1-year clinical or haemodynamic outcomes. Early haemodynamic improvements were maintained up to 1 year (mean aortic valve gradient: 47.6±14.5 mmHg at baseline, 7.6±3.2 mmHg at 1 year; mean aortic valve area: 0.7±0.2 cm2 at baseline, 1.7±0.4 cm2 at 1 year). At 1 year, 99% of patients had mild or no/trace PVL (<1% had moderate PVL; no patient had severe PVL). CONCLUSIONS: The study outcomes confirm favourable performance and safety up to 1 year in patients treated with ACURATE neo2 in routine clinical practice. (ClinicalTrials.gov: NCT04655248).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...