Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
1.
Odontology ; 112(2): 479-488, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37938400

RESUMEN

This in vitro study assessed peak temperature and temperature increase (ΔT) within the pulp chamber during different extended photoactivation techniques (EPT-applying similar radiant exposure values) to resin-based composites (RBCs) placed in a Class I cavity preparation in an extracted human lower third molar. A T-type thermocouple was placed in the pulp chamber and connected to a temperature analysis device (Thermes, Physitemp). The tooth was attached to an assembly simulating the in vivo environment (controlled baseline pulp chamber temperature and fluid flow). The real-time pulp chamber temperature was evaluated throughout the photoactivation (Bluephase N, Ivoclar Vivadent) of two bulk-fill RBCs: Tetric N Ceram Bulk Fill (TBF; shade: IVA; Ivoclar Vivadent); Surefill SDR flow + (SDR, shade: Universal; Dentsply Sirona), which were exposed to different curing techniques: 40 s-occlusal surface; 20 s-occlusal + 10 s-buccal + 10 s-lingual surfaces; 10 s-buccal + 10 s + lingual + 20 s-occlusal surfaces. Each EPT delivered 42.4 J/cm2. Vickers hardness (VHN) was measured on the removed, sectioned RBC restorations at the top and bottom middle areas after curing. ΔT and VHN data were analyzed using 2-way ANOVA followed by Bonferroni post-hoc test (α = 0.05). Peak temperature data were analyzed using one-way ANOVA and Dunnett's post-hoc test (α = 0.05). SDR showed higher ΔT values than TBF (p = 0.008) in some EPTs. Neither technique resulted in ΔT values greater than 5.5 °C. Both composites had acceptable bottom/top hardness ratios (greater than 80%), regardless of the photoactivation technique. The evaluated EPTs may be considered safe as a low-temperature increase was noticed within the pulp chamber.


Asunto(s)
Resinas Compuestas , Materiales Dentales , Humanos , Temperatura , Resinas Acrílicas , Poliuretanos , Ensayo de Materiales , Polimerizacion , Luces de Curación Dental
2.
Int J Prosthodont ; 0(0): 1-18, 2023 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-37988422

RESUMEN

PURPOSE: The aim of this study was to evaluate the effect of toothbrushing on the surface roughness (Sa), roughness profile (Rv), gloss units (GU) and surface morphology of three glazed ceramics. MATERIALS AND METHODS: Specimens (n=7) from different CAD/CAM materials 1- Lithium disilicate-based glass ceramic (IPS e.max CAD); 2- Zirconia-reinforced lithium silicate glass ceramic (Celtra Duo) and 3- 6 mol% yttria partially-stabilized zirconia (InCoris) were evaluated. IPS e.max CAD and InCoris specimens were sintered and all the groups were pre-polished and glazed according to the manufacturer's recommendations: IPS Ivocolor Glaze Paste (Ivoclar Vivadent) or Universal Overglaze High Flu (Dentsply/Sirona). Sa, Rv, GU and morphology were analyzed before and after brushing at 30.000, 120.000 and 180.000 cycles. The data of Sa and GU were analyzed by ANOVA two-way and post-hoc Tukey's test (α=0.05). Rv was analyzed by Kruskal-Wallis and Student-Newman-Keuls. The surface morphology was analyzed qualitatively. RESULTS: The Sa decreased significantly after 180.000 toothbrushing cycles for all materials tested. CE showed higher Rv than EM and IN, and IN showed the highest GU after 180.000 toothbrushing cycles, which promoted a polishing effect for all materials. CONCLUSION: Long-term toothbrushing was not able to jeopardize the glazed-surface of all tested materials compared to unbrushed.

3.
Dent Mater ; 39(7): e1-e11, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37248138

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate the effect of build orientation of 3D-printed provisional resins (3DRs) on gloss (Gs), surface roughness (Sa), maximum profile valley depth (Rv), and color difference (∆E00). METHODS: PMMA CAD/CAM blocks (Vita Temp/Vita) were sectioned and served as a Control. Four 3DRs (Cosmos-SLA/Yller, Cosmos-DLP/Yller, PriZma-Bioprov/Makertech, Nanolab/Wilcos) were obtained as discs (15-mm diameter, 2.5-mm thickness) in three orientations (0°, 45°, and 90°) using different 3D printers (Form 2/Formlabs, P30/Straumann, Hunter/Flashforge, W3D/Wilcos, respectively). Samples were then cleaned with isopropyl alcohol prior to post-curing in specific post-curing units. Half of the samples' surface was covered with an adhesive tape and submitted to 10,000 toothbrushing (TB) cycles. The Gs and Sa at the brushed and not brushed surfaces were evaluated with a glossmeter (Novo-curve) and a laser confocal microscope (OLS5000) (n = 10), which also obtained the Rv and 3D representative images of the interface between not brushed and brushed surfaces. Electron microscopy images of the surface of some samples was also performed (n = 3). On another set of samples (n = 5), the coordinates of luminosity and color were obtained with a spectrophotometer (Easyshade V) at baseline and after 16.7 h and 200 h of UVB aging, to calculate the ∆E00 using CIEDE:2000 formula. Additionally, 3DRs photoinitiators were identified using a minispectrometer (USB2000 +) (n = 5). Data of Gs and Sa were submitted to three-way-, Rv to two-way-, and ∆E00 to mixed-ANOVA tests, followed by Tukey's test (α = 0.05). For all variables, results from experimental groups were compared to control using Dunnett's test (α = 0.05). Student's t-test was used to compare the control at different TB cycles (Gs, Sa) or aging periods (∆E00) (α = 0.05). RESULTS: Build orientation of 3DRs did not influence any of the variables studied. The 10,000 TB cycles resulted in a decrease in Gs and increase in Sa for all resins tested. The control showed higher Gs after 10,000 TB cycles than Cosmos-SLA and Nanolab resins. Compared to all 3DRs, Control presented lower ∆E00 after 200 h of UVB aging. All 3DRs presented higher ∆E00 than the clinically acceptable after 200 h of UVB aging. Lucirin® TPO was identified in all 3DRs, although PriZma might also present other photoinitiators and Nanolab might present Irgacure 369. SIGNIFICANCE: Alterations in build orientation are very useful and frequently performed in the day-today of 3D-printing, thus its effect in the optical properties and in the topography of 3D-printed restorations is very relevant. For the evaluated 3D-printed provisional resins, build orientation did not influence any of the variables studied (Gs, Sa, Rv, and ∆E00), even after toothbrushing cycles and UVB aging.


Asunto(s)
Resinas Compuestas , Materiales Dentales , Humanos , Ensayo de Materiales , Propiedades de Superficie , Impresión Tridimensional , Color
4.
Braz Dent J ; 33(5): 100-107, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36287491

RESUMEN

To evaluate the flexural strength (FS) and flexural modulus (FM) of a commercial 3Y-TZ0P ceramic after artificial aging and either without or with two application times of non-thermal plasma treatments (NTP). In addition, changes in crystalline phase transformation and surface nano-topography after NTP application, during different aging periods, were evaluated. Ninety 3Y-TZP bars (45x4x3 mm) were made for FS and FM testing, and assigned to nine groups (n=10): no NTP/no aging (Control); no NTP/4h aging; no NTP/30h aging; 10s NTP/no aging; 10s NTP/4h aging; 10s NTP/30h aging; 60s NTP/no aging; 60s NTP/4h aging and 60s NTP/30h aging. Artificial accelerated aging was simulated using an autoclave (134º C at 2 bar) for up to 30h. FS and FM were assessed using a universal testing machine and data analyzed using a ANOVA and Tukey test (α=0.05). The volume change in zirconia monoclinic phase (MPV) was evaluated using X-ray diffraction and surface nano-topography was assessed using atomic force microscopy (baseline until 30h-aging). NTP application did not influence the FS and FM of zirconia. Compared to the Control (no NTP/no aging), the FS of zirconia samples treated for 30 hours in autoclave ("no NTP/30h aging" group) increased. Artificial aging for 30 hours significantly increased the FM of zirconia, regardless of NTP application. MPV tended to increase following the increase in aging time, which might result in the surface irregularities observed at 30h-aging. NTP did not alter the zirconia properties tested, but 30h-aging can change the zirconia FS, FM and MPV.


Asunto(s)
Gases em Plasma , Materiales Dentales/química , Argón , Ensayo de Materiales , Propiedades de Superficie , Circonio/química , Cerámica/química , Itrio/química
5.
J Mech Behav Biomed Mater ; 136: 105479, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36279743

RESUMEN

PURPOSE: This study evaluated the effects of 3D-printing build orientation on accuracy, flexural modulus (FM), flexural strength (FS), and microhardness of selected, commercial 3D-printed provisional resins (3DRs). MATERIAL AND METHODS: PMMA CAD/CAM provisional material (Vita Temp/Vita) served as Control. Four 3DRs (Cosmos-SLA/Yller, Cosmos-DLP/Yller, PriZma-Bioprov/Makertech, Nanolab/Wilcos) were used in three printing orientations (0°, 45°, and 90°). Printed samples were cleaned with isopropyl alcohol prior to post-curing in specific post-curing units. For each group, 20 bar-shaped samples (25 × 2x2 mm) and ten disc-shaped samples (15-mm diameter, 2.5-mm thick) were obtained. The dimensions of bar samples were measured and the mean percent errors were compared to the reference (digital) values to obtain "accuracy" (n = 20). Samples were then aged in distilled water at 37 °C and half were submitted to a three-point bend test in a universal testing machine after 24 h and the other half after 1 year (n = 10). Disc samples were polished prior to microhardness evaluation (n = 10). Microstructure and elemental composition of filler particles in the 3DRs were analyzed using scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS) (n = 3). Accuracy and microhardness were submitted to two way-, and FM and FS to three way-ANOVA, followed by Tukey's tests. Results of experimental groups were compared to a milled PMMA Control using Dunnett's tests, and Student's t-tests compared FM and FS to Control at different aging periods (α = 0.05). RESULTS: Except for Cosmos-DLP, the 90° orientation demonstrated the best overall accuracy in all dimensions evaluated. The overall accuracy of Cosmos-SLA was not significantly different from Control and higher than other 3DRs. The FM of all 3DRs was lower than Control, regardless of orientation and aging period. After 1 year of aging, FS of 45°-Cosmos-SLA and all orientations of PriZma were not different from Control, while 90°-Cosmos-SLA was higher. Build orientation had no influence on microhardness of the 3DRs: Nanolab was the only resin harder than Control. Very few nanometric spherical filler particles were found in Cosmos-SLA, Cosmos-DLP, and PriZma, while Nanolab presented higher number of particles having irregular shapes and sizes. CONCLUSIONS: In general, although build orientation did not influence microhardness results, the 90° -orientation resulted in the best overall accuracy for most 3DRs. After 1-year water storage, Cosmos-SLA printed vertically showed the highest FS, while the PMMA Control obtained the highest FM for both aging periods.


Asunto(s)
Resistencia Flexional , Polimetil Metacrilato , Ensayo de Materiales , Impresión Tridimensional , Agua , Propiedades de Superficie
6.
Braz. dent. j ; 33(5): 100-107, Sep.-Oct. 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1403784

RESUMEN

Abstract To evaluate the flexural strength (FS) and flexural modulus (FM) of a commercial 3Y-TZ0P ceramic after artificial aging and either without or with two application times of non-thermal plasma treatments (NTP). In addition, changes in crystalline phase transformation and surface nano-topography after NTP application, during different aging periods, were evaluated. Ninety 3Y-TZP bars (45x4x3 mm) were made for FS and FM testing, and assigned to nine groups (n=10): no NTP/no aging (Control); no NTP/4h aging; no NTP/30h aging; 10s NTP/no aging; 10s NTP/4h aging; 10s NTP/30h aging; 60s NTP/no aging; 60s NTP/4h aging and 60s NTP/30h aging. Artificial accelerated aging was simulated using an autoclave (134º C at 2 bar) for up to 30h. FS and FM were assessed using a universal testing machine and data analyzed using a ANOVA and Tukey test (α=0.05). The volume change in zirconia monoclinic phase (MPV) was evaluated using X-ray diffraction and surface nano-topography was assessed using atomic force microscopy (baseline until 30h-aging). NTP application did not influence the FS and FM of zirconia. Compared to the Control (no NTP/no aging), the FS of zirconia samples treated for 30 hours in autoclave ("no NTP/30h aging" group) increased. Artificial aging for 30 hours significantly increased the FM of zirconia, regardless of NTP application. MPV tended to increase following the increase in aging time, which might result in the surface irregularities observed at 30h-aging. NTP did not alter the zirconia properties tested, but 30h-aging can change the zirconia FS, FM and MPV.


Resumo Avaliar a resistência à flexão (FS) e o módulo de flexão (FM) de uma cerâmica comercial 3Y-TZP após envelhecimento artificial, e com ou sem dois tempos de aplicação de plasma não térmico (NTP). Além disso, a transformação de fase cristalina e a nano-topografia de superfície após a aplicação de NTP, durante diferentes períodos de envelhecimento, foram avaliadas. Noventa barras 3Y-TZP (45x4x3 mm) foram feitas para testes de FS e FM, e distribuídas em nove grupos (n=10): sem NTP/sem envelhecimento (Controle); sem NTP/4h de envelhecimento; sem NTP/30h de envelhecimento; 10sNTP/sem envelhecimento; 10sNTP/4h; 10sNTP/30h; 60sNTP/sem envelhecimento; 60sNTP/4h e 60sNTP/30h. O envelhecimento artificial acelerado foi simulado em autoclave (134º C a 2 bar) por até 30 horas. FS e FM foram avaliados em máquina de ensaio universal e os dados analisados ​​pela ANOVA e teste de Tukey (α = 0,05). A mudança de volume da fase monoclínica de zircônia (MPV) foi avaliada usando difração de raios-X e nano-topografia de superfície foi avaliada utilizando microscopia de força atômica (baseline até 30h). A aplicação do NTP não influenciou a FS e FM da zircônia. Comparado ao Controle ("sem NTP/sem envelhecimento"), a FS das amostras de zircônia tratadas por 30 horas em autoclave ("sem NTP/30h de envelhecimento") aumentou. O envelhecimento artificial por 30 horas aumentou significativamente a FM da zircônia, independente do tempo de aplicação do NTP. O MPV tendeu a aumentar em função do aumento do tempo de envelhecimento para todos os grupos, que pode ter resultado nas irregularidades superficiais observadas com 30 horas de envelhecimento. O NTP não afetou as propriedades da zircônia testadas, mas o envelhecimento por 30 horas pode alterar a FS, FM e MPV da zircônia.

7.
Clin Oral Investig ; 26(5): 3899-3910, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35006294

RESUMEN

OBJECTIVES: This study characterized a violet LED light (V-LED; bright max whitening) tooth whitening device and evaluated its efficacy on stained enamel compared to hydrogen peroxide (HP). MATERIALS AND METHODS: Characterization of the V-LED beam profile was performed using a laser beam-profiler. The irradiance was measured throughout an exposure cycle at 0- and 8-mm distances using an integrating sphere and a spectral radiometer. Bovine enamel/dentin blocks stained with black tea (BT), cigarette smoke (CS), or without staining (CONT) were subjected to V-LED or 40% HP (n = 10/group). Color parameters (ΔL, Δa, Δb, and ΔE00) were measured using a digital spectrophotometer. Light transmission was estimated through 1-mm-thick bovine enamel slices (n = 5). ΔL, Δb, ΔE00, and irradiance were analyzed by two-way ANOVAs and Tukey's tests, Δa by Kruskal-Wallis and Mann-Whitney tests, and light transmission by t-test (α = 5%). RESULTS: Heterogeneous beam distribution was observed for the emitting V-LED chips. After 20 sequential exposures, irradiance levels were reduced 25-50%, regardless of the distance from V-LED. Localized irradiance values were statistically different between beam locations and different distances from the target. V-LED produced lower ΔE00, ΔL, Δa, and Δb values than HP for CONT and BT, with no differences for CS. Light transmittance decreased approximately 98% through 1-mm thick enamel. CONCLUSIONS: V-LED irradiance was heterogeneous and decreased throughout the exposure cycles and was also greatly reduced with increasing tip distance. V-LED produced a significantly lower whitening effect on BT and control teeth. CLINICAL RELEVANCE: This study contributes to the knowledge of V-LED and its clinical use.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Animales , Bovinos , Color , Esmalte Dental , Peróxido de Hidrógeno , Luz , , Blanqueadores Dentales/farmacología
8.
J Esthet Restor Dent ; 34(2): 412-422, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34569699

RESUMEN

OBJECTIVE: To evaluate the influence of shades of a multilayered zirconia on light transmission, resin cement degree of conversion, and shear bond strength of resin cement. MATERIALS AND METHODS: The light transmission through opaque (OPQ) and translucent (TNS) regions of Katana UTML zirconia (Kuraray Noritake Dental) were evaluated for using a spectroradiometer (n = 5). Degree of conversion of dual-cure resin cement (Panavia V5, Kuraray Noritake Dental) was measured after light-activation through OPQ or TNS regions and direct exposure. Composition of the zirconia was analyzed with energy dispersive x-ray spectroscopy (EDS). Shear bond strength (SBS) was evaluated on the OPQ and TNS regions after 24 h and 1 year from specimen preparation (n = 15). RESULTS: The OPQ region produced higher irradiance loss (95.1%) than TNS one (92.9%), and lower degree of conversion (52.4%) than TNS (71.2%) at 24 h post-light activation. EDS analysis did not show differences on the microstructure of the OPQ and TNS regions. There were no significant differences on the SBS between zirconia regions. For both zirconia regions, a significant reduction on the SBS occurred after aging, being 31.7% for OPQ and 38% for TNS. CONCLUSION: Both OPQ and TNS regions affected the light transmission through the multilayered zirconia. The OPQ region yielded the highest light attenuation and the lowest degree of conversion of resin cement. Different regions of the zirconia did not influence the SBS. Clinical significance Although opaque and translucent regions of the multilayered zirconia reduced the light transmission from LED curing unit and the degree of conversion of resin cement, the regions did not affect the resin cement adhesion.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Cerámica/química , Análisis del Estrés Dental , Ensayo de Materiales , Cementos de Resina/química , Propiedades de Superficie , Circonio/química
9.
Clin Oral Investig ; 26(3): 3141-3150, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34826031

RESUMEN

OBJECTIVES: To evaluate the biaxial flexural strength (BFS), flexural modulus (BFM), and Knoop microhardness (KHN) of incremental and bulk-filled resin-based composites (RBCs) using extended curing exposure times. MATERIALS AND METHODS: Disc specimens (n = 8; 6-mm diameter) were fabricated using three stacked molds (0.5-mm thick for the top and bottom molds, and a 1-mm-thick center mold for the conventional and 3-mm thick for the bulk-fill RBCs). Conventional (Tetric EvoCeram/TCE and Filtek Z250/FIZ) and bulk-fill RBCs (Tetric EvoCeram Bulk Fill/TBF and Filtek One Bulk Fill Restorative/FOB) were evaluated. The stacked RBC-filled molds were light-cured for (1) the manufacturer-recommended exposure (MRE) duration; (2) 50%, and (3) 100% extension of the MRE. The BFS, BFM, and KHN of the top and bottom discs were measured. BFS and BFM were analyzed by three-way ANOVA (material*curing time*depth) and Tukey's post hoc (α = 0.05). KHN was analyzed by two-way ANOVA (curing time*depth) and Tukey's post hoc (α = 0.05). RESULTS: Extending the exposure duration did not change the BFS and BFM on the top of the RBCs, but the BFS and KHN increased at the bottom of bulk-fill RBCs. For the conventional RBCs, TCE showed the highest increase on BFS at the bottom, going from 53.6 MPa at T1 to 69.9 at T3. Among the bulk-fill RBCs, FOB presented the highest increase on the bottom BFS (T1: 101.0 ± 19.9 MPa, T3: 147.6 ± 12.9 MPa). For all RBCs and exposure times, BFS and KHN were lower at the bottom. Only FIZ and FOB reached a bottom-to-top hardness ratio of 80%, at T3 and T2. CONCLUSION: A significant increase on the BFS and KHN on the bottom of bulk-fill RBCs can be observed when the time of exposure to the curing light is double the MRE. However, extended exposure does not eliminate differences on the BFS and KHN between the shallow and deep regions of RBCs. TCE and TBF failed to reach an acceptable B/T hardness ratio at all evaluated exposure times. CLINICAL RELEVANCE: Mechanical properties of RBCs can be affected by insufficient polymerization, specially at deeper regions of the increment. Therefore, clinicians should consider applying twice the MRE to curing-light to polymerize the maximal increment thickness of bulk-fill RBCs.


Asunto(s)
Resinas Compuestas , Materiales Dentales , Resistencia Flexional , Dureza , Ensayo de Materiales , Polimerizacion , Propiedades de Superficie
10.
Braz Oral Res ; 35: e120, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34878075

RESUMEN

The purpose of this study was to describe the synthesis, characterization, and functionalization of b-NaYF4:30%Yb/0.5%Tm upconverting nanocrystals for use as nanofillers in a dental adhesive and microscopically evaluate the interface between the particles and a commercial adhesive. The upconverting nanoparticles were synthesized and purified by thermal decomposition, and their chemical composition determined by energy dispersive X-Ray spectroscopy. The crystalline structure was characterized using X-Ray diffraction and morphology and size were observed with scanning and transmission electron microscopy. Upconverting emission was evaluated by spectrophotometry irradiating the particles with a 975 nm diode laser. Particles were functionalized with polyacrylic acid and the success was confirmed by measurement of Zeta Potential and transmission electron microscopy. The results of X-ray diffraction found a pure hexagonal phase crystalline pattern. Scanning electron microscopy showed uniform dispersion of hexagonal-shaped particles of approximately 150 nm. Upconversion emission was observed in 344 nm, 361 nm, 450 nm, 474nm, 646 nm, 803 nm. Functionalization success was confirmed by formation of a stable aqueous colloid with a Zeta potential of -29.5mV and the absence of voids in the particle-adhesive interface on the transmission electron microscopy images. The reported synthesis and functionalization process produced upconverting nanoparticles emitting photons within the blue spectral region (450 nm and 474 nm).


Asunto(s)
Nanopartículas , Cementos Dentales , Microscopía Electrónica de Transmisión , Difracción de Rayos X
11.
J Esthet Restor Dent ; 33(4): 628-635, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33675162

RESUMEN

BACKGROUND: Bulk-fill materials can facilitate the restorative procedure mainly for deep and wide posterior cavities. The purpose of this study was to evaluate flexural strength (biaxial flexural strength [BFS]) and microhardness (Knoop microhardness [KHN]) at different depths of bulk-fill materials. METHODS: Five bulk-fill materials were tested: two light-curable composite resins, one dual-cure composite, one bioactive restorative, and a high-viscosity glass ionomer. A conventional composite was used as control. BFS and KHN were tested at different depths. Data was analyzed by two- and one-way ANOVAs, respectively and Tukey's post-hoc (α=0.05). RESULTS: The high-viscosity glass ionomer material presented the lowest BFS at all depths. KHN for the two light-curable and the dual-cure bulk-fill resin composites was reduced following an increase in restoration depth, while the conventional composite, the bioactive material, and the high-viscosity glass ionomer were not affected. CONCLUSION: There are differences in the properties of the tested materials at 4 mm depth, showing that the studied properties of some materials vary according to the cavity depth, although the results are material dependent. CLINICAL SIGNIFICANCE: Mechanical properties of light-cured, bulk-fill materials may be affected by inadequate polymerization. Clinicians should consider complementary strategies to achieve adequate polymerization at high-increment depths.


Asunto(s)
Materiales Dentales , Resistencia Flexional , Resinas Compuestas , Ensayo de Materiales , Polimerizacion
12.
Braz. oral res. (Online) ; 35: e120, 2021. graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1350372

RESUMEN

Abstract: The purpose of this study was to describe the synthesis, characterization, and functionalization of b-NaYF4:30%Yb/0.5%Tm upconverting nanocrystals for use as nanofillers in a dental adhesive and microscopically evaluate the interface between the particles and a commercial adhesive. The upconverting nanoparticles were synthesized and purified by thermal decomposition, and their chemical composition determined by energy dispersive X-Ray spectroscopy. The crystalline structure was characterized using X-Ray diffraction and morphology and size were observed with scanning and transmission electron microscopy. Upconverting emission was evaluated by spectrophotometry irradiating the particles with a 975 nm diode laser. Particles were functionalized with polyacrylic acid and the success was confirmed by measurement of Zeta Potential and transmission electron microscopy. The results of X-ray diffraction found a pure hexagonal phase crystalline pattern. Scanning electron microscopy showed uniform dispersion of hexagonal-shaped particles of approximately 150 nm. Upconversion emission was observed in 344 nm, 361 nm, 450 nm, 474nm, 646 nm, 803 nm. Functionalization success was confirmed by formation of a stable aqueous colloid with a Zeta potential of −29.5mV and the absence of voids in the particle-adhesive interface on the transmission electron microscopy images. The reported synthesis and functionalization process produced upconverting nanoparticles emitting photons within the blue spectral region (450 nm and 474 nm).

13.
J World Fed Orthod ; 9(2): 68-74, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32672657

RESUMEN

OBJECTIVES: The purpose of this study was to identify the combination of orthodontic adhesive resins and light-emitting diode (LED) light-curing units (LCUs) that result in the highest degree of resin conversion (DC). The hypothesis tested was that pairing orthodontic resins with LCUs from the same manufacturer produces higher DC versus unpaired resins and LCUs. METHODS: Pre-polymerization spectra of adhesive resins (Transbond XT [3M Unitek], BracePaste [American Orthodontics] or Opal Bond MV [Opal by Ultradent]) were obtained at oral temperature (37°C) using an attenuated total reflectance (ATR) diamond crystal (Golden Gate, Specac) in a Fourier-transform infrared (FTIR) spectrometer (Nicolet IS50). Resin specimens were polymerized using various LCUs (Ortholux Luminous [3M Unitek], Blue Ray 3 [American Orthodontics], or VALO Ortho Cordless [Ultradent Products, Inc.]) before obtaining post-polymerization infrared (IR); spectra. Twelve LCU-resin combinations were tested (n = 20/combination), half with a bracket present (Mini Diamond Twin, Ormco) and half without. DC values (%) were calculated using the two-frequency method and tangent-baseline technique. Data for each resin were statistically analyzed using General Linear Models and Student-Newman-Keuls post hoc tests (α = 0.05). RESULTS: Statistically significant differences were found within each resin for the groups without brackets present (P < 0.0001), the groups with brackets present (P < 0.0001), and the groups with brackets when compared with the manufacturer-paired group without a bracket (P < 0.0001). CONCLUSIONS: Adhesive resins and LCUs from the same manufacturer did not consistently result in statistically higher mean DC values than unpaired combinations. Metal brackets do not uniformly reduce the degree of conversion of adhesive resins when assessed using IR spectrometry.


Asunto(s)
Resinas Compuestas , Luces de Curación Dental , Curación por Luz de Adhesivos Dentales , Ensayo de Materiales , Ortodoncia/instrumentación , Resinas Compuestas/química , Humanos , Soportes Ortodóncicos , Polimerizacion , Espectroscopía Infrarroja por Transformada de Fourier
14.
Dent Mater ; 36(9): 1201-1213, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32576408

RESUMEN

OBJECTIVE: To evaluate the influence of light emitted from two Polywave®, LED light-curing units (LCU) on in vivo pulp temperature (PT) rise and signs of acute inflammatory response in pulps of human premolar having deep Class V preparations. METHODS: Sixty intact, first premolars from 15 volunteers requiring extraction received infiltrative anesthesia. A sterile thermocouple probe was inserted within the pulp tissue through a minute occlusal pulp exposure in only 45 teeth (n = 9) to continuously monitor PT (°C). A deep buccal Class V preparation was created, and the surface was exposed to light from a commercial Polywave LCU (Bluephase 20i (20i), Ivoclar Vivadent) or from an experimental LCU (Exp) using the exposure modes (EM): 1s/Exp and 2s/Exp, 10s/20i, 20s/20i, and 60s/20i. Peak PT and PT rise values above baseline (ΔT) data were evaluated using a one-way ANOVA followed by Tukey's post-hoc test (α = 5%). Teeth used for histological and immunohistochemical analyses (n = 3) were extracted approximately 2 h after exposure to the LCU. RESULTS: No significant difference in peak PT and ΔT values was noted between 2s/Exp and 20s/20i groups, which both exhibited higher values than 1s/Exp and 10s/20i groups (p < 0.001). Dilated and congested blood vessels were seen after exposure to 1s/Exp, 2s/Exp, or 60s/20i EMs. The expression of IL-1ß and TNF-α tended to be more intense when higher irradiance was delivered. SIGNIFICANCE: Although higher irradiance delivered over a short exposure caused lower PT rise than 5.5 °C, such EMs should be used with caution, as they have more potential to harm the pulp tissue.


Asunto(s)
Luces de Curación Dental , Curación por Luz de Adhesivos Dentales , Diente Premolar , Resinas Compuestas , Pulpa Dental , Humanos , Temperatura
15.
Eur J Oral Sci ; 128(4): 336-344, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32502304

RESUMEN

This study evaluated the effect of extending the duration of exposure to curing light on the depth of cure of two conventional (RBC1-conventional and RBC2-conventional) and two bulk-fill (RBC1-bulk and RBC2-bulk) resin composites. Polywave and single-peak photocuring units were used. Cylinder-shaped specimens were exposed to curing light either for the time period recommended by the manufacturer or twice the length of that time, and depth of cure was estimated using manual scraping (similar to the ISO-4049 standard) and solvent immersion techniques. Depth of cure was analyzed, using two-way ANOVA, for the factors measurement method and exposure time. For RBC1-conventional and RBC1-bulk, the solvent immersion technique estimated a greater depth of cure than did manual scraping; for RBC1-conventional, both techniques and both light-exposure time periods resulted in a depth of cure of >2 mm; and for RBC1-bulk, only the solvent method after photocuring for twice the manufacturer's recommended time resulted in a depth of cure of 5 mm. For RBC2-conventional and RBC2-bulk, neither technique nor exposure time resulted in estimated depths of cure that matched those indicated by the manufacturer. The results suggest that extending the duration of photopolymerization increases depth of cure. Also, calculation of depth of cure can vary according to the measurement technique used.


Asunto(s)
Resinas Compuestas , Luces de Curación Dental , Dureza , Curación por Luz de Adhesivos Dentales , Ensayo de Materiales , Polimerizacion , Propiedades de Superficie
16.
J Esthet Restor Dent ; 32(4): 371-379, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31709731

RESUMEN

OBJECTIVE: This study examines monomer permeation of commercial dental adhesive through nitrile-based gloves, and correlates findings with clinical case studies of dental students having localized skin eruptions following resin placement on a gloved hand to manipulate composite. METHODS: Three dental students self-reported presenting itchy, red skin lesions underneath the area where they placed uncured adhesive resin on a nitrile-gloved hand. Histories and cursory examinations were performed in the Department of Dermatology at The Medical College of Georgia. Infrared spectroscopic methods were used to determine permeation times of known monomer components of commercial adhesive material used through nitrile glove. Monomer permeation times were correlated with the time when the commercial adhesive first applied and penetrated through the glove. RESULTS: Assessment by the dermatologist concluded that the reporting students had occupational contact dermatitis resulting from components of the adhesive permeating through the barrier glove. Permeation times of neat monomer components of the adhesive resin varied over a wide range, with lower molecular weight showing faster pass-through times. Spectroscopic interpretation indicated that the probable causative agent for the student's skin reaction was 2-hydroxyethyl methacrylate (HEMA). CONCLUSIONS: Probable correlation of the observed skin reaction sites was made with diffusion of HEMA in the uncured dental adhesive formulation through nitrile glove material. CLINICAL SIGNIFICANCE: All measures to prevent skin contact with uncured methacrylate-based resin components should be taken, including avoidance of resin permeation through a gloved hand. Sensitization to one type of methacrylate can result in sensitization to other types of resins within this family, significantly impacting the careers of both dental auxiliaries as well as clinicians.


Asunto(s)
Recubrimiento Dental Adhesivo , Hipersensibilidad , Guantes Protectores , Humanos , Nitrilos , Permeabilidad
17.
Braz Dent J ; 30(4): 397-403, 2019 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-31340231

RESUMEN

This study measured and compared exitance irradiance and power of 4 commercial dental light-curing units (LCU) (Elipar S10, Elipar DeepCure-S, Corded VALO and Bluephase Style) using different types of radiometers. The devices used to analyze the LCU were classified as either handheld analog (Henry Schein, Spring, Demetron 100A, Demetron 100B and Demetron 200), handheld digital (Bluephase 1, Bluephase II, Coltolux, CureRite and Hilux), or laboratory instruments (Thermopile and Integrating Sphere). The laboratory instruments and the Bluephase II radiometer were also used to measure the LCU's power (mW). The LCU's were activated for 20 s (n=5). Data were analyzed using Kruskal-Wallis and Student-Newman-Keuls multiple comparison test (a=0.05). Among the LCU, the laboratory instruments presented different irradiance values, except for Corded VALO. The Coltolux and Hilux radiometers measured greater irradiance values compared to the laboratory instruments for the four LCUs tested. Within a given LCU, handheld analog units measured lower irradiance values, compared to handheld digital and laboratory instruments, except using the Spring radiometer for the Elipar S10 LCU. None of the handheld radiometers were able to measure similar irradiance values compared to laboratory instruments, except for Elipar S10 when comparing Bluephase 1 and Thermopile. Regarding power measurement, Bluephase II always presented the lowest values compared to the laboratory instruments. These findings suggest that the handheld radiometers utilized by practitioners (analog or digital) exhibit a wide range of irradiance values and may show lower outcomes compared to laboratory based instruments.


Asunto(s)
Luces de Curación Dental , Radiometría , Resinas Compuestas , Humanos , Ensayo de Materiales
18.
Eur J Dent ; 13(1): 69-74, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31170753

RESUMEN

OBJECTIVE: This study measured the in vivo temperature of prepared root canal walls during various stages of treatment prior to endodontic postcementation. MATERIALS AND METHODS: One tooth each from five patients requiring endodontic treatment received conventional gutta-percha obturation. The coronal 4 mm of gutta-percha was removed by drilling and the canal wall temperature was measured. A sterile, saline rinse was applied, and another temperature value was recorded. Paper points were placed, and the wall temperature was recorded. A standardized period of 1.5 minute passed, simulating time needed to mix and place the resin cement and post (no resin was placed), after which the final wall temperature was obtained. The tooth was temporized and scheduled for prosthetic reconstruction. A one-way repeated measure analysis of variance (with Tukey's post hoc test) was performed among mean temperature values for each treatment stage (preset α 0.05). RESULTS: Significant temperature differences were found among the treatment stages. Canal space drilling yielded the highest temperature (35.5 ± 0.8°C), while the lowest was obtained after saline rinsing (34.0 ± 0.9°C). The temperature of prepared root canal wall prior to postplacement (34.9 ± 1.2°C) and following paper point drying (34.8 ± 1.1°C) presented intermediate results, with no statistical difference between them. CONCLUSIONS: This study suggested that root canal wall temperature varied during various stages of preparation prior to endodontic post.

19.
J Appl Oral Sci ; 27: e20180480, 2019 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-31116279

RESUMEN

OBJECTIVES: To measure and compare in vivo and in vitro pulp temperature (PT) increase (ΔTEMP) over baseline, physiologic temperature using the same intact upper premolars exposed to the same Polywave® LED curing light. METHODOLOGY: After local Ethics Committee approval (#255,945), local anesthesia, rubber dam isolation, small occlusal preparations/minute pulp exposure (n=15) were performed in teeth requiring extraction for orthodontic reasons. A sterile probe of a temperature measurement system (Temperature Data Acquisition, Physitemp) was placed within the pulp chamber and the buccal surface was sequentially exposed to a LED LCU (Bluephase 20i, Ivoclar Vivadent) using the following exposure modes: 10-s low or high, 5-s Turbo, and 60-s high. Afterwards, the teeth were extracted and K-type thermocouples were placed within the pulp chamber through the original access. The teeth were attached to an assembly simulating the in vivo environment, being similarly exposed while real-time temperature (°C) was recorded. ΔTEMP values and time for temperature to reach maximum (ΔTIME) were subjected to two-way ANOVA and Bonferroni's post-hoc tests (pre-set alpha 0.05). RESULTS: Higher ΔTEMP was observed in vitro than in vivo. No significant difference in ΔTIME was observed between test conditions. A significant, positive relationship was observed between radiant exposure and ΔTEMP for both conditions (in vivo: r2=0.917; p<0.001; in vitro: r2=0.919; p<0.001). CONCLUSION: Although the in vitro model overestimated in vivo PT increase, in vitro PT rise was close to in vivo values for clinically relevant exposure modes.


Asunto(s)
Luces de Curación Dental , Pulpa Dental/efectos de la radiación , Temperatura , Análisis de Varianza , Luces de Curación Dental/efectos adversos , Humanos , Técnicas In Vitro , Dosis de Radiación , Exposición a la Radiación , Valores de Referencia , Análisis de Regresión , Reproducibilidad de los Resultados , Factores de Tiempo
20.
J Prosthodont Res ; 63(2): 232-238, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30598403

RESUMEN

PURPOSE: The aim of this study was to evaluate the influence of indirect restorative material type and thickness on the transmission of different wavelengths from a broad-banded dental curing light. METHODS: Four dental indirect restorative materials for computer-aided design and computer-aided manufacturing (CAD/CAM) were evaluated: [RC] resin/ceramic hybrid material (Lava Ultimate), [FC] feldspathic ceramic (VitaBlocs), and two zirconia-based ceramics ([ZK] Katana; and [ZL] Lava). Total loss of irradiance (TL) was measured for blue (WB, 425-490nm) and violet (WV, 350-425nm) wavelengths. Specimens of 15×15mm with varying thicknesses (0.5, 1.0, 1.5, and 2.0mm) were fabricated (n=5). A plasma-arc dental light-curing unit was used (Arc Light-II). To assess TL as a function of wavelength, a software (Spectra Suite v5.1) connected to a spectroradiometer (USB2000) and an integrating sphere (CTSM-LSM-60-SF) was used. Data was subjected to statistical analysis (two-way ANOVA and post-hoc Tukey test, α=0.05). RESULTS: A 0.5mm interposition resulted in TL from 50.5 to 67.2%, depending on material. Increased thickness resulted in higher TL for all materials. FC showed less TL compared to ZK. In general, WV showed higher TL than did WB, and WV/WB proportion decreased with increasing thickness. CONCLUSIONS: Indirect materials significantly reduced TL, and this effect is greater with increasing thickness. WV showed lower penetration compared to WB.


Asunto(s)
Materiales Dentales , Curación por Luz de Adhesivos Dentales , Luz , Ensayo de Materiales , Cerámica , Resinas Compuestas , Diseño Asistido por Computadora , Polimerizacion , Cementos de Resina , Circonio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...