Fetal Diagn Ther ; 51(2): 184-190, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38198774

RESUMEN

INTRODUCTION: Randomized controlled trials found that fetoscopic endoluminal tracheal occlusion (FETO) resulted in increased fetal lung volume and improved survival for infants with isolated, severe left-sided congenital diaphragmatic hernia (CDH). The delivery room resuscitation of these infants is particularly unique, and the specific delivery room events are largely unknown. The objective of this study was to compare the delivery room resuscitation of infants treated with FETO to standard of care (SOC) and describe lessons learned. METHODS: Retrospective single-center cohort study of infants treated with FETO compared to infants who met FETO criteria during the same period but who received SOC. RESULTS: FETO infants were more likely to be born prematurely with 8/12 infants born <35 weeks gestational age compared to 3/35 SOC infants. There were 5 infants who required emergent balloon removal (2 ex utero intrapartum treatment and 3 tracheoscopic removal on placental bypass with delayed cord clamping) and 7 with prenatal balloon removal. Surfactant was administered in 6/12 FETO (50%) infants compared to 2/35 (6%) in the SOC group. Extracorporeal membrane oxygenation use was lower at 25% and survival was higher at 92% compared to 60% and 71% in the SOC infants, respectively. CONCLUSION: The delivery room resuscitation of infants treated with FETO requires thoughtful preparation with an experienced multidisciplinary team. Given increased survival, FETO should be offered to infants with severe isolated left-sided CDH, but only in high-volume centers with the experience and capability of removing the balloon, emergently if needed. The neonatal clinical team must be skilled in managing the unique postnatal physiology inherent to FETO where effective interdisciplinary teamwork is essential. Empiric and immediate surfactant administration should be considered in all FETO infants to lavage thick airway secretions, particularly those delivered <48 h after balloon removal.


Asunto(s)
Oclusión con Balón , Hernias Diafragmáticas Congénitas , Recién Nacido , Lactante , Femenino , Humanos , Embarazo , Hernias Diafragmáticas Congénitas/cirugía , Estudios Retrospectivos , Estudios de Cohortes , Salas de Parto , Oclusión con Balón/métodos , Placenta , Fetoscopía/métodos , Tráquea/cirugía , Tensoactivos
2.
Laryngoscope ; 134(1): 452-458, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37194657

RESUMEN

OBJECTIVES: To describe the use of customized and custom tracheostomies at our institution, and to identify trends in patient presentation and tracheostomy design. METHODS: A retrospective review was conducted for patients at our institution for whom a customized or custom tracheostomy tube was ordered between January 2011 and July 2021. Customized tracheostomy tubes allow for a small selection of alterations to trach design, such as cuff length and flange type. Custom tracheostomies have a unique design created by tracheostomy tube engineers in collaboration with the clinical provider, and are built specifically for a single patient. RESULTS: A total of 235 patients were included, of whom 220 (93%) received customized tracheostomies and 15 custom (7%). The most common indications for customized tracheostomy were tracheal or stomal breakdown on a standard tracheostomy (n = 73, 33%) and ventilation difficulties (n = 61, 27%). The most frequent customization was shaft length (n = 126, 57%). The most common indication for custom tracheostomies was a persistent air leak on a standard or customized trach (n = 9) and the most frequent designs were custom cuffs (n = 8), flanges (n = 4), and anteriorly curved shafts (n = 4). Patients treated with a customized tracheostomy had a 5-year overall survival of 75.3%, compared to 51.4% for custom. CONCLUSION: These are the first cohorts of pediatric patients with customized and custom tracheostomies to be described. Modifications to tracheostomies, in particular shaft length and cuff design, can address common complications of extended tracheostomy, and may help improve ventilation in the most challenging cases. LEVEL OF EVIDENCE: 4 Laryngoscope, 134:452-458, 2024.


Asunto(s)
Tráquea , Traqueostomía , Humanos , Niño , Traqueostomía/efectos adversos , Tráquea/cirugía , Estudios Retrospectivos
3.
Laryngoscope ; 134(5): 2444-2448, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37983867

RESUMEN

OBJECTIVE: Surgical plume has known potential occupational health hazards. This study compares nanoparticle concentrations in surgical plumes generated between different pediatric tonsillectomy surgical techniques and assesses the efficacy of mitigation measures. METHODS: This is a cross-sectional study performed at a tertiary care academic center. Extracapsular or intracapsular tonsillectomy was performed in 60 patients using four techniques and in 10 additional patients using mitigation measures. Two nanoparticle counters were used to measure particulate concentrations: CPC™ and DiSCmini™. Tonsillectomy techniques included: (1) microdebrider (MD), (2) Bovie with manual suctioning by an assistant (B), (3) Bovie with built-in smoke evacuation system (BS), and (4) Coblator™ (CB). An additional Yankauer suction was used in the mitigation groups (BSY) and (CBY). Comparative analysis was performed using one-way ANOVA on ranks and pairwise comparisons between the groups. RESULTS: The mean concentrations (particles/cm3) and coefficient of variants for the DiSCmini particulate counter were MD: 5140 (1.6), B: 30700 (1.5), BS: 25001 (0.8), CB: 54814 (1.7), CBY: 2395 (1.3) and BSY: 11552 (1.0). Mean concentrations for the CPC particulate counter were MD: 1223 (1.4), B: 3405 (0.7), BS: 5002 (0.9), CB: 13273 (1.0), CBY: 1048 (1.2) and BSY: 3046 (0.6). The lowest mean concentrations were noted in cases using MD and the highest in cases using CB. However, after mitigation, CBY had the lowest overall levels. CONCLUSION: Tonsillectomy technique does impact the levels of nanoparticles emitted within the surgical plume, which may present an occupational hazard for operating room personnel. LEVEL OF EVIDENCE: 3 Laryngoscope, 134:2444-2448, 2024.


Asunto(s)
Tonsilectomía , Niño , Humanos , Tonsilectomía/métodos , Estudios Transversales , Adenoidectomía , Electrocirugia , Electrocoagulación/métodos , Polvo
4.
Cleft Palate Craniofac J ; : 10556656231204517, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37915226

RESUMEN

PURPOSE: Mandibular distraction osteogenesis (MDO) may improve airway grade in patients with Robin Sequence (RS), but little is known about the response of the oropharyngeal airway to the distraction process in cases of tongue base obstruction (TBAO). This study used drug-induced sleep endoscopy (DISE) to evaluate the impact of MDO on the oropharynx. METHODS: RS patients with severe obstructive sleep apnea (OSA) were prospectively enrolled, and underwent DISE prior to MDO, and at the time of distractor removal. Laryngoscopy views, glossoptosis degree, polysomnography (PSG) results, oxygen saturations and airway measurements were compared pre- and post-MDO. RESULTS: Twenty patients met inclusion criteria. At the time of distractor placement, a grade II laryngoscopic view was most frequently observed (63%), and one patient (5%) had a grade I view. Median obstructive apnea hypopnea index (OAHI) improved after MDO (49.1 [30.2-74.0] to 9.1, [3.9-18.0], p ≤ .001). Median oxygen saturation nadir also improved (preoperative 69% [60-76] to 85% [82-91], p ≤ .001). At distractor removal, mean laryngoscopic view improved (p ≤ .002) with no views that were grade 3 or higher. Median intraoperative oropharyngeal width improved, (3.1 mm [2.8-4.4] to 6.0 mm [4.4-6.8], p ≤ .021), as did median cephalometric anteroposterior oropharyngeal width (3.5 mm [2.7-4.1] to 6.3 mm [5.6-8.2], p ≤ .002). CONCLUSION: Following MDO, RS patients with TBAO have an approximate doubling of oropharyngeal width and an improvement in laryngoscopic grade. These findings likely contribute to improved oxygenation, OAHI and ease of intubation.