Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Intervalo de año de publicación
1.
Arch Soc Esp Oftalmol ; 84(6): 283-92, 2009 Jun.
Artículo en Español | MEDLINE | ID: mdl-19568988

RESUMEN

OBJECTIVE: Revision of methods for estimating corneal power (Kpost) and effective lens position (ELP) for cataract surgery after corneal refractive surgery. METHODS: Review of medical literature. RESULTS: To calculate the intraocular lens that achieves emetropia after corneal refractive surgery it is necessary to correct the Kpost and to estimate the effective lens position again correcting it. There are different formulae depending on the available information. Ideally, we need pre (Kpre) and post-treatment keratometry record (Kpost) and pre (Rpre) and post (Rpost) refraction. In this way, we can use the Aramberri's double-K method in the formula for calculating intraocular lens power. CONCLUSIONS: Previously to keratorefractive procedure is advisable to have pre-treatment refraction and keratometry (K and method) registered: Kpre value is critical to calculate the ELP.


Asunto(s)
Lentes Intraoculares , Queratectomía Fotorrefractiva , Humanos , Implantación de Lentes Intraoculares , Matemática
2.
Arch. Soc. Esp. Oftalmol ; 84(6): 283-292, jun. 2009. ilus, tab
Artículo en Español | IBECS | ID: ibc-75595

RESUMEN

Objetivo: Revisión de las distintas fórmulas decorrección del poder refractivo de la córnea (Kpost)y de la estimación de la posición efectiva de la lente(ELP) para la cirugía de cataratas después decirugía refractiva corneal.Método: Revisión de la literatura médica.Resultados: Es necesario realizar una correcciónde la Kpost para el cálculo de la lente intraoculartras cirugía refractiva. Existen diferentes víasdependiendo de la información disponible. Paraestimar la ELP es necesario realizar una nuevacorrección. Es aconsejable disponer de la queratometríaprevia (Kpre) y posterior (Kpost) a la cirugíay la refracción previa (Rpre) y posterior (Rpost). Deesta manera, podremos realizar la corrección doble-K de Aramberri en la fórmula de cálculo.Conclusiones: Es conveniente registrar la refraccióny queratometría (K, y método) previamente ala cirugía refractiva: la Kpre es crítica para el cálculo de la ELP(AU)


Objective: Revision of methods for estimating cornealpower (Kpost) and effective lens position(ELP) for cataract surgery after corneal refractivesurgery.Methods: Review of medical literature.Results: To calculate the intraocular lens thatachieves emetropia after corneal refractive surgeryit is necessary to correct the Kpost and to estimatethe effective lens position again correcting it. Thereare different formulae depending on the availableinformation. Ideally, we need pre (Kpre) and posttreatmentkeratometry record (Kpost) and pre(Rpre) and post (Rpost) refraction. In this way, wecan use the Aramberri’s double-K method in theformula for calculating intraocular lens power.Conclusions: Previously to keratorefractive procedureis advisable to have pre-treatment refractionand keratometry (K and method) registered: Kprevalue is critical to calculate the ELP(AU)


Asunto(s)
Humanos , Masculino , Femenino , Lentes Intraoculares , Procedimientos Quirúrgicos Refractivos , Procedimientos Quirúrgicos Refractivos/métodos , Catarata , Catarata/terapia , Extracción de Catarata , Extracción de Catarata/métodos , Bases de Datos Bibliográficas
3.
Eur J Ophthalmol ; 11 Suppl 2: S67-71, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11592534

RESUMEN

PURPOSE: We evaluated the efficacy of topical brimonidine in visual field preservation and/or improvement in eyes undergoing controlled glaucoma. METHODS: Seventy eyes of patients were trained with two different visual field test strategies: The Octopus Tendency Oriented Perimetry (TOP) G1 and the Frequency Doubling Technology (FDT) 30 degrees. Following 2-4 months of brimonidine treatment, there were significant improvements in visual field, as assessed using the TOP G1 strategy (p = 0.003). The FDT 30 degrees test revealed no statistically significant differences. CONCLUSIONS: These data support the results of other studies, which indicate that brimonidine may increase mean sensitivity in visual field tests. Since it is known that the control of intraocular pressure does not fully protect glaucomatous eyes from visual field loss, it is possible that the neuroprotective qualities of brimonidine may contribute to visual field preservation in glaucomatous eyes.


Asunto(s)
Agonistas de Receptores Adrenérgicos alfa 2 , Agonistas alfa-Adrenérgicos/administración & dosificación , Glaucoma/tratamiento farmacológico , Quinoxalinas/administración & dosificación , Campos Visuales/efectos de los fármacos , Administración Tópica , Adulto , Anciano , Anciano de 80 o más Años , Tartrato de Brimonidina , Femenino , Humanos , Presión Intraocular/efectos de los fármacos , Masculino , Persona de Mediana Edad , Soluciones Oftálmicas , Pruebas del Campo Visual
4.
Lasers Surg Med ; 11(4): 347-50, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1895866

RESUMEN

We applied diode laser energy through a fiberoptic probe to cut ocular structures. The diameter of the probe's tip was 100 microns. The amount of energy used for cutting the lid, the cornea, or for perforation of the glove was 2.5 watts in the continuous mode. The incised border demonstrated coagulation into the healthy tissue ranging from 10 to 50 microns.


Asunto(s)
Fotocoagulación/instrumentación , Procedimientos Quirúrgicos Oftalmológicos , Animales , Cámara Anterior/cirugía , Coroides/cirugía , Conjuntiva/cirugía , Córnea/cirugía , Cartílago Auricular/cirugía , Párpados/cirugía , Tecnología de Fibra Óptica , Rayos Láser , Fotocoagulación/métodos , Conejos , Esclerótica/cirugía , Cuerpo Vítreo/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA