1.
Cytogenet Genome Res ; 163(3-4): 154-162, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37573786

RESUMEN

Radioiodine (131I) is widely used in the treatment of hyperthyroidism and as an effective ablative therapy for differentiated thyroid cancer. Radioiodine (131I) constitutes 90% of the currently used therapies in the field of nuclear medicine. Here, we report the cytogenetic findings of a long-term follow-up study of 27 years on a male patient who received two rounds of radioiodine treatment within a span of 26 months between 1992 and 1994 for his papillary thyroid cancer. A comprehensive cytogenetic follow-up study utilizing cytokinesis blocked micronucleus assay, dicentric chromosome assay, genome wide translocations and inversions was initiated on this patient since the first administration of radioiodine in 1992. Frequencies of micronuclei (0.006/cell) and dicentric chromosomes (0.008/cell) detected in the current study were grossly similar to that reported earlier in 2019. The mFISH analysis detected chromosome aberrations in 8.6% of the cells in the form of both unbalanced and balanced translocations. Additionally, a clonal translocation involving chromosomes 14p; 15q was observed in 2 of the 500 cells analyzed. Out of the 500 cells examined, one cell showed a complex translocation (involving chromosomes 9, 10, and 16) besides 5 other chromosome rearrangements. Collectively, our study indicates that the past radioiodine exposure results in long-lasting chromosome damage and that the persistence of translocations can be useful for both retrospective biodosimetry and for monitoring chromosome instability in the lymphocytes of radioiodine exposed individuals.


Asunto(s)
Radioisótopos de Yodo , Translocación Genética , Humanos , Masculino , Estudios de Seguimiento , Radioisótopos de Yodo/efectos adversos , Estudios Retrospectivos , Análisis Citogenético/métodos
2.
J Radiol Prot ; 42(2)2022 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-35196651

RESUMEN

Large-scale radiological accidents or nuclear terrorist incidents involving radiological or nuclear materials can potentially expose thousands, or hundreds of thousands, of people to unknown radiation doses, requiring prompt dose reconstruction for appropriate triage. Two types of dosimetry methods namely, biodosimetry and physical dosimetry are currently utilized for estimating absorbed radiation dose in humans. Both methods have been tested separately in several inter-laboratory comparison exercises, but a direct comparison of physical dosimetry with biological dosimetry has not been performed to evaluate their dose prediction accuracies. The current work describes the results of the direct comparison of absorbed doses estimated by physical (smartphone components) and biodosimetry (dicentric chromosome assay (DCA) performed in human peripheral blood lymphocytes) methods. For comparison, human peripheral blood samples (biodosimetry) and different components of smartphones, namely surface mount resistors (SMRs), inductors and protective glasses (physical dosimetry) were exposed to different doses of photons (0-4.4 Gy; values refer to dose to blood after correction) and the absorbed radiation doses were reconstructed by biodosimetry (DCA) and physical dosimetry (optically stimulated luminescence (OSL)) methods. Additionally, LiF:Mg,Ti (TLD-100) chips and Al2O3:C (Luxel) films were used as reference TL and OSL dosimeters, respectively. The best coincidence between biodosimetry and physical dosimetry was observed for samples of blood and SMRs exposed toγ-rays. Significant differences were observed in the reconstructed doses by the two dosimetry methods for samples exposed to x-ray photons with energy below 100 keV. The discrepancy is probably due to the energy dependence of mass energy-absorption coefficients of the samples extracted from the phones. Our results of comparative validation of the radiation doses reconstructed by luminescence dosimetry from smartphone components with biodosimetry using DCA from human blood suggest the potential use of smartphone components as an effective emergency triage tool for high photon energies.


Asunto(s)
Radiometría , Triaje , Humanos , Fotones , Dosímetros de Radiación , Radiometría/métodos , Triaje/métodos , Rayos X
3.
J Radiol Prot ; 41(4)2021 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-34233319

RESUMEN

Cells exposed to ionizing radiation have a wide spectrum of DNA lesions that include DNA single-strand breaks, DNA double-strand breaks (DSBs), oxidative base damage and DNA-protein crosslinks. Among them, DSB is the most critical lesion, which when mis-repaired leads to unstable and stable chromosome aberrations. Currently, chromosome aberration analysis is the preferred method for biological monitoring of radiation-exposed humans. Stable chromosome aberrations, such as inversions and balanced translocations, persist in the peripheral blood lymphocytes of radiation-exposed humans for several years and, therefore, are potentially useful tools to prognosticate the health risks of radiation exposure, particularly in the hematopoietic system. In this review, we summarize the cytogenetic follow-up studies performed by REAC/TS (Radiation Emergency Assistance Center/Training site, Oak Ridge, USA) on humans exposed to internal and external radiation. In the light of our observations as well as the data existing in the literature, this review attempts to highlight the importance of follow-up studies for predicting the extent of genomic instability and its impact on delayed health risks in radiation-exposed victims.


Asunto(s)
Roturas del ADN de Doble Cadena , Radiación Ionizante , Aberraciones Cromosómicas , Análisis Citogenético , Estudios de Seguimiento , Humanos
4.
Cytogenet Genome Res ; 159(4): 169-181, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31846971

RESUMEN

Here, we report the findings of a 25-year cytogenetic follow-up study on a male patient who received 2 rounds of radioiodine treatment within a span of 26 months (1.78 GBq in 1992 and 14.5 GBq in 1994). The patient was 34 years old with a body mass index of 25 at the time of the first radioiodine treatment. Multicolor FISH and multicolor banding (mBAND) techniques performed on the patient detected inter- and intrachromosomal exchanges. Although the frequency of chromosome translocations remained essentially the same as reported in our earlier study (0.09/cell), the percentage of reciprocal (balanced) translocations increased from 54.38 to 80.30% in the current study. In addition to simple chromosome translocations, complex exchanges (0.29%) involving more than 2 chromosomes were detected for the first time in this patient. Strikingly, a clonal translocation involving chromosomes 14 and 15, t(14p;15q), was found in 7 of the 677 cells examined (1.03%). The presence of complex and clonal translocations indicates the onset of chromosomal instability induced by internal radioiodine exposure. mBAND analysis using probes specific for chromosomes 1, 2, 4, 5, and 10 revealed 5 inversions in a total of 717 cells (0.69%), and this inversion frequency is several-fold higher than the baseline frequency reported in healthy individuals using the classical G-banding technique. Collectively, our study suggests that stable chromosome aberrations such as translocations and inversions can be useful not only for retrospective biodosimetry but also for long-term monitoring of chromosomal instability caused by past radioiodine exposure.


Asunto(s)
Cromosomas/genética , Cromosomas/efectos de la radiación , Radioisótopos de Yodo/efectos adversos , Translocación Genética/genética , Translocación Genética/efectos de la radiación , Adulto , Aberraciones Cromosómicas/efectos de la radiación , Bandeo Cromosómico/métodos , Inversión Cromosómica/genética , Inversión Cromosómica/efectos de la radiación , Citogenética/métodos , Estudios de Seguimiento , Humanos , Masculino
5.
Artículo en Inglés | MEDLINE | ID: mdl-31699339

RESUMEN

Dicentric Chromosome Assay (DCA) is the most preferred cytogenetic technique for absorbed radiation dose assessment in exposed humans. However, DCA is somewhat impractical for triage application owing to its labor intensive and time consuming nature. Although lymphocyte culture for 48 h in vitro is inevitable for DCA, manual scoring of dicentric chromosomes (DCs) requires an additional time of 24-48 h, making the overall turnaround time of 72-96 h for dose estimation. To accelerate the speed of DC analysis for dose estimation, an automated tool was optimized and validated for triage mode of scoring. Several image training files were created to improve the specificity of automated DC analysis algorithm. Accuracy and efficiency of the automated (unsupervised) DC scoring was compared with the semi-automated scoring that involved human verification and correction of DCs (elimination of false positives and inclusion of true positives). DC scoring was performed by both automated and semi-automated modes for different doses of X-rays and γ-rays (0 Gy-5 Gy). Biodoses estimated from the frequencies of DCs detected by both automated (unsupervised) and semi-automated (supervised) scoring modes were grossly similar to the actual delivered doses in the range of 0.5 to 3 Gy of low LET radiation. We suggest that the automated DC tool can be effectively used for large scale radiological/nuclear incidents where a rapid segregation is essential for prioritizing moderately or severely exposed humans to receive appropriate medical countermeasures.


Asunto(s)
Cromosomas Humanos/efectos de la radiación , Linfocitos/efectos de la radiación , Incidentes con Víctimas en Masa , Traumatismos por Radiación/diagnóstico , Liberación de Radiactividad Peligrosa , Radiometría/métodos , Triaje/normas , Automatización , Células Cultivadas , Cromosomas Humanos/genética , Cromosomas Humanos/ultraestructura , Roturas del ADN de Doble Cadena , Relación Dosis-Respuesta en la Radiación , Rayos gamma , Humanos , Linfocitos/ultraestructura , Metafase , Dosis de Radiación , Traumatismos por Radiación/genética , Factores de Tiempo , Triaje/métodos , Rayos X
6.
PLoS One ; 14(5): e0216081, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31059552

RESUMEN

A sensitive biodosimetry tool is required for rapid individualized dose estimation and risk assessment in the case of radiological or nuclear mass casualty scenarios to prioritize exposed humans for immediate medical countermeasures to reduce radiation related injuries or morbidity risks. Unlike the conventional Dicentric Chromosome Assay (DCA), which takes about 3-4 days for radiation dose estimation, cell fusion mediated Premature Chromosome Condensation (PCC) technique in G0 lymphocytes can be rapidly performed for radiation dose assessment within 6-8 hrs of sample receipt by alleviating the need for ex vivo lymphocyte proliferation for 48 hrs. Despite this advantage, the PCC technique has not yet been fully exploited for radiation biodosimetry. Realizing the advantage of G0 PCC technique that can be instantaneously applied to unstimulated lymphocytes, we evaluated the utility of G0 PCC technique in detecting ionizing radiation (IR) induced stable and unstable chromosomal aberrations for biodosimetry purposes. Our study demonstrates that PCC coupled with mFISH and mBAND techniques can efficiently detect both numerical and structural chromosome aberrations at the intra- and inter-chromosomal levels in unstimulated T- and B-lymphocytes. Collectively, we demonstrate that the G0 PCC technique has the potential for development as a biodosimetry tool for detecting unstable chromosome aberrations (chromosome fragments and dicentric chromosomes) for early radiation dose estimation and stable chromosome exchange events (translocations) for retrospective monitoring of individualized health risks in unstimulated lymphocytes.


Asunto(s)
Aberraciones Cromosómicas/efectos de la radiación , Linfocitos/efectos de la radiación , Radiometría/métodos , Animales , Células CHO/efectos de la radiación , Fusión Celular , Centrómero/efectos de la radiación , Cricetulus , Femenino , Rayos gamma/efectos adversos , Humanos , Hibridación Fluorescente in Situ , Masculino , Traumatismos por Radiación/diagnóstico , Traumatismos por Radiación/genética , Radiación Ionizante , Estudios Retrospectivos , Cariotipificación Espectral/métodos , Telómero/efectos de la radiación , Rayos X/efectos adversos
7.
J Cell Biochem ; 120(5): 8619-8629, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30536664

RESUMEN

Dicentric chromosome assay (DCA) is routinely used for estimating the absorbed radiation dose in exposed humans. Optimal lymphocyte viability is crucial for reliable dose estimation and most cytogenetic laboratories prefer the receipt of blood samples within 24 to 36 hours after collection. Delays in the shipment/receipt of samples can occur sometimes under certain unforeseen circumstances: (1) Adverse weather conditions, (2) distant location of blood collection sites, and (3) shipping and handling of a large number of samples after radiological/nuclear mass casualty incident(s). To circumvent some of these limitations, we evaluated the suitability of ex vivo irradiated blood samples stored in the presence of phytohemagglutinin (PHA) for 7 days at ambient temperature (22-24°C) for radiation biodosimetry. Blood samples stored in the presence of PHA for up to 7 days showed a higher mitotic index than blood samples stored without PHA. To verify the use of stored blood samples for DCA, frequencies of X-rays induced dicentric chromosomes were analyzed in the blood samples that were cultured either 24 hours after exposure or 7 days later after storage. Our results indicate that storage of ex vivo irradiated blood samples in the presence of PHA at ambient temperature was found optimal for DCA and that the radiation doses estimated by dicentric chromosome frequencies were grossly similar between the fresh and stored blood samples. Our study suggests that reliable and accurate biodosimetry results can be obtained for triage using blood samples stored for up to a week at ambient temperature in the presence of PHA.

8.
Radiat Prot Dosimetry ; 182(1): 139-145, 2018 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-30247729

RESUMEN

Use of ionizing radiation (IR) in various industrial, medical and other applications can potentially increase the risk of medical, occupational or accidental human exposure. Additionally, in the event of a radiological or nuclear (R/N) incident, several tens of hundreds and thousands of people are likely to be exposed to IR. IR causes serious health effects including mortality from acute radiation syndrome and therefore it is imperative to determine the absorbed radiation dose, which will enable physicians in making an appropriate clinical 'life-saving' decision. The 'Dicentric Chromosome Assay (DCA)' is the gold standard for estimating the absorbed radiation dose but its performance is time consuming and laborious. Further, timely evaluation of dicentric chromosomes (DCs) for dose estimation in a large number of samples provides a bottleneck because of a limited number of trained personnel and a prolonged time for manual analysis. To circumvent some of these technical issues, we developed and optimized a miniaturized high throughput version of DCA (mini-DCA) in a 96-microtube matrix with bar-coded 1.4 ml tubes to enable the processing of a large number of samples. To increase the speed of DC analysis for radiation dose estimation, a semi-automated scoring was optimized using the Metafer DCScore algorithm. The accuracy of mini-DCA in dose estimation was verified and validated though comparison with conventional DCA performed in 15 ml conical tubes. The mini-DCA considerably reduced the sample processing time by a factor of 4 when compared to the conventional DCA. Further, the radiation doses estimated by mini-DCA using the triage mode of scoring (50 cells or 30 DCs) were similar to that of conventional DCA using 300-500 cells. The mini-DCA coupled with semi-automated DC scoring not only reduced the sample processing and analysis times by a factor of 4 but also enabled the processing of a large number of samples at once. Our mini-DCA method, once automated for high throughput robotic platforms, will be an effective radiological triage tool for mass casualty incidents.


Asunto(s)
Bioensayo/métodos , Aberraciones Cromosómicas/efectos de la radiación , Cromosomas Humanos/efectos de la radiación , Exposición a la Radiación/efectos adversos , Triaje , Relación Dosis-Respuesta en la Radiación , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA