Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38627244

RESUMEN

We evaluated the feasibility of harvesting bilateral internal thoracic arteries with the da Vinci Single Port system (SP) through a single left-sided subcostal incision. Complete bilateral mobilization with sufficiently long conduits for multivessel grafting was possible in 2 human cadavers and 2 live porcine. Creating the subcostal access and docking the SP system took between 14 and 21 min and the total harvest time ranged from 65 to 125 min in all models. No major bleeding was observed in the live porcine and hemostasis was managed with the available instrumentation. One porcine deceased during surgery due to ventricular fibrillation followed by cardiac arrest. The robotic harvesting was technically easily reproduced by the surgeons and required no additional rib-spreading. Further studies will be required to assess if this subcostal approach with the da Vinci SP system yields true clinical benefits in patients.

2.
Updates Surg ; 74(5): 1733-1738, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35211841

RESUMEN

Robotic subxiphoid transthoracic thymectomy showed several surgical advantages. Nevertheless, the intercostal insertion of trocars may lead to nerve injury with enhanced post-operative pain. Moreover, the dissection of peri-diaphragmatic mediastinal fat may result challenging, in particular on left side, where the presence of the heart precludes the optimal visualization. We describe a preclinical cadaveric study of a novel full subcostal robotic-assisted technique to overcome these limitations. A total subcostal robotic-assisted radical thymectomy was evaluated on a cadaver model using the da Vinci Xi system. The exploratory procedure was divided in two steps: (a) dissection of the thymus gland, except the left mediastinal epi-diaphragmatic fat pad; (b) dissection of the left diaphragmatic mediastinal fat pad avoiding heart compression while perfectly visualizing the left phrenic nerve. Five different setups were explored based on camera and trocars insertions, patient's positioning and table's settings. Both the tasks were accomplished using the novel technique. The subxiphoid insertion of the camera and the position of two robotic arms about 8 cm distally on the subcostal made the most part of mediastinal dissection straightforward. Left peri-diaphragmatic fat pad can be better visualized and dissected positioning the camera in the left subcostal port shifting the instruments on the right side. This may permit a better control of the left phrenic nerve reducing heart compression. Full subcostal robotic-assisted thymectomy resulted feasible in cadaveric model. Clinical trial should be performed to confirm the translational use of this novel technique and the speculated advantages in living model.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Robótica , Cadáver , Humanos , Posicionamiento del Paciente , Procedimientos Quirúrgicos Robotizados/métodos , Timectomía/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...