1.
Int J Pharm ; 611: 121313, 2022 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-34822965

RESUMEN

Residence time distribution (RTD) models were developed to track raw material lots and investigate batch transitions in a continuous manufacturing system. Two raw materials with similar physical properties (granular metformin and lactose) were identified via Principal Component Analysis (PCA) from a library of bulk material properties and used to simulate the switching of lots during production. In-line near-infrared (NIR) spectra were collected with the powder flowing through a chute in a continuous manufacturing system to monitor metformin and lactose concentration in step-change experiments with Partial Least Squares (PLS) models. RTD provided an understanding of raw material propagation through the continuous manufacturing system. Transition times between raw material changes were identified using the results of two multivariate approaches PLS and PCA. The methodology was implemented to discriminate the transition zone in a raw material change, contributing to design control strategies for acceptance and diverting mechanisms.


Asunto(s)
Preparaciones Farmacéuticas
2.
J Pharm Biomed Anal ; 154: 384-396, 2018 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-29571136

RESUMEN

Near infrared (NIR) spectroscopy was used to determine the drug concentration in 3% (w/w) acetaminophen blends within the complex flow regime of the tablet press feed frame just before tablet compaction. NIR spectra also provided valuable information on the powder flow behavior within the feed frame and were used to track when a process enters or leaves the steady state. A partial least squares regression calibration model was developed with powder mixtures that varied from 1.5 to 4.5% (w/w) by obtaining 135 spectra after steady state for each concentration while the feed frame and die disc operated at 30.5 revolutions per minute (rpm). The calibration model determined drug concentration in validation blends with a root mean square error of prediction and bias below 0.1% (w/w). The robustness of the NIR calibration model was evaluated by determining the effect of variation on the operating conditions (paddle wheel speed and die disc speed) on NIR predictions. This work found that the paddle wheel speed can be increased up to 30% and the die disc speed decrease 10% without affecting NIR predictions. The results demonstrated that paddle wheel speed has a significant effect on the wave powder behavior (frequency and amplitude) but does not have significant effect on the mass hold-up within feed frame. The die disc speed does not affect wave powder behavior but affects significantly the mass hold-up inside the feed frame. This information can be used to reduce the tablet weight variability and ensure that this critical attribute is met.


Asunto(s)
Acetaminofén/química , Polvos/química , Comprimidos/química , Calibración , Composición de Medicamentos/métodos , Análisis de los Mínimos Cuadrados , Espectroscopía Infrarroja Corta/métodos , Factores de Tiempo
3.
J Pharm Biomed Anal ; 123: 120-7, 2016 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-26895497

RESUMEN

This study describes the development of near infrared (NIR) calibration models using transmittance measurements in powder samples and compares the results obtained with those of tablet transmittance and diffuse reflectance of powders. Transmission near infrared spectroscopy is a method widely used for the analysis of tablets in the evaluation of drug concentration due to the larger sample volume analyzed, but not commonly used for the analysis of powder samples. Diffuse reflection near infrared spectroscopy is a method used in both powder and tablets for the evaluation of quality attributes. In this initial study NIR transmittance measurements were obtained using an off-line spectrometer equipped with a high intensity light source. Spectra were obtained with three different resolutions for the analysis of powder and tablet samples of 7.50-22.50% (w/w) acetaminophen. The Partial Least Squares (PLS) calibration models developed include pretreatments such as Standard Normal Variate (SNV) and first derivative in the region from 9500-7500 cm(-1). Transmittance in powder presented low Root Mean Square Error of Prediction (RMSEP) values that varied from 0.23-1.15% (w/w) APAP with resolution of 64 and 16 cm(-1). The lowest RMSEP values (0.23-0.39% (w/w) APAP) were obtained using a resolution of 64 cm(-1). The RMSEP values for powder transmittance measurements were 2.4-5.6 times lower than the diffuse reflectance measurements of the powder mixtures.


Asunto(s)
Preparaciones Farmacéuticas/química , Polvos/química , Espectroscopía Infrarroja Corta/métodos , Acetaminofén/química , Calibración , Análisis de los Mínimos Cuadrados , Modelos Teóricos , Comprimidos/química
SELECCIÓN DE REFERENCIAS